• 제목/요약/키워드: High contrast ratio

검색결과 537건 처리시간 0.034초

광기록 매질로 이용되는 Te계 ART구조의 광학적 해석 (The optical analysis of Te-based ART structure for the optical recording media)

  • 이성준;박태성;정홍배
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권3호
    • /
    • pp.220-224
    • /
    • 1994
  • In this study, we discussed the optical property to find the optimal condition of Te-based antireflection trilayer(ART) structure for a high density optical recording. It was found that the optical property was improved by suggesting the environmental parameters satisfied the optimum condition. As the results, the optimized(.lambda.=8.000${\AA}$.) thickness of the recording layer is 27${\AA}$, and the 1st and 2nd minimum ART conditions of dielectric layers are 1080${\AA}$, 3820${\AA}$, respectively. And the high SNR, the contrast ratio and the sensitivity are achieved by using the ART conditions.

  • PDF

대전입자를 이용한 고성능 Guest-Host 액정 디스플레이 모드 (High performance guest-host liquid crystal display mode using the charged particles)

  • 문병준;윤성호;이기동
    • 한국정보통신학회논문지
    • /
    • 제16권7호
    • /
    • pp.1512-1517
    • /
    • 2012
  • 본 논문에서는 Guest-Host 디스플레이의 문제점인 낮은 명암대비비를 해결하기 위해서 음전하로 대전 된 흑색입자를 이용한 고성능 하이브리드 Guest-Host 디스플레이를 제안하였다. 우리는 패턴 된 전극구조의 설계로 전압에 따른 입자의 스위칭을 고려하였으며, 염료 및 입자의 혼합비를 최적화하여 전기광학특성을 향상 시켰다. 따라서 기존 Heilmeier Guest-Host 디스플레이에 비교하여 dark 특성을 80%이상 향상시켰으며, 명암대비비를 비교분석함으로써 제안 된 모드의 성능 우수성을 검증하였다.

The Variation of Tagging Contrast-to-Noise Ratio (CNR) of SPAMM Image by Modulation of Tagline Spacing

  • Kang, Won-Suk;Park, Byoung-Wook;Choe, Kyu-Ok;Lee, Sang-Ho;Soonil Hong;Haijo Jung;Kim, Hee-Joung
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.360-362
    • /
    • 2002
  • Myocardial tagging technique such as spatial modulation of magnetization (SPAMM) allows the study of myocardial motion with high accuracy. Tagging contrast of such a tagging images can affect to the accuracy of the estimation of tag intersection in order to analyze the myocardial motion. Tagging contrast can be affected by tagline spacing. The aim of this study was to investigate the relationship between tagline spacing of SPAMM image and tagging contrast-to-noise ratio (CNR) experimentally. One healthy volunteer was undergone electrocardiographically triggered MR imaging with SPAMM-based tagging pulse sequence at a 1.5T MR scanner (Gyroscan Intera, Philips Medical System, Netherland). Horizontally modulated stripe patterns were imposed with a range from 3.6mm to 9.6mm of tagline spacing. Images of the left ventricle (LV) wall were acquired at the mid-ventricle level during cardiac cycle with FEEPI (TR/TE/FA=5.8/2.2/10). Tagging CNR for each image was calculated with a software which developed in our group. During contraction, tagging CNR was more rapidly decreased in case of short tagline spacing than in case of long tagline spacing. In the same heart phase, CNR was increased corresponding with tag line spacing. Especially, at the fully contracted heart phase, CNR was more rapidly increased than the other heart phases as a function of tagline spacing.

  • PDF

조영제 주입 전 1.5T 와 3.0T를 이용한 복부장기 자기공명영상에서 영상의 질 비교 (Comparison of Image Quality in Magnetic Resonance Imaging of the Abdominal Organ at 1.5T and 3.0T before the Gadolinium Injection)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.619-625
    • /
    • 2017
  • 본 연구는 조영제 주입 전 복부 검사 시 필수적으로 적용되고 있는 HASTE, HASTE(f/s), FFE(in, out)를 중심으로 두 기기에 대한 복부장기의 신호 대 잡음비(SNR; Signal to Noise Ratio)와 대조도 대 잡음비(CNR; Contrast to Noise Ratio)를 정량적으로 평가함으로서 최적의 장비선택을 알아보고자 하였다. 데이터분석은 1.5T 와 3.0T 자기공명영상기기(Philips medical system, Netherland)를 이용하여 검사한 복부영상을 무작위로 선정하여 분석을 하였다. 정량적 분석결과 간(Liver), 신장(Kidney), 비장(Spleen)에서는 1.5와 비교했을 때 3.0T가 SNR, CNR 값이 높게 나타났고(p<0.05), 위(Stomach), 복부지방(Abdominal Fat), 췌장(Pancreas)에서는 1.5T 가 높은 결과를 얻었다(p<0.05). 결론적으로 두기기별 장기에 대한 정량적 평가를 했을 때 인체의 바같 부분 조직은 전반적으로 3.0T 가 높게 나타났고 가스를 포함하여 자화율의 차이를 많이 발생시키는 안쪽부분의 장기는 1.5T 가 높은 결과를 얻었다. 이러한 결과는 환자상태에 따라 조영제를 사용하지 못하고 MRI 검사를 하는 경우 정확한 진단학적 정보를 제공하는데 가이드라인이 될 것이다.

산소주입에 의한 FLAIR 영상에서 생리식염수의 신호 변화 (Signal Change of Normal Saline by Oxygen Injection in FLAIR Image)

  • 신운재
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.55-63
    • /
    • 2019
  • 고농도의 산소를 흡입하는 경우에 자기공명영상의 FLAIR(fluid attenuated inversion-recovery, FLAIR) 영상에서 뇌척수액에서 신호가 억제되지 않고 고신호로 나타나는 경우가 있다는 보고가 있었다. 본 연구는 아가 젤로 고정한 팬텀을 제작하여 산소를 주입한 생리식염수와 조영제를 희석한 생리식염수의 신호를 FLAIR 기법의 반전시간(TI : inversion time)을 변화하여 영상을 획득하고, 분석하여 기초자료를 마련 하고자 하였다. 부산 P병원의 Philips Achieva MR 3.0T를 이용한 결과에서 자기공명영상의 FLAIR 기법에서 산소가 주입된 생리식염수의 신호 대 잡음비(signal to noise ratio)는 산소가 주입되지 않은 생리식염수 보다 증가되었다. 하지만 희석된 조영제보다는 높지 않았다. 반전시간 1,800ms에서는 산소에 의한 신호 증강이 없는 영상을 획득할 수 있었다. 산소가 주입된 생리식염수와 조영제의 대조도 대 잡음비(contrast to noise ratio)에서도 임상에서 주로 사용하는 반전시간 2,800ms보다 1,800ms에서 높게 증가되었다. 본 실험의 결과가 자기공명영상의 FLAIR 기법에서 산소 주입에 따른 뇌척수액의 신호 변화 연구에 기초자료가 될 수 있을 것으로 사료된다.

대 면적 LCD에서 Patterned Spacer Color Filter 사용 시 발생하는 중력무라 분석 (The Analysis of Gravity Mura Induced in Patterned Spacer Color Filter on Large Size LCD)

  • 최석;정연학;김미숙;김귀현;김향율;김서윤;임영진
    • 한국전기전자재료학회논문지
    • /
    • 제17권8호
    • /
    • pp.871-874
    • /
    • 2004
  • In recent, it is said that the trend of LCD is direction to pursue high qualities like as high transmittance, high contrast ratio, wide viewing angle, fast response time, and so on. Especially, it is known that these qualities are essential to large size LCD like as LCD TV and we can realize them through to uniform cell gap and deep black state. Until now, the ball spacer has been used to control of uniform cell gap. However, the existence of ball spacer inside the cell causes the deformation of the liquid crystal molecules and damage to alignment layer. Such a deformation of the liquid crystal causes light-leakage in the dark state, which lowers contrast ratio of the display. Nowadays, this problem has been solved by using Patterned Spacer on Color Filter. but Side Effect just as gravity mura has been induced. In this paper, we studied the mechanism on gravity mura in case of using patterned spacer on color filter.

Reflective Twist Nematic Liquid Crystal Display For High Reflectance.

  • Son, Ock-Soo;Park, Young-Il;Beak, Do-Hyoen;Son, Gon;Suh, Dong-Hea
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.292-294
    • /
    • 2008
  • We have developed new reflective LCD for Mixed twist nematic LC mode with high quality image. We have found out an optimal twist angle of LC and optical film's axis by simulation. Also we measured electro-optic characteristics for new design panel. As a result, high reflectance and wide viewing angle characteristics were achieved.

  • PDF

Transflective Dual Operating Mode Liquid Crystal Display with Wideband Configuration

  • Lee, Joong-Ha;Kim, Tae-Hyung;Yoon, Tae-Hoon;Kim, Jae-Chang;Jhun, Chul-Gyu;Kwon, Soon-Bum
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.260-265
    • /
    • 2010
  • This paper proposes a transflective configuration of the dual operating mode liquid crystal display, which has transmissive dynamic and reflective memory parts in its pixel. By employing a wideband structure and optimizing the cell-gap of the liquid crystal layer, the reflective memory part shows a very low reflectance in the dark state, good dispersion properties for the entire visible range, as well as high reflectance in the bright state. The transmissive dynamic part is designed to have the same cell-gap and rubbing direction as those of the reflective part. The driving voltage of the dynamic part and transmittance of the bright state can also be controlled by using compensation film with a positive a-plate, which can compensate the reflective part. Experimental results in the memory part operation demonstrate that the contrast ratio is over 50:1 and the reflectance in the dark state is reduced to 56% on average of that of the conventional dual mode configuration for the entire visible range. The contrast ratio of the dynamic part is 300:1.

The Utility Evaluation of Reconstructed 3-D Images by Maximum Intensity Projection in Magnetic Resonance Mammography and Cholangiopancreatography

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-Soo;Kim, Ham-Gyum;Baek, Jong-Geun;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • 제19권4호
    • /
    • pp.365-371
    • /
    • 2014
  • The aim of this study was to evaluate the utility of 3-D images by comparing and analyzing reconstructed 3-D images from fast spin echo images of MRI cholangiopancreatography (MRCP) images using maximum intensity projection (MIP) with the subtraction images derived from dynamic tests of magnetic resonance mammography. The study targeted 20 patients histologically diagnosed with pancreaticobiliary duct disease and 20 patients showing pancreaticobiliary duct diseases, where dynamic breast MR (magnetic resonance) images, fast spin echo imaged of pancreaticobiliary duct, and 3-D reconstitution images using a 1.5T MR scanner and 3.0T MR scanner were taken. As a result of the study, the signal-to-noise ratio in the subtracted breast image before and after administering the contrast agent and in the reconstructed 3-D breast image showed a high ratio in the reconstructed image of lesional tissue, relevant tissue, and fat tissue. However, no statistically meaningful differences were found in the contrast-to-noise ratio of the two images. In the case of the MRCP image, no differences were found in the ratios of the fast spin echo image and reconstructed 3-D image.

Resolution Recovery 기반의 Astonish 영상 재구성 기법의 평가 (The Evaluation of Resolution Recovery Based Reconstruction Method, Astonish)

  • 승종민;이형진;김진의;김현주;김중현;이재성;이동수
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.58-64
    • /
    • 2011
  • SPECT 영상에서의 resolution recovery를 기반으로 하는 3D 재구성 기법은 detector면으로부터 거리에 의한 공간적 blur를 보상하여 높은 spatial resolution과 contrast를 가지는 특징이 있다. 본 논문에서는 이러한 재구성 기법 중의 하나인 Philips사의 Astonish 프로그램을 phantom 실험을 통하여 기존의 재구성 기법과 비교, 평가하고 임상적 유용성을 높이고자 하였다. Skylight SPECT system (Philips)에서 NEMA IEC PET body phantom과 Flanges Jaszczak phantom (Data Spectrum corp.)을 이용하여 시간과 거리에 따른 4가지의 다른 입력 조건에서 실험을 실시하였다. 가까운 거리와 먼 거리 (짧은 거리보다 10 cm 더해진 거리)에서 각각 full time (40 kcts/frame)과 half time (full time의 절반)을 적용하여 영상을 얻고, iteration 수에 변화를 주어 MLEM, 3D-OSEM, Astonish로 영상을 재구성하였다. NEMA IEC PET body phantom의 각 sphere에서 background variability에 따른 contrast ratio의 변화양상을 확인하고 각 재구성 기법에서의 최적의 iteration 수를 찾아보았다. 이로부터 얻은 최적의 iteration 수를 Jaszczak phantom 영상의 재구성에 적용하여 비교해보고 실제 환자의 myocardial SPECT data에 대하여 육안적 평가를 실시하였다. 전반적인 contrast ratio는 Astonish가 MLEM과 3D-OSEM보다 높았다. 직경 37 mm의 가장 큰 hot sphere에서 짧은 거리에서는 Astonish가 MLEM과 3D-OSEM보다 각각 27.1%와 17.4%의 더 높은 contrast ratio를 보였고, 먼 거리에서는 40.5%와 32.6%로 더 높았다. 그러나 시간에 따른 변화의 차이는 크게 나타나지 않았다. 또한, 육안적 평가에서 Astonish가 다른 두 재구성 기법에 비하여 더 좋은 영상을 보였다. 이 실험에서는 정량적 분석 및 육안적 평가를 통하여 Astonish가 기존의 영상 재구성 기법인 MLEM과 3D-OSEM에 비하여 시간을 단축시켜 업무의 효율성을 높일 뿐만 아니라 질적으로도 우수한 영상을 구현하여 임상적으로 신뢰성이 높은 검사 결과를 제공할 수 있음을 확인하였다.

  • PDF