• Title/Summary/Keyword: High-radiation Environment

Search Result 430, Processing Time 0.026 seconds

VLC Wireless Data Transmission of High Luminance LED Irradiated by the High Dose-Rate Gamma-Ray (고 선량 감마선 조사에 따른 고휘도 LED의 가시광 무선 데이터 전송)

  • Cho, Jai-Wan;Choi, Young-Soo;Hong, Seok-Boong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.996-1000
    • /
    • 2010
  • In order to apply VLC (visible light communication) in harsh environment of nuclear power plant in-containment building, the high luminance LEDs, which are key components of the VLC system, have been gamma irradiated at the dose rate of 4 kGy/h during 72 hours up to a total dose of 288 kGy. The radiation induced coloration effect in the high luminance LED bulb made of acryl or plastic material was observed. In the VLC wireless data transmission experiment using the high luminance LEDs irradiated by high dose rate gamma-ray, the radiation induced coloration effect of the high luminance LED bulb extended the communication distance compared to non-irradiated LEDs.

Effect of Aerosol Feedback on Solar Radiation in the Korean Peninsula Using WRF-CMAQ Two-way Coupled Model (WRF-CMAQ 결합모델을 이용한 에어로졸 피드백 효과가 한반도 일사량에 미치는 영향 연구)

  • Yoo, Jung-Woo;Park, Soon-Young;Jeon, WonBae;Kim, Dong-Hyeok;Lee, HwaWoon;Lee, Soon-Hwan;Kim, Hyun-Goo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.5
    • /
    • pp.435-444
    • /
    • 2017
  • In this study, we investigated the effect of aerosol feedback on $PM_{10}$ simulation using a two-way coupled air quality model (WRF-CMAQ). $PM_{10}$ concentration over Korea in January 2014 was simulated, and the aerosol feedback effect on the simulated solar radiation was intensively examined. Two $PM_{10}$ simulations were conducted using the WRF-CMAQ model with (FB) and without(NFB) the aerosol feedback option. We find that the simulated solar radiation in the west part of Korea decreased by up to $-80MJ/m^2$ due to the aerosol feedback effect. The feedback effect was significant in the west part of Korea, showing high $PM_{10}$ estimates due to dense emissions and its long-range transport from China. The aerosol feedback effect contributed to the decreased rRMSE(relative Root Mean Square Error) for solar radiation (47.58% to 30.75%). Aerosol feedback effect on the simulated solar radiation was mainly affected by concentration of $PM_{10}$. Moreover, FB better matched the observed solar radiation and $PM_{10}$ concentration than NFB, implying that taking into account the aerosol direct effects resulted in the improved modeling performance. These results indicate that aerosol feedback effects can play an important role in the simulation of solar radiation over Korean Peninsula.

Development of low-cost, compact, real-time, and wireless radiation monitoring system in underwater environment

  • Kim, Jeong Ho;Park, Ki Hyun;Joo, Koan Sik
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.801-805
    • /
    • 2018
  • In this study, an underwater radiation detector was built using a GAGG(Ce) scintillator and silicon photomultiplier to establish an underwater radiation exposure monitoring system. The GAGG(Ce) scintillator is suitable for small radiation detectors as it strongly absorbs gamma rays and has a high light emission rate with no deliquescent properties. Additionally, the silicon photomultiplier is a light sensor with characteristics such as small size and low applied voltage. Further, a program and mobile app were developed to monitor the radiation coefficient values generated from the detector. According to the results of the evaluation of the characteristics of the underwater radiation monitoring system, when tested for its responsiveness to radiation intensity and reactivity, the system exhibited a coefficient of determination of at least 0.99 with respect to the radiation source distance. Additionally, when tested for its underwater environmental temperature dependence, the monitoring system exhibited an increase in the count rate up to a certain temperature because of the increasing dark current and a decrease in the count rate because of decreasing overvoltage. Extended studies based on the results of this study are expected to greatly contribute to immediate and continuing evaluation of the degree of radioactive contamination in underwater environments.

Status of Domestic and International Recommendations for Protection Design and Evaluation of Medical Linear Accelerator Facilities

  • Choi, Sang Hyoun;Shin, Dong Oh;Shin, Jae-ik;Kwon, Na Hye;Ahn, So Hyun;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.83-91
    • /
    • 2021
  • Various types of high-precision radiotherapy, such as intensity-modulated radiation therapy (IMRT), tomotherapy (Tomo), and stereotactic body radiation therapy have been available since 1997. After being covered by insurance in 2015, the number of IMRT cases rapidly increased 18-fold from 2011 to 2018 in Korea. IMRT, which uses a high-beam irradiation monitor unit, requires higher shielding conditions than conventional radiation treatments. However, to date, research on the shielding of facilities using IMRT and the current understanding of its status are insufficient, and detailed safety regulation procedures have not been established. This study investigated the recommended criteria for the shielding evaluation of facilities using medical linear accelerators (LINACs), including 1) the current status of safety management regulations and systems in domestic and international facilities using medical LINACs and 2) the current status of the recommended standards for safety management in domestic and international facilities using medical LINACs. It is necessary to develop and introduce a safety management system for facilities using LINACs for clinical applications that is suitable for the domestic medical environment and corresponds to the safety management systems for LINACs used overseas.

A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation (고 선량율 감마선 조사에 따른 렌즈의 열화)

  • Cho, Jai-Wan;Lee, Joon-Koo;Hur, Seop;Koo, In-Soo;Hong, Seok-Boong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1450-1455
    • /
    • 2009
  • Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

Livestock Wastewater Treatment by Zeolite Ion Exchange and Gamma-ray Irradiation (제올라이트와 감마선을 이용한 축산 폐수 처리)

  • Lee, Sang-Ryul;Kim, Tak-Hyun;Lee, Myun-joo
    • Journal of Radiation Industry
    • /
    • v.2 no.1
    • /
    • pp.9-14
    • /
    • 2008
  • Livestock wastewater containing high concentrations of organic matters and ammonia-nitrogen has been known as one of the recalcitrant wastewater. It is difficult to treat by conventional wastewater treatment techniques. This study was carried out to evaluate the feasibility of zeolite ion exchange and gamma-ray irradiation treatment of livestock wastewater. The removal efficiencies of $SCOD_{Cr}$ and $NH_3-N$ were significantly enhanced by gamma-ray irradiation after zeolite ion exchange as a pre-treatment. However, the effects of zeolite particle size on the $SCOD_{Cr}$ and $NH_3-N$ removal efficiencies were insignificant. These results indicate that the combined process of zeolite ion exchange and gamma-ray irradiation has potential for the treatment of livestock wastewater.

COASTAL ENVIRONMENT MONITORING USING ADJACENT EFFECT OF RADIATION

  • Takashima, Tsutomu;Jung, Sung-Chul;Yi, San-Oh;Kim, Tu-Hwan
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.430-431
    • /
    • 2006
  • KOMPSAT-2 was successively launched on July 28,06. She carries Fine Spatial Resolution Sensor with three channels. It is 4m monochromatic and 1m panchromatic. The main purposes would derive fine urban map and digital elevation model(DEM).Therefore we extend to coastal environment monitoring using the adjacent effect of radiation due to an interaction of radiation between heterogeneous surface and atmosphere. With data analysis of ASTER on TERA, which is 15m resolution in visible and near infrared wavelengths, we found atmospheric aerosols were always large. Note that data analysis was limited in Nagoya bay, Lake Tahoe, California & La Pozuelos, La Picasa, Argentina. Thus this time we expect data analyses around isolated island and peninsula in west and south coast of Korea.

  • PDF

A hybrid algorithm of underwater structure vibration and acoustic radiation-propagation in ocean acoustic channel

  • Duan, Jia-xi;Zhang, Lin;Da, Liang-long;Sun, Xue-hai;Chen, Wen-jing
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.680-690
    • /
    • 2020
  • In ocean environment, the sound speed gradient of seawater has an important influence on far field sound propagation. The FEM/BEM is used to decouple the vibroacoustic radiation of the spherical shell, and the Green function of the virtual source chain is adopted for decoupling. For far field radiated Sound Pressure Level (SPL), the Beam Displacement Ray normal Mode (BDRM) is employed. The vibration and near-/far-field radiated SPL of spherical shell is analyzed in shallow sea uniform layer, negative/positive gradient, negative thermocline environment, and deep-sea sound channel. Results show that the vibroacoustic radiation of spherical shell acted at 300Hz can be analogous to dipole. When the radiated field of the spherical shell is dominated by large-grazing-angle waves, it can be analogous to vertically distributed dipole, and the far field radiated SPL is lower; while similar to horizontally distributed dipole if dominated by small-grazing-angle waves, and the far field SPL is high.

Long and Short Wave Radiation and Correlation Analysis Between Downtown and Suburban Area(I) - Observation of the Long and Short Wave Radiation in Summer and Winter Season of Daegu - (도심부와 교외지역의 장·단파 복사와 상관도 분석 (I) -대구지역의 동·하절기 장·단파 복사 관측과 해석 -)

  • Choi, Dong-Ho;Lee, Bu-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.94-100
    • /
    • 2013
  • The objective of this study was to compare and analyze for seasonal long short-wave radiation characteristics between downtown area and suburban area in Daegu through field observations. This study was confirmed the regional and seasonal radiation environments and it can utilize as basic data for the analysis of the urban radiation environment and the effects of urbanization. The followings are main results from this study. 1) The downward shortwave radiation showed the similar value of the radiation generally in the downtown area and the suburban area of the city during the winter and summer season. but, long-wave radiation is always higher in downtown area. 2) In case of the long-wave radiation at two stations, we observed $230{\sim}270W/m^2$ in the winter season and $415{\sim}470W/m^2$ in summer season. As a result, we can see summer season is higher than winter about two times in long-wave radiation. 3) In case of short wave radiation, there is high correlation between two stations in winter season but very low correlation between two stations in summer season because of local atmosphere unstability and etc.

Satellite Anomalies due to Spce Environment Events (우주환경 이벤트에 의한 위성의 이상현상)

  • Park, Jae-Woo;Jeong, Cheol-Oh
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.2
    • /
    • pp.102-106
    • /
    • 2011
  • Space Environment including Solar activities such as Solar explosion, Corona Mass Ejection(CMS) is always not friendly for human. Especially it may be fatal to artificial satellites. The lifetime of geostationary communication satellites are reducing due to plasma such as electrons, protons etc. emitting from Sun. This is because the active components constituting communication satellite are easily affected by plasma. Even though the radiation shielding on the components can be a way to prevent, the cost will be high. So the appropriate shielding is necessary and the study on space environment is also. In this study spacecraft anomalies will be investigated from low earth orbit to deep space spacecraft and the correlation between spacecraft anomalies and space environment events including space explosion, geomagnetic storms etc is analyzed.