Determination of Energy Distribution of Interface State Density in the MNOS Memory Device (MNOS 기억소자의 계면상태밀도의 에너지 분포의 결정)

  • 한태현;강창수;박종하;서광열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.10a
    • /
    • pp.1-4
    • /
    • 1988
  • The high frequency and quasi-state C-V curves were measured to determine the interface state density in MNOS devices. Berglund method was appropriate for determination of energy distribution of interface state density all over the energy gap. Applying Vg vs Øs relation by Berlund method to comparison-analysis method of the high-frequency and quasi-static C-V curves, we were able to determine the energy distribution by only measured C-V curves without theoretical C-V curves. The interface state density near the conduction band was high at lower temperature than room temperature.

  • PDF

A Study on Air-distribution method for the Thermal Environmental Control in the Data Center (데이터센터의 합리적인 환경제어를 위한 공기분배 시스템에 대한 연구)

  • Cho, Jin-Kyun;Cha, Ji-Hyoung;Hong, Min-Ho;Yeon, Chang-Kun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.487-492
    • /
    • 2008
  • The cooling of data centers has emerged as a significant challenge as the density of IT server increases. Server installations, along with the shrinking physical size of servers and storage systems, has resulted in high power density and high heat density. The introduction of high density enclosures into a data center creates the potential for "hot spots" within the room that the cooling system may not be able to address, since traditional designs assume relatively uniform cooling patterns within a data center. The cooling system for data center consists of a CRAC or CRAH unit and the associated air distribution system. It is the configuration of the distribution system that primarily distinguishes the different types of data center cooling systems, this is the main subject of this paper.

  • PDF

Structural and Electrical Properties of ZrO2 Films Coated onto PET for High-Energy-Density Capacitors

  • Park, Sangshik
    • Applied Science and Convergence Technology
    • /
    • v.23 no.2
    • /
    • pp.90-96
    • /
    • 2014
  • Flexible $ZrO_2$ films as dielectric materials for high-energy-density capacitors were deposited on polyethylene terephthalate (PET) substrates by RF magnetron sputtering. The growth behavior, microstructure and electrical properties of the flexible $ZrO_2$ films were dependent on the sputtering pressure and gas ratio. Although $ZrO_2$ films were deposited at room temperature, all films showed a tetragonal crystalline structure regardless of the sputtering variables. The surface of the film became a surface with large white particles upon an increase in the $O_2/Ar$ gas ratio. The RMS roughness and crystallite size of the $ZrO_2$ films increased with an increase in the sputtering pressure. The electrical properties of the $ZrO_2$ films were affected by the microstructure and roughness. The $ZrO_2$ films exhibited a dielectric constant of 21~38 at 1 kHz and a leakage current density of $10^{-6}{\sim}10^{-5}A/cm^2$ at 300 kV/cm.

Effect of Organic Additive Composition on Isostatic Thermocompression Behavior of Alumina Tapes (유기물 조성에 따른 알루미나 테이프의 열간 가압 거동)

  • 이명현;박일석;김대준;이득용
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.8
    • /
    • pp.824-831
    • /
    • 2000
  • Alumina tapes, having various ratios of alumina to alumina+binder+plasticizer (a/(a+o)) and binder to binder+plasticizer(b/(b+p)), were prepared by the tape casting method. The tapes were thermocompressed varying the thermocompression parameters such as temperature, pressure, and duration time. Among the parameters, the pressure was the most influential to the tape packing density. The packing density varied in two different ways depending on the a/(a+o) ratio. For the tapes having low a/(a+o) ratio, a saturation density was reached by applying very a low pressure of 1 MPa. For tapes with high a/(a+o), on the contrary, the saturation density was obtained at a relatively high pressure. These different responses to the pressure are attributed to the fact that the rearrangement of alumina particles by the pressure becomes easy as an organic content in the tapes is high.

  • PDF

Influence of Mold Temperature, Lubricant and its Additional Quantity on Compressibility in Warm Compaction

  • Ushirozako, Tsutomu;Yamamoto, Masayuki
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.195-196
    • /
    • 2006
  • In recent years, demands for sintered ferrous material with higher strength are increasing. To satisfy these demands, studies and commercial use of the die wall lubrication method, the warm compaction method and the combination of both methods are widely carried out to achieve high density. The die wall lubrication warm compaction method makes it possible to achieve high density by reducing internal lubricant through die wall lubrication, although the method involves several issues such as prolonged cycle time due to lubricant spraying and difficulty in spraying lubricant in the case of compacting with complicated geometry. Meanwhile, the conventional warm compaction method requiring no die wall lubricant application cannot achieve such a high density as in the case of die wall lubrication warm compaction due to higher volume of internal lubricant. However, this report discloses our study result in which the possibility of improving density is exhibited by using a lubricant type with superior dynamic ejection property that can reduce volume of lubricant additive.

  • PDF

Gigacycle Fatigue Endurance Strength of High Density Mo and Cr-Mo Prealloyed Sintered Steel

  • Xu, Chen;Danninger, Herbert;Khatibi, Golta;Weiss, Brigitte
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.385-386
    • /
    • 2006
  • For attaining optimum fatigue resistance of PM steels, high density levels are necessary. In this work, sintered steels Fe-1.5%Mo-0.6%C and Fe-1.5%Cr-0.2%Mo-0.6%C were produced with density levels of 7.1 to $7.6\;g.cm^{-3}$. Ultrasonic fatigue testing with 20 kHz was performed in push-pull mode up to 10E9 cycles. It was shown that the fatigue endurance strength is strongly improved by higher density levels, but also higher sintering temperatures are beneficial. The Cr-Mo steels proved to be superior to the plain Mo alloyed, due to a more favourable as-sintered matrix microstructure.

  • PDF

MICROSTRUCTURE AND NOISE CHARACTERISTICS IN Co-Cr BASED ALLOY THIN FILM MAGNETIC RECORDING MEDIA

  • Koshimoto, Y.;Hirono, S.;Ohkubo, T.;Umemura, S.;Maeda, Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.690-694
    • /
    • 1995
  • Reducing media noise is a key to realizing high areal recording density. However, perpendicularly oriented Co-Cr films, stong candidates for high density recording media, have received little attention in terms of recording noise. We studied the noise characteristics of Co-Cr based alloy films by varying the compositionally separated structure. Co-Cr films with fine compositionally separated microstructure were observed to have low noise, which recording density dependence were negative or week. Studies on control of the microstructure and magnetic properties in combination with noise analysis are important to realize high density recording media.

  • PDF

Stomatal Control and Strategy Segregation to Drought Stress in Young Trees of Several Oak Species (수종 참나무속 유식물의 건조스트레스에 대한 기공저항의 조절과 전략의 분화)

  • 김종욱;김준호
    • The Korean Journal of Ecology
    • /
    • v.17 no.3
    • /
    • pp.241-249
    • /
    • 1994
  • Leaf diffusive resistance (LDR), stomatal density, length of guard cell and hair density of leaves of 6 oak species were determined under withdrawal of water, and their strategies of drought stress were analyzed by principal component analysis. LDR of Quercus acutissima, Q. aliena and Q. serrata increased earlier than those of the other species at high leaf water potential $({\Psi}_{leaf})$ or low water saturation deficit (WSD), which was an avoidance mechanism reducing damage by water stress. Q. variabilis with low stomatal density, small stomatal size and high hair density had avoidance mechanisms increasing LDR at high $({\Psi}_{leaf})$ However, Q. mongolica and Q. dentata increased LDR at low $({\Psi}_{leaf})$ as xeric species do. Results from principal component analysis on the 15 variables related to strategies of drought stress indicated that the 6 oak species were divided into 2 groups: (1) Q. acutissima, Q. aliena and Q. serrata as mesic habitat species and (2) Q. variabilis, Q. mongolica and Q. dentata as xeric habitat species. Among three xeric species Q. acutissima differed from the other two species in the drought strategies such as high hair density, low stornatal density, high leaf area ratio, stomatal closing at low $({\Psi}_{leaf})$ and small cell wall elasticity. The results could reasonably explain their drought strategies in natural habitat.

  • PDF

FRACTAL ANALYSIS OF TIDAL CHANNEL USING HIGH RESOLUTION SATELLITE IMAGES

  • Eom, Jin-Ah;Lee, Yoon-Kyung;Ryu, Joo-Hyung;Won, Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.29-32
    • /
    • 2007
  • Tidal channel development is influenced by sediment type, grain size, composition and tidal current. Tidal channels are usually characterized by channel development, density and shape. Quantitative analysis of tidal channels using remotely sensed data have rarely been studied. The objective of this study is to quantify tidal channels in terms of fractal dimension and compare different inter-tidal channel patterns. For the fractal analysis, we used Box counting method which had been successfully applied to streams, coastlines and others linear features. For a study, the southern part of Ganghwado tidal flats was selected where is famous for high dynamics of tidal currents and vast tidal flats. This area has different widths and lengths of tidal channels. IKONOS and Komsat-2 MSC images were used for extracting tidal channels, and the Box counting method was applied to obtain fractal dimensions (D) for each tidal channel. Yeochari area possesses channels with linear pattern and less dense development and accordingly show low D values ranging from 1.037 to 1.038. On other hands, area (near Donggumdo and Yeongjongdo ) of dendrites channel pattern and dense development resulted in high D values from 1.2057 to 1.2667. Also, area possesses channels with linear pattern had low density about $18{\sim}24%$. Area of dendritic channel pattern had high density about $34{\sim}69%$. The difference of fractal dimensions about 0.2 according to channel development in tidal flats is relatively large enough to use as an index for tidal channel classification. Also, area where channels showed linear pattern had low density about $18{\sim}24%$. Area of dendritic channel pattern had high density about $34{\sim}69%$. Using fractal dimension and density, it would be possible to quantify the tidal channel development in association with surface characteristics.

  • PDF

Imperfect Correlation of Mammographic and Clinical Breast Tissue Density

  • Alipour, Sadaf;Bayani, Leila;Saberi, Azin;Alikhassi, Afsaneh;Hosseini, Ladan;Eslami, Bita
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3685-3688
    • /
    • 2013
  • Background: Clinicians determine degree of mammographic density based on tissue firmness on breast examination. The study aimed to compare breast density in mammography and clinical breast examination. Materials and Methods: Six-hundred sixty three women 40 years of age or older were studied. The breast exam density was graded from 1 to 4 by two expert surgeons and the mammographic parenchymal density by two expert radiologists. Then for practical reasons, grades 1 and 2 were considered as low-density and grades 3 and 4 as high-density. Results: High and low densities were detected in 84.5% and 15.5% of clinical breast examinations and 59.7% and 40.3% of mammographies, respectively. The statistical analysis showed a significant difference between the breast tissue densities in breast examination with those in mammography. Conclusions: A clinically dense breast does not necessarily imply a dense mammographic picture.