• Title/Summary/Keyword: High-Assurance

Search Result 387, Processing Time 0.026 seconds

Quality Assurance Strategy for AGO Program in Korea (AGD(통합치과전문임상의)교육 프로그램 질 보장 방안)

  • Shin, Je-Won
    • The Journal of the Korean dental association
    • /
    • v.48 no.11
    • /
    • pp.790-796
    • /
    • 2010
  • Currently, KDA adopted new post-graduated program; advanced education general dentistry(AGD) for 3 years preparation. The AGO program provides the resident the opportunity to deliver the highest quality of comprehensive dental care to the broadest range of the population with a knowledge, comfort, and ease in treating the high risk patient. The purpose of this article is to study the assurance systems of AGO programs in USA and Japan and to suggest a piece of advice whether we choose the way of AGO program assurance system in Korea.

A Bulk Sampling Plan for Reliability Assurance (벌크재료의 신뢰성보증을 위한 샘플링검사 방식)

  • Kim, Dong-Chul;Kim, Jong-Gurl
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.2
    • /
    • pp.123-134
    • /
    • 2007
  • This paper focuses on the in-house reliability assurance plan for the bulk materials of each company. The reliability assurance needs in essence a long time and high cost for testing the materials. In order to reduce the time and cost, accelerated life test is adopted. The bulk sampling technique was used for acceptance. Design parameters might be total sample size(segments and increments}, stress level and so on. We focus on deciding the sample size by minimizing the asymptotic variance of test statistics as well as satisfying the consumer's risk. In bulk sampling, we also induce the sample size by adapting the normal life time distribution model when the variable of the lognormal life time distribution is transformed and adapted to the model. In addition, the sample size for both the segments and increments can be induced by minimizing the asymptotic variance of test statistics of the segments and increments with consumer's risk met. We can assure the reliability of the mean life and B100p life time of the bulk materials by using the calculated minimum sample size.

How Through-Process Optimization (TPO) Assists to Meet Product Quality

  • Klaus Jax;Yuyou Zhai;Wolfgang Oberaigner
    • Corrosion Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.131-138
    • /
    • 2024
  • This paper introduces Primetals Technologies' Through-Process Optimization (TPO) Services and Through-Process Quality Control (TPQC) System, which integrate domain knowledge, software, and automation expertise to assist steel producers in achieving operational excellence. TPQC collects high-resolution process and product data from the entire production route, providing visualizations and facilitating quality assurance. It also enables the application of artificial intelligence techniques to optimize processes, accelerate steel grade development, and enhance product quality. The main objective of TPO is to grow and digitize operational know-how, increase profitability, and better meet customer needs. The paper describes the contribution of these systems to achieving operational excellence, with a focus on quality assurance. Transparent and traceable production data is used for manual and automatic quality evaluation, resulting in product quality status and guiding the product disposition process. Deviation management is supported by rule-based and AI-based assistants, along with monitoring, alarming, and reporting functions ensuring early recognition of deviations. Embedded root cause proposals and their corrective and compensatory actions facilitate decision support to maintain product quality. Quality indicators and predictive quality models further enhance the efficiency of the quality assurance process. Utilizing the quality assurance software package, TPQC acts as a "one-truth" platform for product quality key players.

Bearing Capacity Evaluation of the Drilled Shaft Using Small Scale Model Test (축소모형말뚝을 이용한 현장타설말뚝의 지지력 평가)

  • 조천환;김홍묵;김웅규
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.5
    • /
    • pp.117-126
    • /
    • 2004
  • Recently, the top & down method with drilled shafts as a foundation of high rise building is often adopted for the purpose of construction period reduction and construction cost effectiveness. It is common to omit the loading test as a quality assurance on account of the high capacity of drilled shafts for the top & down method. It seems that the capacity of drilled shaft in recent top & down method is beyond that of conventional loading test method. However, the quality assurance for the drilled shaft as foundation of high rise building becomes much more important since the drilled shaft should bear much higher working load. A small scale test pile can be an alternative as a quality assurance for the drilled shaft with hish capacities. Through a case study, this paper gives an idea for solving the limitation of the conventional loading test method for the quality assurance of drilled shaft with high capacities. In particular, this paper analyzed the scale effect for a small drilled shaft installed into bedrock, which could be used for an alternative.

A novel method for determining dose distribution on panoramic reconstruction computed tomography images from radiotherapy computed tomography

  • Hiroyuki Okamoto;Madoka Sakuramachi;Wakako Yatsuoka;Takao Ueno;Kouji Katsura;Naoya Murakami;Satoshi Nakamura;Kotaro Iijima;Takahito Chiba;Hiroki Nakayama;Yasunori Shuto;Yuki Takano;Yuta Kobayashi;Hironori Kishida;Yuka Urago;Masato Nishitani;Shuka Nishina;Koushin Arai;Hiroshi Igaki
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.129-137
    • /
    • 2024
  • Purpose: Patients with head and neck cancer (HNC) who undergo dental procedures during radiotherapy (RT) face an increased risk of developing osteoradionecrosis (ORN). Accordingly, new tools must be developed to extract critical information regarding the dose delivered to the teeth and mandible. This article proposes a novel approach for visualizing 3-dimensional planned dose distributions on panoramic reconstruction computed tomography (pCT) images. Materials and Methods: Four patients with HNC who underwent volumetric modulated arc therapy were included. One patient experienced ORN and required the extraction of teeth after RT. In the study approach, the dental arch curve (DAC) was defined using an open-source platform. Subsequently, pCT images and dose distributions were generated based on the new coordinate system. All teeth and mandibles were delineated on both the original CT and pCT images. To evaluate the consistency of dose metrics, the Mann-Whitney U test and Student t-test were employed. Results: A total of 61 teeth and 4 mandibles were evaluated. The correlation coefficient between the 2 methods was 0.999, and no statistically significant difference was observed (P>0.05). This method facilitated a straightforward and intuitive understanding of the delivered dose. In 1 patient, ORN corresponded to the region of the root and the gum receiving a high dosage (approximately 70 Gy). Conclusion: The proposed method particularly benefits dentists involved in the management of patients with HNC. It enables the visualization of a 3-dimensional dose distribution in the teeth and mandible on pCT, enhancing the understanding of the dose delivered during RT.

Difference of Risk-relievers between High Risk and Low Risk in Online Purchasing

  • Fang, Hua-Long;Kwon, Sun-Dong;Bae, Kee-Su
    • Journal of Information Technology Applications and Management
    • /
    • v.21 no.3
    • /
    • pp.135-156
    • /
    • 2014
  • The Online business model for purchasing agent service is getting more popular. However, consumers perceive more risk when buying products from foreign online purchasing agents (FOPA) than from common online sellers (COS). This study focuses on finding out how consumers manage risk when they perceive risk and what different risk-reliever strategies they use when buying from high-risk FOPA and low-risk COS. This study has proved the following two. First, when consumers perceive risk at online purchasing, they tend to select risk-reliever strategies, such as the use of communication media, online assurance mark, seller's record, and secure payment to mitigate risk. With the application of those risk-reliever strategies, they built trust with the seller. Second, risk-perception of FOPA influences usage of communication media and check of online assurance mark more strongly than that of COS. On the contrary, risk-perception of COS influences the check of seller record more strongly than that of FOPA. This study helps to explain why FOPA is proliferating, despite its inherent high risk due to the fact that buyers and sellers are separated in time and space and that buyers and sellers have different social and cultural backgrounds. This study also helps managers of E-commerce to relieve consumer's risk-perception and to build trust.

Ensuring the Quality of Higher Education in the United Kingdom Using Informatization

  • Andreikova, Iryna;Moiseienko, Natalia;Boichuk, Petro;Iliichuk, Liubomyra;Fedchenko, Karina;Bezliudnyi, Oleksandr;Sopivnyk, Ruslan
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.11
    • /
    • pp.324-330
    • /
    • 2022
  • The United Kingdom is known for the quality of its qualifications. There is a strict quality system with reputable bodies responsible for ensuring that high quality standards are met. In order for new qualifications to be accredited, they must meet all the requirements set out in the regulations for the quality and informatization of Education. The crucial role of the Agency for Quality Assurance of Higher Education (QAA) in the UK for creating high-quality management of higher education institutions is revealed, the influence of informatization tools on its effective mechanism as an independent entity is shown, and positive experience for the educational sector is highlighted. While the universities themselves are responsible for reviewing educational programs at the subject level, the QAA review focuses on verifying internal quality assurance, as well as systems and improvement strategies. The QAA uses a peer review process in which teams mostly consist of academic staff from other institutions to assess the quality of the institution's education. In Scotland, the team also includes an international reviewer. The student is also a member of the Scottish teams. In the UK, attention is paid to providing a cohort of experienced reviewers who can conduct high-quality monitoring and help with advice on improving education. All reviewers must complete training and have permission to participate in the review of educational programs. There are selected committees that are members of the QAA council, each of which is headed by a member of the Council or an independent person approved by the Council. Attention is drawn to the main areas of the QAA's work in the framework of environmental, social and corporate governance.

A Study on Quality Assurance for Gamma Knife (감마나이프 정도관리에 관한 연구)

  • 서원섭;신동오;지영훈;임영진
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.184-188
    • /
    • 2003
  • It is strongly recommended that periodic quality assurance should be carried out in the Gamma Knife that is used in radiosurgery since high radiation is delivered in one session. Since the protocols for Gamma Knife recommended by associations or agencies on quality assurance are absent in Korea, hospitals possessing the Gamma Knife have developed their own protocols. In order to develop a quality assurance protocol suitable for Korea, we reviewed the protocols of the Gamma Knife manufacturer, USA and Japan. we categorized the periodic items into three parts,: radiation dose, mechanical and safety part. The USA recommended and regulated more strict than the manufacturer. Japan recommended the items and frequency based on the USA. In conclusion, we tried to suggest a basic Gamma Knife quality assurance protocol suitable for Korea.

  • PDF

Evaluation of the Utility of a Volumetric Modulated Arc Therapy Specific Patient Quality Assurance using Software-based Quality Assurance System (소프트웨어 기반 정도관리 시스템을 이용한 부피세기조절회전치료 환자 별 정도관리의 유용성 평가)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Kwon, Kyung-Tae
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.39-45
    • /
    • 2018
  • The purpose of this study is to evaluate the usefulness of a software-based quality assurance system based on Volumetric Modulated Arc Therapy treatment plan. Evaluate treatment plan through the D VH analysis, PTV mean dose ($D_{mean}$) and PTV 95% dose($D_{95}$) compare the MFX based on original treatment plan, Average error rate was $0.9{\pm}0.6%$, $1.0{\pm}0.8%$, respectively. Measuring point dose using phantom and ion chamber, the average error rate between the ionization chamber and MFX was $0.9{\pm}0.7%$, $1.1{\pm}0.7%$ (high dose region), $1.1{\pm}0.9%$, $1.2{\pm}0.7%$ (low dose region). The average gamma though of MFX and $Delta^{4PT}$ is $98.7{\pm}1.2%$, $98.4{\pm}.3%$, respectively. Through this study, A software based QA system that simplifies hardware based QA procedures that involve a lot of time and effort. It can be used as a simple and useful tool in clinical practice.