• Title/Summary/Keyword: High-Ductility

Search Result 971, Processing Time 0.027 seconds

Evaluation of High-Temperature Tensile Property of Diffusion Bond of Austenitic Alloys for S-CO2 Cycle Heat Exchangers (고온 S-CO2 사이클 열교환기용 스테인리스강 및 Fe-Cr-Ni 합금 확산 접합부의 고온 인장 특성평가)

  • Hong, Sunghoon;Sah, Injin;Jang, Changheui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1421-1426
    • /
    • 2014
  • To improve the inherent safety of the sodium-cooled fast reactor (SFR), the supercritical $CO_2$ ($S-CO_2$) Brayton cycle is being considered as an alternative power conversion system to steam the Rankine cycle. In the $S-CO_2$ system, a PCHE (printed circuit heat exchanger) is being considered. In this type of heat exchangers, diffusion bonding is used for joining the thin plates. In this study, the diffusion bonding characteristics of various austenitic alloys were evaluated. The tensile properties were measured at temperatures starting from the room temperature up to $650^{\circ}C$. For the 316H and 347H types of stainless steel, the tensile ductility was well maintained up to $550^{\circ}C$. However, the Incoloy 800HT showed lower strength and ductility at all temperatures. The microstructure near the bond line was examined to understand the reason for the loss of ductility at high temperatures.

Structural Performance of Concrete-encased Steel Columns using 800MPa Steel and 100MPa Concrete (800MPa 강재 및 100MPa 콘크리트를 적용한 매입형 합성기둥의 구조성능)

  • Kim, Chang-Soo;Park, Hong-Gun;Choi, In-Rak;Chung, Kyung-Soo;Kim, Jin-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.5
    • /
    • pp.497-509
    • /
    • 2010
  • Five concrete-encased steel columns using high-strength steel($f_{ys}$=801MPa) and high-strength concrete($f_{ck}$=97.7MPa) were tested to investigate the eccentric axial load-displacement relationship. Test parameters included the type, yield strength, and spacing of lateral reinforcement, and also the eccentricity of axial load. To analyze the behavior of the column specimens, the nonlinear sectional analysis using strain-compatibility and confinement effect was performed. To examine the applicability of existing design codes for the composite sections using high-strength materials, the test results were also compared with the predictions by the nonlinear analysis and the design codes. The confinement effect of lateral reinforcement increased the ductility of concrete, and the moment capacity of the column specimens increased with the ductility of concrete. The prediction by the nonlinear analysis gave good agreement with the test results. On the other hand, the ACI 318 neglecting lateral confinement effect underestimated the strength of the column specimens, and the Eurocode 4 using complete plastic capacity of steel section overestimated.

Enhancing the Performance of High-Strength Concrete Corbels Using Steel Fibers and Headed Bars (강섬유 및 헤디드 바를 활용한 고강도 콘크리트 내민받침의 성능 향상)

  • Yang, Jun-Mo;Lee, Joo-Ha;Shin, Hyun-Oh;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.697-703
    • /
    • 2009
  • High-strength concrete corbels with varying percentage of steel fibers and two different anchorage types (welding to transverse bar, headed) for the main tension tie were constructed and tested. The results showed that performance in terms of load carrying capacities, stiffness, ductility, and crack width was improved, as the percentage of steel fibers was increased. In addition, the corbel specimens in which headed bars were used as the main tension tie reinforcements showed superior load carrying capacities, stiffness, and ductility compared to the corbel specimens in which the main tension ties were anchored by welding to the transverse bars. From the test results, it is expected that load carrying capacities, durability, and constructibility of high strength concrete corbels would be improved by using steel fibers and headed bars. Experimental results presented in this paper were also compared with various prediction models proposed by researchers and presented in codes. The truss model proposed by Fattuhi provides fairly good predictions for fiber reinforced high-strength concrete corbels.

Effects of B and Cu Additions on the Microstructure and Mechanical Properties of High-Strength Bainitic Steels (베이나이트계 고강도강의 미세조직과 기계적 특성에 미치는 B 및 Cu 첨가의 영향)

  • Yim, H.S.;Lee, S.Y.;Hwang, B.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.28 no.2
    • /
    • pp.75-81
    • /
    • 2015
  • Effects of B and Cu additions on the microstructure and mechanical properties of high-strength bainitic steels were investigated in this study. Six kinds of high-strength bainitic steels with different B and Cu contents were fabricated by thermo-mechanical control process composed of controlled rolling and accelerated cooling. The microstructures of the steels were analyzed using optical and transmission microscopy, and the tensile and impact tests were conducted on them in order to investigate the correlation of microstructure with mechanical properties. Depending on the addition of B and Cu, various low-temperature transformation products such as GB (granular bainite), DUB (degenerated upper bainite), LB (lower bainite), and LM (lath martensite) were formed in the steels. The addition of B and Cu increased the yield and tensile strengths because of improved hardenability and solid solution strengthening, but decreased the ductility and low-temperature toughness. The steels containing both B and Cu had a very high strength above 1.0 GPa, but showed a worse low-temperature toughness of higher DBTT (ductile-to-brittle transition temperature) and lower absorbed energy. On the other hand, the steels having GB and DUB showed a good combination of tensile and impact properties in terms of strength, ductility, yield ratio, absorbed energy, and DBTT.

Experimental compressive behavior of novel composite wall with different width-to-thickness ratios

  • Qin, Ying;Chen, Xin;Zhu, Xing-Yu;Xi, Wang;Chen, Yuan-Ze
    • Steel and Composite Structures
    • /
    • v.36 no.2
    • /
    • pp.187-196
    • /
    • 2020
  • Double skin composite wall system owns several structural merits in terms of high load-carrying capacity, large axial stiffness, and favorable ductility. A recently proposed form of truss connector was used to bond the steel plates to the concrete core to achieve good composite action. The structural behavior of rectangular high walls under compression and T-shaped high walls under eccentric compression has been investigated by the authors. Furthermore, the influences of the truss spacings, the wall width, and the faceplate thickness have been previously studied by the authors on short walls under uniform compression. This paper experimentally investigated the effect of width-to-thickness ratio on the compressive behavior of short walls. Compressive tests were conducted on three short specimens with different width-to-thickness ratios. Based on the test results, it is found that the composite wall shows high compressive resistance and good ductility. The walls fail by local buckling of steel plates and crushing of concrete core. It is also observed that width-to-thickness ratio has great influence on the compressive resistance, initial stiffness, and strain distribution across the section. Finally, the test results are compared with the predictions by modern codes.

Enhancing the Performance of High-Strength Concrete Corbels Using Hybrid Reinforcing Technique (하이브리드 보강기법을 활용한 고강도 콘크리트 내민받침의 성능 향상)

  • Yang, Jun-Mo;Lee, Joo-Ha;Min, Kyung-Hwan;Yoon, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.13-16
    • /
    • 2008
  • Corbels are short cantilevers that project from the faces of a column and are a type of stress disturbed member, resisting both the ultimate shear force applied to them by the beam, and the ultimate horizontal force caused by shrinkage, temperature changes, and creep of the supported elements. Recently, as there have been an increase in the use of high-strength concrete and the concern about corrosion problems, lots of researches about hybrid reinforcing technique, applying strategically high performance reinforcements to the concrete elements, are performed. In this study, fiber reinforced high strength concrete corbels were constructed and tested for applying hybrid reinforcing technique to the corbels using steel fibers and headed bars. The results showed that the performance in terms of load carrying capacities, stiffness, ductility, and crack width was improved, as the steel fibers were added and the percentage of steel fibers was increased. In addition, the corbel specimens used headed bars as main tension ties showed superior load carrying capacities, stiffness, and ductility to the corbel specimens anchored main tension ties by welding to the transverse bars.

  • PDF

An Experimental Study on the Flexural Behavior of Reinforced High-Strength Concrete Beams Using Belite Cement (Belite 시멘트를 사용한 고강도 철근콘크리트 보의 휨 거동에 관한 실험연구)

  • Han, Sang-Hoon;Koo, Bong-Kuen;Kim, Gee-Soo;Cho, Hong-Dong;Juen, Chea-Man
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.221-230
    • /
    • 1999
  • A study was conducted to investigate the flexural behavior of reinforced high-strength concrete beams using Belite cement. In this study, fourteen reinforced Belite and control beams were tested. The major experimental variables are compressive strength(350kgf/$cm^2$ and 600kgf/$cm^2$)of concrete and reinforcement ratios(0.0086~0.0345). They were tested by three point loading method. Comparing with flexural behavior of normal reinforced concrete beams, the investigation were to : (1) determine experimentally the load-displacement relationships and the strain distribution on the section of test beams : (2) determine experimentally the moment-curvature and the load-neutral axis relationship of Belite ; (3) investigate the flexural ductility of Belite ; (4) estimate the ratio of the capacities of nominal moment strength as a function of ACI to as a experiment. From the test results, the flexural behavior of reinforced high-strength concrete beams using Belite cement are similar to flexural behavior of normal reinforced concrete beams.

High Fatigue Life and Tensile Strength Characteristics of Low Activation Ferritic Steel(JLE-1) by TIG Welding (TIG용접한 저방사화 페라이트강(JLF-1)의 고온강도 및 피로수명특성)

  • Yoon, H.K.;Lee, S.P.;Kim, S.W.;Park, W.J.;Kohyama, A.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.181-186
    • /
    • 2001
  • JLF-1 steel (Fe-9Cr-2W-V-Ta), low activation ferritic steel, is one of the promising candidate materials fer fusion reactor applications. High temperature fatigue life and tensile strength of JLF-1 steel and its TIG welded joints were investigated at the room temperature and $400^{\circ}C$. The strength of base metal (JLF-1) is in between those of weld metal and the HAZ. When the test temperature was increased from room temperature to $400^{\circ}C$, both strength and ductility decreased for base metal, weld metal and the HAZ. The longitudinal specimens of base metal showed similar strength and ductility compared with those of the transverse specimens at room temperature and $400^{\circ}C$. Little anisotropy was observed in the JLF-1 steel base metal in terms of rolling direction. Fatigue limit of weld metal which was obtained from cross-weld specimen is 495MPa. Thus, the weld metal showed the higher fatigue limit than those of base metal at both room temperature and $400^{\circ}C$. Little anisotropy of fatigue properties was observed for JLF-1 base metal in terms of rolling direction. When the test temperature was increased from room temperature to $400^{\circ}C$, the fatigue limit of both base metal and weld metal decreased substantially.

  • PDF

Tensile and Charpy Impact Properties of High-Strength Bainitic Steels Fabricated by Controlled Rolling Process (제어압연한 베이나이트계 고강도강의 인장 및 충격 성질)

  • Sung, Hyo Kyung;Shin, Sang Yong;Hwang, Byoungchul;Lee, Chang Gil;Kim, Nack J.;Lee, Sunghak
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.7
    • /
    • pp.615-624
    • /
    • 2010
  • This study is concerned with tensile and Charpy impact properties of high-strength bainitic steels fabricated by controlled rolling process. Six kinds of steels were fabricated by varying finish rolling temperature, start cooling temperature, and cooling rate, and their microstructures and tensile and Charpy impact properties were investigated. Their effective grain sizes were also characterized by the electron backscatter diffraction analysis. The microstructures of the steels rolled in the single phase region were most similar to those of the steels rolled in the two phase region. The steels cooled from $700{^{\circ}C}$ were composed mainly of granular bainites, while those cooled from $600{^{\circ}C}$ contained a number of bainitic ferrites, which resulted in the decrease in ductility and upper shelf energy in spite of the increase in strength. In the steels cooling from $600^{\circ}C$, fine acicular ferrites were well formed when the cooling rate was slow, which led to the best combination of high ductility, high upper shelf energy, and low energy transition temperature according to the decrease in the overall effective grain size due to the presence of acicular ferrites having smaller effective grain size.

Flexural behavior of reinforced recycled aggregates concrete beam after exposed to high temperatures

  • Longshou Qin;Xian Li;Ji Zhou;Ying Liang;Wangsheng Ou;Zongping Chen
    • Structural Engineering and Mechanics
    • /
    • v.87 no.3
    • /
    • pp.201-210
    • /
    • 2023
  • This paper investigates the flexural behavior of reinforced recycled aggregates concrete (RRAC) beams after exposed to high temperatures. The experimental results from 17 specimens were present and compared with temperatures, recycled coarse aggregate (RCA) replacement percentages, and concrete strength as variables. It was found that the high temperature would not cause an observable change in the failure pattern. However, high temperature can significantly reduce the stiffness and ductility, and accelerate the damage degradation of specimens. After exposure to 600℃, the ultimate bearing capacity of the specimens decreased by 20%-30% The mechanical properties of RRAC beams after high temperatures were barely impacted by the replacement percentages. Increasing the concrete strength of RCA could effectively improve the bearing capacity and peak deflection of RRAC beams after exposed to high temperatures. Furthermore, the calculation method of the bending bearing capacity and deflection of RRAC beams was also discussed.