• Title/Summary/Keyword: High-Tech Construction

Search Result 158, Processing Time 0.023 seconds

Convergence Analysis on Policy Decision Making Factor of Local Construction Planning Phase by Using Unstructured Data in point of the Technology and Culture (비정형 데이터 분석을 통한 기술과 문화의 융합적 관점의 지역 건설기획단계 정책의사결정 영향요인 분석)

  • Park, Eun Soo;Kim, Ji Eun
    • Korea Science and Art Forum
    • /
    • v.23
    • /
    • pp.149-162
    • /
    • 2016
  • Here are background, method, scope, main contents of this research. As the interests increased in recent about the construction in complex and diverse areas, construction is locally connected to human life like to coexistence of the technology and culture. The local development should not be fragmentary construction to improve local recycling ability. Local society should be inherited by modern cultural perspective through a variety of local culture and coexistence. Effective decision making analysis is necessary to build a livable area with a combination of high-tech industry. For this reason, this paper will study the political analysis for decision making at the planning stage of construction in point of fusion of technology and culture by using unstructured data analysis. Conclusion is as in the following. Local planning stage of construction describes diverse meanings of intangible and intangible factors as political factor. Technology factors have various qualitative and quantitative factors in construction field. Understanding decision making at the planning stage of construction means not only visible 'technology factor' such as structure, method, shape, and so on, but also invisible 'culture factor' such as spirit of age, religion, learning, and life-style reflected in formation process of space, and insight of brain power about art.

A study on Reliability Analysis for Prediction Technology of Water Content in the Ground using Hyperspectral Informations (초분광정보를 이용한 지반의 함수비 예측 기술의 신뢰성 분석 연구)

  • Lee, Kicheol;Ahn, Heechul;Park, Jeong-Jun;Cho, Jinwoo;You, Seung-Kyong;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.4
    • /
    • pp.141-149
    • /
    • 2021
  • In this study, an laboratory experiment was performed for prediction technology of water content in the ground using hyperspectral information. And the spectral reflectance with a specific wavelength band was obtained according to the fine and water content. Through it, the spectral information was normalized with the spectral index of the existing literature, and the relationship with the fine and water contents and the reliability of the prediction technology were analyzed. As a result of analysis, the spectral reflectance is decreased when the water and fine contents are increased under the high water contents. In addition, the reliability of prediction technology of water content was evaluated by examining 7 different spectral index calculation methods. Among them, DVI showed relatively high prediction reliability and was superior to other calculation methods in terms of sensitivity.

Development of Concrete-Polymer Composite(II) -Physical Properties of Polymer(Resin) Concrete- (콘크리트-폴리머 복합재료 개발(II) -폴리머(레진) 콘크리트의 물성-)

  • Hwang, Eui-Hwan;Hwang, Taek-Sung;Kil, Deog-Soo
    • Applied Chemistry for Engineering
    • /
    • v.10 no.7
    • /
    • pp.1066-1072
    • /
    • 1999
  • The physical properties of polymer concrete were investigated for development of high-performance construction materials. Various specimens of polymer concrete were prepared using unsaturated polyester resin as the polymer-binder with the various dosage of calcium carbonate as microfiller (5~20 wt %) and fine aggregate(10~50 wt %). For the evaluation of the physical properties of polymer concretes, tests such as compressive strength, flexural strength, water absorption test, hot water immersion test, acid resistance test and pore size distribution analysis were conducted. As a result, it is concluded that compressive and flexural strengths of polymer concretes increased up to 4 times than those of conventional cement concrete. Whereas the compressive and flexural strengths of polymer concretes tested after hot water immersion, compared with those of polymer concretes tested before hot water immersion, decreased about 67%, 47%, respectively. By hot water immersion, total pore volume and porosity(%) of polymer concretes were remarkable increased due to decomposition of polymer binder. And also, it is showed that water absorption(%) and weight loss(%) of polymer concrete specimens by acid immersion, compared with those of ordinary portland cement concrete, decreased about 1/100, 1/27, respectively.

  • PDF

Evaluation on Behavior Characteristics of a Pocketable Expansion Material for Ground Cavity Based on Wheel Tracking Test Results (휠트래킹 시험을 통한 포켓형 지반공동 긴급복구 팽창재료의 거동특성 평가)

  • Park, Jeong-Jun;Kim, Ju-Ho;Kim, Ki-Sung;Kim, Dongwook;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.1
    • /
    • pp.75-83
    • /
    • 2018
  • This paper described a results of dynamic stability by using wheel tracking test and unconfined compression test, in order to evaluate behavior characteristics on the developed pocketable expansion material for emergency restoration of ground cavity. The wheel tracking test result showed that the settlement increment ratio of the recovered ground by the expansion material was decreased compared to the sandy ground in high load condition. That is, it was confirmed that the expansion material was able to restrain the settlement due to the material stiffness, and the same results were obtained for the dynamic stability evaluation results. From the results of unconfined compression test, the pocketable expansion material was found to be able to fully support load on the restored cavity.

Application of Macrocell Sensor System for Monitoring of Steel Corrosion in Concrete Structure Exposed to Marine Environment (해양 콘크리트구조물의 철근부식 모니터링을 위한 매크로셀 센서 시스템의 적용)

  • Lee, Seung-Tae;Moon, Dae-Joong;Kim, Wan-Jong;Moon, Jae-Heum;Kim, Hak-Soo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.4
    • /
    • pp.241-247
    • /
    • 2010
  • Corrosion of steel embedded in concrete is one of the foremost factors that affect the durability of concrete structures in marine environments. This paper presents an application technique of anode-ladder-system to evaluate corrosion behaviours of marine concrete structure. In order to investigate the behaviours quantitatively, the measurement of potential and current was performed on the concrete elements subjected to the penetration and diffusion of chloride ions. The main variable was the heights from seawater level; namely 3.7, 6.0 and 8.2 m. As a result of the monitoring, it was found that the corrosion characteristics differently behaved with the increasing height. Additionally, through migration test, the relationship between compressive strength of concrete and diffusivity of chloride ions was observed. It is suggested, ultimately, that in order to reduce or mitigate steel corrosion, both appropriate concrete cover depth and high-quality of concrete in early ages should be done.

The Comparison Analysis of Welding Techniques in Water Distribution Steel Pipes (상수도강관 용접접합의 방법별 비교분석)

  • Kim, Eung-Seok;Jeong, Won-Sik;Kim, Sung-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2859-2865
    • /
    • 2011
  • The welded connection is known as an essential factor for establishing qualified construction and/or maintenance of wrapped steel pipe. In this study, welded connection conditions in the coated pipes with large diameter (over 700 mm) in Korea water distribution systems were estimated for suggesting technically and economically available welded connection method. For the study analysis, current steel pipe usage and accident cases were investigated. In addition, the characteristics of each welded connection method and automatic or manual connection techniques were also compared and estimated. As results, automatic welded connection method is superior than manual welded connection method in aspect of pure construction cost (average 9%) or pure welded connection cost (average 13.5%). When the poor welding-working situations in Korea are considered such as high tolerance of out-of-roundness in KS regulation, a number of lap joint welded connections, the real cost benefits of automatic welded connection should be much higher than those of manual welded connections.

Structural Performance of the Modular System with Fully Restrained Moment Connections using Ceiling Bracket (천장 브래킷을 이용한 완전강접합 모듈러 시스템의 구조성능)

  • Lee, Seung-Jae;Kwak, Eui-Shin;Park, Jae-Seong;Kang, Chang-Hoon;Shon, Su-Deok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.37-44
    • /
    • 2017
  • Due to structural characteristics, construction costs and duration of a modular system would be saved by minimizing the schedule on the job site. As such, it is crucial to develop a connection that can guarantee stiffness while allowing for simple assembling. Particularly, the mid- to high-rise construction of the modular system necessitates the securing of the structural stability and seismic performance of multi-unit frames and connections, and thus, the stiffness of unit-assembled structures needs to be re-evaluated and designed. However, evaluating a frame consisting of slender members and reinforcing materials is a complicated process. Therefore, the present study aims to examine the structural characteristics of a modular unit connection based a method for reinforcing connection brackets and hinges while minimizing the loss of the cross section. Toward this end, the study modeled the beam-to-column connection of a modular system with the proposed connection, and produced a specimen which was used to perform a cycling loading test. The study compared the initial stiffness, the attributes of the hysteretic behavior, and the maximum flexural moment, and observed whether the model acquired the seismic performance, compared to the flexural strength of the steel moment frame connection that is required by the Korean Building Code. The test results showed that the proposed connection produced a similar initial stiffness value to that of the theoretical equation, and its maximum strength exceeded the theoretical strength. Furthermore, the model with a larger ceiling bracket showed higher seismic performance, which was further increased by the reinforcement of the plate.

Effects of Limestone Powder and Silica Fume on the Hydration and Pozzolanic Reaction of High-Strength High-Volume GGBFS Blended Cement Mortars (고강도 고함량 고로슬래그 혼합 시멘트 모르터의 수화 및 포졸란 반응에 미치는 석회석 미분말과 실리카퓸의 영향)

  • Jeong, Ji-Yong;Jang, Seung-Yup;Choi, Young-Cheol;Jung, Sang-Hwa;Kim, Sung-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • To evaluate the effects of limestone powder and silica fume on the properties of high-strength high-volume ground granulated blast-furnace slag (GGBFS) blended cement concrete, this study investigated the rheology, strength development, hydration and pozzolanic reaction characteristics, porosity and pore size distribution of high-strength mortars with the water-to-binder ratio of 20, 50 to 80% GGBFS, up to 20% limestone powder, and up to 10% silica fume. According to test results, compared with the Portland cement mixture, the high-volume GGBFS mixture had much higher flow due to the low surface friction of GGBFS particles and higher strength in the early age due to the accelerated cement hydration by increase of free water; however, because of too low water-to-binder ratio and cement content, and lack of calcium hydroxide content, the pozzolanic reactio cannot be activated and the long-term strength development was limited. Limestone powder did not affect the flowability, and also accelerate the early cement hydration. However, because its effect on the acceleration of cement hydration is not greater than that of GGBFS, and it does not have hydraulic reactivity unlikely to GGBFS, compressive strength was reduced proportional to the replacement ratio of limestone powder. Also, silica fume and very fine GGBFS lowered flow and strength by absorbing more free water required for cement hydration. Capillary porosities of GGBFS blended mortars were smaller than that of OPC mortar, but the effect of limestone powder on porosity was not noticeable, and silica fume increased porosity due to low degree of hydration. Nevertheless, it is confirmed that the addition of GGBFS and silica fume increases fine pores.

Hydration and Compressive Strength of High-volume Fly Ash Cement Paste (하이볼륨 플라이애시 시멘트 페이스트의 수화 및 압축강도 특성)

  • Hwang, Chul-Sung;Moon, Eun-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.156-162
    • /
    • 2017
  • Recently, researches on High-Volume Fly ash Cement(HVFC), which is replacing high portion of cement to fly ash, have been actively conducted to reduce $CO_2$ formation. Though HVFC has various advantages, low strength development in early ages is pointed out as the biggest problem in the application of fly ash. In order to overcome such limitations, this study investigated the hydration and compressive strength characteristics of HVFC paste depending on the fly ash content with the mixing ratio varying from 0 to 80 %. Experimental results show that the HVFC paste with low water-binder ratio can overcome the limitation of low compressive strength at early ages. Also, from the result of heat flow delay, 50 % of fly ash weight ratio was the critical point of the filler effect.

Development of Early-Strength of High-Strength Concrete According to Curing Temperature for Application of System Form (시스템 거푸집 적용을 위한 고강도 콘크리트의 양생온도별 조기강도 발현성상)

  • 김무한;이승훈;강석표;길배수;주지현
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.536-543
    • /
    • 2001
  • Nowadays, with high-stoned and large-sized of structures, high-strength concrete is applicable to various methods. When high-strength concrete is used jointly with system form, seizing on the development of compressive strength at early age is very important in aspect of construction process. Because system form is stripped more faster than ordinary form. But, we have little data of compressive strength before system-form is stripped, and it isn't yet established that decision criterion of the time when system-form is stripped. So this paper deals with the development of compressive strength at early age before system-form is stripped. In this study, the experimental results indicate the boundary of curing temperature and mixing factor that is able to get needful early-strength in the application of slip-form method, and curing temperature must be kept over 15 degrees in winter season.