• Title/Summary/Keyword: High level laser

Search Result 227, Processing Time 0.027 seconds

Clinical Effect Of Low Level Laser Therapy In The Treatment Of Dentin Hypersensitivity Following Periodontal Surgery (치주수술 후 상아질 지각과민증에 대한 저수준 레이저 처치의 임상적 효과)

  • Kim, Nam-Yun;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.230-243
    • /
    • 1996
  • Root surface exposure due to gingival recession after periodontal surgery, dentin exposure after root planing elicit pain response when exposed to mechanical, heat, chemical or osmotic stimulation. Especially, patients treated with periodontal surgery, show high frequency and there have been reports showing the 1 out of 7 patients have dentin hypersensitivity. There have been many studies on the clinical effects of various materials on the treatment of dentin hypersensitivity. but, none could provide absolute clinical efficacy. In this study, 45 teeth from 30 patients, who had had periodontal surgery and showed dentin hypersensitivity after surgery were chosen for the experimental group and they were illuminated with laser, 15teeth were chosen for the control group and they were not exposed to laser. After this dentin hypersensitivity was elicited by tactile, compressed air, cold water and then, the degree was evaluated using NRS(Numerical Rating Scale). And during LLLT(Low Level Laser Therapy) semiconductor laser using Gallium - Arsenide as a diode was illuminated for 180 seconds at a frequency of 7(500Hz). This therapy was done 10 times, and each time the changes in dentin hypersensitivity was evaluated using NRS. The results were as follows : 1. After treat with LLLT on dentin hypersensitivity due to periodontal surgery, 22.2% showed total loss of dentin hypersensitivity, 60.0% showed loss of tactile dentin hypersensitivity, 48.8% showed loss of compressed air dentin hypersensitivity, 22.2% showed loss of cold water dentin hypersensitivity. 2. As a result of clinical evaluation of dentin hypersensitivity using NRS, there was significant increase in improvement of dentin hypersensitivity in the experimental group compare to the control group(P<0.05). And there was almost no natural loss of dentin hypersensitivity in the control group. 3. In comparison of the stages of evaluation, there was significant difference in between experimental and control group. after the second visit(P<0.05), and the difference increased with each visit.

  • PDF

Assessment of Air Flow Misalignment Effects on Fume Particle Removal in Optical Plastic Film Cutting Process

  • Kim, Kyoungjin;Park, Joong-Youn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.51-58
    • /
    • 2020
  • Many types of optical plastic films are essential in optoelectronics display unit fabrication and it is important to develop high precision laser cutting methods of optical films with extremely low level of film surface contamination by fume particles. This study investigates the effects of suction and blowing air motions with air flow misalignment in removing fume particles from laser cut line by employing random particle trajectory simulation and probabilistic particle generation model. The computational results show fume particle dispersion behaviors on optical film under suction and blowing air flow conditions. It is found that suction air flow motion is more advantageous to blowing air motion in reducing film surface contamination outside designated target margin from laser cut line. While air flow misalignment adversely affects particle dispersion in blowing air flows, its effects become much more complicated in suction air flows by showing different particle dispersion patterns around laser cut line. It is required to have more careful air flow alignment in fume particle removal under suction air flow conditions.

A Study on High-precision Autofocus Matching Device for Smoke Detector Based on IR Laser (IR 레이저 기반 연기감지기를 위한 고정밀 자동초점 정합장치에 관한 연구)

  • Kim, Gwan-Hyung;Shin, Dong-Suk;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2759-2764
    • /
    • 2014
  • Smoke detector is commonly used to reduce fire detection time. However, technical problems regarding its inaccuracy of laser beam-receiving point on the surface of the sensor associated with incoming interference are identified when the laser transmitter and receiver are installed at a distance of about 100m. In this paper, we propose the auto focus alignment algorithm with high precision to adjust tilting angle of lasers caused by environmental interference so that solve existing issues using multi-level worm gear set.

Combined Heat Treatment Characteristics of Cast Iron for Mold Materials (금형재료용 주철강의 복합열처리 특성)

  • Hwang, Hyun-Tae;So, Sang-Woo;Kim, Jong-Do
    • Korean Journal of Materials Research
    • /
    • v.21 no.7
    • /
    • pp.364-370
    • /
    • 2011
  • Currently, there are two main issues regarding the development of core technologies in the automotive industry: the development of environmentally friendly vehicles and securing a high level of safety in the event of an accident. As part of the efforts to address these issues, research into alternative materials and new car body manufacturing and assembly technologies is necessary, and this has been carried out mainly by the automotive industries. Large press molds for producing car body parts are made of cast iron. With the increase of automobile production and various changes of design, the press forming process of car body parts has become more difficult. In the case of large press molds, high hardness and abrasive resistance are needed. To overcome these problems, we attempted to develop a combined heat treatment process consisting of local laser heat treatment followed by plasma nitriding, and evaluated the characteristics of the proposed heat treatment method. From the results of the experiments, it has been shown that the maximum surface hardness is 864 Hv by the laser heat treatment, 953 Hv by the plasma nitriding, and 1,094 Hv by the combined heat treatment. It is anticipated that the suggested combined heat treatment can be used to evaluate the durability of press mold.

Equivalence Ratio Measurements in Gas Spray Using Laser Raman Scattering (Laser Raman Scattering을 이용한 가스 분무내 당량비 계측에 관한 연구)

  • Jin, S.H.;Park, K.S.;Song, J.I.;Kim, G.S.
    • Journal of ILASS-Korea
    • /
    • v.2 no.4
    • /
    • pp.7-14
    • /
    • 1997
  • Laser Raman scattering method has been applied to measure equivalence ratio of methane/air mixture in injected spray. We used high power KrF excimer laser$(\lambda=248nm)$ and a high gain ICCD camera to capture low intensity signal. Raman shifts and Raman scattering cross -sections of $H_2,\;O_2,\;N_2,\;CO_2,\;CH_4\;and\;C_3H_8$ are measured precisely. Our results show an excellent agreement with those of other groups. Mole fraction measurement of $O_2\;and\;N_2$ from air shows that $O_2:N_2=0.206:0.794$. We used gas injector which was operated at 1 bar. Methane is used as a fuel. Spray region is $10mm\times37mm$ and this region is divided into 80 points. In Raman signals are obtained and ensemble averaged for each point. 3-d and contour plot of distribution of equuivalence ratio is presented. Our measured results show that the equivalence ratio of methane/air mixture in methane-rich region is reasonable. However, more study is necessary for methane-lean region because background noise level is almost same as Raman intensity of methane.

  • PDF

Fundamentals and Research Trend of Laser Acupuncture (레이저침의 원리와 연구동향 분석)

  • Kim, Hyun-Ho;Nam, Dong-Woo;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.26 no.6
    • /
    • pp.21-30
    • /
    • 2009
  • Objectives : Being introduced in the 1980s, laser acupuncture studies have been steadily carried on such as its thermal effects on human body. However, the mechanisms of effect are not yet clearly explained. Generally, laser acupuncture could be favorable for pediatric patients or people under special conditions (hemophilia, needle-phobia, pathogen-carriers, etc.) because of lower risk of infection, bleeding, pain or fainting. But there are still problems for using laser acupuncture equivalently as the traditional metal needle. The goal of this study is to review the fundamentals, history and present trend of laser acupuncture study, and to suggest how to develop laser acupuncture as an oriental medical device. Method : We performed literature search using PubMed(http://www.ncbi.nlm.nih.gov/pubmed) and Scopus(http://www.scopus.com). Search conditions are laser acupuncture, laser needle, LLLT(as title or abstract) or Litscher G(as author). Main target studies are physical fundamentals, clinical trials, physiological results and device proposals. Results : Many research have shown the similarities of laser acupuncture and traditional metal acupuncture and have reported clinical and physiological effects of laser acupuncture. But, still laser acupuncture is not widely used in Korea due to high-cost of equipments and the lack of clear understanding of laser devices. Additionally, there are still challenges in standardization and device development. Conclusions : Frequencies, laser modes, waveguides, adaptor types, polarization and signal modulations are suggested as future study subjects on laser acupuncture. More various studies and efforts for device development have to be performed to provide oriental medical doctors with evidence based confidence about usage of laser acupuncture.

  • PDF

A Highlight on Reasons for Tattoo Regrets and Removal

  • Rivera, Fabian Perez
    • Medical Lasers
    • /
    • v.10 no.2
    • /
    • pp.106-110
    • /
    • 2021
  • Background and Objectives As the popularity of tattooing has increased, the number of people regretting their tattoos, and therefore seeking tattoo removal services has also increased. This study aimed to highlight the reasons for tattoo regrets. We explore herein, the reasons for seeking tattoo removal at a specialized laser center in South America. Materials and Methods This is a retrospective study of over 757 surveys, including patients who sought tattoo removal services between August 2017 and February 2020. The surveys were conducted using questionnaires which were sent to the patients through email and WhatsApp messages. Results Sixty percent of the patients seeking tattoo erasing services were women (α=0.001), an average of 30 years, with a high educational level (46.6% of them were university or tertiary). Most of the tattoos (89%) had a professional origin, 60% were done with black color and 65% were in exposed areas. More than half of the patients (51%) gave dissatisfaction as the main reason for erasing their tattoos. More than half of patients (51.2%) regretted their tattoos between the same day of being tattooed and five years later. Conclusion In the present study, in South America, tattoo regrets were mostly common among educated (university or tertiary level) women in their 30s. The most preferred color for a tattoo was black. Exposed areas, especially the arms, were preferred more than the covered areas. Most of the participants regretted their tattoos within five years of being tattooed.

Laser Power Beaming Based Wireless Power Transmission System for Multiple Charging of Long-distance Located Electric Vehicle (원거리 전기 자동차의 다중 충전을 위한 레이저 파워 빔 기반의 무선 전력 전송 시스템)

  • Eom, Jeongsook;Kim, Gunzung;Choi, Jeonghee;Park, Yongwan
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.6
    • /
    • pp.379-392
    • /
    • 2016
  • This paper presents the design and simulation of a laser power beaming (LPB) system for an electric vehicle that establishes an optimal power transmission path based on the received signal strength. The LPB system is possible to transfer power from multiple transmitters to a single receiver according to the characteristics of the laser and the solar panel. When the laser beams of multiple transmitters aim at a solar panel at the same time, the received power is the sum of all energy at a solar panel. Our proposed LPB system consists of multiple transmitters and multiple receivers. The transmitter sends its power characteristics as optically coded pulses with a class 1 laser beam and powers as a high-intensity laser beam. By using the attenuated power level, the receiver can estimate the maximum receivable powers from the transmitters and select optimal transmitters. Throughout the simulation, we verified the possibility that different LPB receivers were achieved their required power by the optimal allocation of the transmitter among the various transmitters.

Antifuse Circuits and Their Applicatoins to Post-Package of DRAMs

  • Wee, Jae-Kyung;Kook, Jeong-Hoon;Kim, Se-Jun;Hong, Sang-Hoon;Ahn, Jin-Hong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.216-231
    • /
    • 2001
  • Several methods for improving device yields and characteristics have been studied by IC manufacturers, as the options for programming components become diversified through the introduction of novel processes. Especially, the sequential repair steps on wafer level and package level are essentially required in DRAMs to improve the yield. Several repair methods for DRAMs are reviewed in this paper. They include the optical methods (laser-fuse, laser-antifuse) and the electrical methods (electrical-fuse, ONO-antifuse). Theses methods can also be categorized into the wafer-level(on wafer) and the package-level(post-package) repair methods. Although the wafer-level laser-fuse repair method is the most widely used up to now, the package-level antifuse repair method is becoming an essential auxiliary technique for its advantage in terms of cost and design efficiency. The advantages of the package-level antifuse method are discussed in this paper with the measured data of manufactured devices. With devices based on several processes, it was verified that the antifuse repair method can improve the net yield by more than 2%~3%. Finally, as an illustration of the usefulness of the package-level antifuse repair method, the repair method was applied to the replica delay circuit of DLL to get the decrease of clock skew from 55ps to 9ps.

  • PDF

An obstacle avoidance system of an unmanned aerial vehicle using a laser range finder

  • Kim, Hyun;Miwa, Masafumi;Shim, Joonhwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.7
    • /
    • pp.737-742
    • /
    • 2013
  • Recently, unmanned aircrafts for safe measurement in hazardous locations have been developed. In a method of operation of unmanned aircraft vehicles (UAV), there are two methods of manual control and automatic control. Small UAVs are used for low altitude surveillance flights where unknown obstacles can be encountered. Obstacle avoidance is one of the most challenging tasks which the UAV has to perform with high level of accuracy. In this study, we used a laser range finder as an obstacle detector in automatic navigation of unmanned aircraft to patrol the destination automatically. We proposed a system to avoid obstacles automatically by measuring the angle and distance of the obstacle using the laser range finder.