• 제목/요약/키워드: High heat input

검색결과 361건 처리시간 0.033초

좁은 공간 내의 밀폐형 장치 냉각시스템에 대한 열평형 평가 (Evaluation of Heat Balance for Cooling System of an Armored Installation in Small Space)

  • 김성광;안석환;남기우
    • 한국해양공학회지
    • /
    • 제21권3호
    • /
    • pp.1-7
    • /
    • 2007
  • In this study, the heat balance test of an engine was conducted, and the heat released to coolant is measured and corrected using a power adjustment factor for high fuel temperature to simulate heat rejection of the engine. An engine-converter matching simulation program which can compute the engine speed, transmission output speed, transmission input and output power is developed from the vehicle, transmission and engine performance curve. With this information and the engine heat rejection characteristics, the engine and transmission heat rejection rates can be determined at given condition. In analyzing the air mass flow, a sub program computing the air mass flow rate from the equation of the pressure balance between cooling fan static pressure rise and pressure losses of cooling components is developed.

열원 입력과 비드 생성 방법이 원통형 다층 금속 용접 과정의 유한요소해석에 미치는 영향 (Effects of Heat Input and Bead Generation Methods on Finite Element Analysis of Cylindrical Multi-Pass Welding Process of Metals)

  • 박원동;반치범;김지훈
    • 대한기계학회논문집A
    • /
    • 제41권6호
    • /
    • pp.455-467
    • /
    • 2017
  • 본 논문에서는 원통형 다층 이종 금속 용접부를 대상으로 유한요소 해석을 수행하여, 열원 입력 방법과 용접 비드 생성 방법이 용접 잔류 응력 분포에 미치는 영향을 고려하였다. 열원 입력 방법은 열속 입력 방법과 온도 경계조건 입력 방법으로 나누어 비교하였고, 용접 비드 생성 방법은 요소망 생성 방법과 평온 요소망 방법으로 나누어 비교하였다. 두 열원 입력 방법에 따른 열 해석 결과는 차이가 있었으나, 응력 해석 결과는 유사하였다. 이것은 고온(약 $1000^{\circ}C$ 이상)에 노출되었던 영역이 비슷하고, 고온에서 재료의 강도가 매우 낮아 용접 비드의 온도가 용접잔류응력에 미치는 영향이 미미하기 때문이다. 두 용접 비드 생성 방법의 용접 잔류응력 분포는 유사하였지만 요소망 생성 방법 적용 시 용접 비드 경계에서 겹침과 들뜸이 발생하였다. 대변형이 발생하는 모델의 용접부 형상을 정확하게 모사하기 위해서는 평온요소망이 더 적합하다고 판단된다.

금형재료용 주철의 다이오드 레이저 표면경화처리에 관한 연구(II) - 표면경화의 적용 부위에 따른 열처리 특성의 차이 - (A Study on the Diode Laser Surface Hardening Treatment of Cast Iron for Die Material(II) -Comparison of Hardening Characteristics by the Parts Applied Heat Treatment-)

  • 김종도;송무근;황현태
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1048-1054
    • /
    • 2011
  • 레이저 표면경화처리는 고밀도 에너지 열원에 의해 레이저 조사부위만 급속 가열한 후 표면의 열이 내부로 전도되어 급속히 자기냉각 됨으로써 표면을 경화시키는 방법이다. 이 표면처리 방법은 열처리에 의한 열변형이 거의 없고, 표면경화처리 이후 다른 공정을 수반하지 않는다. 또한 국부적인 가공이 가능하기 때문에 복잡한 형상을 가지는 금형에는 적합한 표면처리 방법이다. 본 연구에서는 열처리에 적합한 빔 프로파일을 가진 고출력 다이오드 레이저를 이용하여 금형재료용 주철의 표면처리를 실시하였다. 프레스 금형 공정에 따른 금형의 형상이 다르기 때문에 적용부위에 따라 시험편을 평면과 모서리부로 나누어 열처리를 실시하였다. 이때 모서리부의 열처리는 광학헤드를 $10^{\circ}$ 기울인 상태에서 진행하였다. 그 결과, 모서리부의 열처리는 평면부와 비교하여 형상에 따른 열전달 루트가 제한되므로, 입열이 집중되기 쉬워 평면 열처리보다 빠른 이송속도에서 경화가 이루어졌다.

Development of Heat Wave Indices for Korean Peninsula

  • Chandrasekara, Sewwandhi S.K.;Kwon, Hyun-Han
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2020년도 학술발표회
    • /
    • pp.366-366
    • /
    • 2020
  • The drought is one of the extreme natural disasters observed in any climate zone and it is due to the deficiency in moisture. The flash drought is identified recently as a subdivision of drought and it is an extreme event distinguished by sudden onset and rapid intensification of drought conditions with severe impacts. The main cause for the flash drought is coupled situation due to precipitation deficit and high evapotranspiration. Hence, heat waves plays major role in identification of flash drought. Therefore, this study focused on identifying changes in distribution of heat waves for Korean Peninsula. The daily maximum and minimum temperature data were used in this study. The heat wave, heat wave intensity and heat wave intensity index were derived. The results of the study would be an input for the future studies on identification of flash drought in Korean Peninsula.

  • PDF

터널 화재시나리오에 따른 콘크리트 PC패널 라이닝의 전열특성에 관한 해석적 연구 (An Study on Heat Transfer Analysis to Concrete PC Pannel Lining under Tunnel Fire Scenario)

  • 김형준;김흥열;박경훈;신현준
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.487-492
    • /
    • 2009
  • This study was performed FE numerical analysis under 120-minute fire conditions, using the ABAQUS, a wide use software, on the basis of the test results by concrete tunnel lining fire strengths (ISO, RWS, and MHC). The concrete material test was to secure the material properties of concrete linings, which were numerical analysis input conditions. And then built the material properties, such as specific heat, heat transfer rate, heat expansion rate, density, elasticity coefficient and compression strength under high temperature conditions, as database at 20 $^{\circ}C$ to 800 $^{\circ}C$, applying them to analysis as input values. As a result, the tunnel linings under RWS fire conditions saw fire temperature rose to maximum 1119 $^{\circ}C$at the location of 5 mm above a thermal surface, and saw surface temperature amount to 1214 $^{\circ}C$ in the middle part.

  • PDF

Performance Comparison of Liquid-Cooling with Air-Cooling Heat Exchangers Designed for Telecommunication Equipment

  • Jeon, Jong-Ug;Choi, Jong-Min;Heo, Jae-Hyeok;Kang, Hoon;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권2호
    • /
    • pp.64-69
    • /
    • 2008
  • Electronic and telecommunication industries are constantly striving towards miniaturization of electronic devices. Miniaturization of chips creates extra space on PCBs that can be populated with additional components, which decreases the heat transfer surface area and generates very high heat flux. Even though an air-cooling technology for telecommunication equipment has been developed in accordance with rapid growth in electrical industry, it is confronted with the limitation of cooling capacity due to the rapid increase of heat density. In this study, liquid-cooling heat exchangers were designed and tested by varying geometry and operating conditions. In addition, air-cooling heat exchangers were tested to provide performance data for the comparison with the liquid-cooling heat exchangers. The liquid-cooling heat exchangers had twelve rectangular channels with different flow paths of 1, 2, and 12. Silicon rubber heaters were used to control the heat load to the heat exchangers. Heat input ranged from 293 to 800W, and inlet temperatures of working fluid varied from 15 to $27^{\circ}C$. The heat transfer coefficients were strongly affected by flow conditions. All liquid-cooling heat exchangers showed higher cooling performance than the air-cooling heat exchanger. The heat exchanger with 2-paths could provide more controllability on the maximum temperature than the others.

Two-dimensional Numerical Simulation of a Pulsed Heat Source High Temperature Inert Gas Plasma MHD Electrical Power Generator

  • Matsumoto, Masaharu;Murakami, Tomoyuki;Okuno, Yoshihiro
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.589-596
    • /
    • 2008
  • Performance of a pulsed heat source high temperature inert gas plasma MHD electrical power generator, which can be one of the candidates of space-based laser-to-electrical power converter, is examined by a time dependent two dimensional numerical simulation. In the present MHD generator, the inert gas is assumed to be ideally heated to about $10^4K$ pulsed-likely within short time(${\sim}1{\mu}s$) in a stagnant energy input volume, and the energy of high temperature inert gas is converted to the electricity with the medium of pure inert gas plasma without seeding. The numerical simulation results show that an enthalpy extraction ratio(=electrical output energy/pulsed heat energy) of several tens of % can be achieved, which is the same level as the conventional seeded non-equilibrium plasma MHD generator. Although there still exist many phenomena to be clarified and many problems to be overcome in order to realize the system, the pulsed heat source high temperature inert gas MHD generator is surely worth examining in more detail.

  • PDF

고출력 연속파형 Nd:YAG 레이저를 이용한 CSP 1N 냉연강판 절단시 절단공정변수의 절단폭에 미치는 영향 (Influence of process parameters on the kerfwidth for the case of laser cutting of CSP 1N sheet using high power CW Nd:YAG laser)

  • 안동규;김민수;이상훈;박형준;유영태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.910-915
    • /
    • 2004
  • The objective of this study is to investigate the influence of process parameters, such as power of laser, travel speed of laser and material thickness, on the practical cutting region and the kerfwidth for the case of cutting of CSP 1N sheet using high power Nd:YAG laser with continuous wave(CW). In order to find the practical cutting region and the relationship between process parameters on the kerfwidth, several laser cutting experiments are carried out. The effective heat input is introduced to consider the influence of power and travel speed of laser on the kerfwidth together. From the results of experiments, the allowable cutting region and the relationship between the effective heat input and kerfwidth for the case of cutting of CSP 1N sheet using high power CW Nd:YAG laser have been obtained to improve the dimensional accuracy of the cut area.

  • PDF

마이크로 캡슐 잠열재 슬러리를 적용한 미소채널 열교환기의 열분배 성능평가 (Experimental Study on the Heat Distribution in the Rectangular Mini Channel Heat Exchangers with MPCM Slurry)

  • 전종욱;백창현;김용찬;김영득;최종민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.645-650
    • /
    • 2006
  • The heat transfer performance and energy transport ability are relatively high due to higher specific heat. Therefore, it can be used in fields such as heating, ventilating, air-conditioning, refrigeration and heat exchangers. In this study, liquid-cooling heat exchangers were designed and tested by varying geometry and operating conditions. In addition, liquid-cooling heat exchangers were tested to provide performance data for MPCM slurry. The liquid-cooling heat exchangers had twelve rectangular channels with flow paths of 1, 2, 4 and 12. Silicon rubber heaters were used to control the heat load to the heat exchanger. Heat input ranged from 293 to 800 W, and inlet temperatures of working fluid varied from 15S to $27^{\circ}C$. The standard deviation of surface temperature was strongly affected by the coolant of MPCM Slurry, All MPCM-cooling heat exchangers showed higher cooling performance than the water-cooling heat exchanger except one path channel heat exchanger.

  • PDF

냉.온열 동시 제조시스템의 성능분석(I)-Simulation (Performance Analysis of Simultaneous Heating & Cooling Water Making System(I)-Simulation)

  • 박성룡;박준택;안영훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.266-271
    • /
    • 2001
  • In this study, the performance of the simultaneous heating & cooling water making system using R134a was investigated by simulation. The most important effect upon heating COP was intermediate pressure depending on input water temperature. With the input water temperature of $10^{\circ}C\;and\;20^{\circ}C$, optimum intermediate pressure were 923 and 1040kPa, respectively. At that optimum intermediate pressure, the maximum heating COP of the system operated between $0^{\circ}C$ evaporating temperature and $70^{\circ}C$ condensing temperature were 4.15 and 3.83. With installation of the subcoolers in high or low pressure section, the system COP was increased by reducing the refrigerant mass flow rate. Under the optimum pressure and $10^{\circ}C$ input water temperature, it was found that heating COP was maximized when the low-subcooler and high-subcooler capacity rate were taken by 14% and 13%, respectively.

  • PDF