• 제목/요약/키워드: High windows

검색결과 723건 처리시간 0.028초

Energy demand analysis according to window size and performance for Korean multi-family buildings

  • Huh, Jung-Ho;Mun, Sun-Hye
    • Architectural research
    • /
    • 제15권4호
    • /
    • pp.201-206
    • /
    • 2013
  • Special attention is required for the design of windows due to their high thermal vulnerability. This paper examines the problems that might arise in the application of the u-value, by reflecting the changes in the u-value of the window, depending on the window-to-wall ratio obtained in an energy demand analysis. Research indicates that the u-value of a window increases with an increase in the difference between the u-values of the frames and the glass. Relative to the changes in the u-value of the windows, the energy demand varied from 1.3% to 9.3%. Windows with a g-value of 0.3 or 0.5 displayed a higher energy demand than windows with a g-value of 0.7. Therefore, when the difference between the performance of the glass and the frame is significant, especially when the g-value is small, a modified heat transmission coefficient should be applied to the window size during the evaluation of the building energy demand.

Windows NT 운영체제 커널에서 Disk mirroring 기능 설계 (The design of disk mirroring function in Windows NT kernel)

  • 김성관;장승주;지동해;김학영;이정배;노영욱
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 1999년도 가을 학술발표논문집 Vol.26 No.2 (3)
    • /
    • pp.117-119
    • /
    • 1999
  • Disk mirroring 시스템은 안정성과 고 가용성(High Availability)을 제공하기 때문에 고성능 시스템에서 많이 사용되고 있다. 본 논문에서는 Windows NT 커널에 remote node에 대한 disk mirroring 기능을 추가하여 시스템 자체에서 이러한 기능을 제공할 수 있는 모델을 설계하고자 한다. 설계 시스템은 Windows NT TDI 계층을 사용하여 network 으로 연결된 두 대의 시스템이 master node와 slave node의 pair로 구성되며,slave node가 master node의 디스크를 mirror하게 된다. 또한 fault tolerance 기능을 제공하여 node의 장애 발생시 log를 생성하고, 이 정보를 바탕으로 장애가 발생한 node에 대하여 데이터 복구 기능을 제공하도록 한다.

  • PDF

Earthquake performance of FRP retrofitting of short columns around band-type windows

  • Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • 제53권1호
    • /
    • pp.1-16
    • /
    • 2015
  • Due to design codes and regulations and the variety of building plans in Turkey, it is very often seen that band-type windows are left for ventilation and lightening of the basements of buildings which are used for various purposes such as workplaces and storage. Therefore when the necessary support measures cannot be given, short columns are subjected to very high shear forces and so damage occurs. One of the precautions to avoid the damage of short column mechanisms in buildings where band-type windows are in the basement is to strengthen the short columns with fiber reinforced polymer (FRP). In this study, the effect of the FRP retrofitting process of the short columns around band-windowed structures, which are found especially in basement areas, is analyzed in accordance with Turkish Seismic Code 2007 (TSC 2007). Three different models which are bare frame, frame with short columns and retrofitted short columns with FRP, are created and analyzed according to TSC 2007 performance analysis methods to understand the effects of band windows in basements and the effect of FRP retrofitting.

A Fall Detection Technique using Features from Multiple Sliding Windows

  • Pant, Sudarshan;Kim, Jinsoo;Lee, Sangdon
    • 스마트미디어저널
    • /
    • 제7권4호
    • /
    • pp.79-89
    • /
    • 2018
  • In recent years, falls among elderly people have gained serious attention as a major cause of injuries. Falls often lead to fatal consequences due to lack of prompt response and rescue. Therefore, a more accurate fall detection system and an effective feature extraction technique are required to prevent and reduce the risk of such incidents. In this paper, we proposed an efficient feature extraction technique based on multiple sliding windows and validated it through a series of experiments using supervised learning algorithms. The experiments were conducted using the public datasets obtained from tri-axial accelerometers. The results depicted that extraction of the feature from adjacent sliding windows led to high accuracy in supervised machine learning-based fall detection. Also, the experiments conducted in this study suggested that the best accuracy can be achieved by keeping the window size as small as 2 seconds. With the kNN classifier and dataset from wearable sensors, the experiments achieved accuracy rates of 94%.

Timoshenko 이론과 유한요소법을 이용한 모터내장형 고속주축계의 정특성/동특성 해석시스템 개발 (Development of a Static and Dynamic Analysis System for Motor-Integrated High-Speed Spindle Systems Using Timoshenko Theory and Finite Element Method)

  • 이용희;김석일;김태형;이재윤
    • 한국정밀공학회지
    • /
    • 제15권8호
    • /
    • pp.11-16
    • /
    • 1998
  • Recently, the motor-integrated spindle systems have been used to simplify the machine tool structure, to improve the motion flexibility of machine tool, and to perform the high-speed machining. In this study, a static and dynamic analysis system for motor-integrated high-speed spindle systems is developed based on Timoshenko theory, finite element method and windows programming techniques. Since the system has various analysis modules related to static deformation analysis, modal analysis, frequency response analysis, unbalance response analysis and so on, it is useful in performing systematically the design and evaluation processes of motor-integrated high-speed spindle systems under windows GUI environment.

  • PDF

윈도우즈 GUI 환경을 이용한 모터내장형 고속주축계의 정특성/동특성 해석시스템 개발

  • 이용희;김석일;이재윤
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.836-840
    • /
    • 1995
  • Recently, the motor-integrated spindle spindle systems have been used to simplify the machine tool structure, to improve the motion flexibility of machine tool, and to perform the high-speed machining. In this study, a static and dynamic analysis system for motor-integrated high-speed spindle systems is developed based on Timoshenko theory, finite element method and windows programming techniques. Since the system has various analysis modules related to static deformation analysis, modal analysis, frequency response analysis, unbalance response analysis and so on, it is useful in performing systematically the design and evaluation processes of motor-integrated high-speed spindle systems under windows GUI encironment.

  • PDF

WINDOWS CE .NET 기반의 PDA를 이용한 원격제어시스템 개발 (A Development of Remote Control System using PDA based WINDOWS CE .NET)

  • 양원석;이유상;전재욱;문일현;전창완;안달;임종식;최관순
    • 한국산학기술학회논문지
    • /
    • 제8권6호
    • /
    • pp.1480-1490
    • /
    • 2007
  • 본 논문에서는 WINDOWS CE .NET 기반의 PDA를 이용한 원격제어시스템을 구현하였다. 서버 시스템의 운영체제는 WINDOWS CE .NET을 사용하여 사용자에게 쉬운 사용 환경을 제공하며, 운영체제 이미지에 개발한 디바이스 드라이버를 추가하여 하드웨어 장치를 제어한다. 임베디드 서버는 PC 클라이언트와 PC 클라이언트, PC 클라이언트와 PDA 클라이언트, PDA 클라이언트와 PDA 클라이언트간의 메시지 통신을 지원한다. 본 논문은 원격제어시스템을 구현하는데 있어서 에뮬레이터를 사용하지 않고 실제 PDA와 임베디드 보드로 시스템을 구현하였다. 제안된 시스템은 임베디드 보드를 서버로 사용하고 PDA를 클라이언트로 사용하여 무선 인터넷이 제공되는 환경이라면 어느 곳에서나 원격으로 대상물을 제어할 수 있다.

  • PDF

GUI 환경의 고성능 워드프로세서의 발전 방향에 관한 연구 (A Study on the Enhancement of GUI Based High-end Word processor)

  • 홍원기;이상렬
    • 한국컴퓨터정보학회지
    • /
    • 제2권2호
    • /
    • pp.19-26
    • /
    • 1996
  • 윈도우 등 GUI 환경이 급속히 보급됨에 따라 워드프로세서도 매우 발전하고 있다. 이에 따라 본 논문에서는 현재 보급된 윈도우용 워드프로세서를 분석하여 문제점과 개선점을 제시하고 멀티미디어 시대에 대응한 워드프로세서의 방향에 대하여 고찰하고자 한다.

  • PDF

시뮬레이션 분석기법을 이용한 주거용 건물의 공간별 채광성능 연구 (Space study on Lighting Performance For Residential Buildings By using Simulation Analysis)

  • 임태섭;임정희;김병선
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.97-104
    • /
    • 2013
  • This proposed simulation-based design study is based on the design of residential high-rise buildings in South-Korea. the purpose of this study is to evaluate the amount of daylighting performance passing through building glazing according to sky conditions, orientation of windows and each space of Apartment buildings. The clear sky includes sunshine and is intense and brighter at the horizon than at the zenith, except in the area around the sun. Daylight received within a building is directly dependent upon the sun's position and the atmospheric conditions. Orientation of the building generally used to refer to solar orientation which is the siting of building with respect to solar access. Although any building will have different orientations for its different sides, the orientation can refer to a particular room, or to the most important facade of the building. north-facing windows receive twice the winter sun than east and west facing windows, allowing light and warmth into the home. They can be easily shaded from the high summer sun to help keep the house cool. Ideally, the glazing area should be between 10-25% of the floor area of the room. This paper was calculated by a Desktop Radiance program. The space dimensions were based on a unit module of real constructed apartment having divided into five sections such as living room, room1, room2, room3 and kitchen.