• Title/Summary/Keyword: High energy efficiency

Search Result 3,953, Processing Time 0.05 seconds

Effect of Lighting Saving Using High Efficiency Reflector (고효율 반사갓을 이용한 등기구 저감효과)

  • Cho, Huyn-Kyung;Kim, Jae-Chul;Jung, Seung-Bock;Im, Sang-Kug
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.148-153
    • /
    • 2006
  • This paper analyzes the effect of the energy saving and evaluates the economics using High Efficiency lighting. About 18 percent (17,000GWh) of total power demands in Korea m consumed i]l the lighting field. There isa lot of energy potential that can be saved because the power demand isolwer relatively than the others parts. The existing lighting that its length and electric energy are 32[mm] and 40[w] can alternate with high efficiency lighting which its length and electric energy are 26[mm] and 32[w]. Two Lightings is measuring the illumination and the electric energy and then are analyzed into the effect of the lighting saving by measurement.

  • PDF

The Basic Study on Economic Evaluation of Distributed Energy System Installed in Hospital (병원건물 분산에너지시스템 도입에 따른 경제성분석)

  • Hong, Won-Pyo;Kim, Hyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1136_1138
    • /
    • 2009
  • This paper gives a basic Energy performance data of micro gas turbine and Renewable Energy(BIPV and Solar Collector System) installed in Hospital Building. The efficiency of solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that burn gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. If micro gas turbine was operated only for electric energy, the efficiency was about 30%, but for combined heat and power, the efficiency was about 90%. Finally, installed in large hospital, Micro gas turbine system was operated to CHP mode, was high-efficiency system than Solar collector and BIPV system.

  • PDF

A Piezoelectric Energy Harvester with High Efficiency and Low Circuit Complexity

  • Do, Xuan-Dien;Nguyen, Huy-Hieu;Han, Seok-Kyun;Ha, Dong Sam;Lee, Sang-Gug
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.3
    • /
    • pp.319-325
    • /
    • 2015
  • This paper presents an efficient vibration energy harvester with a piezoelectric (PE) cantilever. The proposed PE energy harvester increases the efficiency through minimization of hardware complexity and hence reduction of power dissipation of the circuit. Two key features of the proposed energy harvester are (i) incorporation synchronized switches with a simple control circuit, and (ii) a feed-forward buck converter with a simple control circuit. The chip was fabricated in $0.18{\mu}m$ CMOS processing technology, and the measured results indicate that the proposed rectifier achieves the efficiency of 77%. The core area of the chip is 0.2 mm2.

The Basic Study on Economic Evaluation of Micro-turbine and Alternative Energy system Installed in Hospital (병원건물의 마이크로터빈과 신재생에너지도입에 따른 경제성평가 기초연구)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.439-444
    • /
    • 2009
  • This paper gives a basic Energy performance data of micro gas turbine and Renewable Energy(BIPV and Solar Collector System) installed in Hospital Building. The efficiency of. solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that bum gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. If micro gas turbine was operated only for electric energy, the efficiency was about 30%, but for combined heat and power, the efficiency was about 90%. Finally, installed in large hospital, Micro gas turbine system was operated to CHP mode, was high-efficiency system than Solar collector and BIPV system.

  • PDF

Analysis of Energy Performance and Green Strategies in the Foreign High-Performance Buildings

  • Park, Doo-Yong;Kim, Chul-Ho;Lee, Seung-Eon;Yu, Ki-Hyung;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: In this study, we analyzed the energy performance levels and high-performance technology trends through the case studies of foreign high-performance buildings. Method: Buildings built within 10 years were selected for the analysis of recent trends. we analyzed the buildings of U.S.A, Germany and Japan using LEED certified buildings, Passive House certified buildings and CASBEE certified buildings database for the case study of foreign high-performance buildings. A total of 20 high-performance buildings including 14 cases in U.S.A, 4 cases in Germany and 4 cases in Japan were selected. Annual energy consumption levels for 20 high-performance buildings were collected with the actual energy consumption data or data from simulation programs officially recognized by DOE. Annual energy consumption were compared with the energy performance standard of the office buildings in the CBECS database, ASHRAE Standard 90.1-2004 and Building Energy Efficiency Rating System in Korea. Result: The order of the green strategies applied in the main categories are Renewable Energy(63%), Indoor Environment Control(51%), Envelope Improvement(44%) and HVAC System & Control(28%). Specified strategies most widely used in the sub-categories are high-performance Insulation (70%), High Efficiency Heating, Cooling Source Equipment(85%), Photovoltaic&Solar Thermal(80%) and Daylighting(80%).

Analysis Performance of Super Window through Simulation and Verification Experiment (시뮬레이션과 실증실험을 통한 슈퍼윈도우의 성능분석)

  • Peak, Sang-Hun;Lee, Jin-Sung;Cho, Soo;Jang, Cheol-Yong;Sung, Uk-Joo;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1069-1074
    • /
    • 2006
  • Heat loss by window in building occupies about 1/4 of energy amount used building. Therefore, high thermal insulation of windows system can speak as very important part in save energy of building. in this research, After select most suitable frame design and Glazing system for high thermal insulation of windows, execute simulation of mixing frame and Glazing System. Also, manufacture windows with the result and execute verification experiment, with verified simulation, this research evaluated thermal insulation performance of window by Glazing System's change.

  • PDF

Evaluation of the Energy Efficiency Rating in small office building according to the Thermal Performance of Building Envelope (소규모 업무용 건물의 외피 열성능에 따른 건축물 에너지효율등급 평가 연구)

  • Kim, Sang-A;Hong, Won-Hwa;Park, Hyo-Soon
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.65-70
    • /
    • 2012
  • Each country has implemented various environmental policies to prevent natural disasters and destruction of ecosystem caused by global wanning. The republic of Korea also was performed building energy efficiency rating certification system as part of paradigm of 'Low carbon green growth' since 2010. However, the status on the building energy efficiency rating certification system has not been analyzed. In this study, We analyzed the elements affecting the energy efficiency of small office buildings focusing the status and certification cases of the building energy efficiency rating system. As a result, it is judged that thermal performance contribution of the building envelope is not high in the buildings certificated the first grade of the building energy efficiency rating system.

Study on Design Technology of Heat Pump Cycle for High Temperature Performance (고온 생산용 열펌프 사이클 설계)

  • Kim, Jong-Ryul;Kim, Seok-Young;Kim, Yong-Min;Lee, Kong-Hoon;Kim, Ook-Joong;Yi, Sung-Chul;Jung, Chi-Young;Kim, Jong-Ryeol
    • Journal of Energy Engineering
    • /
    • v.19 no.4
    • /
    • pp.228-233
    • /
    • 2010
  • About 55% of total energy is consumed in the industrial division. The industrial heat pump application will show magnificent energy saving effect as well as higher cost efficiency because of larger energy consuming volume of each facility and longer operation hour and higher stability against seasonal temperature change. Over 90% of dryer for industrial usage has hot wind heat source and hot wind dryer is the representative type covering 68.7% while its 30 ~ 50% lower heat efficiency causes lots of energy loss by exhaust air. Re-usage of exhaust air can improve energy efficiency of dryer because 68% heat energy or 78% of hot air lose in exhaust air. Therefore, high temperature heat pump dryer can be the best alternative. Comparing to the existing dryer with 30% ~ 50% energy efficiency, newly developing high temperature heat pump dryer will enhance energy efficiency up to 60% ~ 80% efficiency. In this paper, heat pump system for high temperature was designed, constructed and tested. The results have shown that system COPh is estimated as 3.3.

An Empirical Study on the Operation of Cogeneration Generators for Heat Trading in Industrial Complexes

  • Kim, Jaehyun;Kim, Taehyoung;Park, Youngsu;Ham, Kyung Sun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.29-39
    • /
    • 2019
  • In this study, we introduce a model that satisfies energy efficiency and economical efficiency by introducing and demonstrating cogeneration generators in industrial complexes using various actual data collected at the site. The proposed model is composed of three scenarios, ie, full - time operation, scenario operated according to demand, and a fusion type. In this study, the power generation profit and surplus thermal energy are measured according to the operation of the generator, and the thermal energy is traded according to the demand of the customer to calculate the profit and loss including the heat and evaluate the economic efficiency. As a result of the study, it is relatively profitable to reduce the generation of the generator under the condition that the electricity rate is low and the gas rate is high, while the basic charge is not increased. On the contrary, if the electricity rate is high and the gas rate is low, The more you start up, the more profit you can see. These results show that even a cogeneration power plant with a low economic efficiency due to a low "spark spread" has sufficient economic value if it can sell more than a certain amount of heat energy from a nearby customer and adjust the applied power through peak management.

Design of 32 bit Parallel Processor Core for High Energy Efficiency using Instruction-Levels Dynamic Voltage Scaling Technique

  • Yang, Yil-Suk;Roh, Tae-Moon;Yeo, Soon-Il;Kwon, Woo-H.;Kim, Jong-Dae
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • This paper describes design of high energy efficiency 32 bit parallel processor core using instruction-levels data gating and dynamic voltage scaling (DVS) techniques. We present instruction-levels data gating technique. We can control activation and switching activity of the function units in the proposed data technique. We present instruction-levels DVS technique without using DC-DC converter and voltage scheduler controlled by the operation system. We can control powers of the function units in the proposed DVS technique. The proposed instruction-levels DVS technique has the simple architecture than complicated DVS which is DC-DC converter and voltage scheduler controlled by the operation system and a hardware implementation is very easy. But, the energy efficiency of the proposed instruction-levels DVS technique having dual-power supply is similar to the complicated DVS which is DC-DC converter and voltage scheduler controlled by the operation system. We simulate the circuit simulation for running test program using Spectra. We selected reduced power supply to 0.667 times of the supplied power supply. The energy efficiency of the proposed 32 bit parallel processor core using instruction-levels data gating and DVS techniques can improve about 88.4% than that of the 32 bit parallel processor core without using those. The designed high energy efficiency 32 bit parallel processor core can utilize as the coprocessor processing massive data at high speed.