• Title/Summary/Keyword: High level ozone

Search Result 75, Processing Time 0.026 seconds

Discharge Properties of Torch-Type Atmospheric Pressure Plasma and Its Local Disinfection of Microorganism (토치형 상압 플라즈마의 방전특성과 미생물의 국부 살균효과)

  • Son, Hyang-Ho;Lee, Won-Gyu
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.835-839
    • /
    • 2011
  • The characteristics of torch-type atmospheric pressure plasma and its sterilization effects have been analyzed. The length of plasma flame was varied with the level of applied voltage and the mixture gases composed of argon and oxygen. The effect of plasma flame on the temperature increase of surface treated was limited to $43^{\circ}C$ as a maximum temperature under exposing time of 10 min. The sterilization for E. coli was strongly affected by the applied voltage, the oxygen ratio in the mixture gas and the treatment time. At a high concentration of ozone, the increase of treatment time under the direct contact with plasma flame yields to maximize the effect of the sterilization on E. coli.

Performance Evaluation of High-Level Ozone Prediction Model Based on the Confidence Level Test (신뢰수준평가에 기반한 고농도 오존 예측모델의 성능평가)

  • 정재룡;안항배;송치권;배현;전병희;김성신
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.12a
    • /
    • pp.195-198
    • /
    • 2002
  • 고농도오존이 발생되는 원인과 환경적 요인의 상호관계를 모델링하기 위해 신경회로 망과 같은 지능제어 기법들이 많이 적용되어 왔다 분석과 모델링을 위해 유전자 알고리즘과 같은 최적화 방법을 적용하기도 하지만, 고농도 오존이 발생되는 메커니즘이 매우 복잡하고, 비선형적이며, 패턴파악이 어렵기 때문에 고농도 오존의 예측 모델링에는 여전히 문제점이 있다 따라서 본 논문에서는 신뢰수준과 신뢰구간을 이용하여 초농도 오존을 예측할 수 있는 모델링 방법을 서술하였다 예측값의 신뢰수준의 평가는 예측에 대한 실측값을 구하여 신뢰구간내의 데이터의 개수를 파악함으로써 신뢰성을 평가할 수 있다. 또한 이 테스트는 우리가 가지고 있지 않은 데이터에 대한 유효성을 평가하는데 적용될 수 있다 그리고 본 논문에서는 GMDH(Group Method of data handling)의 전형적인 알고리즘에 바탕을 두고 있는 DPNN(Dynamic Polynomial Neural Network)를 이용하여 예측 모델을 구성하였다. DPNN은 데이터 해석이 용이하고 비선형적인 동적 시스템 예측에 유용하게 적용될 수 있는 장점을 가지고 있다.

The Exceedance Patterns of O3 Air Quality Standards from 31 Monitoring Stations in Seoul (오존의 환경기준 초과양상에 대한 연구)

  • Kim, Min-Young;Choi, Ye-Jin;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.23 no.8
    • /
    • pp.683-696
    • /
    • 2002
  • In this work. we investigated the ozone data sets that exceeded ambient air quality standards from 31 air quality monitoring stations dispersed across the Seoul metropolitan city during the period covering 1990 and 2000. To specifically describe spatial dependency of high level O$_3$ occurrence, we grouped our data into four different geographical ozone exceedance is much longer in SW than the other three sectors. When we compared the exceedance data in terms of occurrence frequency, the month of maximum frequency differed slightly among different sectors. Examination of long-term exceedance trend indicated that its frequency increased continuously from all sectors over the past years, although slightly opposite patterns existed in their absolute values. Most importantly, its peak occurrence frequency seemed to center in very recent years such as 1998 (NE sector) and 2000 (ail pattern sectors except NE). Consequently, we were able to describe the existence of certain patterns of ozone exceedance data sets in terms of both temporal and spatial scales.

Interference of Sulphur Dioxide on Balloon-borne Electrochemical Concentration Cell Ozone Sensors over the Mexico City Metropolitan Area

  • Kanda, Isao;Basaldud, Roberto;Horikoshi, Nobuji;Okazaki, Yukiyo;Benitez-Garcia, Sandy-Edith;Ortinez, Abraham;Benitez, Victor Ramos;Cardenas, Beatriz;Wakamatsu, Shinji
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.162-174
    • /
    • 2014
  • An abnormal decrease in ozonesonde sensor signal occurred during air-pollution study campaigns in November 2011 and March 2012 in Mexico City Metropolitan Area (MCMA). Sharp drops in sensor signal around 5 km above sea level and above were observed in November 2011, and a reduction of signal over a broad range of altitude was observed in the convective boundary layer in March 2012. Circumstantial evidence indicated that $SO_2$ gas interfered with the electrochemical concentration cell (ECC) ozone sensors in the ozonesonde and that this interference was the cause of the reduced sensor signal output. The sharp drops in November 2011 were attributed to the $SO_2$ plume from Popocat$\acute{e}$petl volcano southeast of MCMA. Experiments on the response of the ECC sensor to representative atmospheric trace gases showed that only $SO_2$ could cause the observed abrupt drops in sensor signal. The vertical profile of the plume reproduced by a Lagrangian particle diffusion simulation supported this finding. A near-ground reduction in the sensor signal in March 2012 was attributed to an $SO_2$ plume from the Tula industrial complex north-west of MCMA. Before and at the time of ozonesonde launch, intermittent high $SO_2$ concentrations were recorded at ground-level monitoring stations north of MCMA. The difference between the $O_3$ concentration measured by the ozonesonde and that recorded by a UV-based $O_3$ monitor was consistent with the $SO_2$ concentration recorded by a UV-based monitor on the ground. The vertical profiles of the plumes estimated by Lagrangian particle diffusion simulation agreed fairly well with the observed profile. Statistical analysis of the wind field in MCMA revealed that the effect Popocat$\acute{e}$petl was most likely to have occurred from June to October, whereas the effect of the industries north of MCMA, including the Tula complex, was predicted to occur throughout the year.

Performance Test of 21AFR Lean Fuel Module at Low and High Operating Conditions (21AFR 희박연료모듈의 저압 및 고압 연소성능시험)

  • Han, Yeoung-Min;Ko, Young-Sung;Yang, Soo-Seok;Lee, Dae-Sung
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.858-863
    • /
    • 2001
  • In this paper, the test and result of flow and combustion for 21AFR lean fuel models are described. The necessity to develop the low emission combustor has been issued from the concern on the increase of green house and the destruction of ozone layer. To evaluate the flow and combustion performance of new designed 21AFR lean modules, the hydraulic tests in stereo lithographic airflows models, the low pressure combustion tests in three injectors model for weak extinction and ignition and the high pressure combustion tests in single sector for NOx, SAE and efficiency are performed. The low pressure tests reveal that the governing parameters in weak extinction and ignition at atmospheric condition are prefilmer length, swirl flow rotation direction, secondary swirl angle and flow split. As a results of combustion test at high pressure, the efficiency and smoke level are satisfied with performance targets, but EINOx of 17.8 is higher than target value of 13.1. The high pressure tests show that the main parameters influenced on NOx are primary swirl angle, swirl flow rotation direction, heatshield exit angle and liner mixing hole location.

  • PDF

Performance Test of 21AFR Lean Fuel Module at Low and High Operating Conditions (21AFR 희박연료모듈의 저압 및 고압 연소성능시험)

  • Han, Yeoung-Min;Ko, Young-Sung;Yang, Soo-Seok;Lee, Dae-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1132-1137
    • /
    • 2002
  • In this paper, the test results of the combustion for 2 IAFR lean fuel models are described. The need for the low emission combustor has been issued from the concern on the increase of green house and the destruction of ozone layer. To evaluate the flow and combustion performance of newly designed 21AFR lean modules, the hydraulic tests in stereolithographic airflows models, the low pressure combustion tests in three injectors model for weak extinction and ignition and the high pressure combustion tests in single sector for NOx, SAE and efficiency are performed. The low pressure tests reveal that the governing parameters in weak extinction and ignition at atmospheric condition are prefilmer length, swirl flow rotation direction, secondary swirl angle and flow split. As a result of combustion test at high pressure, the efficiency and smoke level are satisfied with performance targets, but EINOx of 17.8 is higher than target value of 13.1 The high pressure tests show that the main parameters influenced on NOx are primary swirl angle, swirl flow rotation direction, heatshield exit angle and liner mixing hole location.

Research on the emission of electromagnetic waves in ambulance (구급차량 내 전자파 방출에 관한 조사)

  • Yun, Jong-Geun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.1
    • /
    • pp.61-69
    • /
    • 2019
  • Purpose: The study aims to provide basic data to enhance the health of paramedics responsible for patient transport and treatment by analyzing the exposure level of paramedics to electromagnetic waves generated by electric devices used in ambulances. Methods: The study measured electromagnetic waves in ambulances in N region from July to December 2018. ME3030B produced by German Gigahertz Solutions was used to measure these waves and the maximum value was selected by moving it slowly in various directions. Each measurement part was selected and the mean value was calculated by repeatedly measuring at 10-minute intervals three times in total: $1^{st}$, $2^{nd}$, and $3^{rd}$ phase. Results: Among the electrical devices installed in the patient room of the ambulance measured at distances of 1 cm or 30 cm, results showed a high level of electric waves at the inverter ($26.25{\pm}39V/m$) and high level of electromagnetic waves ($564.00{\pm}31.75nT$) at the ozone sterilizer. According to measurements toward the front near the driver's seat, results indicated high levels of electric waves ($3.67{\pm}1.15V/m$) and electromagnetic waves ($450.00{\pm}19.52nT$) at the black box hard drive. Conclusion: Electromagnetic waves within the ambulance were stable and not beyond the range that might impact human health. However, in the case of the black box hard drive ($3.67{\pm}1.15V/m$, $450.00{\pm}19.52nT$) located under the passenger seat, it may have a direct effect on the human body and, thus it is necessary to move it to a storage area further away from the paramedics to minimized the impact.

The evaluation of effects to preliminary control practice to decrease high ozone level for the preparation of the 2002 World Cup Game (2002년 월드컵경기 대비 오존저감을 위한 예행연습 효과 분석)

  • 김민영;이민환;안미진;김성신
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.137-137
    • /
    • 2001
  • 서울시는 인구과밀, 크고 낮은 많은 산들, 높은 차량증가율과 수도권의 공업과 인구집중화 등의 이유로 그간의 많은 노력과 행정력의 집중에도 불구하고 질소산화물과 오존농도는 오히려 증가패턴을 나타내고 있다. 2002년도는 세계적인 월드컵대회가 한일공동으로 개최될 예정이고, 개회식이 개최될 서울 마포구 상암동 일대는 월드컵경기장 공사와 주변정리 작업이 한창이다. 직선거리로 400-500m의 풍상측(주풍방향 서북풍)에는 세계에서 가장 큰 규모의 하나인 비위생적 쓰레기 매립지가 위치하고 있고 이는 15년간 9천2백만㎥의 쓰레기가 묻혔으며 매립이 중단된지 9년이 되었다. (중략)

  • PDF

A Study of De-electrification Characteristics of Charged Body By Soft X-Ray Ionizer (연X선 Ionizer에 의한 대전물체의 제전특성에 관한 연구)

  • 이동훈
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.67-73
    • /
    • 1998
  • The technology for neutralizing static electricity by soft X-ray radiation has been newly developed. This technology involves ionization of gas molecules in the vicinity of a charged substrate to generate ions and electrons to reduce electrostatic potential. The ULSI device substrate and liquid crystal display substrate tend to get charged instantly to a high potential level when they are handled in the manufacturing process. Soft X-ray radiation is adequate in air or $O_2$ gas at atmospheric pressure. This newly developed neutralization method is effective to be superior to the conventional technique, i.e., an ionizer by using corona discharge ,in every aspect. The new method features excellent neutralization capability and is able to completely reduce electrostatic potential to 0 V within a short time. Moreover, this is a very clean antistatic technology free from particle generation ,ozone generation, and electromagnetic noise, which are problems in using the corona discharge ionizer.

  • PDF

Development of a Transfer Function Model to Forecast Ground-level Ozone Concentration in Seoul (서울지역의 지표오존농도 예보를 위한 전이함수모델 개발)

  • 김유근;손건태;문윤섭;오인보
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.779-789
    • /
    • 1999
  • To support daily ground-level $O_3$ forecasting in Seoul, a transfer function model(TFM) has been developed by using surface meteorological data and pollutant data(previous-day [$O_3$] and [$NO_2$]) from 1 May to 31 August in 1997. The forecast performance of the TFM was evaluated by statistical comparison with $O_3$ concentration observed during September it is shown that correlation coefficient(R), root mean squared error(RMSE), normalized mean squared error(NMSE) and mean relative error(MRE) were 0.73, 15.64, 0.006 and 0.101, respectively. The TFM appeared to have some difficulty forecasting very high $O_3$ concentrations. To compare with this model, multiple regression model(MRM) was developed for the same period. According to statistical comparison between the TFM and MRM. two models had similar predictive capability but TFM based on $O_3$ concentration higher than 60 ppb provided more accurate forecast than MRM. It was concluded that statistical model based on TFM can be useful for improving the accuracy of local $O_3$ forecast.

  • PDF