• Title/Summary/Keyword: High back pressure

Search Result 268, Processing Time 0.028 seconds

Air Similarity Test for the Evaluation of Aerodynamic Performance of Steam Turbine (스팀터빈의 공력성능 평가를 위한 공기 상사실험)

  • Lim, Byeung-Jun;Lee, Eun-Seok;Yang, Soo-Seok;Lee, Ik-Hyoung;Kim, Young-Sang;Kwon, Gee-Bum
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.5 s.26
    • /
    • pp.29-35
    • /
    • 2004
  • The turbine efficiency is an important factor in power plant, and accurate evaluation of steam turbine performance is the key issue in turbo machinery industry. The difficulty of evaluating the steam turbine performance due to its high steam temperature and pressure environment makes the most steam turbine tests to be replaced by air similarity test. This paper presents how to decide the similarity conditions of the steam turbine test and describes its limitations and assumptions. The test facility was developed and arranged to conduct an air similarity turbine performance test with various inlet pressure, temperature and mass flow rate. The eddy-current type dynamometer measures the turbine-generated shaft power and controls the rotating speed. Pressure ratio of turbine can be controled by back pressure control valve. To verify its test results, uncertainty analysis was performed and relative uncertainty of turbine efficiency was obtained.

Hydroforming Process Design of High-Strength Steel Tube (고장력강 관재 액압성형 공정 설계)

  • Kim, K.J.;Kim, H.Y.;Ko, H.G.;Shin, M.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.202-205
    • /
    • 2009
  • Tubular torsion beam of high strength steel is going about in an automotive rear axle due to the advantages of light weight and efficient rear packaging capability. High strength tubular beam can be manufactured by the hydroforming in order to ensure dimensional accuracy, while a conventional stamping has been used for steel tubular beam. Internal pressure, feeding and their combination are the key factors of controlling the process. Based on the numerical simulation and try-outs, the optimized hydroforming process conditions for the high strength tubular beam were suggested.

  • PDF

The Study on Musculoskeletal Effects of Heel Types (구두 굽의 형태가 인체의 근골격계에 미치는 영향에 관한 연구)

  • Lee, Chang-Min;Jeong, Eun-Hui
    • Journal of the Ergonomics Society of Korea
    • /
    • v.23 no.1
    • /
    • pp.39-48
    • /
    • 2004
  • In terms of women engaged in clerical job. working time of the workers who mainly keep standing with their high-heeled shoes on has been increasing. According]y. they are exposed to many kinds of foot deformation caused by loads of lower back and lower extremities due to high-heeled shoes. The type of heels they usually wear are diverse though the hight is same. In this study. we investigated most women's favorite styles of shoes concerned with heights. types and contact areas of the heels. Hence. we designed three kinds of shoes for an experiment: their contact areas with ground are 1 cm2. 2-4 cm2 and over 9 cm2 according to the heel heights. respectively. To investigate the biomechanical effects. analysis of motion and EMG were applied to the experiments. In addition. foot pressure distribution was measured for more detailed analysis. Six healthy young women were participated in this experiments. The result showed the heel becoming higher and narrower increased not only fluctuation of CBM(Center of Body Mass). but also the load of low back muscle and lower extremities. Accordingly. there was significant difference among types of the heel in terms of the role supporting load of the body. though the height is same. Especially. the difference among the pressures on a foot was most significant. In conclusion. we verified biomechanical effects are related with the contact area of a heel with ground as well as the hight.

A Study for Pressure Difference and Critical Velocity by Pressurization of Elevator Shaft at High Rise Apartment (고층 공동주택의 승강로가압을 이용한 차압 및 방연풍속에 관한 연구)

  • Park, Kyung-Hwan;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.89-93
    • /
    • 2011
  • It is not recommended that elevator use for egress at (super) high rise buildings because elevator shaft main roles to spread of fire smoke. But in North America used to protect this area by elevator shaft pressurization. These tests are performed at high rise apartment to verify that elevator shaft pressurization can protect to spread of fire smoke or not. and verify to used for egress at fire. Pressurization at elevator shaft make pressure difference of 50 Pa all floor at 150 CMM because this method have low friction loss from air flow. Also when dwelling door and elevator door are opened that critical velocity is performed to protect of back-layering from fire room for escape routs by 180 CMM. Therefore through out these pressurization tests by elevator shaft are estimated to have less overpressure because supply air difference are low between to satisfy critical velocity at one door opened and maintain to pressure difference all doors closed. Finally we verified that disable or residual people can use elevator for egress at fire by elevator shaft pressurization.

Analysis of Plantar Foot Pressure During Golf Swing Motion of Pro & Amateur Golfer (프로와 아마추어 골퍼의 골프스윙 동작시 족저압력 비교 분석)

  • Lee, Joong-Sook;Lee, Dong-Ki
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.41-55
    • /
    • 2005
  • In this study, weight carrying pattern analysis and comparison method of four foot region were suggested. We used three types of club(driver, iron7, pitching wedge). This analysis method can compare between top class golfer and beginner. And the comparison data can be used to correct the swing pose of trainee. If motion analysis system, which can measure the swing speed and instantaneous acceleration at the point of hitting a ball, is combined with this plantar foot force analysis method, new design development of golf shoes to increase comfort and ball flight distance will be available. 1. Regional change of force acting, in address, is evenly distributed on both feet. In back swing top, 76% on right foot, 75% on left foot as impact, and 86% on left foot as finish. As regional force acting, in address, pros get high marks on rare and inside of right foot and rare and outside for amateurs. In back swing top, it is higher as fore and inside of left foot, pros as rare part of right foot and amateurs as forefoot. In impact, it is higher for pros and amateurs in outside and rare part of left foot and fore and inside of right foot. In finish, for both pros and amateurs, it is higher for outside and rare parts of left foot. 2. For each club, forces are evenly distributed on both feet in address. In back swing top, the shorter a club is, the higher impact on right foot and the higher finish distribution on left foot. For all the clubs used, in each region, pros get higher on rare and inside of right foot and as amateurs on rare and outside of left foot in address. In back swing top, for all clubs, pros get higher on rare and outside of right foot as fore and outside for amateurs. In impact acting, for all clubs, rare and outside of left foot get higher. In finish, force concentrates on rarefoot. 3. On both feet force, right foot forces of amateurs is higher than those of pros in back swing top. In impact and finish, pros get higher on left foot.

Clinical Effectiveness of Ultrasound-guided Costotransverse Joint Injection in Thoracic Back Pain Patients

  • Yoon, Kyung Bong;Kim, Shin Hyung;Park, Sang Jun;Moon, Ji Ae;Yoon, Duck Mi
    • The Korean Journal of Pain
    • /
    • v.29 no.3
    • /
    • pp.197-201
    • /
    • 2016
  • Because of its anatomical location and function, the costotransverse (CTRV) joint can be a source of thoracic back pain. In this retrospective observational study, we evaluated the clinical effectiveness of the CTRV joint injection in thoracic back pain patients with suspected CTRV joint problems. We enrolled 20 thoracic back pain patients with localized tenderness that was provoked by the application of pressure on the affected CTRV joints. We injected it with 0.5 ml of a ropivacaine and triamcinolone mixture at each level. The mean pre-injection pain score decreased by 37.9% ($7.2{\pm}1.5$ to $4.5{\pm}1.7$, P < 0.001) two weeks after CTRV joint injection. In addition, 70% of patients reported an excellent or good level of satisfaction. We demonstrated that an ultrasound-guided injection of the CTRV joint reduced patients' pain scores and led to a high level of satisfaction at short-term follow-ups in patients with suspected CTRV joint problems.

A Clinical Study: Pain Intensity Before and After Balneotherapy in Participants with Low Back Pain (5주간의 온천요법 전후 요통의 통증변화에 관한 임상연구)

  • Shin, Jae-Hwa;Li, Yu-Chen;Choi, Bo-Mi;Ahn, Taek-Won;Lee, Jung-Min
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.3
    • /
    • pp.133-140
    • /
    • 2013
  • Objectives The aim of this clinical study was to find out the changes of self-reported pain intensity before and after balneothrapy in participants with low back pain. Methods In this study 20 participants with low back pain went through 5 weeks of balneothrapy course, once in a week. Each week visual analogue scale (VAS) and pain threshold were measured before and after balneothrapy, which consisted of 30 minutes of high pressure underwater shower ($32{\sim}36^{\circ}C$) and another 30 minutes of whole body bathing ($32{\sim}40^{\circ}C$). Results 1. The average of VAS significantly decreased from $64.00{\pm}16.35$ to $34.00{\pm}15.69$ after 5 weeks of balneothreapy (p<0.001). 2. The average of pain threshold significantly increased from $8.31{\pm}2.52$ lbf to $9.53{\pm}3.11$ lbf after 5 weeks of balneothreapy (p<0.05). Conclusions The results showed that 5 weeks of balneotherapy had significant effect on alleviating pain in low back pain participants, which means balneothreapy may be used as a complementary treatment on musculoskeletal diseases and other chronic diseases. Further studies are anticipated in the future to find out other various effects of balneothrapy.

Effects of Premixed Fuel and EGR on the Combustion and Emissions Characteristics of HCCI Diesel Engine (HCCI디젤엔진의 연소 및 배기 특성에 미치는 예혼합 연료와 EGR의 영향)

  • Yoon, Young-Hoon;Kim, Dae-Sik;Lee, Chang-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.9 s.240
    • /
    • pp.1006-1012
    • /
    • 2005
  • The effects of premixed fuels(diesel or n-heptane) and exhaust gas recirculation on combustion and exhaust emission characteristics in a DI diesel engine were experimentally investigated. To improve homogeneity of fuel-air mixture in the conventional diesel engine, the premixed fuel is injected by high pressure(5.5 MPa) into the premixing chamber prior to engine cylinder, And several additional systems such as an EGR system, air heating system and back pressure control system were equipped in the DI diesel engine. The results showed that premixed fuel-air mixture undergoes typical HCCI combustion prior to the combustion of DI diesel fuel. The ignition timing of HCCI combustion is delayed by application of EGR, and it also shows that HCCI combustion can be controlled by an EGR.

Characteristics of Negative Peak Wind Pressure acting on Tall Buildings with Step on Wall Surface

  • Yoshida, Akihito;Masuyama, Yuka;Katsumura, Akira
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.4
    • /
    • pp.283-290
    • /
    • 2019
  • Corner cut, corner chamfered or a building shape change are adopted in the design of tall buildings to achieve aerodynamic superiority as well as response reduction. Kikuchi et.al pointed out that large negative peak external pressures can appear near the inside corner of set-back low rise buildings. It is therefore necessary to pay attention to facade design around steps in building surfaces. Peak wind pressures for corner cut or corner chamfered configurations are given in the AIJ code. However, they cannot be applied where there are many variations of vertical and horizontal steps. There has been no previous systematic research on peak wind pressures around steps in building surfaces. In this study, detailed phenomenon of peak wind pressures around steps in buildings are investigated focusing on vertical and horizontal distances from the building's corner.

An Experimental Study on Effects of Soot Loading and Mass Flow Rate on Pressure Drop and Heat Transfer in Catalyzed Diesel Particulate Filter (촉매 코팅 DPF의 soot loading과 유량 변화에 따른 압력강하 및 열전달에 관한 실험적 연구)

  • Cho, Yong-Seok;Noh, Young-Chang;Park, Young-Joon;Kim, Duk-Sang
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.72-78
    • /
    • 2007
  • A diesel particulate filter causes progressive increase in back pressure of an exhaust system due to the loading of soot particles. To maintain the pressure drop caused by DPF under proper level, a regeneration process is mandatory when excessive loading of soot is detected in the filter. It is a major reason why the relation between the amount of soot and the pressure drop in a DPF becomes crucial. On the other hand, pressure drop varies with not only the soot loading but also conditions of exhaust gas such as mass flow rate. Therefore, the relation among them becomes complicated. Furthermore, the characteristics of heat transfer in a DPF is another crucial parameter in order for the filter to avoid thermal crack during regeneration period. This study presents characteristics of pressure drop under various conditions of soot loading and mass flow rate in catalyzed diesel particulate filter. This study also shows characteristics of heat transfer in DPF when high temperature gas flows into the filter. Experiments reveal that the soot loading and mass flow rate affect characteristics pressure drop independently. Experiments also indicate that the amount of coating material has little influence on pressure drop with changes in soot loading and mass flow rate. However, increased catalyst coating may lead to the improved heat transfer which is efficiency to reduce thermal stress of the filter.