• Title/Summary/Keyword: High repetition rate

Search Result 203, Processing Time 0.024 seconds

Initial Dosimetry of a Prototype Ultra-High Dose Rate Electron-Beam Irradiator for FLASH RT Preclinical Studies

  • Hyun Kim;Heuijin Lim;Sang Koo Kang;Sang Jin Lee;Tae Woo Kang;Seung Wook Kim;Wung-Hoa Park;Manwoo Lee;Kyoung Won Jang;Dong Hyeok Jeong
    • Progress in Medical Physics
    • /
    • v.34 no.3
    • /
    • pp.33-39
    • /
    • 2023
  • Purpose: FLASH radiotherapy (RT) using ultra-high dose rate (>40 Gy/s) radiation is being studied worldwide. However, experimental studies such as preclinical studies using small animals are difficult to perform due to the limited availability of irradiation devices and methods for generating a FLASH beam. In this paper, we report the initial dosimetry results of a prototype electron linear accelerator (LINAC)-based irradiation system to perform ultra-high dose rate (UHDR) preclinical experiments. Methods: The present study used the prototype electron LINAC developed by the Research Center of Dongnam Institute of Radiological and Medical Sciences (DIRAMS) in Korea. We investigated the beam current dependence of the depth dose to determine the optimal beam current for preclinical experiments. The dose rate in the UHDR region was measured by film dosimetry. Results: Depth dose measurements showed that the optimal beam current for preclinical experiments was approximately 33 mA, corresponding to a mean energy of 4.4 MeV. Additionally, the average dose rates of 80.4 Gy/s and 162.0 Gy/s at a source-to-phantom surface distance of 30 cm were obtained at pulse repetition frequencies of 100 Hz and 200 Hz, respectively. The dose per pulse and instantaneous dose rate were estimated to be approximately 0.80 Gy and 3.8×105 Gy/s, respectively. Conclusions: Film dosimetry verified the appropriate dose rates to perform FLASH RT preclinical studies using the developed electron-beam irradiator. However, further research on the development of innovative beam monitoring systems and stabilization of the accelerator beam is required.

A study on the development and performance evaluation of reflective type Heart rate measurement system for PAPS (PAPS를 위한 반사형 맥파 측정 장치의 개발 및 성능 평가)

  • Kim, Sheen-Ja;Lee, Young-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.1
    • /
    • pp.160-166
    • /
    • 2012
  • We performed the development and performance evaluation of reflective type heart rate measurement system for PAPS. We used chip LED and chip photo TR. for low power driving. The measured PPG signal is preprocessed using high pass filter and low pass filter, and the preprocessed signal is displayed by LabVIEW. Also LabVIEW include the algorithm that extract effective signal and calculate the heart rate. We made sure that it will be able to apply to measurement equipment with high accuracy and repetition from exercising subject using this system and algorithm.

A Study on the Micro Machining in Polyurethane by Excimer Laser (엣시머 레이져를 이용한 폴리우레탄의 미세 가공에 관한 연구)

  • 김재구;이성국;윤경구
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.366-370
    • /
    • 1997
  • This paper descibes a micro groove machining process on the polyurethane biopolymer by KrF excimer laser. To investigate the etch charcteristics of polyurethane biopolymer quantitatively,laser system for ablation was installed with high precison moter and then polymer ablation experiment, in which paramteters were fluence,pulse repetition rate,numbers of pulses and assist gas, was carred out. In this experiment, we found out that the value of critical energy density for ablation is 30mJ/cmsup2/ and the etching rate is more dependent on the pulse number and fluence than any other pamameter. Finally, we machined micro grooves for fiexibility as width 300.mu.m depth 100.mu.m and port for micro-devices mounting as length 100.mu.m width 300.mu.m depth .mu.m on the outer wallof polyurethane biopolymer tube which is used as medical device.

  • PDF

Comparative study of OFDMA cooperative relaying methods in Rayleigh fading channel (레일레이 퍼이딩 채널에서 OFDMA 협동 릴레이 방식에 따른 성능비교)

  • Kim, Nam-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.3
    • /
    • pp.109-115
    • /
    • 2009
  • Recently, the relay communication is focused for the power saving and coverage extension of ad-hoc networks. For the high date rate transmission, it is proposed to adapt OFDMA relays. In this paper, we assume the 2 hop cooperative OFDMA relays between the source and the destination. The performance of 3 different relaying methods are derived and compared. We noticed that the selective OFDMA relaying method has the best performance followed by opportunistic OFDMA relaying and repetition-based OFDMA relaying method under the same threshold mutual information rate.

  • PDF

The Digital Controlled Implementation of the Resonant DC-DC Converter with High Voltage, High Frequency For Pulsed Nd:YAG Laser (고전압과 고주파수형 공진형 DC-DC 콘버터를 이용한 펄스형 Nd:YAG 레이저의 디지틸제어 구현)

  • Kim, Whi-Young
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.777-783
    • /
    • 2001
  • This paper is mainly concerned with the state of the practical developments of a constants PWM bridge type resonants DC-DC suitable converter for Nd:YAG Laser with a Microprocessor. (PIC16C54 & 8051) The use of IGBT power supply with feedback control of flashLamp currents imparts a advantages to Nd:YAG Laser for materials processing. these include the alility to tailor the pulseshape and modify pulse parameters on a pulse- by pulse basis. And Correct choice of pulseshape can enhance the repeatability of the process. as higher power IGBT became available, act ive pulseforming power supplies will find greater user in deep hole drilling machine By Using certain control tecniques, utililized in designing Pic16c54 from Microchip technology and Intel 8051, also Mornitoring from Microsoft Visual Basic 5, And it allowed us to designed and fabricate ahigh repel it ion rate and high power(HRHP) pulsed Nd:YAG laser system, As a result of that, the current pulsewidth could be contort led 200s to 350s(step 50s) , and the pulse repetition rate could be adjusted 500pps to 1150pps. In addition, in the case of one laser head consisting of a Nd:YAG laser rod and two flashlamps , the maximum laser output of 240w was produced at the condition of 350s and 1150pps, and that of about 480w was generated at the same condition when two laser heads were arranged in cascade.

  • PDF

Development of RSOD using optical phase modulator (광위상 변조기를 이용한 RSOD 개발)

  • Hwang, Dae-Seok;Lee, Young-Woo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.14-18
    • /
    • 2006
  • Optical interferometer is used for various optical measurement fields in optical metrology and biomedical measurements. In an optical interferometer, optical delay line has to change the optical path length of a reference arm to match with that of a sample in and it's speed was limited by reference arm movement speed. In this paper, we proposed an all-fibered RSODRapid Scanning-speed Optical Delay) without any mechanical movement, and we applied this system to optical interferometer. Experimental setup is consist of pulse laser source (center wavelength 1304nm, pulse width 30ps, repetition rate 10GHz), two phase modulators and dispersive shifted fiber. As experimental results, we obtain the maximum time delay of 11ps at 10MHz repetition rate, and it is easily tuneable the time delay by modulation frequency and modulation voltage.

A Simple Metric for Assessing the Severity of Partial Discharge Activity Based on Time-Sequence-Analysis-Discharge Level Patterns

  • Stewart Brian G;Yang Lily;Judd Martin D;Reid Alistair;Fouracre Richard A
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.313-318
    • /
    • 2006
  • This paper introduces a partial discharge (PD) severity metric, S, based on the evaluation of time-sequence PD data capture and resulting Time-Sequence-Analysis Discharge (TSAD) level distributions. Basically based on an IEC60270 measurement technique, each PD event is time stamped and the discharge level noted. By evaluating the time differences between a previous and subsequent discharge, a 3D plot of time-sequence activity and discharge levels can be produced. From these parameters a measurement of severity, which takes into account dynamic or instantaneous variations in both the time of occurrence and the level of discharge, rather than using standard repetition rate techniques, can be formulated. The idea is to provide a measure of the severity of PD activity for potentially measuring the state of insulation within an item of plant. This severity measure is evaluated for a simple point-plane geometry in $SF_{6}$ as a function of gap distance and applied high voltage. The results show that as the partial discharge activity increases, the severity measure also increases. The importance of future investigations, quantifications and evaluations of the robustness, sensitivity and importance of such a severity measurement, as well as comparing it with typical repetition rate assessment techniques, and other monitoring techniques, are also very briefly discussed.

A Developement of Ultra High Pressure Injection Equipment for Study on Diesel Spray Characteristics with Ultra High Pressure (극초고압 디젤분무특성 해석을 위한 극초고압 단발분사장치의 개발)

  • 정대용;이종태
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.5
    • /
    • pp.50-59
    • /
    • 2003
  • It was known that high pressure injection is an effective method to enhance thermal efficiency and decrease exhaust emissions in diesel engines. If injection pressure becomes ultra high, it is predicted that there may be a suitable injection pressure which the enhancement rate of spray characteristics is moderate. Also, there may be a limit injection pressure which spray characteristics is reversed and get worse. But these are unknown. To investigate a suitable injection pressure and a limit injection pressure, ultra high pressure injection equipment(UHPIE), which can realize the injection pressure of 3,200bar, was developed. UHPIE is a basic apparatus of single shot injection, and ultra high pressure was achieved by second stage rapid compression in short time. From the evaluation of UHPIE, a injection curve like a conventional diesel engine(jerk type) was realized. Also, it was proved that repetition of experiment was excellent. Therefore it was found that there was no problem to perform the study on the ultra high pressure injection with UHPIE. Consequently, the foundation of the study on ultra high pressure injection could be established.

3D Packaging Technology Using Femto Laser (팸토초 레이저를 이용한 3차원 패키징 기술)

  • Kim, Ju-Seok;Sin, Yeong-Ui;Kim, Jong-Min;Han, Seong-Won
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.190-192
    • /
    • 2006
  • The 3-dimensional(3D) chip stacking technology is one of the leading technologies to realize a high density and high performance system in package(SIP). It could be found that it is the advanced process of through-hole via formation with the minimum damaged on the Si-wafer. Laser ablation is very effective method to penetrate through hole on the Si-wafer because it has the advantage that formed under $100{\mu}m$ diameter through-hole via without using a mask. In this paper, we studied the optimum method for a formation of through-hole via using femto-second laser heat sources. Furthermore, the processing parameters of the specimens were several conditions such as power of output, pulse repetition rate as well as irradiation method and time. And also the through-hole via form could be investigated and analyzed by microscope and analyzer.

  • PDF

Characteristics of high-efficiency rust removal by adjusting variable frequency and voltage charging using the Pulsed Power system (펄스파워를 이용한 펄스반복율에 변화에 의한 고효율 RUST(녹) 제거 특성에 관한 연구)

  • Song, Woo-Jung;Kim, Su-Weon;Jeon, Jin-An;Joung, Jong-Han;Kim, Hwi-Young;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1800-1803
    • /
    • 2002
  • The pulsed power system was widely making use good of many industrial and environments. The pulse generator generally required for short pulse duration and high peak value was forced to consider its volume and economy. In this paper, this system is designed and fabricated which has a compact size of pulse generator with switched MOSFET. We have studied the removal of rust material using Arc discharging in pulsed power system. It have tested their characteristics by adjusting variable voltage charging and pulse repetition rate. As a result, We can eliminate rust materials with this device.

  • PDF