• 제목/요약/키워드: High strength bar

검색결과 362건 처리시간 0.023초

Determination of spalling strength of rock by incident waveform

  • Tao, Ming;Zhao, Huatao;Li, Xibing;Ma, Jialu;Du, Kun;Xie, Xiaofeng
    • Geomechanics and Engineering
    • /
    • 제12권1호
    • /
    • pp.1-8
    • /
    • 2017
  • An experimental technique for determining the spalling strength of rock-like materials under a high strain rate is developed. It is observed that the spalling strength of a specimen can be determined by only knowing the wavelength, loading peak value and length of the first spallation of an incident wave under a specific loading waveform. Using this method in combination with a split-Hopkinson pressure bar (SHPB) and other experimental devices, the spalling strength of granite specimens under a high strain rate is tested. Comparisons with other experimental results show that the new measuring method can accurately calculate the dynamic tensile strength of rock materials under a high strain rate.

고강도 횡 보강근을 적용한 RC보의 정량적인 부착강도 평가 (Bond Capacity of U-shaped reinforcement for bond splitting prevention in RC beams)

  • 윤혜선;김영식;양완수;백승철;김길희
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.105-108
    • /
    • 2008
  • 국외적으로 고강도 재료에 대한 연구가 활발히 진행되고 있는 반면 국내에서는 고강도 재료에 대한 연구가 미비한 실정이다. 일반적으로 RC 보의 전단 저항은 보강근의 전단 저항 보강근의 양($p_w$), 항복 강도($f_{wy}$)에 지배적인 영향($p_wf_{wy}$)을 받는다. 따라서 고강도 전단 보강을 사용하는 것으로 전단 보강근의 양을 저감시키는 효과가 있을 것으로 판단된다. 이에 본 연구는 고강도 보강근과 보통 강도 비 폐쇄형 횡 보강근의 혼용을 통한 전단 보강근의 양을 줄여 시공 능률향상과 부착성능 향상을 유도하여 부재내력을 증진하기 위한 실험적 연구를 수행하였다.

  • PDF

고강도 철근용 충전형 기계적 이음장치 개발 연구 (Development of Filler Type Mechanical Splice for High Strength Re-bar)

  • 이성수;전호민
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.686-693
    • /
    • 2018
  • 철근 콘크리트 구조물에 다양한 종류의 철근 이음 방법이 개발되고 이를 현장에서 적용하여 왔다. 지난 여러 연구들에 따르면 철근의 직경이 굵어지고 철근의 강도가 커질 경우, 원가 효율 면에서 기계적 이음이 겹침이음보다 상대적으로 우수한 것으로 나타났다. 본 연구에서는 철근 콘크리트 구조물의 고강도 철근(SD600)에 대한 에폭시 충전형 기계적 이음장치를 제시하고 실험을 실시하였다. 이형 철근을 원형 튜브형 강재로 된 커플러에 삽입하고 고강도 에폭시 충전재를 커플러 안으로 주입하면 커플러 안에서 충전재가 경화되면서 이음 장치가 구성된다. 에폭시의 압축강도, 커플러의 길이, 철근의 지름 등에 따른 에폭시 충전형 기계적 이음장치에 대한 일방향 인장시험을 수행하였으며, 실험체의 파괴하중 및 파괴 양상을 관찰하였다. 실험 결과, 실험체의 실제 파괴하중은 에폭시 충전재의 예상 파단 내력의 약 2배 이상으로 나타나 강재 커플러의 구속으로 인하여 경화 에폭시 충전재의 파괴하중이 크게 증가했다는 것을 확인하였다.

Elucidating the mechanical behavior of ultra-high-strength concrete under repeated impact loading

  • Tai, Yuh-Shiou;Wang, Iau-Teh
    • Structural Engineering and Mechanics
    • /
    • 제37권1호
    • /
    • pp.1-15
    • /
    • 2011
  • The response of concrete to transient dynamic loading has received extensive attention for both civil and military applications. Accordingly, thoroughly understanding the response and failure modes of concrete subjected to impact or explosive loading is vital to the protection provided by fortifications. Reactive powder concrete (RPC), as developed by Richard and Cheyrezy (1995) in recent years, is a unique mixture that is cured such that it has an ultra-high compressive strength. In this work, the concrete cylinders with different steel fiber volume fractions were subjected to repeated impact loading by a split Hopkinson Pressure Bar (SHPB) device. Experimental results indicate that the ability of repeated impact resistance of ultra-high-strength concrete was markedly superior to that of other specimens. Additionally, the rate of damage was decelerated and the energy absorption of ultra-high-strength concrete improved as the steel fiber volume fraction increased.

고강도 강봉을 이용한 철근 콘크리트 보의 보강에 관한 연구 (Rehabilitation of RC Beams with High Tension Steel Bars)

  • 양재연;박순규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.438-441
    • /
    • 2004
  • This paper presents the results of the experimental study on the performances of reinforced concrete beams rehabilitated by external unbonded high tension steel-bar. Design variables for the experiment in this study includes the position of anchorage zone of the high tension steel bar, the anchorage length of the reinforcing steel bar and the types of the shear strengthening measures. 5 specimens were tested with one point monotonically increased loads and structural performances such as strength capacities, ductility capacities and failure modes were analysed. It is found that the structural performance of the rehabilitated beams are strongly depended on the location of anchorage zone of the high tension steel-bars. In the case that anchorage zone is located near the critical shear zone, it is observed that the rehabilitated beam is failed in brittle failure mode and the additional shear strengthening is necessitated. But if anchorage zone is properly located or additional shear strengthening device is provided properly, it is also observed that the strength capacity of the rehabilitated beams could be increased more than $200\%$ by the proposed method.

  • PDF

간이 내화시험에 의한 석고계 모르타르의 내화성능 (Fireproof Performance of Mortar using Gypsum in Simplified Heating Test)

  • 강석표
    • 한국건축시공학회지
    • /
    • 제11권2호
    • /
    • pp.181-188
    • /
    • 2011
  • 고강도콘크리트 부재 표면에 내화모르타르를 피복하여 화재시 콘크리트 표층부의 온도상승을 저감시킴으로서 내부 철근온도 상승을 억제한다. 본 논문은 간이내화시험을 통하여 시멘트 및 석고계 내화모르타르 피복 고강도콘크리트의 내부철근 온도상승을 검토하기 위한 것이다. 그 결과 석고계 내화모르타르가 시멘트계 내화모르타르보다 고강도콘크리트의 내부철근 온도상승을 저감시키는데 효과적인 것으로 나타났으며 내화모르타르 피복두께가 작을수록 시멘트계 내화모르타르와의 내부 철근 온도차이가 증가하였다. 또한 ${\alpha}$형 반수석고와 ${\beta}$형 반수석고 종류에 따른 내화모르타르의 온도상승 저감효과의 차이는 없는 것으로 나타났지만, ${\alpha}$형 반수석고 내화모르타르의 압축강도가 ${\beta}$형 반수석고 내화모르타르보다 높게 나타났다.

반복하중이 작용하는 고강도 모르타르 충전식 슬리브 철근이음에 대한 강성 평가 (Evaluation on Stiffness of High-strength Mortar-filled Sleeve Bar Splice Under Cyclic Loading)

  • 김형기;정구용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.85-93
    • /
    • 2013
  • 본 논문에서는 반복하중이 작용하는 고강도 모르타르 충전식 슬리브 철근이음의 강성에 대한 합리적인 검토를 하기 위하여 100여개 고강도 모르타르 충전식 슬리브 철근이음의 실험데이터를 이용하여 슬리브 철근이음이 보유하고 있는 구조인자가 반복 하중이 작용하는 슬리브 철근이음의 강성에 미치는 효과를 파악하였고, AIJ 규준에 정해져 있는 강성 등급을 충족시키는 최소한 의 조건에 대하여 평가한 결과, SD350과 SD400 철근을 매입한 모르타르 충전식 주물 슬리브 철근이음에서 $f_{g^*}$(L/d)가 470MPa 이상이 된다면 AIJ 규준의 SA급 강성, $f_{g^*}$(L/d)가 340MPa 이상이 된다면 AIJ 규준의 A급 강성을 최종파괴형식과 슬리브 형상에 상관없이 확보할 수 있는 것으로 나타났다. 또한 SD500 철근을 매입한 모르타르 충전식 슬리브 철근이음에서 주물슬리브와 강관 슬리브를 사용한 경우는 $f_{g^*}$(L/d)가 400MPa 이상이 된다면 AIJ 규준의 A급 강성을 확보할 수 있는 것으로 나타났다.

SD500 고강도 철근용 커플러이음의 경제성 평가에 관한 연구 (A Study on Economic Evaluation Method of Coupler Splice for High Strength(SD500) Reinforcement)

  • 김재엽;김광희
    • 한국건설관리학회논문집
    • /
    • 제8권2호
    • /
    • pp.136-145
    • /
    • 2007
  • 우리나라의 초고층 건축물은 초고층아파트가 대도시 주거건축의 대표적인 유형으로 등장하면서 점차 증가하고 있다. 최근 건축되고 있는 이러한 초고층 건축물에서는 건물의 안정성과 내구성 등을 감안하여 사용재료의 강도도 점차 증가하고 있다. 이에 따라 철근의 경우 SD500철근을 사용하는 공사현장을 쉽게 볼 수 있게 되었다. 이에 본 연구에서는 국내의 건축공사에서 사용되는 SD500철근의 사용 실태를 분석하였다. 또한 SD500철근의 이음방법으로 많이 사용되고 있는 겹침이음과 커플러이음에 대한 경제성 평가방법을 제안하고, 이를 2006년 12월 서울을 기준으로 평가하였다. 경제성 평가 결과, 커플러 이음은 철근직경이 클수록 콘크리트의 강도가 낮을수록 겹침이음에 비해 공사비용 측면에서 상대적으로 유리한 것으로 분석되었다.

고장력 인장봉으로 보강된 RC 보의 휨 거동에 관한 실험적 연구(3) (An Experimental Study on Flexural Behavior of RC Beams Strengthened with Hi-Strength Bars(3))

  • 신경재;김윤정;문정호
    • 콘크리트학회논문집
    • /
    • 제19권3호
    • /
    • pp.351-358
    • /
    • 2007
  • 현재 상용되고 있는 강판 보강법이나 탄소섬유 시트 부착 보강법과는 달리, 고장력 인장봉을 이용한 외부 비부착 방식의 보강법은 설치가 간단하고 시공 시간이 짧은 등의 장점이 있다. 또한 외부 비부착 보강법은 콘크리트 표면처리가 필요 없고 에폭시 등의 접착제를 사용하지 않아 환경에 미치는 영향도 적다. 지난 연구에 이어 본 연구에서는 보강된 RC보에 관한 총 9개의 실대형 시험체를 변수별로 제작하여 여러 변수가 실제 구조물에 미치는 영향을 검토하였다. 시험체의 주요 변수는 보강재의 크기와 전단 보강근의 간격, 지지 조건이다. 본 논문에서는 보강된 RC 보의 구조적 거동을 무보강 시험체와 비교하여 기술하였다. 실험 결과 고장력 인장봉으로 보강된 RC보는 무보강 시험체와 비교하여 강도와 휨 성능에서 탁월한 효과를 나타내었으며 전단 보강근이 과소 배근된 시험체에서도 고장력 인장봉에 의한 전단 내력 효과를 보였다.

SFRC 부재에 수직 배근된 고강도 확대머리철근의 정착강도 (Anchorage Strength of High Strength Headed Bar Embedded Vertically on SFRC Members)

  • 이창용;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.148-156
    • /
    • 2020
  • 본 논문은 강섬유 보강 콘크리트 부재에 수직으로 기계적 정착된 고강도 확대머리철근의 정착성능을 평가하기 위하여 실시한 기초 인발실험결과를 정리한 것이다. 주요 실험변수는 강섬유의 혼입률, 콘크리트 강도, 정착길이, 확대머리철근 항복강도, 전단보강유무 등이다. 실험체의 좌우 순피복두께는 확대머리철근 직경의 두 배로 계획하였다. 확대머리철근을 중심으로 1.5𝑙dt, 0.7𝑙dt가 되는 위치에 힌지 지점을 두고, 확대머리 철근을 직접 인발하였다. 인발실험결과, 실험변수에 따라 콘크리트 파괴 및 철근 인장파단이 나타났다. 강섬유를 보강한 실험체가 동일한 변수의 강섬유를 보강하지 않은 실험체에 비히여 콘크리트 압축강도는 2.7~5.4% 크게 나타난 반면 인발강도는 20.9~63.1% 크게 나타나 정착성능 향상에 큰 기여를 하는 것으로 평가되었다. 강섬유 보강 콘크리트에 대해 확대머리철근과 평행한 전단보강근의 배근은 1.7~7.7% 인발강도를 증가시켰으나, 콘크리트 강도 증가를 고려할 때 정착성능 향상에 미치는 영향이 크지 않았다. 본 실험체 상세와 같이 강섬유보강 콘크리트 부재에 수직정착된 SD600의 확대머리철근 정착설계는 KCI2017, KCI2012의 정착길이 설계식을 그대로 사용할 수 있을 것으로 사료된다.