• Title/Summary/Keyword: High heat emission

Search Result 303, Processing Time 0.025 seconds

Experimental Studies on Joinability of SWS 490A High Tension Steel using Acoustic Emission Signals (음향방출 신호를 이용한 SWS 490A 고장력강의 접합성 평가에 대한 실험적 연구)

  • Rhee Zhang-Kyu;Woo Chang-Ki
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.3
    • /
    • pp.87-95
    • /
    • 2005
  • The object of this study is to investigate the effect of joinability by using acoustic emission(AE) signals and doing a pattern recognition for weld heat affected zone(HAZ) in tensile testing. This study was carried out an SWS 490A high tension steel for electric shielded metal arc welding(SMAW), $CO_2$ gas arc welding and TIG welding. And correspondingly, the root openings are 3, 4 and 2.8mm. The results of the tensile test of weld HAZ come out electric shield arc welding $>\;CO_2$ gas arc welding > TIG welding in case of single welding. It is believed that this is a phenomenon where difference of its root opening or base metal thickness. Also, the technique of AE is ideally suited to study variables which control time and stress dependent fracture or damage process in metallic materials.

Experimental Studies on Joinability of SWS 490A High Tension Steel using Acoustic Emission Signals (음향방출 신호를 이용한 SWS 490A 고장력강의 접합성 평가에 대한 실험적 연구)

  • 이장규;우창기;윤종희;조진호;조대희;박성완;김봉각;구영덕
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.40-48
    • /
    • 2004
  • The object of this study is to investigate the effect of joinability by using acoustic emission (AE) signals and doing a pattern recognition for weld heat affected zone (HAZ) in tensile testing. This study was carried out an SWS 490A high tension steel for electric shielded metal arc welding (SMAW), $CO_2$ gas arc welding and TIG welding. And correspondingly, the root openings are 3, 4 and 2.8mm. The results of the tensile test of weld HAZ come out electric shield arc welding > $CO_2$ gas arc welding > TIG welding in case of single welding. It is believed that this is a phenomenon where difference of its root opening or base metal thickness. Also, the technique of AE is ideally suited to study variables which control time and stress dependent fracture or damage process in metallic materials.

  • PDF

Low Power Design on Heater and Cathode of Electron Gun for High Resolution CRT (고해상도 CRT용 전자총의 히터 및 캐소드 저전력 설계)

  • Kim Hack-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.618-625
    • /
    • 2005
  • This paper has achieved that an optimal design and experiments of heater and cathode of electron gun that serve to embody high current density in CRT display. For the high brightness, high resolution and larger size in CRT display, high current density of electron gun is indispensible. An Impregnation style cathode is used, and must heighten operating temperature of heater to get high current density for this, it is proportional hereupon and power dissipation increases. In this paper, to get low power cathode with high current density, There are produced and tested sample that differ lead type of heater, coating method, the pitch and number of winding of the first and second coiling in the heat emission area for the low power design of high current density cathode heater in this paper.

The Evaluation of Mixed Welded SM 490A Steel by Acoustic Emission (2) (음향방출법에 의한 SM 490A 강의 복합용접성 평가 (2))

  • 이장규;우창기;김봉각;윤종희;인승현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.363-370
    • /
    • 2003
  • The object of this study is to investigate the effect of compounded welding by using an acoustic emission (AE) signals and doing a source location for weld heat affected zone (HAZ) through tensile testing. This study was carried out a SM 490A high tension steel for electronic shielded metal arc welding (SMAW), $CO_2$ gas arc welding and TIG welding. Data displays are based on the measured parameters of the AE signals, along with environmental variables such as time and load. These history plots are displays showing the chronological course of the test. Also, source location gives the X- and Y-coordinates of the AE source.

  • PDF

Development of Pre-heat-treated High Strength CHQ Wires and Forming Technology for them (고강도 냉간압조용 선조철강 및 제품화 기술 개발)

  • Yoon, D.J.;Kim, E.Z.;Ahn, S.T.;Son, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.35-36
    • /
    • 2009
  • Development trend and current status were surveyed for pre-heat-treated high strength cold heading quality (CHQ) wire and it's forming technology. Spheroidizing, quenching, and tempering heat treatments are eliminated by adapting the pre-treated wire, which could reduce energy consumption rate and green house gas emission rate during produce parts requiring high strength. There are some challenging problems to expand application area such as enhancing forming tool life, and preventing delayed failure. Domestic research movement concerning the development and application of the new high strength wire was introduced.

  • PDF

A Study on Friction Welding and AE Evaluation for Cold Die Steel and High Temperature Creep Properties (금형강의 마찰용접과 AE평가 및 고온 크리프 특성에 관한 연구)

  • 황성필;김일석;유인종;이연탁;오세규
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.282-288
    • /
    • 2001
  • This paper deals with determining the proper friction welding condition and analyzing various mechanical properties of friction welded joints of the bladepart heat resisting steel(STD11) for cold die punch to the shank part alloy steel(SCM440). And the in-process real-time weld quality evaluation technique by acoustic emission during friction welding of STD11 to SCM440 steels with higher confidence and reliability has been much required even though it might be the first trial approach for developing it. Also, the high temperature properties of STD11-SCM440 weld were considered in this paper.

  • PDF

Study on Optimization of Dissimilar Friction Welding of Nuclear Power Plant Materials and Its Real Time AE Evaluation (원자력 발전소용 이종재 마찰용접의 최적화와 AE에 의한 실시간 평가에 관한 연구)

  • 권상우;오세규;유인종;황성필;공유식
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.42-46
    • /
    • 2000
  • In this paper, joints of Cu-1Cr-0.1Zr alloy to STS316L were performed by friction welding method. Cu-1Cr-0.1Zr alloy is attractive candidate as nuclear power plant material and exibit the best combination of high sts good electrical and thermal conductivity of any copper alloy examined. The stainless steel is a structural material who alloy acts as a heat sink material for the surface heat flux in the first wall. So, in this paper, not only the develop optimizing of friction welding with more reliability and more applicabililty but also the development of in-process rear quility(such as strength and toughness) evaluation technique by acoustic emission for friction welding of such nuclear component of Cu-1Cr-0.1Zr alloy to STS316L steel were performed.

  • PDF

Numerical Analysis on Radiative Heating of a Plume Base in Liquid Rocket Engine (플룸에 의한 액체로켓 저부면 복사 가열 해석)

  • Sohn C. H.;Kim Y. M.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1999.11a
    • /
    • pp.65-70
    • /
    • 1999
  • Radiative heating of a liquid rocket base plane due to plume emission is numerically investigated. Calculation of flow and temperature fields around rocket nozzle precedes and thereby realistic plume shape and temperature distribution inside the plume are obtained. Based on the calculated temperature field, radiative transfer equation is solved by discrete ordinate method. The averaged radiative heat flux reaching the base plane is about $5kW/m^2$ at the flight altitude of 10.9km. This value is small compared with radiative heat flux caused by constant-temperature (1500K) plume emission, but it is not negligibly small. At higher altitude (29.8km), view factor between the babe plane and the exhaust plume is increased due to the increased expansion angle of the plume. Nevertheless, the radiative heating disappears since the base plane is heated to high temperature (above 1000K) due to convective heat transfer.

  • PDF

Correlation Analysis of the Thermal Conductivity Heat Flow Meter and MTPS (Modified Transient Plane Source) Method Using Wood Flooring and Wall Materials (목질마루바닥재와 벽체용 재료를 이용한 평판열류계법과 MTPS (Modified Transient Plane Source)법의 열전도율 상관관계 분석)

  • Cha, Jung-Hoon;Seo, Jung-Ki;Kim, Su-Min
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.2
    • /
    • pp.118-125
    • /
    • 2011
  • These days global warming is the most important problem and the most important factor is high emission of carbon dioxide. The 23% of carbon dioxide emission for building construction must be reduced. Thermal conductivity is the most basic factor that can decrease the energy consumption especially insulation. Therefore, an accurate and continuous thermal conductivity measurement can be a way to save energy. In this paper, there are methods about how to investigate thermal conductivity measurements and comparing two methods which are the Heat Flow Meter 436 and TCi.

  • PDF

Modeling of transient temperature distribution in multilayer asphalt pavement

  • Teltayev, Bagdat B.;Aitbayev, Koblanbek
    • Geomechanics and Engineering
    • /
    • v.8 no.2
    • /
    • pp.133-152
    • /
    • 2015
  • Mathematical model has been developed for determination of temperature field in multilayer pavement and subgrade, which considers transfer of heat by conduction and convection, receiving of heat from total solar radiation and atmosphere emission, output of heat due to the emission from the surface of pavement. The developed model has been realized by the finite element method for two dimensional problem using two dimensional second order finite element. Calculations for temperature field have been made with the programme realized on the standard mathematical package MATLAB. Accuracy of the developed model has been evaluated by comparison of temperatures, obtained theoretically and experimentally. The results of comparison showed high accuracy of the model. Long-term calculation (within three months) has been made in pavement points in accordance with the data of meteorological station for air temperature. Some regularities have been determined for variation of temperature field.