• 제목/요약/키워드: High ozone concentration

검색결과 298건 처리시간 0.032초

한강수계 고도정수처리 공정에서의 유기물과 맛·냄새의 제거특성 (Removal Characteristics of Natural Organic Matter and Taste and Odor by Advanced Water Treatment Process around the Han River Water Supply System)

  • 임재림;이경혁;김성수;채선하
    • 상하수도학회지
    • /
    • 제21권1호
    • /
    • pp.13-25
    • /
    • 2007
  • The water treatment plants in Seoul Metropolitan Area, which are under Korea Water Resources Corporation(KOWACO)'s management, take water from Paldang Reservoir in Han River System for drinking water supply. There are taste and odor (T&O) problems in the finished water because the conventional treatment processes do not effectively remove the T&O compounds. As part of countermeasures for taste and odor control, KOWACO is planning to introduce advanced water treatment process such as ozone and GAC in near future. This study evaluated the removal characteristics of T&O and dissolved organic matter (DOM) to find design and operation parameters of advanced water treatment processes in a pilot-scale treatment plant. The GAC adsorption capacity for DOC in the two GAC system (GAC and $O_3$-GAC) at an EBCT of 14min was mostly exhausted after 9months. The differency of the removal efficiency of DOC between $O_3$-GAC and GAC increased with increasing operation time because the bioactivity in $O_3$-GAC process was enhanced by post-ozone process. Removal by conventional treatment was unable to reach the target TON(threshold odor number) of 3 but GAC systems at an EBCT(empty bed contact time) of 14 min were able to archive the target with few exception. During the high T&O episodes, PAC as a pretreatment together with GAC could be useful option for T&O control. However, substantial TON removal continued for more than two year (> 90,000 bed volumes). At the spiking of less concentration 26 to 61 ng/L in the influent of GAC systems, GAC absorber and $O_3$-GAC processes could meet the treatment target. The better spike control after 12 and 19 months of operation compared to that after 7 months of operation is a strong indication of biological control. The results presented in this study had shown that $O_3$-GAC process was found to be more effective for T&O control than GAC process. And the main removal mechanism in GAC systems were adsorption capacity and biodegradation.

2002년에서 2004년 동안 서해상공에서 관측된 과산화수소의 농도분포 및 거동 (Distributions and Behaviors of H2O2 Above the Yellow Sea in the Years Between 2002 and 2004)

  • 김영미;신선아;한진석;이미혜;김주애
    • 한국대기환경학회지
    • /
    • 제21권6호
    • /
    • pp.689-697
    • /
    • 2005
  • Hydrogen peroxide is a reservoir of OH radical which is the powerful oxidant in the atmosphere. Therefore, the status of the oxidizing atmosphere could be reflected on the concentration of $H_{2}O_{2}$. In this study, the distribution of $H_{2}O_{2}$ was determined during the intensive aircraft measurements over the Yellow sea in March, December 2002, April, November 2003 and March, October 2004. Flights covered from $124^{circ}E\;to\;129^{circ}E\;and\;35^{circ}N\;to\;37^{circ}N$, and extending to 3,000 m. The flight patterns were set properly to assess the altitudinal and longitudinal distribution for $H_{2}O_{2}$. $H_{2}O_{2}$ was extracted onto aqueous solution using a continuously flowing glass coil and analyzed by a high performance liquid chromatography (HPLC) accompanied with a fluorescence detector using postcolumn enzyme derivatization. Mixing ratios of $O_{3},\;NO_{x}\;and\;SO_{2}$ were measured in real time by commercial analysis instruments. Along the heights, the maximum concentration of $H_{2}O_{2}$ appeared around 1,500 m then gradually decreased with increasing altitude. The vertical behavior of ozone showed the similar trend to $H_{2}O_{2}$. The mean mixing ratio of $NO_{x}$ was about 2 ppbv and not showed clear vertical distribution patterns. The mean value of was the same as $NO_{x}$ however $SO_{2}$ appeared extreme concentration in low altitude. $H_{2}O_{2}\;and\;O_{3}$ showed even longitudinal distribution however $NO_{x}$ mixing ratio in land ($127^{circ}E$) was much higher than over the sea. $SO_{2}$ rather decreased with increasing longitude. $H_{2}O_{2}$ was in inverse proportion to $NO_{x}$ in spring and summer and $SO_{2}$ in spring, which indicated its significant role to NO and $SO_{2}$ oxidation pathways.

WRF-SMOKE-CMAQ(MADRID)을 이용한 한반도 봄철 황사(PM10)의 농도 추정 (An Estimation of Concentration of Asian Dust (PM10) Using WRF-SMOKE-CMAQ (MADRID) During Springtime in the Korean Peninsula)

  • 문윤섭;임윤규;이강열
    • 한국지구과학회지
    • /
    • 제32권3호
    • /
    • pp.276-293
    • /
    • 2011
  • 본 연구에서는 한반도 황사 사례 동안 WRF 기상모델과 SMOKE 배출량모델, CMAQ 및 CMAQ-MADRID 대기질 모델을 이용하여 다양한 황사 발생량 경험식에 대한 $PM_{10}$의 농도를 추정하였다. 특별히 Wang et al.(2000), US EPA 모델, Park and In(2003), GOCART 모델, DEAD 모델의 5가지 황사 발생 경험식이 중국과 몽골 등의 황사 발생량을 추정하기 위해 WRF-SMOKE-CMAQ(MADRID) 모델에 적용되었다. 일기도, 후방궤적 및 위성이미지 분석에 따르면 한반도로의 황사 수송은 절리저기압(위성에서 콤마형 구름)과 관련된 지상 전선의 뒤쪽에서, 그리고 상층 제트류의 발달에 기인한 파의 정체현상과 함께 상층 골에서의 풍속이 하층으로 전이되는 풍하 바람에 의해 생성되었다. 그리고 WRF-SMOKE-CMAQ 모델링 결과, 황사의 시 공간적 분포에 있어서는 Wang et al.(2000)의 경험식이, 평균 편의 및 평균 제곱근 오차에서의 정확도 부분에서는 GOCART 모델의 경험식이 관측값을 보다 잘 모사하는 것으로 나타났다. 또한 Wang et al.의 경험식을 이용한 황사의 연직분포 분석 결과에서 강한 황사 사례(2007년 3월 31에서 4월 1일 $800\;{\mu}g/m^3$ 이상)의 경우는 황사 수송이 한반도 상공 대기 경계층 내를 통과하였기 때문으로, 약한 황사 사례(2009년 3월 16일과 17에 $400\;{\mu}g/m^3$ 이하)의 경우는 황사 수송이 경계층 위를 통과하였기 때문으로 나타났다. 또한 CMAQ 모델과 CAMQ-MADRID 모델에서의 미세먼지($PM_{10}$) 민감도 분석 결과에서는 CMAQ-MADRID 모델이 CMAQ 모델에 비해 한반도를 포함한 동아시아 지역에서 최대 $25\;{\mu}g/m^3$ 정도가 높게 모사되었고, 모델 내 구름 액상과정에 의해서는 최대 $15\;{\mu}g/m^3$ 정도가 제거되는 것으로 나타났다.

공간 분석을 통한 부산광역시 대기오염물질의 분포와 이동오염원 간의 관련성 연구 (Analysis of the Association between Air Pollutant Distribution and Mobile Sources in Busan Using Spatial Analysis)

  • 민재희;김병권;주현지;김나영;황용식;이승호;홍영습
    • 한국환경보건학회지
    • /
    • 제50권3호
    • /
    • pp.191-200
    • /
    • 2024
  • Background: Busan is a rapidly industrializing city with many mixed residential and industrial areas. Fine dust emissions from mobile pollution sources such as ships and vehicles are particularly high in Busan. Objectives: This study analyzed the spatial distribution of air pollutants over the past three years and identified the impact of air pollutants through mobile source data in Busan. Methods: We obtained air pollutant data on fine particulate matter (PM10), ultrafine particulate matter (PM2.5), nitrogen dioxide (NO2), sulfurous acid gas (SO2), and ozone (O3) for the last three years (source: airkorea.or.kr) and analyzed the spatial distribution using SAS 9.4 and Surfer 23. For the mobile pollutant data, we used CCTV data from major intersections in Busan to identify truck and car traffic, and visualized traffic density with QGIS. Results: The analysis of the concentration of air pollutants over three years (2020~2022) showed that all were lower than the annual environmental standards with the exception of PM2.5. PM10 and PM2.5 were found to be highly concentrated in the western part of the area, while NO2 was high in the port area of Busan and SO2 was high in the western part of the area and near the new port of Busan. In the case of O3, it was high in the eastern part of the city. The traffic volume of freight vehicles by intersection was concentrated in the West Busan area, and the traffic volume for all cars was also confirmed to be concentrated at "Mandeok Intersection" located in the West Busan area. Conclusions: This study was conducted to determine the relationship between air pollutants emitted from motor vehicles and the distribution of air pollutants in Busan. The spatial distribution of PM10 and PM2.5 correlates with traffic volume, while high concentrations of SO2 and NO2 near the port are associated with ship emissions.

준 실시간 화학적 조성자료를 이용한 미세입자 연무 에피소드 규명 (Investigation on a Haze Episode of Fine Particulate Matter using Semi-continuous Chemical Composition Data)

  • 박승식;김선정;공부주;이권호;조석연;김종춘;이석조
    • 한국대기환경학회지
    • /
    • 제29권5호
    • /
    • pp.642-655
    • /
    • 2013
  • In this study, semi-continuous measurements of $PM_{2.5}$ mass, organic and elemental carbon (OC and EC), black carbon (BC), and ionic species concentrations were made for the period of April 03~13, 2012, at a South Area Supersite at Gwangju. Possible sources causing the high concentrations of major chemical species in $PM_{2.5}$ observed during a haze episode were investigated. The measurement results, along with meteorological parameters, gaseous pollutants data, air mass back trajectory analyses and PSCF (potential source contribution function) results, were used to study the haze episode. Substantial enhancements of OC, EC, BC, $K^+$, $SO{_4}^{2-}$, $NO{_3}{^-}$, $NH{_4}{^+}$, and CO concentrations were closely associated with air masses coming from regions of forest fires in southeastern China, suggesting likely an impact of the forest fires. Also the PSCF maps for EC, OC, $SO{_4}^{2-}$, and $K^+$ demonstrate further that the long-range transport of smoke plumes of forest fires detected over the southeastern China could be a possible source of haze phenomena observed at the site. Another possible source leading to haze formation was likely from photochemistry of precursor gases such as volatile organic compounds, $SO_2$, and $NO_2$, resulting in accumulation of secondary organic aerosol, $SO{_4}^{2-}$ and $NO{_3}{^-}$. Throughout the episode, local wind directions were between 200 and $230^{\circ}C$, where two industrial areas are situated, with moderate wind speeds of 3~5 m/s, resulting in highly elevated concentration of $SO_2$ with a maximum of 15 ppb. The $SO{_4}^{2-}$ peak occurring in the afternoon hours coincided with maximum ambient temperature ($24^{\circ}C$) and ozone concentration (~100 ppb), and were driven by photochemistry of $SO_2$. As a result, the pattern of $SO{_4}^{2-}$ variations in relation to wind direction, $SO_2$ and $O_3$ concentrations, and the strong correlation between $SO_2$ and $SO{_4}^{2-}$ ($R^2=0.76$) suggests that in addition to the impact of smoke plumes from forest fires in the southeastern China, local $SO_2$ emissions were likely an important source of $SO{_4}^{2-}$ leading to haze formation at the site.

무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석 (An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer)

  • 오인환;이종현;이경훈;이정훈;이동섭;어성만;이미림
    • 한국축산시설환경학회지
    • /
    • 제12권3호
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.

  • PDF

산화물 반도체형 후막 가스 센서의 이산화질소 감지 특성 ($NO_{2}$ Sensing Properties of Oxide Semiconductor Thick Films)

  • 김승렬;윤동현;홍형기;권철한;이규정
    • 센서학회지
    • /
    • 제6권6호
    • /
    • pp.451-457
    • /
    • 1997
  • 산화물 반도체를 이용한 후막형 가스센서의 이산화질소에 대한 감지특성을 조사하였다. 기본 감지물질로는 $WO_{3}$, $SnO_{2}$, ZnO를 사용하였고, 여기에 다른 산화물 반도체를 소량 첨가하여 이산화질소에 대한 감지특성을 실험하였다. 동작온도에 따른 후막센서의 감지특성에서 감도, 회복특성을 고려할 때, $WO_{3}$$SnO_{2}$계 감지물질은 $300^{\circ}C$, ZnO계 감지물질은 $220{\sim}260^{\circ}C$ 정도의 동작온도에서 최적의 감지특성을 보였다. 그러나, ZnO계 감지물질은 큰 센서저항으로 인해 안정한 신호를 얻을 수 없었다. 오존, 암모니아, 에탄올, 메탄, 일산화탄소/프로판 혼합가스에 대한 선택성 실험에서 $WO_{3}$-ZnO(3 wt.%)와 $SnO_{2}-WO_{3}$(3 wt.%) 후막센서가 가장 우수한 이산화질소 감지특성을 보였다. 또한, 이들 후막센서들은 반복실험 및 농도의존성 실험을 통해서도 우수한 신호재현성을 보였으며 특히, 1 ppm 이하의 이산화질소를 검지, 정량화 할 수 있음을 보여 주었다.

  • PDF

강화지역의 기후특성 분석을 통한 '강화약쑥'의 생육 환경 연구 (Study on the Growth Environment of 'Gangwha-mugwort' Through the Climatological Characteristic Analysis of Gangwha Region)

  • 안중배;허지나;정해곤;박종호
    • 한국농림기상학회지
    • /
    • 제14권2호
    • /
    • pp.71-78
    • /
    • 2012
  • 본 연구에서는 Eupatilin이 고함유된 약쑥의 생육환경을 구명하고자 하였다. 이를 위해서 먼저 선행연구를 통해 Eupatilin이 고함유된다고 알려진 강화지역의 기상학적 특성을 살펴보고, 재배지역별, 수확시기별 Eupatilin 함유량과 기상요소와의 관계를 분석 하였다. 또한 강화지역의 해양, 대기질, 토양 그리고 약쑥 생육지 분포 자료를 이용하여 환경학적 조건도 분석 하였다. 결과적으로 일조시간이 길고 일교차가 큰 지역이 유효 성분이 많이 함유된 약쑥 생산에 유리한 환경이며, 강화도는 주변 지역에 비해서 일조시간이 길며 일교차가 크기 때문에 Eupatilin 함량이 많은 약쑥의 재배 및 서식처로써 적합한 지역으로 사료되었다. 또한 강화는 약한 해풍과 주변 해역의 낮은 염분도에 의해 유입되는 염분의 양이 다른 해안지방에 비하여 낮으며 다른 지역과 비교해볼 때 청정한 대기환경을 가지고 있는 것으로 분석되었다. 이와 더불어, 강화지역은 산지 주변으로 배수가 양호한 사양 질 내지 식양 질이 많이 분포하는데 이러한 토양 분포는 약쑥 생육지 분포와 일치하였다. 즉, 적절한 염분의 유입과 청정한 대기 그리고 배수가 양호한 토양이 Eupatilin 함유에 유리한 환경이 되었을 것으로 사료되었다.

시판 수계/준수계 세정제의 세정성 및 환경성 평가 연구 (Evaluation of Cleaning ability and Environmental Evaluation of Commercial Aqueous/Semi-aqueous Cleaning Agents)

  • 차안정;박지나;김한성;배재흠
    • 청정기술
    • /
    • 제10권2호
    • /
    • pp.73-87
    • /
    • 2004
  • 세정은 거의 모든 산업분야에서 필요한 중간 공정으로 대부분의 산업분야에서 제품상의 이물질 제거를 위해 세정을 실시고 있으며 세정제로 CFC-113, 1,1,1-TCE (1,1,1-trichloroethane), MC (methylene chloride), TCE 등 과 같은 세정성과 재질호환성이 양호한 염소계세정제를 사용하여 왔다. 그러나 CFC-113, 1,1,1-TCE는 오존파괴 물질로 선진국에서는 이미 사용이 금지되어 있고 MC, TCE는 유해성 또는 발암물질로 판명되어 일부사업장에서 제한적으로 사용되고 있다. 그러므로 세정성이 좋고 환경/안전성이 우수한 대체세정제를 개발하여 사용 하거나 기존 개발된 세정제 중에서 우수한 세정제를 선정하여 사용하는 것이 필요한 실정이다. 대체세정제로는 수계/준수계세정제가 환경성과 경제적면에서 유망한 것으로 평가받고 있어 많은 사업장에서 사용될 전망이다. 이에 본 연구에서는 시판되고 있는 수계세정제 12종, 준수계세정제 6종을 선정하여 물성, 세정성, 헹굼성, 헹굼수 재활용성 등에 관한 비교 연구를 수행하였다. 그 결과 수계세정제는 습윤지수가 클수록 세정이 좋았지만 준수계세정제는 습윤지수와 연관이 없었다. 그리고 수계세정제와 준수계세정제에 의한 세정성과 헹굼성을 좋게 유지하기 위하여서는 일정농도 이하로 오염물의 농도 관리가 필요한 것으로 나타났다. 수계, 준수계세정제는 종류에 따라서 단순 정치분리법에 의하여 헹굼수 중의 오염물을 70% 이상 용이하게 제거할 수 있었다. 이것은 일부 세정제는 오염된 헹굼수 중에서 높은 유수분리 효율이 있어 헹굼수 중의 오염물을 제거하고 물을 재활용하는데 효율적임을 말해준다. 그리고 수계세정제가 함유된 오염물은 30 kDa 세공크기의 PAN 막을 사용한 한외여과방법에 쉽게 정화될수 있었다.

  • PDF

비스페놀 A 수용액의 대기압 플라즈마 처리 (Atmospheric Pressure Plasma Treatment of Aqueous Bisphenol A Solution)

  • 조진오;최경윤;김수지;목영선
    • 공업화학
    • /
    • 제26권3호
    • /
    • pp.311-318
    • /
    • 2015
  • 내분비계교란물질로 알려진 비스페놀 A (bisphenol A, BPA) 수용액의 플라즈마 처리 및 분해 경로에 대해 조사하였다. 플라즈마화된 기체와 BPA 수용액을 효과적으로 접촉시키기 위하여 다공성 세라믹 관내에서 플라즈마를 생성시켜 세라믹 관의 세공을 통해 수중으로 고르게 분산시켰다. 기체의 유량, 인가 전압, 처리시간이 BPA 분해에 미치는 영향을 조사하였으며, 자외선 분광광도계, 이온 크로마토그래피, 기체크로마토그래피-질량분석기를 활용한 분석을 통해 반응 경로를 제시하였다. 기체의 유량이 너무 크거나 작으면 동일한 전력이 공급되더라도 처리효과가 떨어지며 적정한 기체 유량은 $1.0L\;min^{-1}$인 것으로 나타났다. 전압이 높을수록 많은 전력이 공급되므로 BPA를 제거하는 시간이 단축되나, 소모되는 에너지는 전압에 관계없이 유사하였다. 유량 $1.0L\;min^{-1}$과 전압 20 kV 조건에서 초기농도 $10L\;min^{-1}$ (부피 : 1 L)인 BPA가 30 min 이내에 모두 제거되었다. 오존이나 하이드록실 라디칼과 같은 활성성분들에 의해 BPA 구조가 파괴되어 생성되는 중간생성물들은 후속 산화반응을 통해 아세테이트, 포메이트, 옥살레이트와 같은 안정한 물질로 전환됨을 확인하였다.