• 제목/요약/키워드: High permeability

검색결과 1,383건 처리시간 0.025초

고강도 콘크리트의 염화물 침투특성 (Chloride Permeability of High Strength Concrete)

  • 정해문;유환구;안태송
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.985-990
    • /
    • 2001
  • Chloride permeability of high strength concrete(HSC) was investigated using saltwater pending test and rapid chloride permeability test by electrical potential(ASTM C 1202). The lower water-cement ratio concrete showed the lower diffusion coefficient of chloride. The relationship between the diffusion coefficient of chloride and charge passed by the rapid chloride permeability test could be obtained. This relationship appears to be an effective method for evaluating chloride permeability of low water-cement HSC.

  • PDF

Miniaturized Broadband ENG ZOR Antenna Using a High Permeability Substrate

  • Ko, Seung-Tae;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.201-206
    • /
    • 2011
  • This paper presents a miniaturized epsilon negative (ENG) zeroth-order resonance (ZOR) patch antenna with an improved bandwidth. The miniaturization and the broad bandwidth of the ENG ZOR patch antenna are achieved by using a meandered via and a high permeability substrate instead of a straight via and a dielectric substrate. The use of a meandered via allows miniaturization of the ENG ZOR patch antenna without narrowing the bandwidth. The use of a high permeability substrate allows further miniaturization of the ENG ZOR patch antenna and improvement of the bandwidth. A high permeability substrate consisting of a multi-layered substrate is designed to have a small material loss. The antenna (kr=0.32) has a 10 dB fractional bandwidth of ~1 %, which is 1.74 times as broad as that of an antenna with a dielectric substrate.

팁페이파 및 필터권지 기공도 조합이 제품담배 공기희석율에 미치는 영향 (Effects of Tipping Paper and Plug Wrap on Cigarette Filter Ventilation)

  • 김정열;김종열;신창호
    • 한국연초학회지
    • /
    • 제23권1호
    • /
    • pp.60-64
    • /
    • 2001
  • The variability of a ventilated filter cigarette depends on the details of its construction and one properties of its components and the variations in filter ventilation is effected by many factors such as tobacco column pressure drop, filter pressure drop, tipping paper and plug wrap permeability, and vent position. In this study, the effects of combination of tipping paper and plug wrap on filter ventilation of cigarettes were studied for the target ventilation level under the specific tobacco column and filter tip in order to reduce the variation of filter ventilation. When Nicolas Baskevitch\`s equation on filter ventilation was used to try out Monte Carlo Simulation, at the combination where tipping paper permeability is high and plug wrap permeability is low, even the small change in tipping paper and plug wrap permeability showed high variation of target ventilation level. Also, according to the analysis data of filter ventilation in cigarettes designed at the level of 45% filter ventilation by the combinations with tipping paper and plug wrap, the variation in cigarette filter ventilation was increased as increasing tipping paper permeability and decreasing plug wrap permeability. As the results of this study, the variation of filter ventilation can be reduced by increasing plug wrap permeability/tipping paper permeability ratio in the cigarette design, considering 2-3% of tipping paper permeability variation(%CV) and about 10% of plugwrap permeability variation.

  • PDF

Effect of damage on permeability and hygro-thermal behaviour of HPCs at elevated temperatures: Part 1. Experimental results

  • Gawin, D.;Alonso, C.;Andrade, C.;Majorana, C.E.;Pesavento, F.
    • Computers and Concrete
    • /
    • 제2권3호
    • /
    • pp.189-202
    • /
    • 2005
  • This paper presents an analysis of some experimental results concerning micro-structural tests, permeability measurements and strain-stress tests of four types of High-Performance Concrete, exposed to elevated temperatures (up to $700^{\circ}C$). These experimental results, obtained within the "HITECO" research programme are discussed and interpreted in the context of a recently developed mathematical model of hygro-thermal behaviour and degradation of concrete at high temperature, which is briefly presented in the Part 2 paper (Gawin, et al. 2005). Correlations between concrete permeability and porosity micro-structure, as well as between damage and cracks' volume, are found. An approximate decomposition of the thermally induced material damage into two parts, a chemical one related to cement dehydration process, and a thermal one due to micro-cracks' development caused by thermal strains at micro- and meso-scale, is performed. Constitutive relationships describing influence of temperature and material damage upon its intrinsic permeability at high temperature for 4 types of HPC are deduced. In the Part II of this paper (Gawin, et al. 2005) effect of two different damage-permeability coupling formulations on the results of computer simulations concerning hygro-thermo-mechanical performance of concrete wall during standard fire, is numerically analysed.

Analysis of permeability in rock fracture with effective stress at deep depth

  • Lee, Hangbok;Oh, Tae-Min;Park, Chan
    • Geomechanics and Engineering
    • /
    • 제22권5호
    • /
    • pp.375-384
    • /
    • 2020
  • In this study, the application of conventional cubic law to a deep depth condition was experimentally evaluated. Moreover, a modified equation for estimating the rock permeability at a deep depth was suggested using precise hydraulic tests and an effect analysis according to the vertical stress, pore water pressure and fracture roughness. The experimental apparatus which enabled the generation of high pore water pressure (< 10 MPa) and vertical stress (< 20 MPa) was manufactured, and the surface roughness of a cylindrical rock sample was quantitatively analyzed by means of 3D (three-dimensional) laser scanning. Experimental data of the injected pore water pressure and outflow rate obtained through the hydraulic test were applied to the cubic law equation, which was used to estimate the permeability of rock fracture. The rock permeability was estimated under various pressure (vertical stress and pore water pressure) and geometry (roughness) conditions. Finally, an empirical formula was proposed by considering nonlinear flow behavior; the formula can be applied to evaluations of changes of rock permeability levels in deep underground facility such as nuclear waste disposal repository with high vertical stress and pore water pressure levels.

Effect of Surface Finishing Materials on the Moisture Conditions in Concrete: Vapor and Water Permeability of Finishing Materials Under Changing Environmental Conditions

  • Ryu, Dong-Woo
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권2호
    • /
    • pp.83-90
    • /
    • 2008
  • Permeability to vapor and water among other performances required for finishing materials is dealt with in this study. The relative moisture content of concrete coated/covered with a finishing material was experimentally investigated while changing the environmental conditions including temperature, relative humidity, and rainfall. An organic paint (water-based urethane), organic synthetic resin emulsion-type film coating (film coating E), and inorganic porcelain tiles were selected as the finishing materials. When compared from the aspect of vapor and water permeability, the vapor permeability and water permeability of water-based urethane were high and low, respectively; those of film coating E were high and high, respectively; and those of porcelain tiles were low and low, respectively. This means that the moisture state of concrete structures is governed not only by the environmental conditions but also by the performance of finishing materials. It is therefore of paramount importance to appropriately select a finishing material to address the specific deteriorative factors involved in the concrete structure to be finished.

고주파 Chip-Inductor용 NCZF 전자기적 특성 (Electric and Magnetic Properties of NCZF for High Frequency Chip-Inductor)

  • 정승우;김태원;김성수;백승철;최우성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.80-83
    • /
    • 1999
  • We have studied properties(crystal structure, density, absorption, contraction, initial permeability, and permeability) of Ni$_{0.175-x}$Cu$_{x}$Zn$_{0.33}$Fe$_{0.495}$ (x=0~0.175) ferrites with various NiO and CuO, because of development of materials for high frequency inductor. The XRD peaks of all of samples were observed only spine이 phase. As a results of the density, absorption rate, and shrinkage rate, the grain growth progressed rapidly in x=0.1 at 95$0^{\circ}C$, x=0.075 at 105$0^{\circ}C$, and x=0.025 at 115$0^{\circ}C$ for 3 hours. Initial permeability increased with increasing CuO concentration until x=0.1, and then decreased. The complex permeability as a function frequency were high values at sintered 105$0^{\circ}C$ fotr3 hours in x=0.075, 0.1., 0.1.1.

  • PDF

충적층 차수벽으로서 CJM Grouting (CJM Grouting to Reduce the Permeability in Alluvium)

  • 천병식;양형칠
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.253-263
    • /
    • 2005
  • There were no cases to use CJM Grouting to Reduce the Permeability of open-cut in Alluvium adjacent to Han River. In this paper, the applicability of CJM Grouting to Reduce the Permeability in Alluvium is reasonably estimated by in-situ Permeability test and coring. It is known that the range of improvement is decided by injection pressure, time of high pressure water and by slump, injection pressure of injection materials.

  • PDF

붕괴가 발생한 급경사지의 현장 투수계수 (Permeability Coefficient of Unsaturated Soil in Steep Slope Failure Area)

  • 최은경;김성욱;박덕근;오정림
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.921-926
    • /
    • 2010
  • To examine saturation characteristics of an unsaturated soil in the steep slope area with collapse, it separated dry season from rainy season and measured water content and permeability, and measured permeability by using a tension infiltrometer in the site. In addition, it conducted electrical resistivity survey to look into thickness of ground and geological structure of underground. The collapsed slope increased depth of weathered zone compared to upper slope, and there electrical resistivity anomalous zone caused by the filtrated underground water was observed. The permeability of the collapsed area was observed high compared to upper and lower slopes of retarding basin without collapse, and the permeability measured by dividing the dry season and rainy season was measured high in case of dry season.

  • PDF

고차단성 자동차 부품용 고무소재 (Elastomeric High Barrier Materials for Vehicle)

  • 김진국
    • Elastomers and Composites
    • /
    • 제46권1호
    • /
    • pp.2-9
    • /
    • 2011
  • 가스와 증기에 대한 투과성(Permeability to gases and Vapors)은 고무 제품을 타이어 튜브나 다이아후램(diaphragm)과 같은 제품으로 사용하고자 할 때 아주 중요한 특성이다. 모든 고무는 가스와 증기에 대하여 투과성이 있다. 그러나 그 투과 속도는 고무 재질에 따라 아주 다르다. 일반적으로 실리콘 고무의 투과성이 제일 크고, 그 다음으로 NR, EPDM, SBR, CR, NBR, FPM, ECO, IIR 순이다. 이러한 투과성은 같은 원료고무를 사용해도 사용 배합약품의 종류에 따라 크게 다를 수도 있다. 고무와 기체와의 메커니즘은 발포고무에 매우 중요하게 되어 이에 대한 연구$^{1-7}$는 많이 이루어졌으나 고무의 차단성에 대한 연구는 그리 많지 않다. 고무소재의 투과성 또는 차단성 기능을 주기위하여 나노복합탄성체$^8$의 기술 동향 및 코팅에 의한 기능성 향상$^{9-13}$을 하거나 열가소성탄성체 본문에서 적용하는 기술이 있는데 자동차에 사용되는 액체 및 기체 차단용 고무부품에 대하여 몇가지 소개하여 본다.