• 제목/요약/키워드: High voltage motor

검색결과 799건 처리시간 0.038초

Analysis on the Switching Surge Characteristics of a High-Voltage Induction Motor Fed by PWM Inverter Using EMTP

  • Kim Jae-Chul;Song Seung-Yeop;Lee Do-Hoon
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권1호
    • /
    • pp.22-30
    • /
    • 2005
  • The PWM inverter drive may cause an over voltage at the motor terminal, which imposes severe electric stresses on the inter-turn insulation of motor windings. Unlike low-voltage induction motors, high-voltage induction motors have a stator type of form-wound coil for insulation and are insulated to the slot and the coil. So, this paper presents a PWM 3-level inverter, H-Bridge cascaded 7-level inverter and High-voltage induction motor model. It then analyzes the voltage that generates at the input terminal of the high-voltage induction motor fed by each inverter. Also, in order to examine a factor that influences the switching surge voltage, this paper proposes the system equivalent model and performs the case studies using EMTP.

멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감을 위한 RC필터의 효과분석 (Analysis on the effect of RC filter to mitigate transient overvoltage on the high voltage induction motor fed by Multi level inverter)

  • 권영목;김재철;김용성;이양진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.399-403
    • /
    • 2005
  • In this paper, we analyze on the effect of RC filter to mitigate transient overvoltage on the high voltage induction motor fed by H-bridge cascaded 7-level inverter. The switching surge voltage becomes the major cause to occur the insulation failure by serious voltage stress in the stator winding of high voltage induction motor. The effect of switching surge appears more serious in high voltage induction motor than low voltage induction motor. Consequently, we demonstrated that the RC filter connected to the motor terminals greatly reduces the transient voltage stress md ringing. The results of simulation show the suppression of transient overvoltage at the motor end of a long cable. using EMTP

  • PDF

EMTP를 이용한 멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감필터의 효과분석 (Analysis on the Effect of Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter using EMTP)

  • 권영목;김재철
    • 조명전기설비학회논문지
    • /
    • 제20권10호
    • /
    • pp.82-93
    • /
    • 2006
  • 본 논문에서는 인버터 구동 고압유도전동기 운전시 스위칭 서지로 인하여 고압유도 전동기 단자에서 발생하는 과도과전압을 저감하기 위한 필터로 인버터 출력단자에서 dv/dt를 저감하는 LCR 필터와 전동기 입력단자에서 케이블과 유도전동기 특성임피던스를 매칭시키는 RC필터에 대한 과도과전압 저감특성을 분석하였다. 이 필터를 고압에 대용량 유도전동기에 적합하도록 EMTP(ElectroMagnetic Transients Program)를 이용하여 모델링 및 케이블 영향에 의한 필터의 과도과전압 저감효과를 전압파형과 고조파 스펙트럼으로 비교분석하고, 이를 토대로 고압 대용량 유도전동기에 사용될 필터를 제시하였다. 인버터 스위칭 서지에 의한 과도과전압은 유도전동기 고정자 권선에 심각한 전압 스트레스를 발생시켜 절연파괴를 일으키는 주요원인이 된다. 이러한 과도과전압을 저감위한 필터설계는 고압유도전동기 시스템에서 필수적인 요소임을 보였다. 또한 제시된 필터는 과도과전압을 효과적으로 저감시키는 것을 EMTP 시뮬레이션을 통하여 입증하였다.

H-Bridge 7-레벨 인버터 구동시 고압 유도전동기에서 발생하는 과도전압 저감을 위한 필터기술 (Filtering Techniques to Reduce the Transient Voltage of High Voltage Induction Motor on H-bridge cascaded 7- level Inverte)

  • 권영목;김재철;김용성;이양진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.47-50
    • /
    • 2005
  • In this paper, we investigate a filtering technique to reduce the adverse effect of long motor leads on H-bridge cascaded 7-level inverter fed ac motor drive. The switching surge voltage becomes the major cause to occur the insulation failure by serious voltage stress in the stator winding of high voltage induction motor. However, the effect of switching surge appears un seriousin high voltage induction motor than low voltage induction motor. Consequently, we demonstrated that the filter connected to the motor terminals greatly reduces the transient voltage stress and ringing, moreover we show lowers the dv/dt of the inverter switching pulse. The results of simulation show the suppression of dv/dt and the reduced peak voltage at the motor end of a long cable.

  • PDF

전압형 인버터의 출력전압 상승률 억제를 위한 출력 필터의 설계 (Output Filter Design for Suppression of High Voltage Gradient in the Voltage-Fed PWM Inverter)

  • 김성준;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.296-298
    • /
    • 1995
  • This paper proposes a new filter topology that suppresses the high voltage gradient(dv/dt) in ac motor terminals. The high voltage gradient(dv/dt) causes over voltages on the motor windings, the degradation or motor insulation, and the bearing failure. Moreover surge voltage with high voltage gradient(dv/dt) in the PWM inverter red drive system where long line cables are required causes more serious problem to the motor. Thus, the most advisable method is attaching output filter to the inverter output terminals. The conventional output filters have several problems such as bulky size, difficulty or parameter tuning. The proposed filter can be relatively smaller than the conventional filters. By the proposed filter, the shaping or PWM waveform can considerably suppress high dv/dt in motor feeding cable from the inverter. The effectiveness or the proposed filter is compared with that or the conventional one and is verified by the computer simulation.

  • PDF

3상 유도전동기 구동장치의 동상모드 전류 능동 제거법 (An Active Cancellation Method for the Common Mode Current of the Three-Phase Induction Motor Drives)

  • Uzzaman, Tawfique;Kim, Unghoe;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 추계학술대회
    • /
    • pp.96-97
    • /
    • 2019
  • Pulse Width Modulation (PWM) is a widely adopted technique to drive the motor using the voltage source inverters. Since they generate high frequency Common Mode (CM) Voltage, a high shaft voltage in induction motor is induced which leads to parasitic capacitive currents causing adverse effects such as premature deterioration of ball bearings and high levels of electromagnetic emissions. This paper presents an Active Cancellation Circuit (ACC) which can significantly reduce the CM voltage hence the common mode current in the three phase induction motor drives. In the proposed method the CM voltage is detected by the capacitors and applied to the frame of the motor to cancel the CM voltage hence the CM current. Unlike the conventional methods the proposed method does not insert the transformer in between the inverter and motor, a high power rating three phase transformer is not required and no losses associated with it. In addition the proposed method is applicable to any kind of PWM motor drives regardless of their PWM methods. The effectiveness of the proposed method is proved by the experiments with a three phase induction motor (1.1kW 415V/60Hz) combined with a three phase voltage source inverter modulated by the Space Vector Modulation (SVM).

  • PDF

인버터 구동 고압 유도전동기의 케이블 포설시 스위칭 써지 특성 분석 (Analysis on the Switching Surge characteristic of Cable Pulling of High-Voltage Induction Motor Fed by Inverter)

  • 권영목;김재철;송승엽;신중은
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.63-65
    • /
    • 2004
  • The recent advancement in the power electronic technique has increased the use of induction motor fed by inverter using high-frequency switching devices. Also the tendency is toward larger size and higher voltage. Therefore, The IGBT (Insulated-Gate Bipolar Transistor) that is high switching frequency element has been using increase. But, The switching surge voltage was occurred by high switching frequency of inverter has appeared a voltage doubling in the motor input terminal due to mismatching of cable characteristic impedance and motor characteristic impedance. Actually, The Switching surge voltage became the major cause to occur the insulation failure by serious voltage stress in the stator winding of induction motor. The short during rise time of switching surge and cable length is increased, the maximum transient voltage seen at the motor terminals increases. In this paper, Analyzed switching surge transient voltage of power cable pulling is used EMTP(Electromagnetic Transient Program) at the induction motor terminal and in cable.

  • PDF

MPM을 이용한 고압전동기 운전중 상태 평가 (On-Line Assessment of High Voltage Motor Condition using the Motor Performance Monitor)

  • 김희동;공태식
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1589-1593
    • /
    • 2008
  • The condition of a high voltage motor was monitored with the motor performance monitor (MPM) at the motor control center. The MPM detected defects in the rotor bar and end ring and input power according to motor and load conditions. The assessment of the condition of a coal pulverizer motor indicated it was clearly in good condition in terms of the rotor bars, over voltage, and motor performance. However, the side bands at frequency, 56.48 Hz indicated existence of rotor end-ring fault. The large torque ripple indicated abnormal operating conditions. After visual inspection, it has been observed that an impeller blade of the circulating water pump was broken off causing the irregular torque pattern.

고압전동기 절연진단 해석 (II) (Analysis of Insulation Diagnostic Test for High Voltage motor (II))

  • 이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2107-2109
    • /
    • 1999
  • The insulation diagnostic tests was performed at local thermal power plants high voltage motor. The insulation diagnostic tests include measurements of insulation resistance, polarization index, AC current, $tan{\delta}$, partial discharges. This paper describes Insulation characteristics for high voltage motor which located by inside and outside.

  • PDF

A Novel High-Performance Strategy for A Sensorless AC Motor Drive

  • Lee, Dong-Hee;Kwon, Young-Ahn
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제2B권3호
    • /
    • pp.81-89
    • /
    • 2002
  • The sensorless AC motor drive is a popular topic of study due to the cost and reliability of speed and position sensors. Most sensorless algorithms are based on the mathematical modeling of motors including electrical variables such as phase current and voltage. Therefore, the accuracy of such variables largely affects the performance of the sensorless AC motor drive. However, the output voltage of the SVPWM-VSI, which is widely used in sensorless AC motor drives, has considerable errors. In particular, the SVPWM-VSI is error-prone in the low speed range because the constant DC link voltage causes poor resolution in a low output voltage command and the output voltage is distorted due to dead time and voltage drop. This paper investigates a novel high-performance strategy for overcoming these problems in a sensorless ac motor drive. In this paper, a variation of the DC link voltage and a direct compensation for dead time and voltage drop are proposed. The variable DC link voltage leads to an improved resolution of the inverter output voltage, especially in the motor's low speed range. The direct compensation for dead time and voltage drop directly calculates the duration of the switching voltage vector without the modification of the reference voltage and needs no additional circuits. In addition, the proposed strategy reduces a current ripple, which deteriorates the accuracy of a monitored current and causes torque ripple and additional loss. Simulation and experimentation have been performed to verify the proposed strategy.