• 제목/요약/키워드: High-Rise Office Building

검색결과 90건 처리시간 0.027초

고층건물에서의 연돌효과 시뮬레이션 (Simulation of the Stack Effect in High-Rise Builbings)

  • 양인호;여명석;조재훈;김광우
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.456-467
    • /
    • 2002
  • The objective of this study is to analyze and evaluate the impact of the stack effect in high-rise buildings for solving the various problems resulting from it. For the evaluation of the impact of the stack effect, computer program simulations based on the network model were performed for a typical high-rise office building. The results of the simulations show that the impact caused by the stack effect is mainly dependent on building envelope air-tightness and internal airflow resistance, so the problems due to the stack effect may be solved to some extent by installing vestibules around entrance doors and doors serving elevators, and by zoning the elevators.

Performance-based Design of 300 m Vertical City "ABENO HARUKAS"

  • Hirakawa, Kiyoaki;Saburi, Kazuhiro;Kushima, Souichirou;Kojima, Kazutaka
    • 국제초고층학회논문집
    • /
    • 제3권1호
    • /
    • pp.35-48
    • /
    • 2014
  • In designing a 300 meter high skyscraper expected to be the tallest building in Japan, an earthquake-ridden country, we launched on the full-scale performance based design to ensure redundancy and establish new specifications using below new techniques. The following new techniques are applied because the existing techniques/materials are not enough to meet the established design criteria for the large-scale, irregularly-shaped building, and earth-conscious material saving and construction streamlining for reconstructing a station building are also required: ${\bullet}$ High strength materials: Concrete filled steel tube ("CFT") columns made of high-strength concrete and steels; ${\bullet}$ New joint system: Combination of outer diaphragm and aluminium spray jointing; ${\bullet}$ Various dampers including corrugated steel-plate walls, rotational friction dampers, oil dampers, and inverted-pendulum adaptive tuned mass damper (ATMD): Installed as appropriate; and ${\bullet}$ Foundation system: Piled raft foundation, soil cement earth-retaining wall construction, and beer bottle shaped high-strength CFT piles.

해외 주요 도시의 기후특성에 따른 최대공조부하 요소별 분석 (Heating and Cooling Load according to the Climatic Conditions of Foreign Cities)

  • 안승현;김종호;이정훈;이상엽;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.81-87
    • /
    • 2014
  • According to the domestic construction business will continue stagnant, many domestic construction companies are expanding their business into foreign countries. As results, building design guidelines including HVAC design for foreign countries considering the regional climate conditions are needed. Also, green building design strategies to minimize the heating and cooling load are key issue to win a contract in construction business in the world. In this study, peak heating and cooling loads were calculated for the representative cities in the world : Seoul, St. Petersburg, Singapore and Mecca. The analyzed building was a typical high-rise office building and the building envelope properties, indoor heat gain, residence and operating schedules were same in all cases. Only the weather conditions were different by cases.

업무용 고층건물 계단실의 보행속도에 관한 연구 (Vertical Evacuation Speed in Stairwell of a High-rise Office Building)

  • 정석환;윤명오
    • 한국화재소방학회논문지
    • /
    • 제29권3호
    • /
    • pp.13-20
    • /
    • 2015
  • 초고층 건축물의 수직성 증가는 더 긴 최소피난시간(Required Safety Egress Time, RSET)을 요구하게 된다. 초고층건물에선 계단을 통한 수직이동이 피난경로 상의 대부분을 차지한다. 본 연구에서는 고층 건물에서 반복된 3번의 대피훈련을 시행하고, 영상분석을 통해 피난경로 선택의 변화와 계단실 내 수직 보행속도-밀도의 함수관계를 분석했다. 또한 Pathfinder 피난시뮬레이션을 이용하여 단계적 피난의 방법에 따른 총 피난시간의 변화와 실제 훈련의 결과를 비교 분석하였다. 그 결과 반복적 피난훈련과 교육을 통해 특정 계단 이용률이 6.3%에서 39.5% 개선되었고, 각 피난경로별 피난시간도 단축됨을 확인하였다. 또한 계단실 내 수직 보행속도-밀도의 관계식이 기존의 연구결과와 매우 유사한 s = 1.004 ? 0.288D로 확인되었다. 단계적 피난의 방법에 따라 전층 동시피난에 비해 총 피난시간이 25% 이상 변화할 수 있음을 확인할 수 있었다.

Structural Design of Nakanoshima Festival Tower

  • Okada, Ken;Yoshida, Satoshi
    • 국제초고층학회논문집
    • /
    • 제3권3호
    • /
    • pp.173-183
    • /
    • 2014
  • Nakanoshima Festival Tower is a 200 m high-rise complex building which contains a renewed 2700-seat capacity concert hall known as "Festival Hall" and offices including headquarter of a news company. In order to build up an office tower on the hall which requires large open space, a giant truss system is employed. The giant trusses being composed of mega-trusses and belt-trusses support all the building weight above them and transfer the load to the outside of the hall. The building also requires high seismic resistance performance for a news company. Application of mid-story seismic isolation enables the building to satisfy high-level seismic resistance criteria.

주기 조절을 이용한 고층 건물의 풍응답 조절 설계 (Wind Induced Vibration Design for High-rise buildings through Control of Natural Period)

  • 김지은;차성희;서지현;박효선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.43-51
    • /
    • 2004
  • As the slenderness ratio of a high-rise building increases, the lateral load resisting system for the building is more often determined by serviceability design criteria. In serviceability design, the maximum drift and the level of vibration are controlled not to exceed the design criteria. Even though many drift method have been developed in various forms, no practical design method for wind induced vibration has been developed so far. Structural engineers rely upon heuristic or experience in designing wind induced vibration. Development of practical design method for wind induced vibration is required. Generally, wind induced acceleration responses are depending on several variables such as the weight density of a building, damping ratio, the natural period, and etc.. All parameters except the natural period or frequency are usually out of reach for structural engineers, then the wind acceleration response may be proportioned to the natural period. Therefore, in this paper, a wind induced vibration design method based on frequency control technique for high-rise is proposed. The method is applied to vibration design of a 25-story office building for performance evaluation.

  • PDF

보행자 레벨의 풍환경 예측 시 Canopy Model을 적용한 CFD 시뮬레이션 타당성 검증 (Validation of applying Canopy model to predict wind environment of pedestrian level by CFD simulation)

  • 정수현;홍인표;송두삼
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.345-353
    • /
    • 2012
  • Recently rapid urbanization facilitates development of high-rise building complex including apartment and office building in urban area. Many problems related with high-rise building are reported. Especially, unpleasant strong winds in pedestrian area are frequently encountered around the high-rise building. CFD simulation methods are used to analyze the wind environment of pedestrian level in high-rise building block. However the results show differences between CFD and measurement. The reason for the difference is that conventional CFD simulation couldn't consider the effect of trees, shrubs and plants which affect the wind environment. Canopy model is a solution to solve the limitation of CFD analysis. In this paper, the canopy model to predict wind environment of pedestrian level by CFD simulation will be proposed and the validity will be analyzed by comparison of measurement and CFD prediction.

  • PDF

Structual Design of a Building with High Damping Provided by Deformation Amplification Mechanisms and Tuned Viscous Mass Damper

  • Mizuki Shigematsu;Takaaki Udagawa;Satoru Nagase
    • 국제초고층학회논문집
    • /
    • 제12권3호
    • /
    • pp.215-224
    • /
    • 2023
  • This paper presents the structural design and response control system of the JR MEGURO MARC building, a 70 meters high office building with steel structure located in Tokyo (Figure 1). In order to achieve high earthquake resistance and useable office space, this building integrates a centralized response control system with deformation amplification mechanisms and tuned viscous mass dampers on the lower floor. Moreover, buckling-restrained braces (BRB) are installed on the upper floors to increase the effectiveness of centralized response control system and to reduce damage of the main frames in the event of a major earthquake. It features an efficient centralized response control system by amplifying the deformation of the dampers without creating a soft story.

A Study on the Space Reconstitution Reflecting the Characteristics of Adaptive Reuse: Focusing on High-rise Building Regeneration as a Complex Cultural Space

  • Myung-Sik Lee;Dong Hyuk Son
    • 국제초고층학회논문집
    • /
    • 제13권1호
    • /
    • pp.69-83
    • /
    • 2024
  • In this study, we focused on 'Adaptive Reuse', which has the concepts of space reconstitution and social and cultural regeneration, so that previously constructed highrise buildings can accommodate various changes in modern society, and new spatial design was developed based on the characteristics of adaptive reuse. We sought to present the concept and direction, detailed strategies, and architectural response elements of space reconstitution for the purpose of realizing the typical spatial reorganization required by modern society and seeking directions and methods of space reconstitution that can be applied to future society. The purpose is to do so.