• 제목/요약/키워드: High dose rate remote afterloading system

검색결과 14건 처리시간 0.024초

고선량율 근접치료기의 선원교정과 치료실주변 방사선량 측정 (Calibration and Radiation Survey of High Dose Rate Remote Afterloading System)

  • 이정옥;강정구;문성록
    • Radiation Oncology Journal
    • /
    • 제13권1호
    • /
    • pp.101-104
    • /
    • 1995
  • High Dose Rate Remote Afterloading system was installed at Wonkwang University Hospital in January 1994. In this report, the calibration of a Gammamed 12-i High Dose Rate Remote Afterloading system and the radiation survey around the facility after design and construct a shieding room are discussed. The radiation survey of the facility indicates that the use of ordinary concrete shielding of existing room will provide adequate shielding. Also, the methodologies for performing source calibration are presented.

  • PDF

Personal computer를 이용한 자궁경부암의 고선량을 강내치료 계획 (Treatment Planning Software for High Dose Rate Remote Afterloading Brachytherapy of Uterine Cervical Cancer)

  • 허승재;강위생
    • Radiation Oncology Journal
    • /
    • 제4권2호
    • /
    • pp.183-186
    • /
    • 1986
  • 고선량율을 이용한 자궁강내 치료시 정확하고 신속한 계산을 위하여 저자들은 개인용 컴퓨터를 이용하여 기준점의 선량분포 및 방사선조사 시간을 간편하게 계산할 수 있는 software를 개발하였다. 치료 계획용 software를 이용하여 짧은 시간내에 선량 분포 및 조사시간을 용이하고 정확하게 계산할 수 있으며, 고선량을 자궁경부암 임상적응에 효과적으로 이용할 수 있어서 보고한다.

  • PDF

RALS시행시 선원의 거리 이동및 직장선량에 관한 계산치와 측정치의 비교연구 (Dose Distribution of Rectum in the treatment of Uterine Cervical Cancer using Remote Afterloading System)

  • 김성규;신세원;김명세
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.67-74
    • /
    • 1994
  • 선량분포특성은 거리의 제곱에 반비례하기 때문에 근접조사에서 선원의 조그마한 오차는 선량계산에서 큰 차이를 초래할 수 있어서 선원의 정확한 거리 이동과 그에 따른 critical organ에 조사되는 선량의 정확도는 자궁경부암 환자의 치료성적에 결정적인 역할을 할 수가 있다. 특히 High Dose Rate의 RALS(Remote After Loading System)에서 선원의 정확한 calibration은 자궁경부암 환자의 치료에서 선량분포에 지대한 영향을 미치며 나아가 이 선량분포는 치료후 나타나는 재발 및 합병증이나 휴유증의 발생에도 큰 영향을 미치게 된다. 본 연구에서는 실제 RALS시 선원의 거리 이동을 측정하여 치료계획용 computer에서 계산된 선원간의 거리 이동과 비교 검토하였으며 Rectum 위치에 chamber를 삽입하여 실제 Rectum에 조사되는 선량과 computer에서 계산된 값들을 비교검토하였다. Tandem Source을 1cm 간격으로 거리를 이동하면서 실험을 되풀이 한 결과 처음 monitor로 1cm을 이동할 때 측정치가 0.8cm 이동한 것으로 나타났으며, 2번째부터 5번째까지의 거리 이동에서는 monitor의 값과 측정치의 값이 정확하게 일치하였다. 또한 12명의 환자를 대상으로 실시한 Rectum dose의 측정치는 computer계산치보다 평균 8%로 낮게 나타났다.

  • PDF

진행된 담도암의 경관조사 (Transcatheter Irradiation of Advanced Extrahepatic Biliary Tract Carcinoma)

  • 김경애;김성규;신세원;김명세;송선교;권굉보
    • Radiation Oncology Journal
    • /
    • 제5권2호
    • /
    • pp.173-176
    • /
    • 1987
  • 담도암은 서서히 자라며 원격전이가 늦은데 비하여 완전절제가 어렵고 수술 후 재발율이 높아. 생존율은 매우 낮다. 많은 예에서 국소치료의 실패가 치료실패의 요인으로 밝혀짐에 따라 술후 방사선 치료의 중요성이 인정되어 왔다. 외부방사선치료 만으로는 충분한 선량을 조사할 수 없으므로 국소적인 고선량치료법으로서 술중방사선치료, 간질방사선치료 (interstitial irradiation), 경관방사선치료(transcatheter irradiation) 등이 사용되고 있으나 경관방사선치료의 보고는 드물다. 영남대학병원 치료방사선과에서는 진행된 담도암 1예에서 암 종괴의 부분절제 후 삽입된 T-자관을 통하여 고선량 방사선 치료를 실시하였기에 문헌고찰과 함께 보고하는 바이다.

  • PDF

자궁경부암 강내 방사선 조사장치에 의한 직장 및 방광의 피폭선량 평가 (Dose Distribution of Rectum and Bladder in Intracavitary Irradiation)

  • 추성실;오원용;서창옥;김귀언
    • Radiation Oncology Journal
    • /
    • 제2권2호
    • /
    • pp.261-270
    • /
    • 1984
  • The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The simulation radiation and medical records of 203 patients who were treated with intrauterine irradiation from Feb. 1983 to Oct. 1983, were critically analized. The physical parameters to include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem applicator to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids were measured for low dose rate irradiation system and high dose rate remote control afterloading system. The radiation doses and dose distributions within cervical area including interesting points and bladder, rectum, according to sources arrangement and location of applicator, were estimated with personal computer. Followings were summary of study results ; 1. In distances between lateral walls of vaginal fornices, the low dose rate system showed as $4\~7cm$ width and high dose rate system showed as $5\~6cm$. 2. In horizontal angulation of tandem to body axis, the low dose rate system revealed mid position$64.6\%$, left deviation $19.2\%$and right deviation $16.2\%$. 3. In longitudinal angulation of tandem to body axis, the mid position was $11.8\%$ and anterior angulation $88.2\%$ in low dose rate system but in high dose rate system, anterior angulation was $98.5\%$. 4. Down ward displacement of ovoids below external os was only $3\%$ in low dose rate system and $66.7\%$ in high dose rate system. 5. In radiation source arrangement, the most activities of tandem and ovoid were 35 by 30 in low dose rate system but 50 by 40 in high dose rate system. 6. In low and high dose rate system, the total doses an4 TDF were 50, 70 Gy and 141, 123, including 40 Gy external irradiation. 7. The doses and TDF in interesting points Co, B, were 93, 47 Gy and 230, 73 in high dose rate system but in low doss rate system, 123, 52 Gy and 262, 75 respectively. 8. Doses and TDF in bladder and rectum were 70, 68 Gy and 124, 120 in low dose rate system, but in high dose rate system, 58, 64 Gy 98, 110 respectively, and then grades of injuries in bladder and rectum were 25, $30\%$ and 18, $23\%$ respectively.

  • PDF

자궁경부암 고선량율 강내치료의 치료선량 정확도에 관한 연구 (Accuracy of Dose Estimation in High Dose Rate Intracavitary Radiotherapy of Carcinoma of the Uterine Cervix)

  • 허승재;하성환;채규영
    • Radiation Oncology Journal
    • /
    • 제5권2호
    • /
    • pp.137-140
    • /
    • 1987
  • 자궁경부암의 고선량율 강내치료의 매 분할 치료시마다 강내 applicator의 위치 차이로 인하여 조사 선량이 치료전 계획된 선량과 차이가 있을 수 있다. 저자는 자궁경부암 환자의 강내치료시 치료전 계획된 A점 선량 500 cGy와 치료직후에 촬영한 전후 및 측면 선 사진을 이용하여 계산된 A점 선량을 비교한 결과, 82예의 강내치료에서 치료 후 계산된 조사 선량과 계획 선량은 $500\pm18 cGy$이었으며 $84\%$에서 $500\pm25 cGy$의 범위에 포함되었다. 이러한 결과에서 계획 선량과 치료 후 계산된 조사 선량사이에 비교적 높은 일치율을 확인할 수 있었다.

  • PDF

고선량율 근접치료의 정도관리 (Quality Assurance for High Dose Rate Brachytherapy)

  • 방동완;조정희;박재일
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.30-44
    • /
    • 1998
  • Accurate delivery of doses using a high dose rate(HDR) brachytherapy, remote afterloading system(RALS) depends on knowing the strength of the radioactive source at the time of treatment, the precision and consistency of the timer, and the ability of the unit to position the source at the proper dwell location along the applicator. Periodic Quality Assurance(QA) on HDR machines is a part of the standard protocol of any user. The safety of the patient & staff, positional accuracy, temporal accuracy, and dose delivery accuracy are periodically(weekly, quarterly, monthly) estimated using HDR source(Ir-192), treatment planning devices, measurement devices, and overall treatment devices with regard to treatment delivery. The overall measurement results are estimated successfully and assessed its clinical significance. As a result, our HDR brachytherapy units has been very accurate until now. The QA program protocol permits routine clinical use and provides a high confidence level in the accurate operation of HDR units. Therefore, regular QA of HDR brachytherapy is essential for successful treatment.

  • PDF

고선량율 관내 방사선치료를 위한 종양선량분포의 최적화에 대한 연구 (Optimization of Dose Distribution for High Dose Rate Intraluminal Therapy)

  • 추성실;김귀언;노준규
    • Radiation Oncology Journal
    • /
    • 제12권2호
    • /
    • pp.243-252
    • /
    • 1994
  • 원격조종 아프터로딩에 의한 고선량율 관내삽입조사는 체내 발생된 종양에 방사선원을 근접시켜 치료하는 방사선요법으로서 신속한 선량계산과 선량의 정확성 및 다양한 모양의 최적선량분포가 요구된다. 저자들은 크기가 작고 선량율이 높은 고선량율의 방사성동위원소에 대한 정확한 조사선량과 최적선량분포를 얻기 위하여 수학적인 콤퓨터 계산프로그램과 실측으로서 비교하였다. 고선량율 선원에 의한 방사선 조사선량과 조직내 흡수선량분포는 각각 Sievert적분식과 Meisberger의 다항식을 이용하여 작성하였다. 종양크기와 모양에 가장 알맞는 선량분포의 최적화를 실현하기 위하여 저자들은 치료기준점의 선량을 일정한 값으로 고정시키고 선원의 조사시간을 조정하는 선형반복 계산방정식을 이용하였다. 모형선원이 장착된 아프터로딩관을 삽입하고 조준엑스선으로 촬영하여 종양부위를 결정한 후 콤퓨터의 도움으로 아프터로딩관의 축과 평행한 등량곡선 또는 과일모양의 선량분포 및 기관지 모양의 등선량분포가 성취되도록 선량최적화를 시행하였고 선량계에 의한 실측치와 오차가 $3\%$이하로 잘 일치하였다.

  • PDF

고선량율 강내 조사를 이용한 두경부암의 방사선 치료 (Radiation Therapy of Head and Neck Cancer with CO-60 HDR Transcatheteric Irradiation)

  • 신세원;김성규;김명세
    • Journal of Yeungnam Medical Science
    • /
    • 제7권2호
    • /
    • pp.109-114
    • /
    • 1990
  • 저자들은 두경부암의 포괄적인 치료의 일부로서 외부 방사선 조사와 고선량율 경관조사를 시행하여 12명중 9명에서 완전 관해를 얻었으며, 치료중이나 치료후 경관조사와 직접 관련된 급성 부작용이나 합병중의 발생이 없었다. 그러나 대상환자가 적고 추적기간이 짧은관계로 생존율의 향상은 추측하기 어려우나 완전 관해를 얻은 환자는 장기간 무병 상태로 추적되고 있어서 외부방사선 조사와 경관 조사는 두경부암 치료에 큰 역할을 하리라 기대된다.

  • PDF

강내 조사를 이용한 비인강압 치험2예 (Two Cases of Nasopharyngeal Carcinoma Treated with Co-60 HDR ICR)

  • 신세원;강철훈;김성규;김명세
    • Journal of Yeungnam Medical Science
    • /
    • 제7권1호
    • /
    • pp.197-201
    • /
    • 1990
  • 저자들은 비인강암의 포괄적인 방사선 치료의 일부로서 외부 방사선 치료에 뒤이은 고선량율 강내조사를 시행하여 부작용이나 합병증 없이 종양의 완전관해를 얻었기에 문헌고찰과 함께 보고하는 바이다.

  • PDF