• 제목/요약/키워드: High-Voltage Circuit Breaker

검색결과 136건 처리시간 0.033초

ANSI/IEEE를 적용한 초고압 차단기의 차단시험 (Breaking test of UHV circuit breaker by ANSI/IEEE standard)

  • 박승재;류형기;강영식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.467-469
    • /
    • 2003
  • IEC(International Electrotechnical Commission) 62271-100 has been adopted for the design test of circuit breaker which is used as the main protecting device of power system. But, it is also necessary to separately receive the testing certificate in accordance with ANSI/IEEE standard for getting into the american market. Up to now, several domestic companies have completed the ANSI/IEEE testing in medium circuit breaker of distribution system, but they recently started the ANSI/IEEE testing in ultra high-voltage class of transmission and substation system. This paper introduces the testing techniques and its results for the making and breaking performance of 145kV, 40kA $SF_6$ gas circuit breaker which was firstly performed in KERI(Korea Electrotechnology Institute) by the ANSI/IEEE standard.

  • PDF

고조파에 의한 저압용 차단기의 동작특성 해석 (Analysis of Active Characteristic the Low-voltage Circuit Breaker for Harmonics)

  • 최문규;정병환;박종찬;김한구;목형수;최규하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1474-1476
    • /
    • 2005
  • Because MCCB, ELB, etc. discharge both technical and economical duty, it is important that the study of circuit breaker guarantee high-performance and realize the power distribution system with reliability. Because of complexity electrical equipment, the accident with imbalance and flicker occur often according to technical improvement. However, study of accident with harmonics remains. In this paper, the essential characteristic of circuit breaker is introduced. To analysis operation of circuit breaker, theoretical model and several simulations have been performed.

  • PDF

옥내 배전선로용 아크차단기 개발에 관한 연구 (A Study on Development of Arc Fault Circuit Interrupter Used in House Distribution Line)

  • 곽동걸;최정규;박영직;김진환;손재현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.546-547
    • /
    • 2013
  • This paper proposes an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. It perceives a voltage instantaneously at the time of voltage drop. and occurrence. It is an AFCI of the new concept which operates with high reliability. The primary reason of electric fire is arc and spark. It prevents an electric fire or an electric leakage accident with quick responsiveness. Earth Leakage Circuit Breaker(ELB), Molded_case Circuit Breaker (MCCB) or Residual Current Protective Device(RCD) can not cut off electric arc or spark to be a major factor of electrical fire. This theory will be able to intercept an arc or a spark. which occurrence with periodic. Consequently It raises a reliability and validates a practicality of RCD.

  • PDF

초고압 복합소호 차단부의 열가스 거동 예측 (Prediction of Hot Gas Behavior in High Voltage Self-blast Circuit Breaker)

  • 김진범;여창호;서경보;권기영;이학성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2494-2499
    • /
    • 2007
  • Self-blast circuit breakers utilize the energy dissipated by the arc itself to create the required conditions for arc quenching during the current zero. The high-current simulation provides information about the mixing process of the hot PTFE cloud with $SF_6$ gas which is difficult to access for measurement. But it is also hard to simulate flow phenomenon because the flow in interrupter with high current, $SF_6$-PTFE mixture vapor and complex physical behavior including radiation, calculation of electric field. Using a commercial computational fluid dynamics(CFD) package, the conservation equation for the gas and temperature, velocity and electric fields within breaker can be solved. Results show good agreement between the predicted and measured pressure rise in the thermal chamber.

  • PDF

저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 고속형 전기안전 보호장치 (Electric Safety Protection Device of High Speed for Incapable Operation of ELB and MCCB Using the Low Voltage Distribution Line)

  • 곽동걸;정도영
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1925-1929
    • /
    • 2007
  • This paper is studied on a novel Electric Safety Protection Device (ESPD) of high speed for incapable operation of Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB) using the low voltage distribution line. The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is ELB and MCCB, of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a novel ESPD of high speed to trip of distribution line on electric arc or spark due to electrical fire. Some experimental results of the proposed ESPD are confirmed to the validity of the analytical results.

Development of a 170kV 50kA Capacitorless Gas Circuit Breaker

  • Park, K. Y.;K. D. Song;Y. H. Oh;W. P. Song;J. H. Kang;Park, S. W.
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권3호
    • /
    • pp.73-76
    • /
    • 2003
  • In modern EHV (Extra High Voltage) class GCBs (Gas Circuit Breakers), the interruption capability for SLF (Short Line Fault) is one of the most important aspects of performance required for GCBs. Up to now, the SLF interruption capability of EHV class GCBs was partially assisted by the adoption of capacitors able to decrease the dV/dt of the TRV (Transient Recovery Voltage), particularly the TRV on the line side. This paper describes the technique to increase the SLF interruption capability of EHV class GCBs as well as the procedure to develop capacitorless l70kV 50kA GCB.

합성시험법을 이용한 진상소전류 성능검증에 관한 고찰 (Review for verification of capacitive current performance by using synthetic testing method)

  • 박승재;김용식;박용환;김맹현;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.466-467
    • /
    • 2006
  • Several synthetic testing methods have widely been used for the performance evaluation of ultra high-voltage circuit breaker. Among these synthetic method, in the paper, capacitance switching testing method which can meet the test requirements and increase the testing capacity has been proposed. This method is made up of two separated sources of short-circuit generator for current source and L-C resonance circuit for voltage source. By using this method, KERI will perform the performance evaluation of capacitive current switching performance for the 800kV GCB(Gas Circuit Breaker).

  • PDF

분광법을 이용한 아크 플라즈마의 온도 및 성분 측정 (Measurement of a temperature and components of arc plasma with a spectroscopic method)

  • 정영우;이상엽;박홍태;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1840-1842
    • /
    • 2003
  • This paper describes an experiment of detecting a temperature and components of arc plasma of electrical circuit breaker with a spectroscopic system. The system includes an optical fiber, a monochromator which has three gratings from low to high resolution and ICCD of which time resolution is 50 ns. This system enables measuring a temperature and components of arc plasma of a circuit breaker which is generated and extinguished in a few ms. We use a Planck's law and Boltzmann Plot method for calculating a temperature of arc plasma. A Xenon lamp is used for calibrating the system and this is very important for calculating a temperature of arc plasma. In this study, Arc plasma of Ag and Cu contact was investigated and these represent the contact of low voltage and extra-ultra high voltage circuit breaker, respectively. 8 $kA_{rms}$ test current was applied with a capacitor bank.

  • PDF

$SF_6$ 가스절연개폐기의 냉가스유동해석과 전계해석을 기초로 한 차단성능평가 (Circuit Interruption Performance Evaluation of $SF_6$ GIS Based Results of Cold Flow and Electrical Field Analysis)

  • 배동진;송태헌;최영찬;이기주;김익모;강종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.89-91
    • /
    • 1999
  • The performance of circuit interruption of $SF_6$ puffer cylinder type gas circuit breaker(GCB) has been evaluated from the results of electrical insulation strength which is depend on material property, such as $SF_6$ gas density in circuit breaker tank. In order to determine circuit breaker dimension in the safety criteria. electrical field analysis has been done by finite element method. Gas density of concerned area in the circuit breaker has been calculated. In order to predict small current break performance, Electrical field analysis result must be calculated based the results of density from cold flow dynamics. The proposed method has been carried out and evaluated for 362kV class high voltage GIS.

  • PDF

주회로차단기 투입전원 위상제어를 위한 지능형 제어기 개발 (A Development of Intelligent Controller for Phase Control in Main Circuit Breaker)

  • 오용국;김재원;류준형
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.755-761
    • /
    • 2017
  • 교류 철도차량에 사용되는 주회로차단기 (Main Circuit Breaker)는 전차선 전원을 차량 내 투입 또는 차단하는 기능을 한다. 일반적으로 주회로차단기는 판토그라프와 주변압기 사이에 위치하며, 주회로차단기의 동작시점에 따라 차량에 투입되는 전원의 위상이 변화하게 된다. 투입전원의 위상에 따라 차량 내 돌입전류, 서지전압 등의 형태로 차량 전기장치 내 의도하지 않은 과도현상이 야기될 수 있으므로, 주회로차단기의 동작은 전차선 전원의 위상각에 따라 능동적으로 제어되어야 한다. 하지만 주회로차단기는 동작신호 인가 이후, 실제 개폐 동작 시까지 일정하지 않은 동작지연시간이 존재한다. 따라서 동작 지연시간을 예측하고, 이를 고려하여 주회로차단기를 개폐시점을 제어하는 지능형 제어기가 필요하다. 본 논문에서는 주회로차단기의 투입전원 위상 제어를 위하여 동작 메카니즘 및 동작 지연요소를 분석하였다. 그리고 차단기 및 구성품 별 반복동작시험을 통하여 동작 지연시간을 분석하고, 이를 예측하기 위한 이동평균 (Moving Average) 알고리즘을 제안하였다. 또한 지능형 제어기 개발 및 제작을 통하여 제안된 알고리즘을 구현하였으며, 주회로차단기와의 연동시험을 통하여 알고리즘의 성능을 검증하였다.