• Title/Summary/Keyword: High-Pressure Test

Search Result 2,328, Processing Time 0.035 seconds

Flexural Properties according to Change of Polymerization Temperature of Autopolymerized Resin for Orthodontic (치과 교정용 자가중합형 Resin의 중합 온도 변화에 따른 굽힘 특성)

  • Lee, Gyu Sun
    • Journal of dental hygiene science
    • /
    • v.15 no.3
    • /
    • pp.259-264
    • /
    • 2015
  • For this experiment, specimen was manufactured by injecting polymer and monomer into silicon mold with volume ratio of 2.5:1 based on ISO 20795-2 so that average thickness, width and length of specimen would be maintained as 3.3 mm, 10.0 mm and 65.0 mm, respectively depending on spray on technique. Specimen was divided into 3 groups ($25^{\circ}C$, $40^{\circ}C$, $70^{\circ}C$) depending on polymerization temperature and 10 specimen was manufactured for each group and it was polymerized in water tank of ${\pm}1^{\circ}C$ under the setting condition of polymerization time of 15 minutes and pressure of 3 bar. After keeping specimen in distilled water of $37^{\circ}C$ for over 48 hours before experiment, flexural strength (FS) and elasticity modulus (EM) of specimen being tested by using Intron (3344; Instron; Instron). SPSS ver. 16.0 was used for analysis and post-hoc test of Scheffe was performed after using one-way ANOVA. When comparing mean value of FS of resin for orthodontics, it was represented in the range of 71.500 MPa for $25^{\circ}C$ group, 74.920 MPa for $40^{\circ}C$ group and 76.880 MPa for $70^{\circ}C$ group and difference was shown in the order of $25^{\circ}C$ group <$40^{\circ}C$ group <$70^{\circ}C$ group but such difference was not significant statistically (p=0.052). Result of EM mean value of resin for orthodontics was more polymerization temperature was high, the more was significant difference represented in the order of $25^{\circ}C$ group <$40^{\circ}C$ group <$70^{\circ}C$ group (p<0.039).

Study on the channel of bipolar plate for PEM fuel cell (고분자 전해질 연료전지용 바이폴라 플레이트의 유로 연구)

  • Ahn Bum Jong;Ko Jae-Churl;Jo Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.15-27
    • /
    • 2004
  • The purpose of this paper is to improve the performance of Polymer electrolyte fuel cell(PEMFC) by studying the channel dimension of bipolar plates using commercial CFD program 'Fluent'. Simulations are done ranging from 0.5 to 3.0mm for different size in order to find the channel size which shoves the highst hydrogen consumption. The results showed that the smaller channel width, land width, channel depth, the higher hydrogen consumption in anode. When channel width is increased, the pressure drop in channel is decreased because total channel length Is decreased, and when land width is increased, the net hydrogen consumption is decreased because hydrogen is diffused under the land width. It is also found that the influence of hydrogen consumption is larger at different channel width than it at different land width. The change of hydrogen consumption with different channel depth isn't as large as it with different channel width, but channel depth has to be small as can as it does because it has influence on the volume of bipolar plates. however the hydrogen utilization among the channel sizes more than 1.0mm which can be machined in reality is the most at channel width 1.0, land width 1.0, channel depth 0.5mm and considered as optimum channel size. The fuel cell combined with 2cm${\times}$2cm diagonal or serpentine type flow field and MEA(Membrane Electrode Assembly) is tested using 100W PEMFC test station to confirm that the channel size studied in simulation. The results showed that diagonal and serpentine flow field have similarly high OCV and current density of diagonal (low field is higher($2-40mA/m^2$) than that of serpentine flow field under 0.6 voltage, but the current density of serpentine type has higher performance($5-10mA/m^2$) than that of diagonal flow field under 0.7-0.8 voltage.

  • PDF

Evaluation of the Potential of Nitrogen Plasma to Cosmetics (질소 플라즈마의 화장품 가능성 평가)

  • Lee, So Min;Jung, So Young;Brito, Sofia;Heo, Hyojin;Cha, Byungsun;Lei, Lei;Lee, Sang Hun;Lee, Mi-Gi;Bin, Bum-Ho;Kwak, Byeong-Mun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.3
    • /
    • pp.189-196
    • /
    • 2022
  • Plasma refers to an ionized gas that is often referred to as "the fourth phase of matter", following solid, liquid, and gas. Plasma has traditionally been utilized for industrial applications such as welding and neon signs, but its promise in biomedical fields such as cancer treatment and dermatology has lately been recognized. Indeed, due to its beneficial effects in promoting collagen production, improving skin tone, and eliminating harmful bacteria in the skin, plasma treatment constitutes an important target for dermatological research. In this study, a plasma device for cosmetic manufacturing based on nitrogen, the main component of the atmosphere, was designed and assembled. Moreover, nitric oxide (NO) was selected since is easier to follow and evaluate than other nitrogen plasma active species, and its contents were measured to perform a quantitative and qualitative evaluation of plasma. First, an injection method, using different proximities labeled "sinking" and "non sinking" treatments, was performed to test the most efficient plasma treatment method. As a result, it was observed that the formulation obtained by a non sinking treatment was more effective. Furthermore, toner and ampoule were selected as cosmetics formulations, and the characteristics of the formulation and changes in the injected plasma state were observed. In both formulations, the successful injection of NO plasma was 2 times higher in toner formulation than ampoule formulation, and it gradually decreased with time, having dissipated after a week. It was confirmed that the nitrogen plasma used did not affect the stability of the toner and ampoule formulations at low temperature (4 ℃), room temperature (25 ℃), and high temperature (37 ℃ and 50 ℃) conditions. The results of this study demonstrate the potential of plasma cosmetics and highlight the importance of securing the stability of the injected plasma.

Development of Near-Isogenic Line of japonica Rice Cultivar Saenuri without Lipoxygenase-3 (새누리 벼 품종 배경 lipoxygenase-3 결핍 자포니카 근동질계통 개발)

  • Park, Hyun-Su;Lee, Keon-Mi;Kim, Ki-Young;Kim, Jeong-Ju;Shin, Woon-Cheol;Baek, Man-Kee;Kim, Choon-Song;Park, Seul-Gi;Lee, Chang-Min;Suh, Jung-Pil;Cho, Young-Chan
    • Korean Journal of Breeding Science
    • /
    • v.51 no.3
    • /
    • pp.190-200
    • /
    • 2019
  • It is reported that the absence of lipoxygenase-3 (LOX-3) may contribute to a reduction in stale flavor after the storage of rice. To improve the quality of stored rice of the Korean japonica rice cultivar, we conducted a breeding program to develop near-isogenic rice without LOX-3 in the genetic background of Saenuri, a mega variety of Korea. In the first step of the breeding program, we used a donor parent of LOX-3 null, Daw Dam, and a recurrent japonica parent, Sindongjin, to develop HR27873-AC12 by backcross (BC1), color test for introgression of lox-3, and anther culture for rapid fixation. In the second step, we used the donor parent, HR27873-AC12, and the recurrent parent, Saenuri, to develop HR28896-31-3-1-1 by backcross (BC1), marker-assisted selection (MAS) for lox-3, and phenotypic selection (PS) for agronomic traits. Finally, in the third step, we developed HR30960-186-2-1-2-1 (Jeonju624), derived from a cross between Saenuri and HR28896-31-3-1-1, by MAS for lox-3 and PS with high selection pressure for agronomic characteristics. Jeonju624 was confirmed with the introgression of lox-3 by molecular marker. Jeonju624 was a mid-late maturing rice with similar agronomic characteristics to Saenuri, lodging tolerance with short culm, erect plant architecture, and resistance to bacterial blight and rice stripe virus. The yield components of Jeonju624 were mostly similar to Saenuri, except for the 1,000-grain weight of brown rice. The appearance of the grain of Jeonju624 was better than that of Saenuri, and the characteristics of cooked rice were similar to those of Saenuri. In the genetic background analysis using 406 KASP (Kompetitive Allele-Specific PCR) markers, Jeonju624 was confirmed to be the near-isogenic line (NIL) of Saenuri with a 95.8% recovery rate. Jeonju624 is the NIL of Saenuri without LOX-3, and overcomes the linkage drag of Daw Dam with similar agronomic characteristics and genetic background to Saenuri. Jeonju624 can be utilized as a practical cultivar to improve the quality of stored rice, breeding material for the introgression of lox-3, and genetic material to elucidate the effect of introgressed genes.

The Purpose and background of this study (노인질환에 대한 한양방동시종합검진 결과에 대한 보고)

  • Gwon, Gyeong-Suk;Lee, Tae-Hwan;Song, Jeong-Mo;Kim, In-Seop;Yun, Ho-Yeong;Im, Jun-Gyu
    • The Journal of Korean Medicine
    • /
    • v.15 no.2 s.28
    • /
    • pp.9-27
    • /
    • 1994
  • This study is to analyze of senile disease status and the social problem according to increased old ages, and then to find distributions of old man's diseases and health status efficiency of oriental-occidental contemporary health examination. And it is the first oriental-occidental contemporary health examination of old man performed by JeonJu Woosuk University Oriental Medicine Hospital and Woosuk-Clinic in nation. Methods The objects in this research are 641's old man of KimJe Gun's over 60's years performed medical examination at JeonJu Woosuk University Oriental- Mmedicine-Hospital and Woosuk-Clinic by oriental-occidental medical contemporary exam., from 1994, 24th June till 1994. 13th July. The 1st occident medical examination methods were consisted of chest x-ray check. blood and urine exam., measurement of blood pressure, visual power and audiometry. The Oriental medical examination methods were consisted of four diagnostics (望,聞,問,切), present illness. chief complaint, past history, families history, social history by question and SA Sang constitution test index. The results and conclusions The results and conclusions are the next: 1. In order of distribution. the athletic disease (75.8%),the digestive disease(43.4%), the circulatory disease(41.5%), the respiratory disease(22.3%), EENT disease(8.1%), the endocrinopathy(5.6%), and the genito-urinary disease(5.3%) are the results of the object about 641's old man, by the oriental-occidental medicine's contemporay exam. 2. Distribution of disease distiction are lumbago. gastritis and peptic ulcer. knee joint pain. heart disease. hypertension. chronic bronchitis. asthma. anemia. DM. Tbc. visual disturbance. CVA. etc in order. 3. Disease distribution according to age is almost high incident in 60-75years. Disease incidence is decreased except E.E.N.T disease in over 76years. 4. The relationships of disease and family history are: the 25.0% of CVA pts. has family history and the 11.6% of hypertension pts has family history. so they showed high relative family history. In addition the 5.6% of TBC pts. and the 2.6% of DM pts. have family history. 5. The relationships of disease and drinking are: Drinking proportion is the 36.4% in respiratory disease pts. the 34.7% in hypertension pts. the 33.3% in heart disease pts.. the 28.4% in digestive disease pts.. but because of no surveying drinking amount we can't know the absolut relationships of disease and drinking. 6. The relationships of Disease and smoking are: Smoking proportion is the 44.1% in respiratory disease pts.. the 38.0% in Heart disease pts.. the 29.8% in Hypertension pts.. but because of no surveying of smoking amount. we can't know the absolut relationships of disease and smoking. 7. Distribution of Sasang constitution is : Tae-eum-in 44.8%. So-yang-in 30.7%. So-eum-in 24.6%. Tae-yang-in 0.0%. And disease distribution of Sasang constitution distinction is ; Tae-eum-in has high incidence of circulation disease(50.0%) and respiratory disease(23.1%).So-yang-in has high incidence of athletics disease(77.7%) and EENT disease(12.2%), So-eum-in has high incidence of digestive disease(65.8%). 8. Distribution of abnormal result in occidental medical examination and oriental-occidental contemporal exam result is considerably different. This is the reason of needing oriental medicine exam, for characteristics of Senile. I think that the oriental-occidental contemporary examination in old man is much more effecient than only occident medical examination. This oriental-occidental contemporary examination has many defects because it is the first practice. To participate in the public health program efficiently. I think that we must improve lots of problems and present the model of the oriental-occidental contemporary examination and the project of oriental medicine's for public health.

  • PDF

The hydrodynamic characteristics of the canvas kite - 1. The characteristics of the rectangular, trapezoid canvas kite - (캔버스 카이트의 유체역학적 특성에 관한 연구 - 1. 사각형 캔버스 카이트의 특성 -)

  • Bae, Bong-Seong;Bae, Jae-Hyun;An, Heui-Chun;Lee, Ju-Hee;Shin, Jung-Wook
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.3
    • /
    • pp.196-205
    • /
    • 2004
  • As far as an opening device of fishing gears is concerned, applications of a kite are under development around the world. The typical examples are found in the opening device of the stow net on anchor and the buoyancy material of the trawl. While the stow net on anchor has proved its capability for the past 20 years, the trawl has not been wildly used since it has been first introduced for the commercial use only without sufficient studies and thus has revealed many drawbacks. Therefore, the fundamental hydrodynamics of the kite itself need to ne studied further. Models of plate and canvas kite were deployed in the circulating water tank for the mechanical test. For this situation lift and drag tests were performed considering a change in the shape of objects, which resulted in a different aspect ratio of rectangle and trapezoid. The results obtained from the above approaches are summarized as follows, where aspect ratio, attack angle, lift coefficient and maximum lift coefficient are denoted as A, B, $C_L$ and $C_{Lmax}$ respectively : 1. Given the rectangular plate, $C_{Lmax}$ was produced as 1.46${\sim}$1.54 with A${\leq}$1 and 40$^{\circ}$${\leq}$B${\leq}$42$^{\circ}$. And when A${\geq}$1.5 and 20$^{\circ}$${\leq}$B${\leq}$22$^{\circ}$, $C_{Lmax}$ was 10.7${\sim}$1.11. Given the rectangular canvas, $C_{Lmax}$ was 1.75${\sim}$1.91 with A${\leq}$1 and 32$^{\circ}$${\leq}$B${\leq}$40$^{\circ}$. And when A${\geq}$1.5 and 18$^{\circ}$${\leq}$B${\leq}$22$^{\circ}$, $C_{Lmax}$ was 1.24${\sim}$1.40. Given the trapezoid kite, $C_{Lmax}$ was produced as 1.65${\sim}$1.89 with A${\leq}$1.5 and 34$^{\circ}$${\leq}$B${\leq}$44$^{\circ}$. And when A=2 and B=14${\sim}$48, $C_L$ was around 1. Given the inverted trapezoid kite, $C_{Lmax}$ was 1.57${\sim}$1.74 with A${\leq}$1.5 and 24$^{\circ}$${\leq}$B${\leq}$36$^{\circ}$. And when A=2, $C_{Lmax}$ was 1.21 with B=18$^{\circ}$. 2. For a model with A=1/2, an increase in B caused an increase in $C_L$ until $C_L$ has reached the maximum. Then there was a tendency of a gradual decrease in the value of $C_L$ and in particular, the rectangular kite showed a more rapid decrease. For a model with A=2/3, the tendency of $C_L$ was similar to the case of a model with A=1/2 but the tendency was a more rapid decrease than those of the previous models. For a model with A=1, and increase in B caused an increase in $C_L$ until $C_L$ has reached the maximum. Soon after the tendency of $C_L$ decreased dramatically. For a model with A=1.5, the tendency of $C_L$ as a function of B was various. For a model with A=2, the tendency of $C_L$ as a function of B was almost the same in the rectangular and trapezoid model. There was no considerable change in the models with 20$^{\circ}$${\leq}$B${\leq}$50$^{\circ}$. 3. The tendency of kite model's $C_L$ in accordance with increase of B was increased rapidly than plate models until $C_L$ has reached the maximum. Then $C_L$ in the kite model was decreased dramatically but in the plate model was decreased gradually. The value of $C_{Lmax}$ in the kite model was higher than that of the plate model, and the kite model's attack angel at $C_{Lmax}$ was smaller than the plate model's. 4. In the relationship between aspect ratio and lift force, the attack angle which had the maximum lift coefficient was large at the small aspect ratio models, At the large aspect ratio models, the attack angle was small. 5. There was camber vertex in the position in which the fluid pressure was generated, and the rectangular & trapezoid canvas had larger value of camber vertex when the aspect ratio was high, while the inverted trapezoid canvas was versa. 6. All canvas kite had larger camber ratio when the aspect ratio was high, and the rectangular & trapezoid canvas had larger one when the attack angle was high.

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF

A Study on Development of New Products by Old Chicken Meat (노폐계(老廢鷄)를 이용(利用)한 육제품(肉製品) 개발(開發)에 관한 연구(硏究))

  • Han, Sung Wook;Lee, Kyu Seung;Chang, Kyu Sup;Jeon, Chang Kie
    • Korean Journal of Agricultural Science
    • /
    • v.7 no.2
    • /
    • pp.87-102
    • /
    • 1980
  • In order to investigate the utilization probability of two years old laying hen for W.L. and R.I.R. breeds, carcass weight and percentage were examined and dried old chicken meat products were manufactured for experiments. The results obtained are as follows. 1. Average living body weight were 1,635.40g for the W.L. breeds and 2,289.29g for the R.I.R. breeds and percentage carcass and lean meat for the W.L. were 58.73% and 43.95%, for the R.I.R. 60.34%, 41.98%, respectively. 2. In constitution percentage of carcass on different parts for W.L. and R.I.R. breeds, head were 4.13% and 3.94%, wing 9.97% and 8.62%, breast 32.54% and 20.94%, back 11.35% and 9.75%, thigh 30.75% and 31.34%, hypordermic fat 11.37% and 17.34%, respectively. 3. In constitution percentage of lean meat on different parts for W.L. and R.I.R. breeds, head were 4.03% and 3.95%, wing 9.47% and 9.79%, breast 39.37% and 38.14%, back 11.24% and 9.40%, thigh 36.16% and 38.74%, respectively. 4. In chemical composition of old chicken meat for W.L. breed, moisture was 68.18%, crude protein 22.80%, crude fat 2.70%, extract 5.15% and crude ash 1.18% and for R.I.R. breed, moisture was 68.04%, crude protein 22.18%, crude fat 3.13%, extract 5.45% and crude ash 1.21%. 5. Weight loss in steaming for W.L. at $121^{\circ}C$ for 30min., 60min., and 90min. were 54.91, 56.43 and 58.42%, respectively, and for R.I.R. were 45.23, 47.68 and 49.68%, respectively. 6. The yield of old chicken meat product per a hen were 253.01g for W.L. and 368.64g for R.I.R., the ratio for fresh meat weight and for carcass weight were 35.47% and 26.34% for W.L. breed and 38.25 and 26.83% for R.I.R. breed. 7. In chemical composition of old chicken meat product for W.L., moisture was 16.69%, crude protein 66.16%, crude fat 12.81%, crude ash 4.35%, and R.I.R., moisture 16.11%, crude protein 65.95%, crude fat 13.78% and crude ash 4.57%. 8. To investigate the physical properties which was main factor affecting the product quality, tensile strength, tear strength and elongation rate were measured. The adhesive force of the product made under pressure of $70kg/cm^2$ was similar to those of chipo which was the control product. 9. When measured the color of each protein product, lightness of the product pressed at $70kg/cm^2$ was better than that at $35kg/cm^2$, and the lightness of breast muscle product at $70kg/cm^2$ and chipo was not significant as 16.7% and 16.4%, respectively. Dominant wavelength of product pressed at $70kg/cm^2$ was very similar to chipo which was yellowish orange. 10. In the results of sensory evaluation test containing taste, color, chewing texture and oder of the meat product, when index of chipo as control product was 100, index of breast meat product was higher than that as 118.4, but miscellaneous product was 99.7 and thigh product was 96.2. 11. Summing up the results written above, the meat product utilizing two years old laying hen was compared favorably with its similar food such as chipo on the point of nutrition and physical properties as high protein food, therefore, it was thought that industrialization must be highly appropriate.

  • PDF