• 제목/요약/키워드: High energy photon

검색결과 237건 처리시간 0.029초

POLARITY AND ION RECOMBINATION CORRECTION FACTORS OF A THIMBLE TYPE IONIZATION CHAMBER WITH DEPTH IN WATER IN THE MEGAVOLTAGE BEAMS

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Min, Chul-Hee;Shin, Dong-Oh;Choi, Jin-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.43-48
    • /
    • 2009
  • When the PDD (percentage depth dose) in the megavoltage beams is measured in the water phantom, the polarity and ion recombination effects of ionization chambers with depth in water are not usually taken into consideration. We try to investigate if those variations with depth should be taken into consideration or could be ignored for the thimble type semiflex ionization chamber (PTW $31010^{TM}$, SN 1551). According to the recommendation of IAEA TRS-398, the 4 representative depths of $d_s$, $d_{max}$, $d_{90}$ and $d_{50}$ were used for the electron beams. For the photon beams, the 4 depths were arbitrarily chosen for the photon beams, which were $d_s$, $d_{max}$, $d_{10}$ and $d_{20}$. For the high energy photon beam both polarity and ion recombination factors of the chamber with depth in water gives the good agreements within the maximum $\pm$0.2%, while the $C_{polS}$ with depth came within the maximum $\pm$ 0.4% and the $C_{IRS}$ within the maximum $\pm$0.6% in every electron beam used. This study shows that PDI (percentage depth ionization) could be a good approximation to PDD for the chamber used.

인삼 엽록체의 미세구조와 Photobleaching (Ultrastructural Feature and Photobleaching of ginseng Chloroplasts)

  • 양덕조;김명원
    • Journal of Ginseng Research
    • /
    • 제14권3호
    • /
    • pp.416-420
    • /
    • 1990
  • Ultrastructural and anatomical features of the leaf were studied in Panax ginseng C.A. Meyer(ginseng). The ginseng leaf poorly developed palisade tissue and the size of mesophyll cell was larger and the chloroplast density was lower than that of Glycine max (soyben). Ginseng chloroplast was filled with highly stacked grana and condensely-arrayed thylakoid, so the stroma space was hardly absorbed. However, ginseng mesophyll tissue and chloroplast array did not reduce light energy entering the mesophyll chloroplast, and the high LHCP/CP ratio of ginseng thylakoid resulted in the absorption of excess photon. It is reasonable to assume that 1O1-photogenearation by excess light energy partially resulted from the anatomical and ultrastructural characteristics of the ginseng leaf.

  • PDF

Thermoluminescent Characteristics of Newly Developed LiF:Mg,Cu,Na,Si TL Detectors

  • Lee J. I.;Kim J. L.;Chang S. Y.
    • Nuclear Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.47-52
    • /
    • 2004
  • Recently, a new sintered pellet-type LiF:Mg,Cu,Na,Si TL detector which has a high sensitivity and good reusability, named KLT-300(KAERI LiF:Mg,Cu,Na,Si TL detector), was developed by the variation of the dopants concentrations and the parameters of the preparation procedure at KAERI (Korea Atomic Energy Research Institute). In this study, the thermoluminescent characteristics of the newly developed TL detectors were investigated. The sensitivity of the TL detector was compared with that of the TLD-100 by light integration. The dose linearity of the detector was tested from $10^{-6}$ Gy up to 30 Gy. The dose response was very linear up to 10 Gy and a sublinear response was observed at higher doses. The energy response of the detector was studied for photon energies from 20 keV to 662 keV. The result shows that a maximum response of 1.004 at 53 keV and a minimum response of 0.825 at 20 keV were observed. The reproducibility study for the TL detector was also carried out. The coefficients of variation for each detector separately did not exceed 0.016, and for all the 10 detectors collectively was 0.0054. Lower limit of detection for the detector was investigated at 70 nGy by the Harshaw 4500 TLD Reader and the residual signal of the TL detector was found to be $0.57\%$.

Analysis and Monitoring of Environmental Parameters in a Single-span Greenhouse during Strawberry Cultivation

  • Park, Minjung;Kang, Taegyeong;Yun, Sung-wook;Lim, Ryugap;Son, Jinkwan;Kang, Donghyeon
    • 한국환경과학회지
    • /
    • 제30권11호
    • /
    • pp.907-914
    • /
    • 2021
  • In this study, strawberry cultivation environment in a greenhouse located in Jeonju was monitored and internal environmental parameters were analyzed. Temperature, humidity, RAD, and PPF sensors were installed to monitor environmental conditions in the test greenhouse. Data were collected every 10 minutes during four winter months from sensors placed across the greenhouse to assess its permeability and environmental uniformity. Temperature and humidity inside the greenhouse were relatively uniform with negligible deviations among the center, south, and north; however, it was judged that further analysis of gradients of these parameters from the east to the west of the greenhouse would be needed. Both RAD (Total solar radiation) and PPF (Photosynthetic photon flux) had high values on the south and were low on the north and the reduction rate of these parameters was 54% and 61%, respectively, indicating that a significant amount of light could not be transmitted. This implied a significant decrease in the amount of light entering the greenhouse during winter. Therefore, it is concluded that environmental control devices and auxiliary lighting are needed to achieve uniform greenhouse environment for efficient strawberry cultivation.

Feasibility study of SiPM based scintillation detector for dual-energy X-ray absorptiometry

  • Park, Chanwoo;Song, Hankyeol;Joung, Jinhun;Kim, Yongkwon;Kim, Kyu Bom;Chung, Yong Hyun
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2346-2352
    • /
    • 2020
  • Dual-energy x-ray absorptiometry (DXA) is the noninvasive method to diagnose osteoporosis disease characterized by low bone mass and deterioration of bone tissue. Many global companies and research groups have developed the various DXA detectors using a direct photon-counting detector such as a cadmium zinc telluride (CZT) sensor. However, this approach using CZT sensor has some drawback such as the limitation of scalability by high cost and the loss of efficiency due to the requirement of a thin detector. In this study, a SiPM based DXA system was developed and its performance evaluated experimentally. The DXA detector was composed of a SiPM sensor coupled with a single LYSO scintillation crystal (3 × 3 × 2 ㎣). The prototype DXA detector was mounted on the dedicated front-end circuit consisting of a voltage-sensitive preamplifier, pulse shaping amplifier and constant fraction discriminator (CFD) circuit. The SiPM based DXA detector showed the 34% (at 59 keV) energy resolution with good BMD accuracy. The proposed SiPM based DXA detector showed the performance comparable to the conventional DXA detector based on CZT.

Photon Beam에 대한 Kerma와 흡수선량의 측정 (A Measurement of Kerma and Absorbed Dose in Photon Fields)

  • 김성희;신승애;추성실
    • Journal of Radiation Protection and Research
    • /
    • 제11권1호
    • /
    • pp.77-82
    • /
    • 1986
  • Kerma와 흡수선량 사이의 관계를 결정하는 것은 선량측정의 기본적인 문제이다. 본 연구에서는 고에너지 치료용 선형가속기의 6MV X-선과 감마치료기의 $^{60}Co$에 대한 kerma와 흡수선량을 측정하였다. 본 실험결과는 $^{60}Co$감마선에 의한 물과 알루미늄의 과도 평형 영역에서의 흡수선량이 실제적으로 kerma와 일치하였으며, 최대선량 깊이는 6MV와 $^{60}Co$에서 각각 $1.45g/cm^2$$0.48g/cm^2$이었다. 최대 build-up에서의 흡수선량과 표면에서의 충돌 kerma의 비($K^{att}$)는 표준 조사면에서 물과 알루미늄에 대해, 6MV인 경우는 0.949, $^{60}Co$인 경우는 0.992이었다. 이 결과는 $K^{att}$의 물질에 대한 의존성이 매우 작음을 보여준다.

  • PDF

Properties of Pulsed Photostimulated Luminescence and Thermoluminescence for Detection of Gamma-Irradiated Teas during Storage

  • Kausar, Tusneem;Kim, Byeong-Keun;Yang, Jae-Seung;Byun, Myung-Woo;Kwon, Joong-Ho
    • Preventive Nutrition and Food Science
    • /
    • 제9권3호
    • /
    • pp.227-231
    • /
    • 2004
  • Green, black and oolong teas were irradiated by $^{60}$ Co-gamma rays (0~10 kGy) and were investigated for detection of irradiation treatment using pulsed photostimulated luminescence (PPSL) and thermoluminescence (TL) during storage. Teas irradiated at 2.5 kGy or more showed a photon count of greater than 5000 counts/60 sec while the non-irradiated yielded only 650~1000 count/60 sec. Correlation coefficients between irradiation dose and photon counts/60 sec were 0.8951, 0.7934 and 0.9007 for green, black and oolong teas, respectively. The TL glow curves for minerals isolated from the non-irradiated teas were situated at about 30$0^{\circ}C$ with a low intensity, but for irradiated samples were approximately 15$0^{\circ}C$ with a high intensity. The TL ratios (TL$_1$/TL$_2$), calculated from values after initial radiation and then after re-irradiation of the teas, were below 0.1 for the non-irradiated samples and higher than 1.44 for all irradiated samples, enhanced the reliability of the identification results for TL. The signal intensity of PPSL and TL for irradiated teas decreased with the lapse of post-irradiation storage time at room temperature but was still distinguishable from that of the non-irradiated samples even after one year.

X선치료 조사야 내 공동의 존재에 따른 선량분포의 측정 (The Influence of Air Cavity on Interface Doses for Photon Beams)

  • 정세영;김영범;권영호;김유현
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.69-77
    • /
    • 1998
  • When a high energy photon beam is used to treat lesions located in the upper respiratory air passages or in maxillary sinus, the beams often must traverse an air cavity before it reaches the lesion. Because of this traversal of air, it is not clear that the surface layers of the lesion forming the air-tumor tissue interface will be in a state of near electronic equilibrium; if they are not, underdosing of these layers could result. Although dose corrections at large distances beyond an air cavity are accountable by attenuation differences, perturbations at air-tissue interfaces are complex to measure or calculate. This problem has been investigated for 4MV and 10MV X-ray beams which are becoming widely available for radiotherapy with linear accelerator. Markus chamber was used for measurement with variouse air cavity geometries in X-ray beams. Underdosing effects occur at both the distal and proximal air cavity interface. The magnitude depended on geometry, energy, field sizes and distance from the air-tissue interfaces. As the cavity thickness increased, the central axis dose at the distal interface decreased. Increasing field size remedied the underdosing, as did the introduction of lateral walls. Fellowing a $20{\times}2{\times}2\;cm^3$\;air\;cavity,\;4{\times}4\;cm\;field\;there\;was\;an\;11.5\%\;and\;13\%\;underdose\;at\;the\;distal\;interface,\;while\;a\;20{\times}20{\times}2\;cm^3\;air\;cavity\;yielded\;a\;24\%\;and\;29\%$ loss for the 4MV and 10MV beams, respectively. The losses were slightly larger for the 10MV beams. The measurements reported here can be used to guide the development of new calculation models under non-equilibrium conditions. This situation is of clinical concern when lesions such as larynx and maxillary carcinoma beyond air cavities are irradiated.

  • PDF

Erbium 도핑된 p-GaSe 단결정의 홀 효과 특성 (Hall-effect properties of single crystal semiconductor P-GaSe dopes with $Er^{3+}$)

  • 이우선;오금곤;정용호;정창수;손경춘;김남오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.726-728
    • /
    • 1998
  • Optical and electrical properties of GaSe:$Er^{3+}$ single crystals grown by the Bridgeman technique was been investigated by using optical absorption and Hall-effect measurements. The Hall coefficients were measured by using a high impedance electrometer in the temperature range from 360K to 150K. The temperature dependence of hole concentration shows the characteristic of a partially compensated p-type semiconductor. carrier density($N_H$) of GaSe doped with Erbium was measured about $3.25{\times}10^{16}\;[cm^{-3}}$ at temperature 300K, which was high than undoped specimen. Photon energy gap ($E_{gd}$) was measured about 1.7geV.

  • PDF