• 제목/요약/키워드: High-Rise Residential Buildings

검색결과 181건 처리시간 0.027초

초고층 주거건물 외피시스템의 현황조사 및 분석 (Present State Investigation and Analysis of Cladding System in High rise Residential Buildings)

  • 석호태;곽현철;송승영
    • 한국주거학회논문집
    • /
    • 제15권5호
    • /
    • pp.43-50
    • /
    • 2004
  • As residential buildings becomes high rise buildings, the new cladding system was needed for structure system, and unpredictable problems were found in it. The aim of this study is to analysis the present state and find improvement of indoor environment in high rise residential building, which used curtain wall system. Then, suggest to create comfortable indoor environment for high rise residential buildings in the process of design.

초고층 주상복합 건물의 하자 발생 유형 및 분석 연구 (The analysis of defects types and patterns in high-rise residential buildings)

  • 서장우;강경인
    • 한국건축시공학회지
    • /
    • 제9권2호
    • /
    • pp.93-101
    • /
    • 2009
  • Recently, public interest in housing defects, such as construction errors, occupiers' complaints, faults in production, and so on, is increasing. In addition, the construction requirements of high-rise residential buildings have increased, due to the higher prices of urban areas, especially in metropolitan areas. While previous research has focused on the defects occurring in apartment housing complexes, research has not been carried out on the defects occurring in high-rise residential buildings. In this paper, the defects patterns and characteristics of high-rise residential buildings are examined and analyzed and a defect management plan is then suggested. In order to do this, we collected the defects data of high-rise residential buildings recorded by 2,299 of 2,327 occupants. The defect occurrence rate (DOR) in the residential area is 98.8%. The frequency rate of defect occurrence over the total defect occurrence since building completion is 63.28% during the first year, 24.63% (second year), 6.88% (third year), 2.27% (fourth year), and 2.53% (fifth year). The result of correlation analysis between work types showed that there is a relationship between the built-in furniture and electronics (F&E) and painting works, and the F&E and masonry works, such as marble finishing. We expect that this research will assist in the efforts to decrease the number of defects in high-rise buildings.

고층 주거건물 급수$\cdot$급탕설비의 사용실태에 관한 조사연구 (A Study on the Practical Use Status of Cold & Hot Water Supply System in High-rise Residential Buildings)

  • 석호태;김장한;차민철;조경재;여명석
    • 한국주거학회논문집
    • /
    • 제16권2호
    • /
    • pp.75-82
    • /
    • 2005
  • The High-rise Residential Buildings are recently consuming a lot of energy because of the vertical height rise in case of supplying cold and hot water. It is required to a appropriate solution in occurring discomfortable use and unexpected conditions of High-rise Residential Buildings on account of the difference of water supply pressure on top and bottom floor, faucet outlet pressure rise. Thus, the purpose of this study is to research on practical use status of Cold and Hot Water Supply System through Question Survey in High-rise Residential Buildings and to analyze problems.

초고층 주상복합건축물의 친환경적 디자인 방법에 대한 연구 -켄 양의 Bishopsgate Towers를 중심으로- (Study on the Eco-friendly Design Methods of the High-rise Residential-Commercial Building -Based on a work of Ken yeang, Bishopsgate Towers-)

  • 김선옥;오세규
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2005년도 추계학술대회 논문집
    • /
    • pp.283-286
    • /
    • 2005
  • In the modern city in which the high-density and complex land use is needed, high-rise residential-commercial buildings appeared as a scheme to arrange a metropolitan residence with multiple high-techs and to induce activation of the city with leading the settled population to flow into the city. And the need of the times is to actively apply the eco-friendly notion to the architecture. In this study, the works of Ken Yeang who is regarded as an eco-friendly architect to make high-rise residential-commercial buildings ecological should be focused on with analyses of eco-friendly characteristics in inside, intersection between inside and outside, and outside of his works. The result o the study would be the suggestion to design eco-friendly high-rise buildings which make the city rise in quality.

  • PDF

대학교 기숙사의 실내공기질 환경 개선에 관한 연구 (A Study on Environmental Improvement of Indoor Air Quality in University Dormitory)

  • 김호진;양정훈;석호태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1398-1405
    • /
    • 2008
  • As the structure, material and construction of building develop continuously, so the recent residential buildings are being large, high-rise and group. High-rise residential buildings consume a lot of energy on supplying cold and hot water. As well, high-rise residential buildings bring on discomfortable use and unexpected conditions on account of faucet outlet pressure rise and the difference of water supply pressure between top floor and bottom floor. Thus, the purpose of this study is to research on using conditions of cold and hot water supply system through survey and field measurement in high-rise residential buildings and to analyze problems.

  • PDF

초고층 주상복합 건물의 실내 환경 성능 향상을 위한 외피부 개선방향에 관한 연구 (A Study on the Envelop to Improve Interior Environment Performance of High-rise Residential Building)

  • 박상훈;조가영;이선우;조재훈;여명석;김광우
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.306-309
    • /
    • 2006
  • The architectural difference between the existing residence and high-rise residential building causes changes on environmental conditions such as ventilation and insulation. The object of this study is to present the improvement on envelop of high-rise residential buildings to reduce heating and cooling load. To improve the environmental performance of envelop, it is necessary to modify envelop vent system and ensure intermediate space. In this study, the shape of vents in high-rise residential buildings has been inspected, and the survey about the interior environmental conditions related to the envelop of high-rise residential building has been conducted. Environmental measurement has been done to examine out door air quality for natural ventilation.

  • PDF

초고층 주거용 건물에서의 연돌효과 영향 분석 (Analysis of the Impacts of Stack Effect in High-rise Residential Buildings)

  • 양인호;조재훈;김광우;여명석
    • 한국주거학회논문집
    • /
    • 제13권4호
    • /
    • pp.61-66
    • /
    • 2002
  • The objectives of this study are to clarify the impacts of stack effect in high-rise residential buildings and to present technical methods to reduce stack effect. For the evaluation of stack effect, architectural design guidelines were used and computer program simulations based on network model were performed. The evaluation shows that problems due to stack effect may be reduced by appropriate architectural designs, such as increase in air-tightness of building envelop, and provision of vestibules around entrance and elevator hall doors.

초고층 주거건물의 에너지 성능 분석에 관한 연구 (A Study on the Analysis of Energy Performance of High-rise Residential Buildings)

  • 석호태;김장한;정만석
    • 한국주거학회논문집
    • /
    • 제15권4호
    • /
    • pp.35-43
    • /
    • 2004
  • The environment pollution is very important problem. Even at the field of architecture, a study about method of saving energy and constructing environment friendly building will have performed with activity. But trends of Korea housing market are changed that the height of building become more higher and the level of comfort going up. Therefore, these requirements force to increase the energy usage for indoor environmental controls. Thus, the purpose of this study is to reduce the heating and cooling energy requirements of High-rise Residential Buildings by the analysis of Energy Performance. From now on, we search improvement plan for the most efficient Energy Saving at present High-rise Residential Buildings.

상업지역 내 초고층 주거건축의 주동배치방식에 따른 수평적 개방성 비교연구 - 대구지역 사례 중심으로 - (A Comparative Study on the Horizontal Openness of High-rise Residential Buildings in terms of Building Arrangement Type - Focused on the Cases in Daegu -)

  • 권종욱;박상민;박병한
    • 한국주거학회논문집
    • /
    • 제23권3호
    • /
    • pp.53-61
    • /
    • 2012
  • Openness to outside is one of the most critical advantages for high-rise buildings. However, the effect of openness can be decreased if it is blocked by other high-rise buildings, especially built within the building complex of commercial district. The purpose of this study is to identify the horizontal openness of high-rise residential buildings by comparing 3 different cases of building arrangement type. A new method of evaluation has been introduced on the basis of distance to measure the openness including the matter of securing privacy. As a result of this study, comparative analysis was possible and relatively plentiful results of analysis could be drawn out. Through the process of analysis, this study set the evaluation indicators suitable to the analysis of openness of unit households. Thereby, the results of this study are expected to be used as useful basic data in planning high-rise mixed-use buildings.

외부바람과 연돌효과의 상호작용에 의한 고층주거 건물의 연간 침기량 분포 (The annual infiltration distribution caused by wind and stack effects in high-rise residential buildings)

  • 박주현;윤성민;송두삼;김용식
    • 도시과학
    • /
    • 제8권1호
    • /
    • pp.25-31
    • /
    • 2019
  • Infiltration affects indoor environmental and air quality and energy consumptions in buildings. Especially, airflow and the infiltration are more remarkable in high-rise buildings due to the air-driving forces (stack and wind effects). Thus, it is important to understand infiltration distributions in high-rise residential buildings. In this study, the weather-driven infiltration is characterized from the viewpoint of interactions between external wind and stack effect in high-rise residential buildings. To calculate accurately the annual infiltration distributions, this study also suggests an airflow and thermal simulation method with a two-step calibration of air-leakage data. The simulated results show (1) how the interaction between stack and wind effects induce infiltration types (outdoor and interzone air infiltration) and (2) how much the interzone air infiltration (being ignored in previous studies) occurs due to the stack effect, as well as the outdoor air infiltration rates.