• 제목/요약/키워드: High strength bar

검색결과 362건 처리시간 0.024초

높은 마디면적비 철근의 부착강도에 따른 정착설계 연구 (Study on the Development Design Criteria of High Relative Rib Area bars)

  • 박성규;홍건호;최완철;홍기섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.270-273
    • /
    • 2006
  • Bond between reinforcing bar and the surrounding concrete is made up of three components. There are chemical adesion, friction, and mechanical interaction between the rib of the bar and the surrounding concrete. bond of deformed bars depends primarily on the beraing of rib deformation anainst the surrounding concrete. The final objective of the study is to enhance structural stability, and workability thorough increasing the bond strength between deformed bar and surrounding concrete. The results of this study will be used to shorten bond and development length by $20{\sim}30$ percent and it will facilitate to use of high strength and high-relative rib area bars.

  • PDF

고강도 콘크리트와 GFRP 보강근을 사용한 보-기둥 접합부 휨 실험 (Flexural Test on Beam-Column Connections Using High Strength Concrete and GFRP bars)

  • 이혜진;김시준;양근혁;박상훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.177-178
    • /
    • 2017
  • The beam-column connection using high-strength GFRP bars exhibited a comparable flexural strength but brittle failure mode, when compared with those of connection using high-strength steel reinforcement.

  • PDF

고강도 콘크리트의 부착할렬기구에 관한 실험적 연구 (An Experimental Study on the Bond Split Mechanism of High Strength Concrete)

  • 장일영
    • 콘크리트학회논문집
    • /
    • 제11권4호
    • /
    • pp.129-136
    • /
    • 1999
  • For the prediction of concrete-steel bond ability in reinforced concrete, many countries establish specifications for the pullout test. But these methods hardly to consider many parameters such as strength, shape, diameter and location of steel, concrete restrict condition by loading plate, strength of concrete and cover depth etc, and it is difficult to solve concentration and disturbance of stress. The purpose of this study is to propose a New Ring Test method which can be rational quantity evaluations of bond splitting mechanism. For this purpose, pullout test was carried out to assess the effect of several variables on bond splitting properties between reinforcing bar and concrete. Key variables are concrete compressive strength, concrete cover, bar diameter and rib spacing. Failure mode was examined and maximum bond stress-slip relationships were presented to show the effect of above variables. As the result, it appropriately expressed general characteristics of bond splitting mechanism, and it proved capability for standard test method.

Effect of high temperature on the bond performance between steel bars and recycled aggregate concrete

  • Yan, Lan-Lan;Liang, Jiong-Feng;Zhao, Yan-gang
    • Computers and Concrete
    • /
    • 제23권3호
    • /
    • pp.155-160
    • /
    • 2019
  • The use of recycled aggregate concrete for the purpose of environmental and resource conservation has gained increasing interest in construction engineering. Nevertheless, few studies have reported on the bonding performance of the bars in recycled aggregate concrete after exposed to high temperatures. In this paper, 72 pull-out specimens and 36 cubic specimens with different recycled coarse aggregate content (i.e., 0%, 50%,100%) were cast to evaluate the bond behavior between recycled aggregate concrete and steel bar after various temperatures ($20^{\circ}C$, $200^{\circ}C$, $400^{\circ}C$, $600^{\circ}C$). The results show that the recycled aggregate concrete pull-out specimens exhibited similar bond stress-slip curves at both ambient and high temperature. The bond strength declined gradually with the increase of the temperature. On the basis of a regression analysis of the experimental data, a revised bond strength mode and peak slip ratios relationship model were proposed to predict the post-heating bond-slip behavior between recycled aggregate concrete and steel bar.

보 단부 부착시험체에 의한 높은마디 철근의 부착성능 (Evaluate Bond strength of high Relative Rib Area Bars Using Beam-end test specimens)

  • 서동민;양승열;홍기섭;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.112-115
    • /
    • 2004
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. However, the confinement force has a limitation. Thus, the only variable is the bearing angle corresponding to the change of bond force. Higher rib height bars possessing higher shearing resistance can maintain higher bearing angle and higher splitting resistance when bars are highly confined, and consequently higher bond strength, than lower rib higher bars. In this study, from the evaluate bond strength of high Relative Rib Area Bars Using beam-end test specimens are compared with the current provisions for development of reinforcement, and the improved design method of bond strength is proposed.

  • PDF

ACI 318-19 변경에 따른 확대머리철근 정착설계의 영향분석 (Study on the Effect on the Development Design of Headed Deformed Bars by change of ACI 318-19)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.110-111
    • /
    • 2019
  • In ACI 318-19 published recently, the conditions and development length equation to use the headed deformed bars were changed considerably. Although the use of the larger-diameter(No.14 and 18) headed deformed bars isn't yet permitted, the use of the high strength(80,000psi) headed deformed bars is permitted and the effect of bar-diameter($d_b$) on the development length is increased considerably. Therefore, structures using larger-diameter headed deformed bars will be expected to be affected by this code change. We will study the effect of the code change on the development design and find out the design optimization method to minimize the effect of the changed conditions and development length equation.

  • PDF

FRP Bar를 사용한 고강도 콘크리트 보의 콘크리트 전단강도 (Concrete Shear Strength of High Strength Concrete Beams Reinforced with FRP Bars)

  • 윤형수;장희석;김희성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.287-290
    • /
    • 2005
  • This study evaluates the concrete shear strength for normal and high strength concrete beams reinforced with 3 type FRP bars (CFRP, GFRP, HFRP). Experimental results obtained from twenty-four simply supported concrete beams are compared with values predicted by FRP shear strength expressions proposed in the various literatures, including the ACI Committee 318 and ACI Committee440. The shear strength correction factors are proposed through the regression analysis.

  • PDF

대구경/고강도 확대머리철근의 원전구조물 사용을 위한 코드개정방안 연구 (Code Change for Using Large-Sized/High-Strength Headed Deformed Bars in Nuclear Power Plant Structures)

  • 이병수;방창준;김석철;임상준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.80-81
    • /
    • 2014
  • Generally significant reinforcement is used for nuclear power plant structures and may cause potential problems when concrete is poured. In particular pouring concrete into structural member joint area is more difficult than other areas since the joint area is very congested due to hooked bars, embedded plates, and other reinforcements. The purpose of this study is to solve the problem by applying high-strength(ASTM A615 Gr. 75/80) bars. In addition large-sized(#14 & #18) headed deformed bar could be used as alternative of standard hooked bars to relieve the congestion to some extent. In order to apply headed deformed bars to nuclear power plant structures effectively, the large-sized diameter bars and the high-strength bars shall be used as thick as clear cover thickness 1". Therefore, test results were obtained by taking bar size, yield strength, and clear cover thickness as variables.

  • PDF

고장력 철근을 사용한 RC 보의 휨연성 평가 (Assessment of Flexural Ductility in RC Beams with High-Strength Reinforcement)

  • 권순범;윤영수;이만섭;임철현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.897-902
    • /
    • 2001
  • Recently, structure performance is maximized by using high strength concrete. In design of structure, concrete need combination with reinforcement, but use of common strength reinforcement make member complex bar placement, so high strength concrete members require increased strength reinforcement. If common strength reinforcement replaced by equal tension area of high strength reinforcement, reinforcement ratio increase and brittle failure of member may occur by material change. So, adequate upper limit of strength ratio is required to affirm ductile behavior in application of high strength reinforcement. In this study, ductility behavior was analysed by factor of reinforcement ratio, strength of concrete and reinforcement. The result indicate that ductile failure is shown under 0.35 $\rho_{b}$ in any reinforcement strength of same section and high strength concrete of 800kg/$cm^{2}$ used commonly is compatible with reinforcement of 5500kg/$cm^{2}$.

  • PDF

철골철근비에 따른 혼합구조보의 내력 및 변형 특성에 관한 연구 (A study on Properties of Strength and Deformation of Composite beams varying Ratio of Tensile bar to Steel)

  • 임병호;박정민;김화중
    • 한국강구조학회 논문집
    • /
    • 제14권1호
    • /
    • pp.87-94
    • /
    • 2002
  • 기존에 수행된 연구에서는 혼합구조보의 구조적 특성을 결정할 수 있는 제 영향인자 중에서 주근의 정착방법, 전단스팬비의 변화, 이질구조부의 보강 유무, 보강 방법의 변화 등에 따른 일련의 연구 성과들을 발표하였으며, 이러한 결과를 바탕으로 본 연구에서는 이질구조부에 대한 응력전달 및 내력상승 측면에서 철골단면적에 대한 인장철근비(철골철근비)를 변화시킨 단부 RC 중앙부 SC조 혼합보에 대해 RC부 주근의 정착방법(플랜지위 직접 용접, 스터드볼트 용접정착)에 따른 구조적 거동 특성을 고찰하였다. 그 결과 주근의 정착방법에 따른 구조적 특성은 거의 나타나지 않았으며, 철골철근비가 증가함에 따라 내력면에서는 효율성을 기대할 수 있으나, 연성능력이 저하될 수 있으므로 혼합구조보의 구조적 특성을 극대화시키기 위해서는 적정한 철골철근비로 제한하는 것이 필요한 것으로 나타났다.