• Title/Summary/Keyword: High-Differential Pressure

Search Result 202, Processing Time 0.029 seconds

Hazards of Explosion and Ignition of Foods Dust (식료품 분진의 발화 및 폭발 위험성)

  • Han, Ou-Sup
    • Korean Chemical Engineering Research
    • /
    • v.55 no.5
    • /
    • pp.629-637
    • /
    • 2017
  • Severe dust explosions occurred frequently in food processing industries and explosion damage increase by flame propagation in pipes or plants. However there are few fire explosion data available due to various powder characteristics. We investigated the characteristics of ignition and explosion on sugar, cornstarch and flour dust with high frequency accidents and high social demand. The measurements showed the median diameter of 27.56, 14.76, $138.5{\mu}m$ and ignition temperature has been investigated using by thermo-gravimetric analysis (TGA) and differential scanning calorimeter (DSC). The maximum explosion pressure ($P_m$) and dust explosion index ($K_{st}$) of sugar, cornstarch and flour are 7.6, 7.6, 6.1 bar and 153, 133, 61 [$m{\cdot}bar/s$], respectively. The flame propagation time in duct was calculated in order to evaluate the damage increase due to flame propagation during dust explosion. The explosion hazard increase due to flame propagation was higher in the order of sugar, flour and cornstarch dust.

A Numerical Study of the 3-D Flow in the Primary Calcinator of Porcelain (도자기 1차 소성로의 3차원 유동장 수치해석에 관한 연구)

  • 김성수;홍성선;박지영;오창섭
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.50-55
    • /
    • 1996
  • A numerical simulation on a primary calcinator of porcelain was performed with using Fluent to calculate the heat efficiency by studying velocity vector and temperature profile according to variables such as the location of outlet and porcelain. Control-Volume based Finite Difference Method and Up-wind scheme are used for discretization of differential equation. SIMPLEC Algorithm and standard k-$\varepsilon$ turbulent model are selected to resolve the pressure-velocity coupling and the turbulent. The result of simulation showed that the whole velocity vector field in a calcinator was varied greatly according to the location of outlet. But the whole temperature profile at each zone was still high regardless of the location of outlet because of the radiation. But the temperature of a case with a outlet at sidepart of preheating or cooling zone was little high compared to the case with a outlet on the top of preheating zone. The velocity vector field and temperature profile in a calcinator were almost not affected by the location of porcelain, but the temperature inside a porcelain was much affected according to the place where it was located. The heat efficiency in a calcinator was 44.6% and the gas temperature in the outlet was about 1000 K.

  • PDF

A Study on the chemical analysis of synthesized Li-AGICs with changes of intercalant contents (Intercalant 함량 변화에 따라 합성된 Li-AGICs의 화학적 분석에 관한 연구)

  • Oh, Won-Chun;Shim, Sang-Kyun
    • Analytical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.209-215
    • /
    • 1997
  • Li-AGICs as a anode of secondary battery were synthesized by high-pressure method as a function of the Li-contents. The characteristics of these prepared compounds were determined from the studies with X-ray diffraction method, UV/VIS spectrophotometric and differential scanning calorimeter(DSC) analysis. From the results of X-ray diffraction, it was found that the lower stage intercalation compounds were formed with increase of Li-contents. The mixed stages in these compounds were also observed. In the case of the $Li_{30wt%}$-AGIC, the compounds in the stage 1 structure were formed predominantly, but the structure of only pure stage 1 for structural defect of artificial graphite is not observed. According to UV/VIS spectrophotometric analysis, $Li_{30wt%}$-AGIC shows distinguishable energy state spectrum with the position of $R(%)_{min}$ values, but the characteristic spectra of almost all Li-AGICs are not observed. The enthalpy and entropy changes of the compounds can be obtained from the differential scanning calorimetric analysis results. From the results, it was found that exothermic and endothermic reactions of Li-AGICs are related to thermal stability of lithium between artificial graphite layers.

  • PDF

Differential Expression of a Chimeric nos-npt II Gene in 9 Years Old Hybrid Poplars (Populus koreana x P. nigra)

  • Noh, Eun Woon;Lee, Jae Soon;Choi, Young Im;Lee, Hyo Shin;Bae, Eun Kyung;Lee, Ji Hee
    • Journal of Plant Biotechnology
    • /
    • v.6 no.1
    • /
    • pp.15-19
    • /
    • 2004
  • The expression of a chimeric transgene (nos-npt II) has been examined in 9 years old transgenic poplars (Populus koreana x P. nigra) growing in a nursery. The expression of the gene in twenty six independentely transformed plants were examined by 1) enzyme (NPT II) assay, 2) RT-PCR, and 3) resistance to kanamycin. High NPT II activities in young leaves of all the transformed plants were found even without a selection pressure for antibiotics for 9 years. However, the activity varied with the positions of leaves in the stem in that young leaves showed higher activity than did mature tissues. When leaf segments were cultured in the presence of 150 mg/l kanamycin, only those from young leaves produced vigorously growing callus. However, as in the case of NPTII assay, the leaf segments from mature leaves did not form callus well on the media. RT-PCR with nptII specific primers also showed that amplification products were observed only when RNAs from young tissues were used. The total RNA gel showed that while RNA in young leaves are relatively stable and in a large quantity, those in old leaves were mostly degraded. All the above results suggest that the gene is transcriptionally active only in young tissue even though it is attached to a constituitive promoter. Therefore, the expression of foreign gene in poplar plants seemed to be affected by the metabolic state of the cells and thus vary greatly with the developmental stages and the age of tissue.

Implementation of RF Monitoring System for the Dust Collector in Industrial Environments (산업 환경에서의 집진기에 대한 RF모니터링 시스템 구현)

  • Lee, Sung-Yeob;Lee, Kwang-Hee;Ko, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.5
    • /
    • pp.513-517
    • /
    • 2014
  • In this study, we implemented and designed an RF monitoring system to manage a dust collector wirelessly, which is manually operated. The dust collector prevents the emission of air pollutants and improves air condition. It is possible to implement a high-value monitoring system of a dust collector, the system will wirelessly monitor many important data such as the operating time, the amount of electricity consumption, and the differential pressure value of a large number of the dust collectors in an industrial site, the system also displays and saves these data on a manager's PC, and when an error occurs, the system sends the error message to a manager's mobile phone. Therefore, through the RF monitoring system implemented in this paper, it is possible to reduce unnecessary loss for recording information of each dust collector to stack emission management system (SEMS).

Experiment Study on Field Applicability of Siphon as a Intake Facility of Agricultural Reservoir for Disaster Prevention (재해대비 농업용저수지 취수시설로서 사이폰의 현장적용성에 관한 실험적 연구)

  • Yang, Young Jin;Lee, Tae Ho;Oh, Sue Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.103-110
    • /
    • 2018
  • Most of the intake facilities of small agricultural reservoirs are conduits and they are regarded as serious defects due to the structural weakness that penetrates the body of the dam, and countermeasures are needed. This study suggests the application method of siphon type water intake facility by hydraulic model test and physical scale model test of siphon type water intake facility which has high safety and easy maintenance. Experimental results show that sufficient flow rate can be secured for the purpose of intaking water according to the differential head between the reservoir and the discharge part, and the flow rate can be controlled by the valve. The negative pressure was -31.5 kPa, and vibration and noise did not occur during the operation of the siphon. The maximum flow velocity in the discharge outlet was 1.11 m/s which meets the criterion for irrigation canals. Therefore, scour risk would be very low. As a result of the inflow distribution experiment, even if the inflow part is separated by only about 0.8 m, the flow velocity is remarkably decreased, so that the clogging by debris would not appear. When the pump was operated only once for the first time and the inside of the siphon was filled with water, continuous operation was possible by only valve operation. The results of this study are expected to be used for the design guidelines of the water intake facilities and improve safety and maintenance convenience of agricultural reservoirs.

Effect of Oxygen on the Magnetic and Recording Characteristics of Magneto-Optical Disk (광자기 디스크의 기록 및 자기적 특성에 산소가 미치는 영향)

  • Choe, G.
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.3
    • /
    • pp.229-233
    • /
    • 1993
  • The effects of differential partial pressures of oxygen during sputtering on the magnetic and recording characteristics of magneto-optical disks were investigated. Different flows of oxygen were deliberately introduced into the sputtering chamber to have a variety of partial pressures of oxygen during sputtering. A residual gas analyzer was employed to monitor the oxygen peak before, during, and after sputtering and to estimate the reacted oxygen amount. Most of the oxygen introduced into the chamaber was reacted during sputtering. As the partial pressure of oxygen increased, the oxygen content of the TbFeCoCr film increased also. The oxygen appeared to be bound as Tb-O, effectively decreasing the magnetically active Tb content of the film The coercivity decreased but the squareness of the Kerr hysteresis loops was still excellent. The perpendicular anisotropy was not significantly affected by oxygen amount. The carrier-to-noise ratio, includi!1g the write power sensitivity and bias field sensitivity did not change too much with oxygen content in the film The disks sputtered with oxygen showed better bias field sensitivity with lower write power threshold than the disk sputtered without oxygen, due to high demagnetization during domain formation. No significant degradation of coercivity for the disk sputtered oxygen was observed during an accelerated aging test.

  • PDF

Characteristics of Air Egress Velocity in Vestibule Pressurization System Using the Fire Dynamics Simulator (FDS를 이용한 특별피난계단 부속실 제연설비의 방연풍속 기류특성)

  • Ryu, Sung-Ho;Lee, Su-Kyung;Hong, Dae-Hwa;Choi, Keum-Ran
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.153-159
    • /
    • 2010
  • In this study, we confirmed the fact that air egress velocity of pressure differential system installed at vestibule of smokeproof stairway in domestic high-rise building becomes back-flow to stair-lobby at upper vestibule. Rather it do not back-flow to the livingroom. when fire occur and the door opens to escape from fire zone. so we carry out actual and computational fluid dynamics measurement. In the case upward 45 gradient of supply damper's blade, The simulation results that air flow of upper vestible is steady but back-flow phenomenon occurred at the bottom. However, in the case of $4m^2$, direction of the flow was ideal to living room. If a vestibule’s area is smaller, it must be designed and built according to performance-based design.

Studies on the Improvement of Butt Welding Characteristic of Polyethylene Pipes (PE 이중벽관의 맞대기 융착 용접 강도 향상에 관한 연구)

  • An, Ju-Seon;Lee, Kyng-Won;Kim, Jae-Sung;Lee, Bo-Young
    • Journal of Welding and Joining
    • /
    • v.29 no.1
    • /
    • pp.85-89
    • /
    • 2011
  • Waste water is disposed to sewage disposal plant by underground PE double wall pipes. Various processes have been introduced to join PE pipes, but most of these methods have many disadvantages such as costs, lack of reliability and difficulties in joining, etc. Recently butt welding has been paid much attention to joint PE pipes as this process has many advantages such as cost, safety and reliability. In this study, newly developed heat plate, a patent-pending heat plate with a groove, was used to butt-weld PE double wall pipes with different misalignment gaps to simulate real underground conditions, and the butt welding temperature of PE pipe was determined by thermal analysis (Thermal Gravimetric Analysis, Differential Scanning Calorimetry and Dynamic Mechanical Analysis). The resulting joining characteristics of double wall pipes were compared with those from a conventional heat plate, in terms of stiffness, flattening and leakage tests. The results from the stiffness and flattening test showed that there were no big differences between the butt-welded joints made from these two plates. From the leakage test, although PE pipes welded with a conventional heat plate did leak below the required test conditions (10 min. at 0.75kgf/cm2), the pipes welded with a patent-pending grooved heat plate did not show any leakage even at a pressure 1.5 times higher than the required conditions. It was noted that by utilizing a grooved heat plate more complete fusion at the pipe joints could be obtained, which in turn induced a high quality joints.

Reliability of COF Flip-chip Package using NCP (NCP 적용 COF 플립칩 패키지의 신뢰성)

  • Min, Kyung-Eun;Lee, Jun-Sik;Jeon, Je-Seog;Kim, Mok-Soon;Kim, Jun-Ki
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.74-74
    • /
    • 2010
  • 모바일 정보통신기기를 중심으로 전자패키지의 초소형화, 고집적화를 위해 플립칩 공법의 적용이 증가되고 있는 추세이다. 플립칩 패키징 접합소재로는 솔더, ICA(Isotropic Conductive Adhesive), ACA(Anisotropic Conductive Adhesive), NCA(Non Conductive Adhesive) 등과 같은 다양한 접합소재가 사용되고 있다. 최근에는 언더필을 사용하는 플립칩 공법보다 미세피치 대응성을 위해 NCP를 이용한 플립칩 공법에 대한 요구가 증가되고 있는데, NCP의 상용화를 위해서는 공정성과 함께 신뢰성 확보가 필요하다. 본 연구에서는 LDI(LCD drive IC) 모듈을 위한 COF(Chip-on-Film) 플립칩 패키징용 NCP 포뮬레이션을 개발하고 이를 적용한 COF 패키지의 신뢰성을 조사하였다. 테스트베드는 면적 $1.2{\times}0.9mm$, 두께 $470{\mu}m$, 접속피치 $25{\mu}m$의 Au범프가 형성된 플리칩 실리콘다이와 접속패드가 Sn으로 finish된 폴리이미드 재질의 flexible 기판을 사용하였다. NCP는 에폭시 레진과 산무수물계 경화제, 이미다졸계 촉매제를 사용하여 다양하게 포뮬레이션을 하였다. DSC(Differential Scanning Calorimeter), TGA(Thermogravimetric Analysis), DEA(Dielectric Analysis) 등의 열분석장비를 이용하여 NCP의 물성과 경화거동을 확인하였으며, 본딩 후에는 보이드를 평가하고 Peel 강도를 측정하였다. 최적의 공정으로 제작된 COF 패키지에 대한 HTS (High Temperature Stress), TC (Thermal Cycling), PCT (Pressure Cooker Test)등의 신뢰성 시험을 수행한 결과 양산 적용 가능 수준의 신뢰성을 갖는 것을 확인할 수 있었다.

  • PDF