• 제목/요약/키워드: High strength steel bar

검색결과 144건 처리시간 0.031초

Pilot Plant를 이용한 600 MPa급 내진용 철근들의 제조, 미세조직과 기계적 특성 비교 (Microstructure and Mechanical Properties of 600 MPa-Grade Seismic Resistant Reinforced Steel Bars Fabricated by a Pilot Plant)

  • 홍태운;황병철
    • 한국재료학회지
    • /
    • 제29권6호
    • /
    • pp.349-355
    • /
    • 2019
  • This study deals with the microstructure and tensile properties of 600 MPa-grade seismic reinforced steel bars fabricated by a pilot plant. The steel bar specimens are composed of a fully ferrite-pearlite structure because they were air-cooled after hot-rolling. The volume fraction and interlamellar spacing of the pearlite and the ferrite grain size decrease from the center region to the surface region because the surface region is more rapidly cooled than the center region. The A steel bar specimenwith a relatively high carbon content generally has a higher pearlite volume fraction and interlamellar spacing of pearlite and a finer ferrite grain size because increasing the carbon content promotes the formation of pearlite. As a result, the A steel bar specimen has a higher hardness than the B steel bar in all the regions. The hardness shows a tendency to decrease from the center region to the surface region due to the decreased pearlite volume fraction. On the other hand, the tensile-to-yield strength ratio and the tensile strength of the A steel bar specimen are higher than those of the B steel bar with a relatively low carbon content because a higher pearlite volume fraction enhances work hardening. In addition, the B steel bar specimen has higher uniform and total elongations because a lower pearlite volume fraction facilitates plastic deformation caused by dislocation slip.

중공형 GFRP리바의 기계적 특성에 관한 연구 (A Study on the Mechanical Characteristics of Ho1low Type Glass Fiber Reinforced Plastics Re-bar)

  • 한길영;이동기;오환교;홍석주;신용욱;배시연
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.7-11
    • /
    • 2000
  • In this paper was studied on the mechanical characteristics of Glass Fiber Reinforced Plastics(GFRP) of the steel bar it is to replace. The advantage of FRP such as high strength, low weight and chemical inertness or noncorrosiveness can be fully exploited. GFRP bar were successfully fabricated at l0mm nominal diameters of solid and hollow types using a pultrusion method. Tensile and bending specimens from this bar were tested and compared with behavior of GFRP rebar and steel bar.

  • PDF

강섬유보강 고강도 경량콘크리트의 부착에 관한 실험적 연구 (An Experimental Study on the Bond of Steel Fiber Reinforced High-Strength Lightweight Concrete)

  • 민준수;김상우;이시학;김용부
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.613-616
    • /
    • 1999
  • The bond between reinforcing bar and concrete is a significant factor to confirm that they behave uniformly in the reinforced concrete. Thus, the studies on this field have been conducted by many researchers. But for the high strength lightweight concrete few studies have been done. In this study, the steel fiber reinforced high strength lightweight concrete developed to complement the brittleness of the high strength lightweight concrete was studied experimentally to find the local bond stress. Total 20 specimens were tested and the measured test values were compared with those calculated according to ACI 318-95 code and CEB-FIP code, respectively. The results indicate that the maximum bond stress has been influenced by increment of volume fracture of steel fiber, compressive strength and cover, Especially steel fiber caused not only increment of bond strength but also ductile behaviro.

  • PDF

20db 정착길이를 가지는 SD700 갈고리철근과 확대머리철근의 정착성능 실험 (Anchorage performance tests of SD700 hooked bar and headed bar with a anchorage length of 20db)

  • 김호영;심혜정
    • 도시과학
    • /
    • 제7권2호
    • /
    • pp.21-27
    • /
    • 2018
  • With the increase of the skyscraper center, the development of large-diameter and high-strength reinforcing bars is being carried out to solve the dense reinforcement. In case of the steel reinforced concrete with a small cross section such as beam-column joints, the development length becomes short when straight bars are used. Therefore, it is possible to solve the problem that the development length becomes short by using the bearing strength of the hooked bar and headed bar. In this study, the exterior beam-column joint test of SD700 hooked bar and headed bar with anchorage length of 20db was conducted to extend the development length limitation of hooked bar and headed bar. As a result of the evaluation of the anchorage strength using the design equation by KCI, the average of the [measured value]/[predicted value] ratio was 1.31 for the hooked reinforcing bars. In the case of headed bars, the average of the [measured value]/[predicted value] ratio was 1.12. In addition, in order to compare the anchorage performance of the hooked bar and the headed bar, the measured values were divided by the square root of the compressive strength of the concrete to compare the anchorage strength. Under the same conditions, the anchorage strength of headed bars was 8.5% higher than the hooked bars.

고강도 콘크리트의 부착할렬기구에 관한 실험적 연구 (An Experimental Study on the Bond Split Mechanism of High Strength Concrete)

  • 장일영
    • 콘크리트학회논문집
    • /
    • 제11권4호
    • /
    • pp.129-136
    • /
    • 1999
  • For the prediction of concrete-steel bond ability in reinforced concrete, many countries establish specifications for the pullout test. But these methods hardly to consider many parameters such as strength, shape, diameter and location of steel, concrete restrict condition by loading plate, strength of concrete and cover depth etc, and it is difficult to solve concentration and disturbance of stress. The purpose of this study is to propose a New Ring Test method which can be rational quantity evaluations of bond splitting mechanism. For this purpose, pullout test was carried out to assess the effect of several variables on bond splitting properties between reinforcing bar and concrete. Key variables are concrete compressive strength, concrete cover, bar diameter and rib spacing. Failure mode was examined and maximum bond stress-slip relationships were presented to show the effect of above variables. As the result, it appropriately expressed general characteristics of bond splitting mechanism, and it proved capability for standard test method.

Local bond-slip behavior of medium and high strength fiber reinforced concrete after exposure to high temperatures

  • Tang, Chao-Wei
    • Structural Engineering and Mechanics
    • /
    • 제66권4호
    • /
    • pp.477-485
    • /
    • 2018
  • This study aims to investigate the influence of individual and hybrid fiber on the local bond-slip behavior of medium and high strength concrete after exposure to different high temperatures. Tests were conducted on local pullout specimens (150 mm cubes) with a reinforcing bar embedded in the center section. The embedment lengths in the pullout specimens were three times the bar diameter. The parameters investigated include concrete type (control group: ordinary concrete; experimental group: fiber concrete), concrete strength, fiber type and targeted temperature. The test results showed that the ultimate bond stress in the local bond stress versus slip curve of the high strength fiber reinforced concrete was higher than that of the medium strength fiber reinforced concrete. In addition, the use of hybrid combinations of steel fiber and polypropylene fiber can enhance the residual bond strength ratio of high strength concrete.

Reinforcing effect of CFRP bar on concrete splitting behavior of headed stud shear connectors

  • Huawen Ye;Wenchao Wang;Ao Huang;Zhengyuan Wang
    • Steel and Composite Structures
    • /
    • 제48권2호
    • /
    • pp.131-143
    • /
    • 2023
  • The CFRP bar was used to achieve more ductile and durable headed-stud shear connectors in composite components. Three series of push-out tests were firstly conducted, including specimens reinforced with pure steel fibers, steel and CFRP bars. The distributed stress was measured by the commercial PPP-BOTDA (Pre-Pump-Pulse Brillouin optical time domain analysis) optical fiber sensor with high spatial resolution. A series of numerical analyses using non-linear FE models were also made to study the shear force transfer mechanism and crack response based on the test results. Test results show that the CFRP bar increases the shear strength and stiffness of the large diameter headed-stud shear connection, and it has equivalent reinforcing effects on the stud shear capacity as the commonly used steel bar. The embedded CFRP bar can also largely improve the shear force transfer mechanism and decrease the tensile stress in the transverse direction. The parametric study shows that low content steel fibers could delay the crack initiation of slab around the large diameter stud, and the CFRP bar with normal elastic modulus and the standard reinforcement ratio has good resistance to splitting crack growth in headed stud shear connectors.

횡방향 판재에 의한 횡구속 효과 및 철근콘크리트 기둥에서 고강도 철근의 사용성 검토 (Confinement Effect by Plate Type Lateral Reinforcement and Investigation of the Possibility for Use of High Strength Steel Bars in Reinforced Concrete Columns)

  • 조영재;김진근
    • 콘크리트학회논문집
    • /
    • 제24권6호
    • /
    • pp.643-650
    • /
    • 2012
  • 콘크리트구조설계기준에서는 철근콘크리트 기둥에서 주철근의 설계기준항복강도를 550 MPa 이하로 규정하고 있다. 이는 철근콘크리트 기둥에 주철근으로 고강도 철근(high-strength concrete)을 사용할 때 콘크리트가 압축강도에 도달하여도 주철근이 항복변형률에 도달하지 않아 고강도 철근을 효율적으로 사용할 수 없기 때문이다. 철근의 설계기준항복강도 제한의 문제점을 해결하기 위한 방법으로는 횡구속력(confinement effect)을 가해주는 방법과 콘크리트의 파괴변형률(peak strain)을 증진시켜주는 방법이 있다. 횡구속을 효과적으로 가하는 방법으로서 원형 단면의 철근보다는 판재를 사용하는 것이 바람직하다. 이 연구에서는 가공이 용이한 판재로서 탄소섬유판을 철근콘크리트 기둥에서 횡구속효과를 위한 구조재료로 사용하였을 경우 보강되지 않은 경우보다 증진된 압축강도 및 축압축 파괴변형률을 보였으며, 콘크리트 단면 형상이 원형에 가까울수록, 횡구속 형태가 원형에 가까울수록 횡구속 효과는 더욱 커졌다. 최종적으로 실험 결과를 토대로 철근콘크리트 기둥에서 탄소섬유판에 의한 횡구속 효과와 함께 고강도 철근의 적용 가능성을 확인하였다.

고주파 표면경화된 중탄소강의 비틀림 피로강도에 미치는 초기조직의 영향 (Effect of Prior Structure on Torsional Fatigue Strength of Induction Surface Hardened Medium Carbon Steel)

  • 김흥집;정인상
    • 열처리공학회지
    • /
    • 제11권4호
    • /
    • pp.247-257
    • /
    • 1998
  • In order to evaluate the relation between prior structure and fatigue strength on a induction surface hardened medium carbon steel(SAE1050M) for automotive drive shafts, torsional fatigue test were conducted with various cases of different hardened depths and applied loads. Prior structures of the steel such as pearlite, fine pearlite and spheroidal pearlite were prepared by conventional nomalizing, tempering after quenching and spheroidized annealing, respectively. Maximum torsional fatigue strength can be obtained when the case depth is 18~25% diameter of the bar in each prior structure. The effect of case depth on the torsional fatigue strength was different depending on applied load to specimen, but the most good fatigue life was shown in the case of pearlitic structure when the case depth was 4.0~5.5mm(18~25% of bar diameter). Among three different prior structures, energy consumption, to obtain high strength or to get the same case depth, was the most saved in the case of pearlitic structure.

  • PDF

상·하부 ㄱ형강 반강접 CFT 기둥-보 접합부의 단조 및 이력거동 (Monotonic and Hysteresis Behavior of Semirigid CFT Column-to-Beam Connections with a Top-Seat Angle)

  • 이성주;김주우
    • 한국강구조학회 논문집
    • /
    • 제26권3호
    • /
    • pp.191-204
    • /
    • 2014
  • 본 논문에서는 반복하중을 받는 CFT 합성골조에서 부분강접 접합부인 상 하부 ㄱ형강 접합부의 휨모멘트 내력을 구하기 위하여 체계적인 수치해석이 수행되었다. 고강도강 연결봉으로 조립된 합성 부분강접 CFT 접합부의 회전강성, 휨모멘트 내력 및 파괴모드를 연구하기 위하여 3차원 비선형 유한요소 해석이 수행되었다. 부가적인 다양한 구조적 거동은 ㄱ형강의 두께 및 고강도 강봉 게이지 거리로 상 하부 ㄱ형강 접합의 파라미터에 대한 영향을 설명하고 있다. 해석모델의 적합성은 유한요소해석 결과로부터 얻은 모멘트-회전각 곡선을 Richard의 회귀분석을 통하여 비교 분석하였다.