Study on Standardization of the Environmental Impact Evaluation Method of Extremely Low Frequency Magnetic Fields near High Voltage Overhead Transmission Lines (고압 가공송전선로의 극저주파자기장 환경영향평가 방법 표준화에 관한 연구)

  • Park, Sung-Ae;Jung, Joonsig;Choi, Taebong;Jeong, Minjoo;Kim, Bu-Kyung;Lee, Jongchun
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.658-673
    • /
    • 2018
  • Social conflicts with extremely low frequency magnetic field(ELF-MF) exposures are expected to exacerbate due to continued increase in electric power demand and construction of high voltage transmission lines(HVTL). However, in current environmental impact assessment(EIA) act, specific guidelines have not been included concretely about EIA of ELF-MF. Therefore, this study conducted a standardization study on EIA method through case analysis, field measurement, and expert consultation of the EIA for the ELF-MF near HVTL which is the main cause of exposures. The status of the EIA of the ELF-MF and the problem to be improved are derived and the EIA method which can solve it is suggested. The main contents of the study is that the physical characteristics of the ELF-MF affected by distance and powerload should be considered at all stages of EIA(survey of the current situation - Prediction of the impacts - preparation of mitigation plan ? post EIA planning). Based on this study, we also suggested the 'Measurement method for extremely low frequency magnetic field on transmission line' and 'Table for extremely low frequency magnetic field measurement record on transmission line'. The results of this study can be applied to the EIA that minimizes the damage and conflict to the construction of transmission line and derives rational measures at the present time when the human hazard to long term exposure of the ELF-MF is unclear.

Evaluation of Extremely Low Frequency Magnetic Fields emission Level from High Voltage Transmission Lines (고압 송전선로에서 극저주파 자기장 영향평가 적용에 관한 연구)

  • Jung, Joon Sig;Choi, Sung Ho;Jeon, Hyung Jin;Kim, Yoon Shin;Hong, Seung Cheol
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.5
    • /
    • pp.353-363
    • /
    • 2014
  • The purpose of this study was to investigated the ELF-MF emission level of various environments such as 258 facilities near located to high voltage transmission lines and 120 high voltage transmission lines, 17 underground cable lines. In addition, ELF-MF reduction rate according to separation distance was calculated by using simulations. An appropriate separation distance showing below 4mG was at least 70m. In the case of the appropriate separation distance for 120 high voltage transmission lines, 154kV required 20m of separation distance and 345kV required 60m of separation distance. The simulation results showed that the appropriate separation distance showing below 4mG was 40m and 60m for overhead 154kV and 345kV respectively. To adjust the worst conditions considering the aspects of environmental impact assessment study and the electric power currents that will increase in the future, the appropriate minimum separation distance for HVTL is judged to be above 70m in this study. Thus, there is a need to establish the greenbelt or buffer zone within 70m so as to create an environment in which the receptors are not exposed and thereby eliminate the risk factors of ELF-MF against humans.