• Title/Summary/Keyword: High-Precision

Search Result 6,194, Processing Time 0.036 seconds

An Empirical Study on the Success Factors of Korean Venture Firms: The Suggestion of the Integrated Model Utilizing Secondary Data (한국 벤처기업의 성공요인에 관한 실증적 연구: 2차 자료를 활용한 통합적 모형의 제시)

  • Koh, InKon
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.13 no.2
    • /
    • pp.1-13
    • /
    • 2018
  • This study examines the relationship between the organizational general characteristics (industry, size, location, development stage, and company age) and success factors of Korean venture firms using secondary data. Among the industries with the highest sales figures in 2016 are food / fiber / (non) metals, and the smallest category was software development. The sectors with the highest net profit were computer / semiconductor / electronic components, and the smallest category was telecommunication equipment / broadcasting equipment. The industries with the largest sales growth rate are IT / broadcasting services and software development. The industries with the highest net profit margin of sales are energy / medical / precision, and the smallest is telecommunication equipment / broadcasting equipment. In terms of the number of employees, venture firms with more than 100 employees have the largest sales and net profit, with employees between 1 and 9 have the smallest. However, these results are predictable. In general, the number of employees is highly correlated with sales and net profit. Rather, the sales growth rate and the net profit margin of sales may be meaningful. In particular, with employees between 50 ~ 99, the growth rate of sales and the net profit margin of sales were high. In terms of location, Seoul / Incheon / Gyeonggi were the regions with the highest sales and Daejeon / Sejong / Chungcheong / Gangwon were the least regions. Gwangju / Jeolla / Jeju and Seoul / Incheon / Gyeonggi were almost similar in the areas with the largest net profit. However, Daejeon / Sejong / Chungcheong / Gangwon had the lowest net profit. Unusually, the areas with the highest sales growth rate and the highest net profit margin of sales were Gwangju / Jeolla / Jeju, and the smallest areas were Busan / Jeonnam / Ulsan In the relationship between the stage of development and the performance of the company, the sales of maturity and decline stages were the highest and establishing stage was the lowest. Net profit was also the highest in mature stage and the smallest in establishing stage. The sales growth rate shows a typical pattern in the order of establishing stage, early growth stage, high growth stage, maturity stage, and decline stage. In terms of business performance, sales and net profit are the highest with 21 years or more of company age, and the smallest is less than 3 years. In addition, the sales growth rate was the highest in three years or less, and the net profit margin of sales was the highest in 4 to 10 years. This study can present lots of useful implications by suggesting integrated research model and examining the success factors of Korean venture firms and presenting the application methods of secondary data in analyzing the current status of venture industry in Korea.

DEVELOPMENT OF A LYMAN-α IMAGING SOLAR TELESCOPE FOR THE SATELLITE (인공위성 탑재용 자외선 태양카메라(LIST) 개발)

  • Jang, M.;Oh, H.S.;Rim, C.S.;Park, J.S.;Kim, J.S.;Son, D.;Lee, H.S.;Kim, S.J.;Lee, D.H.;Kim, S.S.;Kim, K.H.
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.3
    • /
    • pp.329-352
    • /
    • 2005
  • Long term observations of full-disk Lyman-o irradiance have been made by the instruments on various satellites. In addition, several sounding rockets dating back to the 1950s and up through the present have measured the $Lyman-{\alpha}$ irradiance. Previous full disk $Lyman-{\alpha}$ images of the sun have been very interesting and useful scientifically, but have been only five-minute 'snapshots' obtained on sounding rocket flights. All of these observations to date have been snapshots, with no time resolution to observe changes in the chromospheric structure as a result of the evolving magnetic field, and its effect on the Lyman-o intensity. The $Lyman-{\alpha}$ Imaging Solar Telescope(LIST) can provide a unique opportunity for the study of the sun in the $Lyman-{\alpha}$ region with the high time and spatial resolution for the first time. Up to the 2nd year development, the preliminary design of the optics, mechanical structure and electronics system has been completed. Also the mechanical structure analysis, thermal analysis were performed and the material for the structure was chosen as a result of these analyses. And the test plan and the verification matrix were decided. The operation systems, technical and scientific operation, were studied and finally decided. Those are the technical operation, mechanical working modes for the observation and safety, the scientific operation and the process of the acquired data. The basic techniques acquired through the development of satellite based solar telescope are essential for the construction of space environment forecast system in the future. The techniques which we developed through this study, like mechanical, optical and data processing techniques, could be applied extensively not only to the process of the future production of flight models of this kind, but also to the related industries. Also, we can utilize the scientific achievements which are obtained throughout the project And these can be utilized to build a high resolution photometric detectors for military and commercial purposes. It is also believed that we will be able to apply several acquired techniques for the development of the Korean satellite projects in the future.

Study on Strain Measurement of Agricultural Machine Elements Using Microcomputer (Microcomputer를 이용(利用)한 농업기계요소(農業機械要素)의 Strain 측정(測定)에 관(關)한 연구(硏究))

  • Kim, Kee Dae;Kim, Tae Kyun;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.8 no.1
    • /
    • pp.90-96
    • /
    • 1981
  • To design more efficient agricultural machinery, the accurately measuring system among many other factors is essential. A light-beam oscillographic recorder is generally used in measuring dynamic strain but it is not compatible with the extremely high speed measuring system such as 1,000 m/s, also is susceptable to damage due to vibration while using the system in field. The recorder used light sensitive paper for strip chart recording. The reading and analysis of data from the strip charts is very cumbersome, errorneous and time consuming. A microcomputer was interfaced with A/D converter, microcomputer program was developed for measuring, system calibration was done and the strain generated from a cantilever beam vibrator was measured. The results are summarized as follows. 1. Microcomputer program was developed to perform strain measuring of agricultural machine elements and could be controled freely the measuring intervals, no. of channels and no. of data. The maximum measuring speed was $62{\mu}s$. 2. Calibration the system was performed with triangle wave generated from a function generator and checked by an oscilloscope. The sampled data were processed using HP 3000 minicomputer of Chungnam National University computer center the graphical results were triangle same as input wave and so the system have been out of phase distorsion and amplitude distorsion. 3. The strain generated from a cantilever beam vibrator which has free vibration period of 0.019 second were measured by the system controlled to have l.0 ms of time interval and its computer output showing vibration curve which is well filted to theoretical value. 4. Using microcomputer on measuring the strain of agricultural machine elements could not only save analyzing time and recording papers but also get excellent adaptation to field experiment, especially in measurement requiring high speed and good precision.

  • PDF

Analysis and verification of vitamin B12 in animal foods for update of national standard food composition table (국가표준식품성분표 개정을 위한 동물성 식품 비타민 B12 분석 및 검증)

  • Jeong, Yon Na;Park, Su-Jin;Lee, Sang Hoon;Choi, Youngmin;Choi, Kap Seong;Chun, Jiyeon
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.4
    • /
    • pp.317-324
    • /
    • 2020
  • In order to create the national food nutrient database, a total of 41 animal foods (ham, seafood, edible insects and eggs) were analyzed for their vitamin B12 content and the applied immunoaffinity-HPLC was verified. Ham vitamin B12 contents were 0.30-0.65 ㎍/100 g. Seafood showed relatively high vitamin B12 level, where the values of fermented clam were the highest (26.80 ㎍/100 g) followed by fermented pollack roe. Vitamin B12 was not detected in silkworm pupae and beetles, while relatively high levels were found in the two-spotted cricket imago (6.70 ㎍/100 g). Chicken and quail egg yolk had roughly 100- and 30-times higher vitamin B12 levels as compared to their egg white. Vitamin B12 contents in quail and chicken eggs were significantly enhanced by boiling (p<0.05). Results based on accuracy (97-102% recovery) and precision (<5% RSD) indicate that this study provides reliable vitamin B12 information on animal foods consumed in Korea.

Basic Studies for the Breeding of High Protein Rice. I. Comparison of the analytical methods for the measurement of the protein content in the brown rice (수두 고단백 계통육성을 위한 기초적 연구 I. 계통육성을 위한 조단백질 분석법의 비교)

  • Mun-Hue Heu;Hak-Soo SUH
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.12
    • /
    • pp.1-5
    • /
    • 1972
  • In order to compare the analytical efficiency of the Kjeldahal, Dye binding and Biurett method for the determination of nitrogen content in the brown rice, correlation coefficients were calculate with the analytical data obtained by the above mentioned 3 different methods for the brown rice of 36 varieties or lines grown at 5 different nitrogen levels (0, 7.5, 15.0, 22.5 and 30.0kg/10a). Analysis of variance were made for the data of 6 varieties among those 36, and compared the precision of the data obtained by the 3 analytical methods. The expenditure (in terms of chemicals and labour) required for the 3 methods are also compared. The results are summarized as follows; 1. The correlation between D. B. C. and Kjeldahl value were generally more significant than the correlation between the value of Biurett and the value of Kjeldahl. But, the D. B. C. method generally overestimates than the Kjeldahl method at both extreme low and extreme high nitrogen contents, and the Biurett method includes more dispersed error than other two methods, though the optical values are parallel to the Kjeldahl nitrogen values at any levels of nitrogen applied. 2. The varietal difference in nitrogen value obtained by the 3 methods were different at the different nitrogen level applied. That is the interaction between variety and analytical method, and between the nitrogen level and analytical method were significant statistically. 3. The coefficient of variance (C, V.) was largest in the data analyzed by Biurett method and next in the data analayred by D. B. C. method. In the data analyzed by Biurett, the C. V. increased along onglong increase of nitrogen applied. But, in the data obtained by D. B. C. or Biurett the C. V. increased along the decrease of nitrogen applied. 4. From the comparison of the expenditure (in terms of chemicals and labour) required for the analysis of 100 samples by 3 methods, it was noticed that, the Biurett or D. B. C. method largely curtail the chemical expenditure and labour costs. Especially the Biurett method could curtail more labour costs.

  • PDF

Development of Rapid Analytical Method of Forbidden Medicines in Dietary Supplements Using LC-ESI-Tandem MS (LC-ESI-tandem MS를 이용한 기능성표방식품 중 부정유해물질 신속검사체계 개발)

  • Kim, Hee-Yun;Jang, Young-Mi;Joo, Hyun-Jin;Jung, Young-Hyun;Lee, Myoung-Sook;Park, Jong-Seok;Lee, Kwang-Ho;Lee, Hwa-Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.372-379
    • /
    • 2007
  • A high-performance liquid chromatography-electrospray ionization (HPLC-ESI) tandem MS was developed for the rapid and simultaneous determination of forbidden medicines in dietary supplements. Thirteen medicinal components such as PDE-5 inhibitors and their analogues, and the newly identified dimethylsildenafil and xanthoanthrafil, were included in this study. After tentative standardization of molecular ions in both polarities using thirteen references on the mass spectrometer, with ESI-continuous infusion via the syringe pump method, the relative intensity of the ions present in the resulting spectra was quantitatively compared. From the results, the ion mode was selected depending on each reference's characteristics. A HPLC method coupled with the ESI mode was developed considering the matrix effect and interference depending on the type of sample. The validation test of the developed method was followed by carrying out precision, accuracy, recovery, sensitivity and linearity, etc. The method showed sufficiently high sensitivity, reproducibility, and specificity, and produced 4 times faster results when compared with the existing HPLC/UV method for the determination of forbidden compounds in dietary supplements.

Simultaneous HPLC Determination of Marker Compounds for the Standardization of Hedyotis diffusa (백운풀의 지표성분 설정 및 품질표준화를 위한 정량 분석법)

  • Bang, Han-Yeol;Yang, Eun-Ju;Kim, Jeong-Ah;Song, Kyung-Sik
    • Journal of Life Science
    • /
    • v.23 no.8
    • /
    • pp.1025-1031
    • /
    • 2013
  • From a 95% ethanolic extract of H. diffusa, four marker compounds (HD1~HD4) were isolated, which were relatively unique and exist in comparably high contents. The structures of marker compounds were identified as digitolutein (1), 2-hydroxy-3-methylanthraquinone (2), (E/Z)-6-O-p-coumaroyl scandoside methyl ester (4:1 mixture) (3), and (E/Z)-6-O-p-methoxycinnamoyl scandoside methyl ester (4:1 mixture) (4), respectively, on the basis of $^{13}C$ and $^1H$-NMR analyses. The calibration curves of marker compounds showed high linearity, as their correlation coefficient ($R^2$) were in the range of 0.9991~0.9999. In addition, the limit of detection (LOD) and the limit of quantification (LOQ) were $0.03{\sim}0.07{\mu}g/ml$ and $0.099{\sim}0.231{\mu}g/ml$, respectively. The intra-day/inter-day precision and accuracy were 0.23~2.00%/0.25~1.16% and 94.60~108.44%/94.73-110.23%, respectively. The optimal HPLC conditions for the simultaneous quantification of HD1~HD4 were as follows: stationary phase; Merck Chromolith RP-18e ($100{\times}4.6mm$, $5{\mu}m$), column temp.; room temperature, UV detection at 280 nm, flow rate; 2.0 ml/min, injection volume; $10{\mu}l$, mobile phase; start with the mixture of 80% solvent A ($H_2O$ containing 0.5% acetic acid) and 20% solvent B (methanol containing 0.5% acetic acid) and gradually decrease solvent A to 40% in 9 min., then retain this condition to 18 min. Under the HPLC condition, the four marker compounds 1~4 were successfully separated without any interference of other constituents. The results obtained in this study are expected to be helpful for the development of nutraceutics and natural medicines and for the quality control of this plant.

An Inter-Laboratory Comparison Study on Chlorophyll a Determination in Seawater (해수 중 엽록소 a 측정방법에 대한 실험실 간 비교연구)

  • Moon, Cho-Rong;Kang, Dong-Jin;Park, Mi-Ok;Noh, Jae Hoon;Yoo, In-Jae;Moon, Jeong-Eon;Shin, Kyung-Hoon;Kim, Yun Sook;Choi, Joong-Ki;Suh, Young Sang
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.1
    • /
    • pp.76-87
    • /
    • 2014
  • Chlorophyll a in seawater which is an indicator of phytoplankton biomass and primary production is determined by High Performance Liquid Chromatography (HPLC), Fluorometry and Spectrophotometry. In this study, various methods for chlorophyll a determination in seawater are compared using in situ seawater samples from Korean seas. Three inter-laboratory comparison campaigns were carried out using chlorophyll a standard samples (R0) and in situ seawater samples, collected from the East China Sea (R1) and the East Sea (R2). 6 laboratories by HPLC methods, 4 laboratories by fluorometry, and 3 laboratories by spectrophotometry participated. Precisions, defined as the coefficient of variation (CV) were within 9% in standard samples, 0.8~20% (average: 6.1%) in R1, 4~21% (average: 13.2%) in R2. Discrepancy in three methods was approximately 20% within the range of the sample homogeneity intended the laboratory precision (R1: 8%, R2: 15%). The discrepancy in laboratories was greater than the discrepancy in methods. The chlorophyll a concentrations can be produced within 20% discrepancy in spite of using different methods. It is recommended to consider this 20% discrepancy when using the chlorophyll a data produced by different laboratories and different methods.

NIRS Calibration Equation Development and Validation for Total Nitrogen Contents Field Analysis in Fresh Rice Leaves (벼 생엽의 질소함량 현장분석을 위한 NIRS 검량식 개발 및 검증)

  • Song, Young-Eun;Lee, Deok-Ryeol;Cho, Seong-Hyun;Lee, Ki-Kwon;Jeong, Jong-Seong;Gwon, Yeong-Rip;Cho, Kyu Chae
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.58 no.3
    • /
    • pp.301-307
    • /
    • 2013
  • This study was evaluated high end research grade Near Infrared Reflectance Spectrophotometer (NIRS) to field grade multiple Near Infrared Reflectance Spectrophotometer (NIRS) for rapid analysis at fresh rice leaf at sight with 238 samples of fresh rice leaf during year 2012, collected Jeollabuk-do for evaluate accuracy and precision between instruments. Firstly collected and build database high end research grade NIRS using with 400 nm ~ 2500 nm during from year 2003 to year 2009, seven years collected fresh rice leaf database then trim and fit to field grade NIRS with 1200 nm ~ 2400 nm then build and create calibration, transfer calibration with special transfer algorithm. The result between instruments was 0.005% differences, rapidly analysis for chemical constituents, Total nitrogen in fresh rice leaf within 5 minutes at sight and the result equivalent with laboratory data. Nevertheless last during more than 8 years collected samples for build calibration was organic samples that make differentiate by local or yearly bases etc. This strongly suggest population evaluation technique needed and constantly update calibration and maintenance calibration to proper handling database accumulation and spread out by knowledgable control laboratory analysis and reflect calibration update such as powerful control center needed for long lasting usage of fresh rice leaf analysis with NIRS at sight. Especially the agriculture products such as rice will continuously changes that made easily find out the changes and update routinely, if not near future NIRS was worthless due to those changes. Many research related NIRS was shortly study not long term study that made not well using NIRS, so the system needed check simple and instantly using with local language supported signal methods global distance (GD) and neighbour distance (ND) algorithm. Finally the multiple popular field grades instruments should be the same results not only between research grade instruments but also between multiple field grade instruments that needed easily transfer calibration and maintenance between instruments via internet networking techniques.

Improvement of Analytical Method for Total Polysaccharides in Aloe vera Gel (알로에 베라(Aloe vera) 겔 중 총 다당체 시험법 개선)

  • Lee, Young-Joo;Kim, Yun-Je;Leem, Dong-Gil;Yoon, Tae-Hyung;Shin, Ji-Eun;Yoon, Chang-Yong;Kim, Jung-Hoon;Park, Mi-Sun;Kang, Tae-Seok;Jeong, Ja-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.271-276
    • /
    • 2012
  • This study intented to standardize the method for total polysaccharide, which is a functional marker for aloe vera gel in Korea. We used four lyophilized raw materials and commercial aloe gel products, certified as Health Functional Food by Korea Food and Drug Administration, including powder, solution, jelly, tablet and capsule, to optimize the analytical condition of dialysis and phenol-sulfuric acid reaction in polysaccharide analysis. The optimal conditions for polysaccharide analysis included 1 L water for dialysis and change 3 times for 24hr against 25 mL prepared sample solution. Validation test showed lower than 5% of coefficient of variation(CV) in intra-, interday validation in lyophilized raw materials and 4 types of commercial products. In inter-person and inter-laboratory validation with 4 persons from 4 different laboratories, CV(%) were 5.50 and 6.64 respectively. The linearity of polysaccharide analysis was assessed using 5 serial concentration of lyophilized raw materials(0.1, 0.2, 0.3, 0.4, 0.5%(w/v)). The results showed $R^2{\geq}0.995$ of high linearity. In the commercial aloe vera gel products, the results of reproductivity showed lower than 7.08% and revealed that the standardized method from this study ensured high precision for polysaccharide analysis.