• Title/Summary/Keyword: High-Concentration Electrolyte

Search Result 194, Processing Time 0.026 seconds

Peritoneal Dialysis in Dogs: 20 cases (2006-2008) (개에서 복막투석 적용: 20 증례 (2006-2008))

  • Nam, So-Jeong;Choi, Ran;Oh, Won-Seok;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.26 no.1
    • /
    • pp.23-28
    • /
    • 2009
  • Peritoneal dialysis (PD) is a clinical technique that therapeutically removes toxic solutes from body fluids and normalizes endogenous solutes whose aberrant concentrations disrupt normal physiology. This study retrospectively evaluated clinical outcomes and complications of PD in 20 dogs with renal failure. Blood works (total count of red blood cells (RBC), packed cell volume (PCV), the serum biochemical, and electrolyte values related to renal insufficiency) and complications associated with peritoneal dialysis, and clinical outcomes were recorded before and after PD. Additionally, creatinine reduction ratio (CRR) and urea nitrogen reduction ratio (URR) were calculated for evaluating the efficacy of PD. PD resulted in a significant (p < 0.05) reduction in blood urea nitrogen (BUN) concentration in 19 dogs, while a significant (p < 0.05) reduction in creatinine concentration in 17 dogs. The complications of PD were hypoalbuminemia (12/20, 60%), anemia (10/20, 50%), subcutaneous dialysate leakage (9/20, 45%), bacterial peritonitis (6/20, 30%), dialysate retention (5/20, 25%) and limb edema (4/20, 20%). This study demonstrated that PD was effective in reducing the magnitude of azotemia in dogs with renal failure especially in acute phase, although the complication rate was high but manageable.

Hypoadrenocortical Crisis-like Transient Hyponatremia and Hyperkalemia in a Near-Term Pregnant Dog (분만 직전의 개에서 급성 부신겉질저하증과 유사한 일과성 저나트륨혈증 및 고칼륨혈증 일례)

  • Kang Ji-houn;Kim Min-jun;Cho Min-haeng;Chang Dong-woo;Kang Hyun-gu;Kim Ill-hwa;Na Ki-jeong;Yang Mhan-pyo
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.450-452
    • /
    • 2005
  • A 3-year-old, 43kg, pregnant Great Pyrenese was examined for clinical signs of acute weakness and anorexia for 4 days. The dog was in lateral recumbency at referral. The rectal temperature was within reference range, and the respiratory and heart rates were 36 breaths/min and 58 beats/min, respectively. The abdomen was distended, and several puppies were palpated. The mean fetal head diameter was 2.8cm in the ultrasonographic examination. The initial complete blood count and serum biochemical examinations revealed mild dehydration, mud hyperglycemia, hypochloremia, hyperkalemia, hyponatremia, and low sodium-potassium ratio. Serum BUN and total cholesterol values were slightly high. Hypoadrenocortical crisis was suspected on the basis of signs of acute collapse, hyponatremia and hyperkalemia. Adrenal gland function was evaluated by an ACTH stimulation test. The baseline cortisol concentration was $18.6{\mu}g/dl$ and the concentration at 1 hour after administration of tetracosactrin (ACTH, Synacthen) was $8{\mu}g/dl$. The dog was treated for the correction of assumed hypoadrenocortical crisis and substantial hyperkalemia. In addition to rapid infusion with saline solution, other medications administered intravenously included sodium bicarbonate and cimetidine hydrochloride. The dog was monitored with repeated serum electrolyte examination. After clinical stabilization, cesarean section was performed. All of 13 puppies were delivered, and the dog recovered from anesthesia without complications. The values of postpartum blood tests returned to normal or within reference range. The dog remained healthily.

Study on the Copper Electro-refining from Copper Containing Sludge (저품위 동(Cu) 함유 슬러지로부터 동 전해정련에 관한 연구)

  • Lee, Jin-Yeon;Son, Seong Ho;Park, Sung Cheol;Jung, Yeon Jae;Kim, Yong Hwan;Han, Chul Woong;Lee, Man-seung;Lee, Ki-Woong
    • Resources Recycling
    • /
    • v.26 no.6
    • /
    • pp.84-90
    • /
    • 2017
  • The electro-refining process was performed to recovery high purity copper from low grade copper containing sludge in sulfuric acid. The surface morphologies and roughness of electro-refining copper were analyzed with variation of the type and concentration of organic additives, the best surface morphology was obtained 5 ppm of the gelatin type and 5 to 10 ppm of the thiol type organic additive. The crude metal consisted of copper with 86.635, 94.969 and 99.917 wt.%, several impurity metals of iron, nickel, cobalt and tin by pyro-metallurgical process. After electro-refining process, the purity of copper increases to 3N or 4N grade. The impurity concentrations and copper purities of copper crude metals, electrolyte and electro-refining copper were analyzed using ICP-OES, the electro-refining time and purity of copper crude metal to recover 4N grade copper were deduced.

Optimum dimensionally stable anode with volatilization and electrochemical advanced oxidation for volatile organic compounds treatment (전극의 부반응 기포발생에 따른 휘발특성과 전기화학고도산화능을 동시에 고려한 휘발성 유기화합물 처리용 최적 불용성전극 개발)

  • Cho, Wan-Cheol;Poo, Kyung-Min;Lee, Ji-Eun;Kim, Tae-Nam;Chae, Kyu-Jung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.31-41
    • /
    • 2019
  • Volatile organic compounds(VOCs) are toxic carcinogenic compounds found in wastewater. VOCs require rapid removal because they are easily volatilized during wastewater treatment. Electrochemical advanced oxidation processes(EAOPs) are considered efficient for VOC removal, based on their fast and versatile anodic electrochemical oxidation of pollutants. Many studies have reported the efficiency of removal of various types of pollutants using different anodes, but few studies have examined volatilization of VOCs during EAOPs. This study examined the removal efficiency for VOCs (chloroform, benzene, trichloroethylene and toluene) by oxidization and volatilization under a static stirred, aerated condition and an EAOP to compare the volatility of each compound. The removal efficiency of the optimum anode was determined by comparing the smallest volatilization ratio and the largest oxidization ratio for four different dimensionally stable anodes(DSA): Pt/Ti, $IrO_2/Ti$, $IrO_2/Ti$, and $IrO_2-Ru-Pd/Ti$. EAOP was operated under same current density ($25mA/cm^2$) and electrolyte concentration (0.05 M, as NaCl). The high volatility of the VOCs resulted in removal of more than 90% within 30 min under aerated conditions. For EAOP, the $IrO_2-Ru/Ti$ anode exhibited the highest VOC removal efficiency, at over 98% in 1 h, and the lowest VOC volatilization (less than 5%). Chloroform was the most recalcitrant VOC due to its high volatility and chemical stability, but it was oxidized 99.2% by $IrO_2-Ru/Ti$, 90.2% by $IrO_2-Ru-Pd/Ti$, 78% by $IrO_2/Ti$, and 75.4% by Pt/Ti anodes The oxidation and volatilization ratios of the VOCs indicate that the $IrO_2-Ru/Ti$ anode has superior electrochemical properties for VOC treatment due to its rapid oxidation process and its prevention of bubbling and volatilization of VOCs.

Development and Research into Functional Foods from Hydrolyzed Whey Protein Powder with Sialic Acid as Its Index Component - I. Repeated 90-day Oral Administration Toxicity Test using Rats Administered Hydrolyzed Whey Protein Powder containing Normal Concentration of Sialic Acid (7%) with Enzyme Separation Method - (Sialic Acid를 지표성분으로 하는 유청가수분해단백분말의 기능성식품 개발연구 - I. 효소분리로 7% Siailc Acid가 표준적으로 함유된 유청가수분해단백분말(7%)의 랫드를 이용한 90일 반복경구투여 독성시험 평가 연구 -)

  • Noh, Hye-Ji;Cho, Hyang-Hyun;Kim, Hee-Kyong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.34 no.2
    • /
    • pp.99-116
    • /
    • 2016
  • We herein performed animal safety assessment in accordance with Good Laboratory Practice (GLP) regulations with the aim of developing sialic acid from glycomacropeptide (hereafter referred to as "GMP") as an index ingredient and functional component in functional foods. GMP is a type of whey protein derived from milk and a safe food, with multiple functions, such as antiviral activity. A test substance was produced containing 7% (w/w) sialic acid and mostly-hydrolyzed whey protein (hereafter referred to as "7%-GNANA") by enzymatic treatment of substrate GMP. The maximum intake test dose level was selected based on 5,000 mg/kg/day dose set for male NOEL (no-observed-effect-level) and female NOAEL (no-observed-adverse-effect-level) determined by a dose-range finding (DRF) test (GLP Center of Catholic University of Daegu, Report No. 15-NREO-001) that was previously conducted with the same test substance. To evaluate the toxicity of a repeated oral dose of the test substance in connection with the previous DRF study, 1,250, 2,500, and 5,000 mg/kg of the substance were administered by a probe into the stomachs of 6-week-old SPF Sprague-Dawley male and female rats for 90 d. Each test group consisted of 10 male and 10 female rats. To determine the toxicity index, all parameters, such as observation of common signs; measurements of body weight and food consumption; ophthalmic examination; urinalysis, electrolyte, hematological, and serum biochemical examination; measurement of organ weights during autopsy; and visual and histopathological examinations were conducted according to GLP standards. After evaluating the results based on the test toxicity assessment criteria, it was determined that NOAEL of the test substance, 7%-GNANA, was 5,000 mg/kg/day, for both male and female rats. No animal death was noted in any of the test groups, including the control group, during the study period, and there was no significant difference associated with test substance, as compared with the control group, with respect to general symptoms, body weight changes, food consumption, ophthalmic examination, urinalysis, hematological and serum biochemical examination, and electrolyte and blood coagulation tests during the administration period (P<0.05). As assessed by the effects of the test substance on organ weights, food consumption, autopsy, and histopathological safety, change in kidney weight as an indicator of male NOAEL revealed up to 20% kidney weight increase in the high-dose group (5,000 mg/kg/day) compared with the change in the control group. However, it was concluded that this effect of the test substance was minor. In the case of female rats, reduction of food consumption, increase of kidney weight, and decrease of thymus weight were observed in the high-dose group. The kidney weight increased by 10.2% (left) and 8.9% (right) in the high-dose group, with a slight dose-dependency compared with that of the control group. It was observed that the thymus weight decreased by 25.3% in the high-dose group, but it was a minor test substance-associated effect. During the autopsy, botryoid tumor was detected on the ribs of one subject in the high-dose group, but we concluded that the tumor has been caused by a naturally occurring (non-test) substance. Histopathological examination revealed lesions on the kidney, liver, spleen, and other organs in the low-dose test group. Since these lesions were considered a separate phenomenon, or naturally occurring and associated with aging, it was checked whether any target organ showed clear symptoms caused by the test substance. In conclusion, different concentrations of the test substance were fed to rats and, consequently, it was verified that only a minor effect was associated with the test substance in the high-dose (5,000 mg/kg/day) group of both male and female rats, without any other significant effects associated with the test substance. Therefore, it was concluded that NOAEL of 7%-GNANA (product name: Helicobactrol) with male and female rats as test animals was 5,000 mg/kg/day, and it thus was determined that the substance is safe for the ultimate use as an ingredient of health functional foods.

Investigating the Au-Cu thick layers Electrodeposition Rate with Pulsed Current by Optimization of the Operation Condition

  • Babaei, Hamid;Khosravi, Morteza;Sovizi, Mohamad Reza;Khorramie, Saeid Abedini
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.172-179
    • /
    • 2020
  • The impact of effective parameters on the electrodeposition rate optimization of Au-Cu alloy at high thicknesses on the silver substrate was investigated in the present study. After ensuring the formation of gold alloy deposits with the desired and standard percentage of gold with the cartage of 18K and other standard karats that should be observed in the manufacturing of the gold and jewelry artifacts, comparing the rate of gold-copper deposition by direct and pulsed current was done. The rate of deposition with pulse current was significantly higher than direct current. In this process, the duty cycle parameter was effectively optimized by the "one factor at a time" method to achieve maximum deposition rate. Particular parameters in this work were direct and pulse current densities, bath temperature, concentration of gold and cyanide ions in electrolyte, pH, agitation and wetting agent additive. Scanning electron microscopy (SEM) and surface chemical analysis system (EDS) were used to study the effect of deposition on the cross-sections of the formed layers. The results revealed that the Au-Cu alloy layer formed with concentrations of 6gr·L-1 Au, 55gr·L-1 Cu, 24 gr·L-1 KCN and 1 ml·L-1 Lauryl dimethyl amine oxide (LDAO) in the 0.6 mA·cm-2 average current density and 30% duty cycle, had 0.841 ㎛·min-1 Which was the highest deposition rate. The use of electrodeposition of pure and alloy gold thick layers as a production method can reduce the use of gold metal in the production of hallow gold artifacts, create sophisticated and unique models, and diversify production by maintaining standard karats, hardness, thickness and mechanical strength. This will not only make the process economical, it will also provide significant added value to the gold artifacts. By pulsating of currents and increasing the duty cycle means reducing the pulse off-time, and if the pulse off-time becomes too short, the electric double layer would not have sufficient growth time, and its thickness decreases. These results show the effect of pulsed current on increasing the electrodeposition rate of Au-Cu alloy confirming the previous studies on the effect of pulsed current on increasing the deposition rate of Au-Cu alloy.

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

Development of Particle-level Computer Assisted Instruction Materials for the ‘Solution’ Chapter in High School Chemistry Textbook and Analysis of the Educational Effects (고등학교 화학 교과서의 ‘용액’ 단원에 대한 입자 수준의 컴퓨터 보조 수업자료 개발 및 적용 효과 분석)

  • Baek, Seong-Hye;Kim, Jong-Hyeon;Kim, Jeong-Won;Park, Chan-Geun
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.2
    • /
    • pp.163-177
    • /
    • 2006
  • Alpha Nickel hydroxide samples have been synthesized by electrodeposition on platinum and nickel substrates at current densities of 1, 5, 6, 7 and 10 mAcm?2 at a controlled temperature of 30.00 oC from Ni(NO3)2 bath. Platinum substrate shows a tendency to incorporate less nitrate ions with increase in current density thus producing less hydroxy-deficient nickel hydroxide layers. On the whole the interlayer distance (d003) is found to be inversely proportional to the amount of nitrate ions incorporated in-between the lattice. For the first time we have observed a decrease in lattice spacing with increase in concentration of intercalant (anions) and the reason for lattice contraction is attributed to the columbic attractive forces exerted by the oppositely charged nitrate ion and positively charged slabs. The Infrared spectra of the samples with expanded interlayers show two types of OH vibrations corresponding to hydrogen bonded and non-hydrogen bonded OH groups whereas the contracted interlayers show only hydrogen-boded OH groups. Although the faradaic efficiency is found to increase with increase in applied current there is a local minimum at 6.0 mAcm?2 current density on both platinum and nickel substrates. In this manuscript, GC-MS data is provided which clearly demonstrates the electrodeposited nickel hydroxide sample to consist of huge amount of carbonate ions although the electrolyte solution in nickel nitrate.

Effect of SUS316L Bipolar Plate Corrosion on Contact Resistance and PEMFC Performance (SUS316L 분리판 부식에 의한 접촉저항 및 고분자전해질 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.664-670
    • /
    • 2021
  • Stainless steel was applied as bipolar plate (BP) of polymer electrolyte membrane fuel cell (PEMFC) due to high mechanical strength, electrical conductivity, and good machinability. However, stainless steel was corroded and increased contact resistance resulting PEMFC performance decrease. Although the corrosion resistance could be improved by surface treatment such as noble metal coating, there is a disadvantage of cost increase. The stainless steel corrosion behavior and passive layer influence on PEMFC performance should be studied to improve durability and economics of metal bipolar plate. In this study, SUS316L bipolar plate of 25 cm2 active area was manufactured, and experiments were conducted for corrosion behavior at an anode and cathode. The influence of SUS316L BP corrosion on fuel cell performance was measured using the polarization curve, impedance, and contact resistance. The metal ion concentration in drained water was analyzed during fuel cell operation with SUS316L BP. It was confirmed that the corrosion occurs more severely at the anode than at the cathode for SUS316L BP. The contact resistance was increased due to the passivation of SUS316L during fuel cell operation, and metal ions continuously dissolved even after the passive layer formation.

Influences of the Global Deterioration Scale according to Routine Blood Chemistry Results (통상적 혈액화학 결과에서 전반적 퇴화 척도의 영향성)

  • Kim, Sun-Gyu;Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.3
    • /
    • pp.351-359
    • /
    • 2019
  • Neurocognitive testing commonly uses the MMSE (Mini-Mental State Examination) to evaluate the overall cognitive function of patients at outpatient clinics, but the MMSE has recently been extensively used in the SNSB II (Seoul Neuropsychological Screening Battery II) for making diagnoses. We retrospectively investigated the results of routine neurocognitive tests and the results of the blood tests of 120 elderly patients who had been referred to a South Central Medical Center from 2017 to 2018 and who had been examined at a public health center. These subjects' space-time capability was high on the sub-region of the global deterioration scale (GDS). GDS showed a significant increase as the Na decreased on the electrolyte analysis. The subjects' concentration, their language-based orientation for space and time, their memory, and their scores for the frontal lobe function on GDS showed statistically significant reductions (P<0.001) For the normal and abnormal groups according to the ALT and creatinine levels, the frontal/execute function areas showed statistically significant differences (P<0.001) as well as negative correlation between GDS and ALT (P<0.01). In conclusion, this study provides basic information to develop test items that are important for patient screening and diagnosis, and several routine blood chemistry factors provide basic information for diagnosing and assessing the status and progress of cognitively impaired patients.