• 제목/요약/키워드: High-Differential Pressure

검색결과 202건 처리시간 0.028초

Development and performance evaluation of a cryogenic blower for HTS magnets

  • Kwon, Yonghyun;Mun, Jeongmin;Lee, Jaehwan;Seo, Geonghang;Kim, Dongmin;Lee, Changhyeong;Sim, Kideok;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권4호
    • /
    • pp.57-61
    • /
    • 2020
  • Cooling by gas helium circulation can be used for various HTS (high temperature superconductor) magnets operating at 20~40 K, and a cryogenic blower is an essential device for circulating gas helium in the cooling system. The performance of the cryogenic blower is determined by various design parameters such as the impeller diameter, the blade number, the vane angle, the volute cross-sectional area, and the rotating speed. The trailing edge angle and the height of impeller vane are also key design factors in determining the blower performance. This study describes the design, fabrication and performance evaluation of cryogenic blower to produce a flow rate of 30 g/s at 5 bar, 35 K gas helium. The impeller shape is designed using a specific speed/specific diameter diagram and CFD analysis. After the fabrication of the cryogenic blower, a test equipment is also developed using a GM cryocooler. The measured flow rates and the pressure differences are compared with the design values at various rotating speeds and the results show a good agreement. Isentropic efficiency is also evaluated using the measured pressures and temperatures.

Exercise-induced rhabdomyolysis with acute kidney injury complicated by posterior reversible encephalopathy syndrome: a case report

  • Kim, Su Min;Lee, Yoo Jin;Heo, Chang Min;Park, Si Hyung;Park, Kang Min;Ko, Jung Hae;Park, Bong Soo;Kim, Yang Wook
    • Annals of Clinical Neurophysiology
    • /
    • 제24권2호
    • /
    • pp.93-97
    • /
    • 2022
  • Posterior reversible encephalopathy syndrome (PRES) is a rare condition manifested by inflammation in certain areas of the brain. Rhabdomyolysis with acute kidney injury (AKI) complicated by PRES is rarely reported. A 26-year-old female presented with neurological symptoms, high blood pressure, and AKI. Her symptoms improved with blood pressure control, anticonvulsant drug medications, and renal replacement therapy. This case demonstrates that PRES should be considered in the differential diagnosis of patients who have rhabdomyolysis with AKI accompanied by neurological symptoms, including headaches and convulsions.

Experimental characterization of the lateral and near-wake flow for the BARC configuration

  • Pasqualetto, Elena;Lunghi, Gianmarco;Rocchio, Benedetto;Mariotti, Alessandro;Salvetti, Maria Vittoria
    • Wind and Structures
    • /
    • 제34권1호
    • /
    • pp.101-113
    • /
    • 2022
  • We experimentally investigate the high-Reynolds flow around a rectangular cylinder of aspect ratio 5:1. This configuration is the object of the international BARC benchmark. Wind tunnel tests have been carried out for the flow at zero angle of attack and a Reynolds number, based on the crossflow cylinder length and on the freestream velocity, equal, to 40 000. Velocity measurements are obtained by using hot-wire anemometry along 50 different cross-flow traverses on the cylinder side and in the near wake. Differential pressure measurements are acquired on multiple streamwise sections of the model. The obtained measurements are in a good agreement with the state-of-the-art experiments. For the first time among the several contributions to the BARC benchmark, detailed flow measurements are acquired in the region near the cylinder side and in the near-wake flow. The edges and the thickness of the shear layers detaching from the upstream edges are derived from velocity measurements. Furthermore, we compute the flow frequencies characterizing the roll-up of the shear layers, the evolution of vortical structures near the cylinder side and the vortex shedding in the wake.

고압처리 공정변수가 조피볼락의 초기 품질특성에 미치는 영향 (Process Parameters on Quality Characteristics of Jacopever (Sebastes schlegeli Hilgendorf) under Treatment of Hydrostatic Pressure)

  • 김민지;이수정;김종태
    • 한국식품영양학회지
    • /
    • 제29권3호
    • /
    • pp.371-381
    • /
    • 2016
  • The present study investigated the effects of processing parameters such as time (10, 20, 30, 40 min), pressure (25, 50, 75, 100 MPa), and the salinity of brine (0~10%(w/v)) on jacopever (Sebastes schlegeli Hilgendorf) in order to establish optimization of the three factors using a high hydrostatic pressure (HHP) machine. To do so, it analyzed the quality characteristics of volatile basic nitrogen (VBN), trimethylamine (TMA), total bacterial counts, dynamic viscoelasticities, and differential scanning calorimetry (DSC) properties. First, when the time increased to 40 mins, by 10 min intervals, the total bacterial counts in HHP groups under $25^{\circ}C$, 100 MPa, and 4%(w/v) brine were significantly decreased except for the first 10 min in comparison to the control group. In regards to DSC properties, the onset temperature ($T_O$) of the first endothermal curve was significantly reduced. Second, when the pressure level increased up to 100 MPa by 25 MPa increments, the total bacterial counts in the HHP samples significantly decreased for 20 min at 50 MPa or higher. As the pressure increased, G', G" and the slope of tan ${\delta}$ decreased (except for 50 MPa). Third, in regards to the salinities of brine, when the HHP processing was treated at 100 MPa, $25^{\circ}C$ for 20 min, the total bacterial counts of all the HHP groups significantly decreased in comparison to those of the control group. A significant difference was found in the enthalpy of the second endothermic curve in the 6~10%(w/v) (except 7%(w/v)) HHP groups. Therefore, the salinity of the immersion water under the HHP condition was appropriate when it was lower than 6%(w/v). The present study demonstrated that the optimum parameter condition according to/under the condition of the microbial inhibition and economic effects using an HHP would be the reaction time for 20 min, reaction pressure at 100 MPa, and the salinity of 4%(w/v) brine.

Micromachined ZnO Piezoelectric Pressure Sensor and Pyroelectric Infrared Detector in GaAs

  • Park, Jun-Rim;Park, Pyung
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권2호
    • /
    • pp.239-244
    • /
    • 1998
  • Piezoelectric pressure sensors and pyroelectric infrared detectors based on ZnO thin film have been integrated with GaAs metal-semiconductor field effect transistor (MESFET) amplifiers. Surface micromachining techniques have been applied in a GaAs MESFET process to form both microsensors and electronic circuits. The on-chip integration of microsensors such as pressure sensors and infrared detectors with GaAs integrated circuits is attractive because of the higher operating temperature up to 200 oC for GaAs devices compared to 125 oC for silicon devices and radiation hardness for infrared imaging applications. The microsensors incorporate a 1${\mu}$m-thick sputtered ZnO capacitor supported by a 2${\mu}$m-thick aluminum membrane formed on a semi-insulating GaAs substrate. The piezoelectric pressure sensor of an area 80${\times}$80 ${\mu}$m2 designed for use as a miniature microphone exhibits 2.99${\mu}$V/${\mu}$ bar sensitivity at 400Hz. The voltage responsivity and the detectivity of a single infrared detector of an area 80${\times}$80 $\mu\textrm{m}$2 is 700 V/W and 6${\times}$108cm$.$ Hz/W at 10Hz respectively, and the time constant of the sensor with the amplifying circuit is 53 ms. Circuits using 4${\mu}$m-gate GaAs MESFETs are fabricated in planar, direct ion-implanted process. The measured transconductance of a 4${\mu}$m-gate GaAs MESFET is 25.6 mS/mm and 12.4 mS/mm at 27 oC and 200oC, respectively. A differential amplifier whose voltage gain in 33.7 dB using 4${\mu}$m gate GaAs MESFETs is fabricated for high selectivity to the physical variable being sensed.

  • PDF

제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구 (Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control)

  • 이재빈;문주현;이성혁;유홍선
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.103-109
    • /
    • 2011
  • 본 연구에서는 초고층 건축물 화재 시 피난 안전 구역이 있는 피난 층에서 화재실로부터 발생하는 연기의 거동을 파악하기 위하여 상용코드를 사용하여 수치해석을 하였다. 화재를 모사하기 위하여 10 MW의 발열량에 해당하는 온도와 속도를 이용하여 부력 plume을 적용하였으며 종 보존 방정식을 이용하여 화재 연기 거동을 예측하였다. 피난 안전 구역에 제연 댐퍼를 설치하여 급기 가압 제연 시스템을 적용하였으며 화재실 문이 열린 경우 25 $m^3/s$, 화재실과 부속실 문이 동시에 열린 경우 50 $m^3/s$의 제연 댐퍼송풍량은 화재 안전 기준 NFSC 501-A를 만족하며 충분히 제연이 가능하다는 것을 확인하였다. 부속실문이 열린 경우, 화재실의 문이 닫혀 있더라도 문과 벽 사이의 틈새 면적으로 연기가 피난 안전 구역으로 유입될 가능성이 있다. 또한, 50 $m^3/s$ 높은 송풍량으로 제연 중 화재실 문이 닫힐 경우 피난자가 화재실에 고립될 가능성을 확인하였다. 그러므로 피난자의 안전을 위해 제연 송풍량의 조절이 필요하며 본 연구에서는 피난 시나리오에 따른 적절한 송풍량을 제안한다.

미녹시딜과 다이아미노피리미딘옥사이드 성분을 함유하는 니오좀 제형의 물성 및 피부투과 (Physical Properties and Skin Penetration of Niosome Formulations Containing Minoxidil and Diaminopyrimidine Oxide)

  • 김보경;김원형;윤경섭
    • 대한화장품학회지
    • /
    • 제49권2호
    • /
    • pp.127-139
    • /
    • 2023
  • 본 연구에서는 의약품 원료로 잘 알려진 minoxidil과 화장품 원료인 diaminopyrimidine oxide (DAO) 활성성분으로 사용하여 니오좀(niosome)의 물성평가와 더불어 인공피부에 대한 경피투과율을 비교하였다. 나노입자의 니오좀을 제조하기 위해 고압유화(high pressure homogenization) 방법을 이용하였으며 제타사이저(zetasizer)로 물성평가를 진행하였다. 활성성분을 포함한 니오좀의 입자크기는 HLB에 따라 평균 99 ~ 123 nm, 제타전위(zeta potential)는 -60 ~ -81 mV의 범위로 측정되었다. DSC (differential scanning colorimetry)를 통해 결정성 성분인 minoxidil이 니오좀 내에 무결정 상태로 균일하게 용해되어 있음을 확인하였다. 경피투과량을 확인 및 비교하기 위해 in vitro Franz diffusion cell 방법으로 측정하였으며, 니오좀 제형이 대조군인겔 제형보다 minoxidil의 경우 3.4배, DAO의 경우 11.1배 높은 투과율을 보였다. 또한 minoxidil과 DAO 니오좀의 경피투과 비교 시 유사한 경향을 보였으며, 상대적으로 DAO의 투과량이 많았다. HLB 값을 달리한 니오좀 제형을 Cryo-TEM을 이용하여 형상을 관찰하였으며, 모두 소포체가 형성되었으며 SUV (small unilamella vesicle)와 LUV (large unilamella vesicle)의 중간 형태임을 확인하였다. 본 연구를 통하여 탈모에 효과적인 약물인 minoxidil과 화장품 원료인 DAO 성분을 니오좀 제형에 캡슐화시킴으로써 효과적으로 피부에의 전달을 기대할 수 있다.

Thermophysical Properties of $UO_2$ Fuel Materials

  • Lee, Hung-Joo;Kim, Chul-Whan
    • Nuclear Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.81-88
    • /
    • 1976
  • Flash Method로서 열에 관련된 물리적인 성질(밀도, 정압비열 또는 열확산 계수등)을 측정할 수 있는데 이 방법을 이용하여 핵연료의 열화산 계수를 상온(300k)으로부터 고온(1400 K)까지 측정하였으며 정압비열은 시차열용량법 (Differential Scanning Calorimeter)에 의하여 상온에서부터 500k까지 측정하였고 열전도 계수는 열확산 계수, 정압비열 그리고 핵연료의 밀도로부터 계산하였다. 본 연구의 결과는 낮은 온도(500k 이하)에서는 불순물의 정도(Impurity Level)에 따라서 열전도 계수가 크게 달라지기 때문에 중요시되지만 높은 온도(1000k 이상)에서는 불순물의 정도에 따른 열전도 계수의 변화가 근소함으로 그의 존재유무가 비교적 중요시되지 않는 Dielectric Material의 보편적인 경향과 완전히 일치하였다. Gd$_2$O$_3$를 첨가한 다수의 $UO_2$ Sample들에 대한 열확산 계수를 상온에서 측정하여 비교함으로써 이것을 재확인하였다.

  • PDF

분리형 펄스 레이져 증착법을 이용한 ZnO 박막의 특성에 관한 연구 (Preparation of High Quality ZnO Thin Films by Separated Pulsed Laser Deposition)

  • 박상무;이붕주
    • 한국전기전자재료학회논문지
    • /
    • 제21권9호
    • /
    • pp.818-824
    • /
    • 2008
  • The Separated Pulsed Laser Deposition (SPLD) technique uses two chambers that are separated by a conic metallic wall with a central orifice. The pressures of ablation chamber and deposition chamber were controlled by the differential vacuum system. We deposited zinc oxide (ZnO) thin films by SPLD method to obtain high quality thin films. When the bias voltage of +500 V was applied between a substrate and an orifice, the ZnO thin film was deposited efficiently. The deposited ZnO thin film at ablation chamber gas pressure of Ar 5 mTorr showed the sharpest ultraviolet absorption edge indicatory the band gap of about 3.1 eV. ZnO thin films were deposited using effect of electric and magnetic fields in the SPLD method. E${\times}$B drift happened by an electric fields and a magnetic fields, activated plasma plume, as a result the film surface became very smooth. When the bias voltage of +500 V and magnet of 0,1 T were applied the ZnO thin films surface state showed high quality. Grain size was 41.99 nm and RMS was 0.84 nm.

고무복합체의 모세관 압출에서 비선형 점탄성 모델의 적용 (Application to Non-linear Viscoelastic Model on Capillary Extrusion of Rubber Compounds)

  • 최성현;류민영;김학주;박동명;전재후
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.209-212
    • /
    • 2007
  • Rubber compounds have high viscoelastic property. One of the viscoelastic behaviors during profile extrusion is the swelling of extrudate. In this study, die swell of rubber compounds at the capillary die have been investigated through an experiment and computer simulation. They have been performed using fluidity tester in experiment and commercial CFD code, Polyflow in computer simulation. Die swell of rubber compounds for relaxation time at several modes under same conditions with the experiment were predicted using non-linear differential viscoelastic model, Phan-Thien-Tanner (PTT) model. The simulation was analyzed compared with the experiment. Viscoelastic behaviors for pressure, velocity and shear rate distribution were analyzed at the capillary die. It is concluded that the PTT model successfully represented the amount of the optimal die swell of rubber compounds for relaxation time at different modes.

  • PDF