• Title/Summary/Keyword: High energy radiation

Search Result 1,350, Processing Time 0.022 seconds

MEVVA ion Source And Filtered Thin-Film Deposition System

  • Liu, A.D.;Zhang, H.X.;Zhang, T.H.;Zhang, X.Y.;Wu, X.Y.;Zhang, S.J.;Li, Q.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.6 no.2
    • /
    • pp.55-57
    • /
    • 2002
  • Metal-vapor-vacuum-arc ion source is an ideal source for both high current metal ion implanter and high current plasma thin-film deposition systems. It uses the direct evaporation of metal from surface of cathode by vacuum arc to produce a very high flux of ion plasmas. The MEVVA ion source, the high-current metal-ion implanter and high-current magnetic-field-filtered plasma thin-film deposition systems developed in Beijing Normal University are introduced in this paper.

  • PDF

DEVELOPMENT OF NUCLEAR ENERGY AND RADIATION TEXTBOOKS FOR ELEMENTARY, MIDDLE, AND HIGH SCHOOL STUDENTS

  • Han, Eun Ok;Kim, Jae Rok;Choi, Yoon Seok;Lochhead, James
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.132-146
    • /
    • 2015
  • To develop tailored elementary, middle, and high school textbooks suitable for understanding the nuclear energy and radiation, quantitative and qualitative research was carried out in parallel, which included nine steps to ensure the validity of content and structure. The elementary, middle, and high school students wanted to acquire information used in their daily lives, including the definition of nuclear energy and radiation, principles and status of nuclear power generation, and information about irradiated food, medical radiation, and radiation in life. In the evaluation of the effects of textbook contents according to the educational requirements of each school level, high suitability frequencies (>80%) were shown for the human character, education goals, curriculum goals, evaluation method, and education time. At some levels, the high suitability frequencies (>70%) were shown for the education grade, education type, and textbook type.

Gene Expression Profiles Following High-Dose Exposure to Gamma Radiation in Salmonella enterica serovar Typhimurium

  • Lim, Sangyong;Jung, Sunwook;Joe, Minho;Kim, Dongho
    • Journal of Radiation Industry
    • /
    • v.2 no.3
    • /
    • pp.111-119
    • /
    • 2008
  • Microarrays can measure the expression of thousands of genes to identify the changes in expression between different biological states. To survey the change of whole Salmonella genes after a relatively high dose of gamma radiation (1 kGy), transcriptome dynamics were examined in the cells by using DNA microarrays. At least 75 genes were induced and 89 genes were reduced two-fold or more after irradiation. Several genes located in pSLT plasmid, cyo operon, and Gifsy prophage were induced along with many genes encoding uncharacterized proteins.While, the expression of genes involved in the virulence of Salmonella as well as metabolic functions were decreased. Although the radiation response as a whole could not be illustrated by using DNA microarrays, the data suggest that the response to high dose of irradiation might be more complex than the SOS response.

Proteome Analysis of Escherichia coli after High-dose Radiation

  • Lim, Sangyong;Lee, Misong;Joe, Minho;Song, Hyunpa;Kim, Dongho
    • Journal of Radiation Industry
    • /
    • v.5 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Since proteomics can be employed to compare changes in the expression levels of many proteins under particular genetic and environmental conditions, using mass spectrometry to establish radiation stimulon, we performed two-dimensional gel electrophoresis and identified E. coli proteins whose expressions are affected by high dose of ionizing radiation. After exposure to 3 kGy, it was found that 6 proteins involved in carbon and energy metabolism were reduced. Although 4 of 7 protein spots showing a significant increase in expression level were neither identified nor classified, uridine phosphorylase (Udp), superoxide dismutase (SodB), and thioredoxin-dependent thiol peroxidase (Bcp) were proven to be up-regulated after irradiation. This suggests that E. coli subjected to high doses of radiation (3 kGy) may operate a defense system that is able to detoxify reactive oxygen species and stimulate the salvage pathway of nucleotide synthesis to replenish damaged DNA.

Comparison of Environmental Radiation Survey Analysis Results in a High Dose Rate Environment Using CZT, NaI(Tl), and LaBr3(Ce) Detectors

  • Sungyeop Joung;Wanook Ji;Eunjung Lee;Young-Yong Ji;Yoomi Choi
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.4
    • /
    • pp.543-558
    • /
    • 2023
  • Currently, Japan is undertaking a nationwide project to measure and map radioactive contamination around Fukushima, as part of the efforts to restore normalcy following the nuclear accident. The Japan Atomic Energy Agency (JAEA) manages the Fukushima Environmental Safety Center, located approximately 20 km north of the Fukushima Daiichi nuclear power plant in Minamisōma City, Fukushima Prefecture. In collaboration with the JAEA, this study involved conducting comparison experiments and analyses with radiation detectors in high radiation environments, a challenging task in Korean environments. Environmental radiation surveys were conducted using three types of detectors: CZT, NaI(Tl), and LaBr3(Ce), across two contaminated areas. Dose rate values were converted using dose rate conversion factors for each detector type, and dose rate maps were subsequently created and compared. The detectors yielded similar results, demonstrating their feasibility and reliability in high radiation environments. The findings of this study are expected to be a crucial reference for enhancing the verification and supplementation of procedures and methods in future radiation measurements and mobile surveys in high-radiation environments, using these three types of radiation instruments.

Current R&D Status of Fuel Cell Membranes by Radiation in Korea (방사선을 이용한 연료전지막 국내 제조 기술 개발 현황)

  • Shin, Junhwa;Sohn, Joon-Yong;Nho, Young-Chang;Kang, Tai-Jin;Kim, Dong-Soo;Im, Don-Sun;Lee, Byoung Hun;Kim, Jae-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.4
    • /
    • pp.289-297
    • /
    • 2012
  • Since Nafion is very expensive and shows the decreased fuel cell performance over $80^{\circ}C$ operating temperature, much work has been carried out in the search for cheaper membrane with high fuel cell performance. Radiation is known to be very useful for the preparation of the polymer electrolyte membranes since it can be effectively used for the introduction of ion conducting functional groups into the commercial film with high mechanical and chemical properties. Here, we summarize the our recent progress in the development of fuel cell membranes by utilizing radiation.

High-energy Photons and Particles in Space Environment

  • Ohno, Shin-ichi
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.170-173
    • /
    • 2002
  • Space is full of energetic events emitting high-energy radiations which may be fatal to all living things unless protected. The present paper briefly describes high-energy photons and particles incident on Earth surface and their common properties toward living things. Role of radiation played in evolution of life and earth environment will be presented.

  • PDF

AN EVALUATION OF RADIATION DOSES RESULTING FROM THE MEDICAL USE OF HIGH-ENERGY BETA-RAY SOURCES

  • Park, Jae-Woo;Kim, Hyun-Jo
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.149-154
    • /
    • 2001
  • Calculational models to evaluate radiation doses resulting from the medical use of high energy beta-ray sources are presented. The radioactive sources considered are Sr-90/Y-90 used as ophthalmic applicator, Re-188 used for treating restenosis of coronary artery, and Ho-166 used for treating hepatic tumors. Typical therapeutic situations which might induce relatively high radiation doses the medical person involved were considered to compute by using MCNP-4C Monte Carlo code the radiation doses. The calculation results suggest that for all of the cases considered, the evaluated radiation doses are negligible compared to the dose limits. It is also found that the effect of Bremsstrahlung radiations on the total dose is insignificant, and hence the conventional lead gown is also effective in shielding beta-rays.

  • PDF

Radiotherapy Technique of High Energy Electron (고에너지 전자선의 방사선 치료 기술)

  • SUH M.W.;PARK J.I.;CHOI H.S.;KIM W.Y.
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 1985
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefore, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed does, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under $3\%$ errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under $5\%$ errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatters; i.e., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

Induction of SOS Genes by a Low Dose of Gamma Radiation, 10 Gy, in Salmonella enterica Serovar Typhimurium

  • Lim, Sangyong;Joe, Minho;Seo, Hoseong;Kim, Dongho
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.109-113
    • /
    • 2013
  • In a previous study, a relatively high dose of gamma radiation (1 kGy) did not fully induce typical SOS genes such as sulA, recA, recN, and din in Salmonella Typhimurium (S. Typhimurium) (Lim et al. 2008, Gene expression profiles following high-dose exposure to gamma radiation in Salmonella enterica serovar Typhimuium. J. Radiat. Ind. 3:111-119). In this study, we examined changes in the transcriptional repertoire of S. Typhimurium after a dose of 10 Gy using DNA microarrays. It was found that more than half (~65%) of the 26 up-regulated genes belong to the SOS regulon: ten genes are typical SOS genes, and seven genes are Salmonella prophage genes, which are known to be activated by LexA cleavage. Among 29 down-regulated genes, the function of five genes with the most decreased expression is associated with carbohydrate transport and energy production. This suggests that upon exposure to gamma radiation cells may cease growing by reducing the metabolic activity, and repair DNA damage using a DNA repair system such as the SOS response system. The difference in expression of the SOS genes between a high (1 kGy) and low (10 Gy) dose of radiation shows the possibility that cells may opt for one of multiple regulatory circuits in response to the specific gamma radiation dose.