• 제목/요약/키워드: High power testing

검색결과 548건 처리시간 0.028초

단락시험용 대전류변압기 돌입전류특성에 관한 연구 (THE STUDY 01 CHARACTERISTICS OF INRUSH CURRENTS FOR HIGH POWER SHORT-CIRCUIT TESTING TRANSFORMER)

  • 노창일;나대열;김선구;정흥수;김원만;이동준;김선호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.695-696
    • /
    • 2006
  • The inrush current of transformer cause saturation effects of recovery voltage for short-circuit power testing. the inrush current depends on the residual flux of the transformer core. when inrush current occurs, it is contains a d.c. component and the high harmonic content of the current are of importance to relay protection of testing circuit. this paper describes of decrease method of inrush current for high power short-circuit testing transformer.

  • PDF

발전소 터빈베어링 예비품 보관방법 개선 (The Improvement of Storage Method for Spare Part of Turbine Bearing in Power Plants)

  • 이성호
    • 비파괴검사학회지
    • /
    • 제12권2호
    • /
    • pp.30-35
    • /
    • 1992
  • High quality of turbine babbit bearing has to be maintained for smooth operation of power plants. So in the research center of the Korea Electric Power Company, Ultrasonic testing has been peformed on the spare part of babbit bearing during past ten years. Since separation between babbit bearing and base metal was seen for most of the bearings in stock, investigation has begun in order to see the effect on temperature and humidity variation of the separation, and thus searching for the optimum storage method.

  • PDF

A Study on the Pattern Recognition Rate of Partial Discharge in GIS using an Artificial Neural Network

  • Kang Yoon-Sik;Lee Chang-Joon;Kang Won-Jong;Lee Hee-Cheol;Park Jong-Wha
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권2호
    • /
    • pp.63-66
    • /
    • 2005
  • This paper describes analysis and pattern recognition techniques for Partial Discharge(PD) signals in Gas Insulated Switchgears (GIS). Detection of PD signals is one of the most important factors in the predictive maintenance of GIS. One of the methods of detection is electro magnetic wave detection within the Ultra High Frequency (UHF) band (300MHz $\~$ 3GHz). In this paper, PD activity simulation is generated using three types of artificial defects, which were detected by a UHF PD sensor installed in the GIS. The detected PD signals were performed on three-dimensional phi-q-n analysis. Finally, parameters were calculated and an Artificial Neural Network (ANN) was applied for PD pattern recognition. As a result, it was possible to discriminate and classify the defects.

고압 차단기 동작특성 측정 및 분석용 시스템 개발 (The system development for measuring and analyzing operating characteristics of high-voltage circuit-breaker)

  • 윤지호;강윤식;김홍룡;박종화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.77-78
    • /
    • 2007
  • 국제규격에 따라 VCB(vacuum circuit breaker), ACB(air circuit breaker), 등과 같은 전력기기들의 기계적 동작 시험 시, 시험전후의 개폐시간, 개폐속도, 동작코일전류크기, 등과 같은 특성을 측정하고 이들의 변화정도를 평가하여 시험결과를 판단한다. 그러나 시험 중에는 이러한 동작특성들을 측정하지 않기 때문에, 시험 중에 실패하는 경우, 원인 규명에 많은 어려움이 따른다. 이러한 문제를 해결하기 위해, LS산전 PT&T(Power Testing & Technology Institutes)는 시험전후뿐만 아니라 전체시험횟수 동안 동작특성을 측정하고, 이들의 변화추이를 분석할 수 있는 시스템을 구축하고, 관련 소프트웨어를 개발하였다. 본 논문에서는 개발 내용과 결과를 소개하고자 한다.

  • PDF

스위칭방식 PV Simulator의 전력회로와 LCL필터 설계 (A Design of Power Circuit and LCL Filter for Switching Mode PV Simulator)

  • 이성민;유태식;김효성
    • 전력전자학회논문지
    • /
    • 제17권5호
    • /
    • pp.431-437
    • /
    • 2012
  • PV simulators are essential equipment for testing power conditioning systems (PCS) which are one of an important part in PV generator systems, for testing before shipment. High dynamic PV simulator is required since MPPT(Maximum Power Point Tracking) test procedure has been established by EN50530 regulation recently. Most high quality PV simulator prevailed in the market is linear type which however has low efficiency. This paper proposes design guide lines for the power stage and LCL type filter cooperating with a switching mode PV simulator that shows high efficiency and very low power consumption. Proposed theory is verified by experiment.

3MW 풍력발전시스템 출력성능평가에 관한 연구 (The Power Performance Testing for 3MW Wind turbine System)

  • 고석환;장문석;박종포;이윤섭
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.19-26
    • /
    • 2011
  • We are carried out power performance testing for 3MW wind turbine system at Je-ju wind turbine testing Site and analyzed measured data which was stored through monitoring system. In this paper, we described the power performance testing results and analyzed an uncertainty of measured data sets. The power curve with measured power data is closely coincide with designed power curve except for the low wind speed sections(4m/s~7m/s) and the annual energy production which is given Ray leigh distribution was included with 1.5~5.9% of uncertainty in the wind speed region as 4~11m/s. Although the deviation of curve between measured power and designed power is high, the difference of annual energy production is low in the low wind speed region.

Efficient Test Data Compression and Low Power Scan Testing in SoCs

  • Jung, Jun-Mo;Chong, Jong-Wha
    • ETRI Journal
    • /
    • 제25권5호
    • /
    • pp.321-327
    • /
    • 2003
  • Testing time and power consumption during the testing of SoCs are becoming increasingly important with an increasing volume of test data in intellectual property cores in SoCs. This paper presents a new algorithm to reduce the scan-in power and test data volume using a modified scan latch reordering algorithm. We apply a scan latch reordering technique to minimize the column hamming distance in scan vectors. During scan latch reordering, the don't-care inputs in the scan vectors are assigned for low power and high compression. Experimental results for ISCAS 89 benchmark circuits show that reduced test data and low power scan testing can be achieved in all cases.

  • PDF

고 출력 백색 변환용 LED(3W용)의 고장메커니즘 비교 (A Comparison of the Failure Mechanism for High Power Converted White LEDs(3W))

  • 윤양기;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제12권3호
    • /
    • pp.177-186
    • /
    • 2012
  • This paper presents a comparison of the failure mechanism for high power converted white LEDs(3W) with the commercially available YAG:Ce and silicate phosphor. We carry out the normal aging life test for 10,000 hours, the high temperature aging test for 8,000 hours, the high temperature and humidity aging test for 8,000 hours and the current aging testing for 5,000 hours. The optical and electrical parameters of LEDs were monitored, such as lumen, correlated color temperature (CCT), chromaticity coordinates(x, y), thermal resistance, I -V curve and spectrum intensity. The stress induced a luminous flux decay on LED in all experiments and causes a failure. So we try to find out what's a main failure mechanism for a high power LED.

Development of Airborne High Density High Voltage Power Supply for Traveling Wave Tubes

  • Park Young-Ju
    • Journal of Power Electronics
    • /
    • 제5권4호
    • /
    • pp.257-263
    • /
    • 2005
  • This paper describes the development and testing results of a high density High Voltage Power Supply (HVPS) that drives microwave Traveling Wave Tubes (TWTs) of phased array transmitters for airborne EW systems. The HVPS is designed to consist of a number of modules connected in series. Among them, especially, the high-density pulse transformer module including the resonant circuit is newly designed to make the HVPS much more reliable. In addition, this paper describes the development of high voltage solid-state modulation using fast switching devices (FETs) and also represents the test results of a modulator module.

금속 자기기억법 활용 보일러 튜브의 미소 결함 검출력 연구 (Study of Boiler Tube Micro Crack Detection Ability by Metal Magnetic Memory)

  • 서정석;명주홍;방지예;정계조
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.93-96
    • /
    • 2022
  • The boiler tubes of thermal power plants are exposed to harsh environment of high temperature and high pressure, and the deterioration state of materials rapidly increases. In particular, parent material and welds of the materials used are subjected to a temperature change and various constraints, resulting in deformation and its growth, resulting in frequent leakage accidents caused by tube failure. The power plant checks the integrity of boiler tubes through non-destructive testing as it may act as huge costs loss and limitation of power supply during power station shutdown period due to boiler tube leakage. However, the current non-destructive testing is extremely limited in the field to detect micro cracks. In this study, the ability of metal magnetic memory technique to detect flaws of size that are difficult to inspect by the visual or general non-destructive methods was verified in the early stage of their occurrence.