• 제목/요약/키워드: High performance liquid chromatography-UV

검색결과 276건 처리시간 0.025초

Simultaneous Determination of Alkaline Earth Metal Ions by a Conventional High Performance Liquid Chromatographic System

  • Rho, Young-Soo;Choi, Seung-Gi
    • Archives of Pharmacal Research
    • /
    • 제9권4호
    • /
    • pp.211-214
    • /
    • 1986
  • A simultaneous determination method of alkaline earth metals was attempted with the conventional high performance liquid chromatographic system. Four cations, namely, magnesium, calcium, strontium and barium ion, were injected directly as aqueous solution into an eluent containing copper chloride solution and and were successfully separated and determined on a separating column (Zipax SCX, 4.6 mm i.d. ${\times}25$ cm length, Du Pont, USA) by using a variable wavelength UV detector. The linear calibration curves were obtianed in the range from $1.0{\times}10^{-4}M$ to $5.0{\times}10^{-4}M$ and the correlation coefficient of the calibration curve for each metal of magnesium and calcium in tap water. Alkaline earth metals were determined with the conventional high performance liquid chromatographic system.

  • PDF

DETERMINATION OF SIMVASTATIN IN HUMAN PLASMA BY COLUMN SWITCHING HPLC WITH UV DETECTION

  • Ban, Eun-Mi;Kim, Bae-Chan;Park, Tae-Hwan;Kim, Chong-Kook
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.281.1-281.1
    • /
    • 2003
  • Purpose. The purpose of this study was to develop and validate sensitive and specific analytical method for determinination of simvastatin in human plasma by the column-switching high-performance liquid chromatography (HPLC) system with UV detection. Methods. Simvastatin and internal standard were extracted into diethyl ether from plasma. (omitted)

  • PDF

적출 흰쥐 간 관류법에 의한 이황화탄소 대사에 관한 연구 (A Study on the Metabolism of Carbon Disulfide by Isolated Rat Liver Perfusion)

  • 조영봉;배문주;최홍순;노재훈
    • 한국산업보건학회지
    • /
    • 제6권2호
    • /
    • pp.202-208
    • /
    • 1996
  • The purposes of this study are the identification and determination of metabolites in the isolated rat liver perfusate of carbon disulfide by two-dimentional thin-layer chromatography and high performance liquid chromatography for understanding the metabolism of carbon disulfide. 2-Thio-thiazolidine-4-carboxylic acid(TTCA) was synthesized by the reaction of carbon disulfide and cysteine, and confirmed by two-dimentional thin-layer chromatography, high performance liquid chromatography, UV spectroscopy, and IR spectroscopy. The absorbance of UV detector for the simultaneous determination of TTCA and thiocarbamide was 254 nm although their maximum spectra were 273 nm and 237 nm, respectively. Two kinds of the developing solvent in the two-dimentional thin-layer chromatography were 2-butanol : 80% HCOOH : $H_2O$ (7 : 2 : 1) as the first developing solvent and 2-propanol : $H_2O$ (4 : 1) as the second developing solvent. After perfusion of carbon disulfide ($8274.23{\mu}mol$), the amount of TTCA and thiocabamide of the perfusate(100 ul) were $12.02-16.4{\mu}mol$ and $5.25-8.15{\mu}g$, respectively. The mean amount of them were $14.08{\mu}mol$ and $6.41{\mu}mol$ respectively, and the former was 2.20 times greater than the latter. For conforming the mechanism of formations of TTCA and thiocarbamide in vivo, we have to clarify whether the reactions between carbon disulfide and ammonia, ammonium salts, amides, cysteine, cystine, or proteins will be formed in vitro.

  • PDF

Analysis of flavonoids in the mature fruit of Vaccinium uliginosum L. of China

  • Hua, Lian Li;Yoshitama, Kunijiro
    • Advances in Traditional Medicine
    • /
    • 제6권1호
    • /
    • pp.65-67
    • /
    • 2006
  • In this study, a new extraction method was developed and two kinds of flavonoids were extracted from the mature fruit of Vaccinium uliginosum L. of China. These two kinds of flavonoids were analyzed by spectral and identified by high-performance liquid chromatography (HPLC) and UV/Vis. The extract of the fruit was total acid hydrolyzed. TLC chromatography was subsequently employed to identify the hydrolysate. Two kinds of aglycone flavonoids, quercetin and myricetin, were identified. At the same time PC chromatography was used to identify the monomer sugar in the flavonoids and it was verified as glucose. HPLC, UV/Vis, and Mass spectrum analyses revealed that the flavonoids were quercetin 3-monoglucosides and myricetin 3-monoglucosides.

고성능 액체크로마토그래피를 이용한 식이보충제에서 크레아틴, 디시안디아마이드, 디하이드로트리아진의 동시분석 (Simultaneous Determination of Creatine, Dicyandiamide and Dihydrotriazine in Dietary Supplements by High Performance Liquid Chromatography)

  • 박상욱;유명상;이원재
    • KSBB Journal
    • /
    • 제29권4호
    • /
    • pp.232-238
    • /
    • 2014
  • The simultaneous determination of creatine monohydrate (CrM), dicyandiamide and dihydrotriazine in dietary supplements using reversed-phase high performance liquid chromatography (HPLC) was developed. Chromatography was performed on a Nuclosil 100-5 SA ($4.6{\times}250mm$) column with a mobile phase of 2.3% ammonium phosphate (pH 5.5), and UV detection at 224 nm, 212 nm, and 237 nm, respectively. The performance characteristics of HPLC were determined in terms of selectivity, linearity, precision, recovery, limit of detection (LOD), and limit of quantification (LOQ). The calibration curves were linear within the concentration range of $40.0{\sim}500.0{\mu}g/mL$ for creatine, $0.1{\sim}12.8{\mu}g/mL$ for dicyandiamide, and $0.05{\sim}6.4{\mu}g/mL$ for dihydrotriazine. The detection limits of the method were 1.09, 0.01, and $0.08{\mu}g/mL$ for creatine, dicyandiamide, and dihydrotriazine, respectively. The recoveries of creatine, dicyandiamide, and dihydrotriazine were 97.2~100.9, 92.3~106.5, and 97.2~105.5%, respectively. It is expected that the chromatographic analytical method developed in this study will be usefully applicable to simultaneous determination of creatine, dicyandiamide, and dihydrotriazine contained in dietary supplements.

HPLC-UV검출방법으로 유도체화를 통한 비테인과 콜린의 동시분석 (Simultaneous determination of betaine and choline using derivatization by HPLC with UV detection)

  • 이인숙;팽기정
    • 분석과학
    • /
    • 제28권2호
    • /
    • pp.112-116
    • /
    • 2015
  • Extraction of quaternary ammonium compounds (choline and betaine) from plant samples (spinach) using ion exchange resin (AG1, OH form) is a very simple and inexpensive approach. However, it is very hard to determine amounts of choline and betaine simultaneously using high-performance liquid chromatography-ultraviolet (HPLC-UV) detection. Unlike choline, betaine has low molar absorptivity in UV-visible (UV-Vis) region, which makes it difficult to carry out UV-Vis detection of betaine. The mixture of quaternary ammonium compounds (choline and betaine) was derivatized using 2-bromo acetophenone as a derivatizing agent. As a result, choline did not react with the derivatizing agent, whereas betaine formed a betaine derivative. This betaine derivative exhibited detectable UV absorption with baseline separation between choline and the betaine derivative. Thus, with this method, choline and betaine can be determined simultaneously by using the HPLCUV method through one-step derivatization, which is an easy, sensitive, and reliable method.

고성능 액체 크로마토그래피에 의한 식품 및 비타민 제제중의 지용성 비타민의 동시 분석에 관한 연구 (A Study on the Simultaneous Analysis of Fat-Soluble Vitamins in Food Stuffs and Vitamin Products by High Performance Liquid Chromatography)

  • 김풍작;김종혁
    • 대한화학회지
    • /
    • 제33권1호
    • /
    • pp.46-54
    • /
    • 1989
  • 식품 및 비타민 제제중에 존재하는 지용성 비타민의 추출 및 동시 정량법을 검토하였다. 역상 액체크로마토그래피에 의한 지용성 비타민의 동시 분리 및 정량은 메탄올 : 물 = 95 : 5 이동상으로 Novapak $C_{18}$ 컬럼하에서 이루어졌다. 비타민의 검출에는 UV검출기를 사용하였으며 검출감도를 증가시키기 위하여 분석중 UV 검출파장을 각각의 비타민 용리시간에 따라 최대흡수 파장인 330, 265, 285 및 290nm로 변경하였다. 지용성 비타민의 분리 및 분석은 40분안에 완료되었다. 시료의 전처리에는 알카리 가수분해법과 효소가수분해법을 이용하였으며, 비타민의 추출은 액체-액체추출법과 액체-고체추출법을 이용하였다. 비타민 A,D, E 분석에는 알카리 가수분해법 및 효소가수분해법이 비타민 K 분석에는 효소가수분해법만이 좋은 결과를 나타냈으며, 비타민 추출에는 액체-액체 추출시 diethyl ether, pentane 및 n-hexane이, 액체-고체 추출시 silica 카트리지가 좋은 추출효과를 나타냈다.

  • PDF

New Polyacetylene Compounds from Panax Ginseng C. A. Meyer$^\dag$

  • Shim, Sang-Chul;Chang, Suk-Ku;Hur, Chan-Woo;Kim, Chang-Kew
    • Bulletin of the Korean Chemical Society
    • /
    • 제8권4호
    • /
    • pp.272-275
    • /
    • 1987
  • Two polyacetylene compounds having diyn-ene chromophore were isolated from fresh Korean ginseng roots through solvent fractionation, partition and silica gel column chromatography. The low pressure semi-preparative liquid chromatography and high performance preparative liquid chromatography were used for final separation of polyacetylenic fractions. The chemical structures of these polyacetylenes were determined to be heptadeca-1,8-dien-4,6-diyn-3,10-diol and heptadeca-1,4-dien-6,8-diyn-3,10-diol by UV, FT-IR, $^1H\;NMR,\;^{13}C\;NMR,$ mass spectra and elemental analysis.

Liquid chromatographic determination of α-, β-, γ-, and δ-tocopherol in sesame oils of different origin

  • Kim, Shin-Ok;Kim, Nam-Sun;Noh, Bong-Soo;Lee, Dong-Sun
    • 분석과학
    • /
    • 제15권3호
    • /
    • pp.248-255
    • /
    • 2002
  • The contents of ${\alpha}$-, ${\beta}$-, ${\gamma}$-, and $\delta$-tocopherols in sesame oils were determined by high performance liquid chromatography with UV detection. ${\alpha}$-Tocopherol contents ranged from 10.28 to 19.79 mg/g oil, ${\beta}$-tocopherol contents from 8.22 to 20.10 mg/g. However, both ${\gamma}$- and $\delta$-tocopherol were less than 1.49 mg/g or not detected. ${\gamma}$-Tocopherol was not detected from both unroasted white and black sesame seed oils. Significantly higher level of tocopherol in sesame oil than other oils is an evidence of the reason why it is highly stable and prevents oxidation. The tocopherol composition for twenty sesame oils was classified by using principal component analysis.

소변 중 뮤콘산의 친환경 HPLC 분석방법을 이용한 벤젠 노출 생물학적 노출평가 (Environmentally friendly determination of urinary trans, trans-muconic acid for biological monitoring of benzene exposure by green high-performance liquid chromatography)

  • 양동혁;이미영;원용림
    • 분석과학
    • /
    • 제25권6호
    • /
    • pp.460-466
    • /
    • 2012
  • 벤젠 노출의 생물학적 노출인 인체 소변 중 뮤콘산(trans, trans-muconic acid) 분석을 위한 녹색 HPLC (Highr performance liquid chromatography) 분석방법을 개발하고 검증하였다. 이온교환수지 고상추출 카트리지를 사용하여 소변 중 뮤콘산을 추출하고, MF-Ph1 SG80 ($150mm{\times}2.0mm$ I.D., 5 ${\mu}m$) 칼럼과 이동상(10 mM $KH_2PO_4$+0.1% $H_3PO_4$)을 뮤콘산의 HPLC 분석에 사용하였으며 검출은 자외가시부검출기 259 nm에서 실시하였다. 0.1-5.0 mg/L 범위에서 상관계수 ($r^2$) 0.9992 이상의 양호한 직선성을 나타내는 검량선을 얻었다. 일내 및 일간 정밀성(RSD)은 각각 0.9-8.5% 및 3.1-4.5%였으며, 평균 회수율은 97.5-101.7% 범위였다. 본 연구에서는 유기 용매를 전혀 사용하지 않지만 기존 방법과 동일한 분석 성능을 가지고 있는 친환경 분석법을 개발하였다. 확립된 분석법은 벤젠 노출 평가를 위한 근로자의 생물학적 모니터링 방법으로 활용될 수 있을 것이다.