• 제목/요약/키워드: High turbidity

검색결과 493건 처리시간 0.029초

정수처리공정 전처리로서의 공극제어 섬유여과기(PCF)의 적용 (Application of Pore-controllable Fiber Filter(PCF) as a Pretreatment for Water Treatment Process)

  • 이철우;이병구;이일국;이순화;배상대;강임석
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.235-244
    • /
    • 2006
  • A PCF(Pore Controllable Fiber Filter) process was applied as a pretreatment of water treatment for reduction of turbidity. The experimental results obtained from the PCF showed that the removal efficiency of turbidity without coagulation was around over 70 percent. However, the removal efficiency of turbidity by the coagulation-PCF process was high as much as over 95%. Thus, the coagulation pretreatment was required for the better operation of the PCF. The SEM (Scanning Electron Microscope) images of fiber before and after filtration showed that the filtration mechanism of PCF filter is both controlling attachment mechanism and Sieving mechanism through fiber pore. For the coagulation-PCF process, optimum dosage of coagulant was needed for the economical operation, and for this, determining the optimum dosage by using a filter column test. Also only 16mg/L of alum was used to obtain high algae removal efficiency over 90%. Therefore, it can be concluded that coagulation-PCF process is very effective pretreatment process for algae removal.

급속여과공정에서의 여과보조제 사용에 따른 여과특성 (Characteristics of High-Rate Filtration with Filtration Aids)

  • 안종호;윤재흥
    • 상하수도학회지
    • /
    • 제14권3호
    • /
    • pp.260-270
    • /
    • 2000
  • The objective of this study is to evaluate the effect of filter aids in the dual-media rapid filtration. Paper-filter tests were conducted to determine the proper dosages of coagulant and filter aid, and pilot plant tests using two dual-media filter columns were performed for a variety of filtration rates. Using a filter aid (non-ionic polymer), the maximum feasible filtration rate is 480m/day, while turbidity is less than 0.3 NTU and filter run-time is about 70 hours. It is possible to increase the filtration rate up to 360 m/day for keeping the turbidity less than 0.1 NTU. Turbidity increases for the filtration rate greater than 360m/day. In general, the quality of filtered water with a filter aid is stable, while the filter maintains a sufficient filter run-time for a maximum allowable head loss. Particularly, the initial breakthrough can be effectively controlled. The use of a filter aid may be one of the methods applicable if the turbidity of filtered water is required to be improved or if the filter breakthrough limits filter run-time.

  • PDF

정수처리공정의 침전법을 개선하기 위한 대체공정으로 용존공기부상법(DAF)을 사용할 때 여러조건에 대한 처리효율 비교 (Comparison of Removal Rates of Sedimentation and DAF(Dissolved Air Flotation) for various Different Conditions in Water Treatment)

  • 김미정;이병호
    • 상하수도학회지
    • /
    • 제11권4호
    • /
    • pp.118-125
    • /
    • 1997
  • Conventional sedimentation method has some limitations for turbidity removal in water treatment because drinking water sources are getting polluted. Removal rates of turbidity using DAF and sedimentation process were compared for various water conditions to know whether DAF is effective to improve sedimentation process. Water samples were clay(gravity 2.65) water 100mg/l, H raw water, mixed water of H raw water and clay 100mg/l, and mixed water of HA(Humic Acid) 5mg/l and clay 100mg/l. Other parameters were temperature, coagulants(Alum, $FeCl_3$), and treatment time. Water temperature greatly affected in removal rates of turbidity for sedimentation and DAF. Generally DAF was more effective in removal rates of turbidity than sedimentation at the same experimental condition. Removal rates of $UV_{254}$ were high to over 90%, and independent of temperature and coagulant.

  • PDF

ENHANCED REMOVAL OF RESIDUAL ALUMINUM AND TURBIDITY IN TREATED WATER USING POLYMERS

  • Kim, Seung-Hyun
    • Environmental Engineering Research
    • /
    • 제10권4호
    • /
    • pp.155-164
    • /
    • 2005
  • This study investigated the possibility of reducing the residual aluminum (Al) in the treated water using polymers. Two raw waters (lake and river water) and three kinds of polymers (coagulant, flocculant, and filtration aids) were used for this purpose. This study found that coagulation at the high dose did not necessarily lead to the high concentration of the residual Al in the treated water. The coagulation efficacy was found more important in determining the residual Al than the coagulant dose. The use of a polymer enhanced the removal of turbidity as well as the residual Al. The coagulant aid removed the dissolved Al as well as the particulate Al by helping the coagulation and the solid-liquid separation. The flocculant aid and the filtration aid preferentially removed the particulate Al while helping the solid-liquid separation. The filtration aid reduced the residual Al substantially more effectively than the flocculant aid. The polyamine-based coagulant aid (FL) showed the better performance in reducing the residual Al and turbidity than DADMAC (WT). The cationic flocculant aid with weak charge density and the medium molecular weight (SC-020) showed the best performance in reducing the residual Al.

전기응집-전기부상 2단계 공정을 이용한 TiO2 제거 (TiO2 Removal using Electrocoagulation-electroflotation Two-step Process )

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제32권5호
    • /
    • pp.385-394
    • /
    • 2023
  • There is a need for a method that can effectively remove wastewater containing small-sized particles such as TiO2. In this study, we attempted to remove TiO2 wastewater using electrocoagulation-electroflotation two-step separation. The TiO2 wastewater was effectively removed via batch electrocoagulation-electroflotation separation. However, in the batch process, the simultaneous operation of electrocoagulation and electoflotation was challenging due to the high residual turbidity. In the continuous operation, electrocoagulation and electoflotation reactors were kept separate. The turbidity removal in continuous operation was similar to that in the batch process, nevertheless, the residual Al concentration was high, leading to the conclusion that counterterm ensures against residual Al were necessary.

Biofilter pretreatment for the control of microfiltration membrane fouling

  • Park, Jae-Hyung;Satoshi Takizawa;Hiroyuki Katayama;Shinichiro Ohgaki
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2003년도 춘계 총회 및 학술발표회
    • /
    • pp.31-38
    • /
    • 2003
  • A pilot scale biofilter pretreatment-microfiltration system (BF-MF) was operated to investigate the effect of biofilter treatment in fouling reduction of microfiltration. Biofiltration was expected to reduce the membrane fouling by removal of turbidity and metal oxides. The hollow-fiber MF module with a nominal pore size of 0.1$\mu$m and a surface area of 8m$^2$ was submerged in a filtration tank and microfiltration was operated at a constant flux of 0.5 m/d. Biofiltration using polypropylene pellets was performed at a high filtration velocity of 320 m/d. Two experimental setups composed of MF and BF/MF, i.e., without and with biofilter pretreatment, were compared. Throughout the experimental period of 9 months, biofilter pretreatment was effective to reduce the membrane fouling, which was proved by the result of time variations of trans-membrane pressure and backwash conditions. The turbidity removal rate by biofiltration varied between 40% to 80% due to the periodic washing for biofilter contactor and raw water turbidity. In addition to turbidity, metals, especially Mn, Fe and Al were removed effectively with average removal rates of 89.2%, 67.8% and 64.9%, respectively. Further analysis of foulants on the used membranes revealed that turbidity and metal removal by biofiltration was the major effect of biofiltration pretreatment against microfiltration fouling.

  • PDF

소금 첨가량에 따른 닭 육수의 무기질 함량 특성 - 고압 가열 추출 방식 이용 - (The Mineral Contents of Chicken Stock according to Salt Contents - Using a High-Pressure Extraction Cooking -)

  • 김동석;김종석;최수근
    • 한국조리학회지
    • /
    • 제14권4호
    • /
    • pp.283-291
    • /
    • 2008
  • The present study is purposed to suggest accurate guidelines for developing standardized chicken meat stock containing salt, and to develop a product for mass production of uniform quality achieved by applying High Pressure Extraction Cooking(HPEC) using a high.pressure extractor. Through this study, we examined water contents, ash contents, salinity, turbidity and mineral contents of chicken meat stock according to the addition of salt. The ash contents increased with the increase of the addition of salt, but the water contents decreased with the increase of the addition of salt. Salinity increased with the increase of the addition of salt. Turbidity decreased with the increase of the addition of salt, and difference in turbidity according to the addition of salt was regular. Among mineral contents, Na showed the highest content, which was believed to be because of the addition of salt, and it was followed by K and P. The results of this study show that the mineral contents in the stock were different according to the addition of salt, but they were neither proportional to the addition of salt nor showed a regular pattern.

  • PDF

탁도에 의한 구리·알킬암모늄화합물계 목재방부제(ACQ)의 농도 예측 (Prediction of Alkaline Copper Quat (ACQ) Wood Preservative Concentration by Turbidity)

  • 이종신;김경태;최광식
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권5호
    • /
    • pp.743-749
    • /
    • 2016
  • 균일한 품질의 방부처리 목재 생산을 위해서는 방부약액의 농도관리가 필요하다. 아직까지 목재방부처리 현장에서 농도관리를 위하여 간편하게 방부약액의 농도를 측정할 수 있는 방법은 개발되어 있지 않다. 본 연구에서는 ACQ 목재방부제를 대상으로 비교적 손쉽게 측정할 수 있는 탁도를 이용하여 농도를 예측할 수 있는 방법을 검토하였다. 탁도가 현저하게 작은 알칼리성의 ACQ 약액에 20%의 인산 용액을 첨가하면 백색의 현탁 물질이 생성되며 탁도가 증가한다. 인산 용액의 최적 첨가량은 약액의 탁도가 최고치에 도달하는 pH 7 수준이며, 첨가량이 많아지면 약액의 산성화와 함께 탁도가 급격하게 떨어지고 약액은 투명해진다. ACQ 약액의 농도와 탁도 간에는 정(正)의 상관을 가지며 고도의 유의성이 인정되었다. 농도와 탁도로부터 유도된 회귀방정식을 사용하여 산출한 현장 채취 약액의 예측 농도 값과 적정법으로 측정한 실측 농도 값 간의 농도 차이에는 t 검정 결과, 유의성이 인정되지 않았다. 따라서 탁도와 회귀방정식을 이용하여 ACQ 현장 약액의 농도 관리가 가능할 것으로 예상된다.

팔당호에서 수중 탁도의 일 변동과 고탁수의 입자 분포 (Daily Variations of Water Turbidity and Particle Distribution of High Turbid-Water in Paltang Reservoir, Korea)

  • 신재기;강창근;황순진
    • 생태와환경
    • /
    • 제36권3호통권104호
    • /
    • pp.257-268
    • /
    • 2003
  • 하천형 저수지 (팔당호)에서 탁도의 변동과 탁수에 포함된 입자의 분포를 파악하기 위해 1999${\sim}$2001년동안 일 모니터링 하였다. 수중 탁도와 탁수의 입자 분포는 강우 패턴의 기후학적 요인과 유입${\cdot}$방류량의 수문학적요인 영향이 중요하게 작용하였다. 탁도의 연 평균 농도는 매년 비슷하였고, 연중 10 NTU 이하는 85.0%를 차지하였다. < 5 NTU는 겨울철${\sim}$봄철에, 5${\sim}$10 NTU범위는 가을철에, > 20 NTU이상은 여름철에 우점하는 계절적 특성이 뚜렷하였다. 탁도의 최대값은 7월 하순${\sim}$8월 초순에 발생하였고, 수문 변동과 달리 1999년에서 2001년으로 갈수록 증가하였다. 특히, 2001년에 저수지의 최대탁도는 하류로 갈수록 더욱 증가하는 양상이 현저하였다. 또한, 1999년에는 유량과 탁도가 완만하게 증감되었으나, 2000년과 2001년에는 초기에 급격하게 증가한 후 유량이 커지면서 감소하는 패턴을 보였다. 탁수의 입자는 전 정점에서 clay성분으로 갈수록 분포가 더욱 조밀하였을 뿐만 아니라 차지하는 비율도 높았다. 탁수에서clay는 63.9${\sim}$66.6%, silt는 33.4${\sim}$36.1% 범위로서 총 입자수의 98.9${\sim}$100%범위를 차지하였고, sand는 1.1%이내이었다. 하천형 저수지에서 수중 탁도는 비강우기에 플랑크톤의 생물량에 의한 영향을 많이 받으나 강우기에는 토양 성분을 근간으로 하는 무기입자의 양과 상대적 비율이 매우 우세한 것으로 평가되었다.

SWRO 전처리 공정에 적용된 DABF 내 Ball Media Filter 성능 평가 (Performance Evaluation of Ball Media Filter in DABF applied to SWRO pretreatment process)

  • 최석호;이정현;박성주;이영근;노형근;김용범
    • 한국물환경학회지
    • /
    • 제35권6호
    • /
    • pp.567-573
    • /
    • 2019
  • DABF(Dissolve Air Flotation with Ball Filter) is developed as the DAF with the addition of a fiber ball at the lower part of the DAF. The DABF with a capacity of 4,500 ㎥/h was constructed at Gijang SWRO plant in Busan. Since the ball filter has high filtration rate, the loading rate of DABF was designed from 20 to 42 ㎥/h/㎡. When one DABF basin is in the back washing mode, the loading rate of other two DABF basins is increased to 42 ㎥/h/㎡. Turbidity at the BF outlet in DABF is <2 NTU at turbidity of 5-10 NTU at the BF inlet. If there is no algae bloom and turbidity is low in raw seawater, only BF in DABF is operated and meets <2 NTU at the BF outlet. Even if BF is operated at high hydraulic loading rates, no significant differential pressure increases and reduction in the turbidity removal rate is minimal in a day. Thus, DABF is the pre-treatment technology that provides stable water quality even with BF onlyoperation without DAF operation. Compared with the DAF, DABF requires additional facilities such as valves, piping, and drainage systems for backwashing the BF. But in terms of footprint and operating costs, DABF has more advantages than DAF. With DABF application, the load of the downstream filtration equipment is decreased so that the capacity of the filtration equipment can be reduced. Also, if the downstream filtration equipment is to be maintained the same regardless of DABF, the operating cost of DABF is less than DAF.