• Title/Summary/Keyword: High Tension Steel

Search Result 344, Processing Time 0.022 seconds

Design of Long Span Overhead Transmission Line using Special High-tension Wire (특수 고장력전선을 사용한 장경간 가공송전선로 설계)

  • Na, Sang-Yong;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.183-187
    • /
    • 2016
  • Recently, power demand has been increasing every year according to variation of electrical equipments and temperature rise in summer season. So, much more overhead line is being demanded to copy with increasing power demand and operate reliable power system. This paper analysis the characteristics of long span overhead transmission line using special high-tension wire in such as a safety factor, coefficient of elasticity, and the coefficient of linear expansion. Based on the analysis, we proposed the effectiveness of special high-tension wire having much more advantages with respect to height of steel tower and dip compared with conventional ACSR in long span overhead transmission line.

New constitutive models for non linear analysis of high strength fibrous reinforced concrete slabs

  • Yaseen, Ahmed Asaad;Abdul-Razzak, Ayad A.
    • Structural Engineering and Mechanics
    • /
    • v.82 no.1
    • /
    • pp.121-131
    • /
    • 2022
  • The main goal of this study is to prepare a program for analyzing High Strength Steel Fibrous Reinforced Concrete (HSSFRC) slabs and predict the response and strength of the slab instead of preparing a prototype and testing it in the laboratory. For this purpose, new equations are proposed to represent the material properties of High Strength Steel Fibrous Reinforced Concrete. The proposed equations obtained from performing regression analysis on many experimental results using statistical programs. The finite element method is adopted for non-linear analysis of the slabs. The eight-node "Serendipity element" (3 DoF) is chosen to represent the concrete. The layered approach is adopted for concrete elements and the steel reinforcement is represented by a smeared layer. The compression properties of the concrete are modeled by a work hardening plasticity approach and the yield condition is determined depending on the first two stress invariants. A tensile strength criterion is adopted in order to estimate the cracks propagation. many experimental results for testing slabs are compared with the numerical results of the present study and a good agreement is achieved regarding load-deflection curves and crack pattern. The response of the load deflection curve is slightly stiff at the beginning because the creep effect is not considered in this study and for assuming perfect bond between the steel reinforcement and the concrete, however, a great agreement is achieved between the ultimate load from the present study and experimental results. For the models of the tension stiffening and cracked shear modulus, the value of Bg and Bt (Where Bg and Bt are the curvature factor for the cracked shear modulus and tension stiffening models respectively) equal to 0.005 give good results compared with experimental result.

A Fuzzy Tension Control Method for the Coupled Looper System at the Hot Rolling Process (열연 루퍼시스템의 퍼지 장력제어)

  • Hur, Yone-Gi
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.1006-1012
    • /
    • 2010
  • The hot rolling process ranks the highest position for production in steel making process. The hot strip manufacturing processes consist of the reheating furnace, roughing and finishing mill and coiler. The reheating furnace heats the slab. The roughing and finishing mill produce the hot strip from slab. The hot strip quality mainly depends on finishing mill, which consists of 4-high 7 stands. The looper is installed between stands and is used for controlling the strip tension by the looper angle for better material flow. It is difficult to control the strip tension with the coupled looper system from interaction between the looper angle and strip tension. Too much deviation of strip tension severely affects the poor width quality of the hot strip. It is important to control simultaneously both the looper angle and strip tension with each of their target values. This paper proposes the fuzzy tension control, which is developed to minimize the width deviation of the hot strip by maintaining the proper strip tension between stands and to achieve the stable operation of the coupled looper system. The fuzzy tension control performance is compared with the conventional PID control by experimental results.

Slip Behavior of Friction Type High-Tension Bolted Joints with Oversize Hole (과대공을 갖는 고장력 볼트 마찰이음부의 미끄러짐 거동)

  • Cho, Sun Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.301-307
    • /
    • 1997
  • In field fabrication of steel members, the oversize hole is frequently required due to reaming and mismatching. But, there are no provisions and investigations about oversize hole in the Korean specifications. So, in this study, the tension test of friction type high-tention bolted joints is performed with parameters of bolt hole size, surface treatment and tightening force, and investigate the effect of slip behavior with those parameters. From the results, the enough tightening force is needed to obtain some degree slip load in shot blast treatment case, although tightening force is reduced somewhat, it is no problem to guarantee slip load in zincrich primer case. The slip behavior of joints with oversize hole(26mm) is similar to the slip behavior of joints with hole of nominal size.

  • PDF

Mechanical Characteristics of High Tension Bolted Joint Connections using Shear Ring (전단링을 사용한 고장력볼트 이음부의 역학적 특성에 관한 연구)

  • Lee, Seung Yong;Park, Young Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2A
    • /
    • pp.327-338
    • /
    • 2006
  • Friction type high tension bolted joints is one of the most common steel structure connections and requires significant concerns on axial force of the bolts. However, its high shear capacity is not appropriately considered in design and hence the number of bolts is over-designed than actually required. It is primarily due to a slip-load-based design method. This study, therefore, suggests a new technology of connection using a shear ring, which may reduce the shortcomings from the friction-typed high tension bolted joints and maximize the advantages from the bearing-typed joints. Experimental and numerical studies were performed to compare the capacity of the suggested method with traditional high tension bolted joints. From the results, it is known that the suggested connections has higher bearing capacity than friction-typed high tension bolted joints due to the higher shear resistance from the ring. For further study, it may be necessary to investigate on design parameters including the depth of shear ring, for increased connection capacity.

Development of Core Material with High Magnetic Induction and Low Iron Loss for Middle-Frequency Applications (고자속밀도와 저손실 특성을 갖는 중주파수대 철심재료 개발 및 응용)

  • Cho, Seong-Soo;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.190-195
    • /
    • 2009
  • Thin-gauged 3% silicon steel sheets having a highly grain-oriented texture have been developed as a core material for applications of middle-frequency (400 Hz ${\sim}$ 10 kHz) devices. The newly developed sheets with a tension coating showed an excellent reduction in iron loss at 400 Hz (iron loss at 1.0 T and 400 Hz = 4.677 W/kg, iron loss at 1.5 T and 400 Hz = 9.742 W/kg) due to high magnetic induction, $B_{10}$(measured induction at 1000 A/m), of over 1.9 T. In cases of frequencies below 400 Hz, magnetic induction, $B_{10}$, of the sample plays a major role to reduce its iron loss as excitation induction increases, whereas, in case of frequency of 1 kHz, thickness dependence becomes dominant due to a lower iron loss at relatively thinner sample. The sheets with a high magnetic induction, therefore, are favorable for high excitation induction (over 1.0 T) and low excitation frequency (below 400 Hz) applications, whereas the sheets that can reduce eddy current loss by reducing thickness or domain wall width are advantageous for low excitation induction (below 1.0 T) and high excitation frequency (around 1 kHz) applications.

Post-peak behavior and flexural ductility of doubly reinforced normal- and high-strength concrete beams

  • Pam, H.J.;Kwan, A.K.H.;Ho, J.C.M.
    • Structural Engineering and Mechanics
    • /
    • v.12 no.5
    • /
    • pp.459-474
    • /
    • 2001
  • The complete moment-curvature curves of doubly reinforced concrete beams made of normal- or high-strength concrete have been evaluated using a newly developed analytical method that takes into account the stress-path dependence of the constitutive properties of the materials. From the moment-curvature curves and the strain distribution results obtained, the post-peak behavior and flexural ductility of doubly reinforced normal- and high-strength concrete beam sections are studied. It is found that the major factors affecting the flexural ductility of reinforced concrete beam sections are the tension steel ratio, compression steel ratio and concrete grade. Generally, the flexural ductility decreases as the amount of tension reinforcement increases, but increases as the amount of compression reinforcement increases. However, the effect of the concrete grade on flexural ductility is fairly complicated, as will be explained in the paper. Quantitative analysis of such effects has been carried out and a formula for direct evaluation of the flexural ductility of doubly reinforced concrete sections developed. The formula should be useful for the ductility design of doubly reinforced normal- and high-strength concrete beams.

Development of High Strength and Low Loss Overhead Conductor(I) - Mechanical Properties (고강도 저손실 가공송전선의 개발(I) - 기계적 특성)

  • Kim, Byung-Geol;Kim, Shang-Shu;Park, Joo-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.12
    • /
    • pp.1152-1158
    • /
    • 2005
  • New conductor is developed by using high strength nonmagnetic steel(NM) wire as the core of overhead conductor. This conductor is called ACNR overhead conductor(Aluminum Conductor Nonmagnetic Steel Reinforced). Formed by the combination of aluminum alloy wire and high strength nonmagnetic steel wire, it has about the same weight and diameter as conventional ACSR overhead conductor. To enhance properties beneficial in an electrical and mechanical conductor during the process of high strength nonmagnetic steel wire, we made a large number of improvements and modifications in the working process, aluminum cladded method, and other process. ACNR overhead conductor, we successfully developed, has mechanical and electrical properties as good as or even better than conventional galvanized wire. Microstructure of raw material M wire was austenite and then deformed martensite after drawing process. Strength at room temperature is about $180kgf/mm^2\~200kgf/mm^2$. NM wire developed as core of overhead conductor shows heat resistant characteristics higher than that of HC wire used as core of commercial ACSR overhead conductor, Strength loss was not occur at heat resistant test below $600^{\circ}C$. Fatigue strength of vibration fatigue is about $32kgf/mm^2\~35kgf/mm^2$ and that of tension-tension fatigue is $90kgf/mm^2\~120kgf/mm^2$ which is $50\~65\%$ of tensile strength.

Shear Strenhth and Ductility of Steel-Fiber Reinforced High Strength Concrete Beams with Shear Confinement (전단보강이 있는 강섬유 보강 고강도 철근콘크리트 보의 전단 및 연상에 관한 연구)

  • 오정근;이광수;권영호;신성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.2 no.4
    • /
    • pp.53-60
    • /
    • 1990
  • Investigations on the behavior of steel fiber reinforced high strength concrete beams with shear confinement are accomplished to determine their ultimate shear strength including diagonal tension strength. The parameters varied were the shear confinement ratio(Ps), and fiber volume fraction(Vs). Ultimate shear strength increased significantly in steel fiber reinforced concrete beam without shear confinement. In steel- fiber reinforced high strength concrete beams with shear confinement, there is no increase of ultimate shear strength but shows much beneficial effects of Ductility Capacity.

Partially restrained beam-column weak-axis moment connections of low-rise steel structures

  • Lim, Woo-Young;Lee, Dongkeun;You, Young-Chan
    • Structural Engineering and Mechanics
    • /
    • v.76 no.5
    • /
    • pp.663-674
    • /
    • 2020
  • In this study, partially restrained beam-column moment joints in the weak-axis direction were examined using three large-scale specimens subject to cyclic loading in order to assess the seismic resistance of the joints of low-rise steel structures and to propose joint details based on the test results. The influence of different number of bolts on the moment joints was thoroughly investigated. It was found that the flexural capacity of the joints in the direction of weak axis was highly dependent on the number of high-tension bolts. In addition, even though the flexural connections subjected to cyclic loading was perfectly designed in accordance with current design codes, severe failure mode such as block shear failure could occur at beam flange. Therefore, to prevent excessive deformation at bolt holes under cyclic loading conditions, the holes in beam flange need to have larger bearing capacity than the required tensile force. In particular, if the thickness of the connecting plate is larger than that of the beam flange, the bearing capacity of the flange should be checked for structural safety.