• 제목/요약/키워드: High Temperature (Fire)

검색결과 770건 처리시간 0.028초

화재에 노출된 단층 돔의 후좌굴 거동에 관한 연구 (A Study on the Post-buckling Behaviour of Single-layer Domes exposed to Fire)

  • 이상진;배정은
    • 대한건축학회논문집:구조계
    • /
    • 제35권8호
    • /
    • pp.139-148
    • /
    • 2019
  • The lightweight structures such as domes are particularly vulnerable when it has been subjected to high temperature induced by the fire. It is therefore crucial to predict the possible instability path of structures exposed to the fire in structural design process. In this study, the instabilities of single-layer domes is investigated by using finite element technologies with the consideration of high temperature. The material properties of members under high temperature are considered by using the reduction factors which is provided in Eurocodes 3. Some damage patterns are assumed with use of a structural unit which is symmetric in radial direction. For numerical evaluations, the geometrically nonlinear truss element is implemented and the arch-length control method is employed to trace the post-buckling behaviour of domes. From numerical results, it is found to be that a significant change of post-buckling behaviour is detected in dome structures when structural members are exposed to the fire.

An Analytic Method for the Residual Strength Evaluation of Fire-Damaged Reinforced Concrete Beam

  • Park, Won-jun;Park, Ki-bong;Lee, Han-seung
    • Architectural research
    • /
    • 제10권2호
    • /
    • pp.37-42
    • /
    • 2008
  • This study is to get the proper evaluation of the residual property of reinforced concrete beam exposed to fire. This study focused on the strength resistance and analytical evaluation of RC members exposed high temperature. And this study is the basis analytical research to conduct the other studies. To analysis by the finite element method, the Total-RC program was used to analysis it and the Total-Temp program was also used to analysis the temperature distributions at the section. All of results were compared with the pre-existing experimental data of simple supported beam. Using it, the parameters influencing the structural capacity of the high temperature-damaged RC members and residual strength estimation are investigated. The temperature distribution and the structural capacity at the section are calculated in this step. An application of this method is compared with the heating test result and residual property test for simple supported beam which is subjected to ISO 834 test fire. The results of this study are as follows; 1) The loads-displacement relationship of RC beam, considering initial thermal stress of cross section and heat transfer analysis are estimated comparing analytical value with pre-existing experimental results. 2) by the heating time (0, 1, 2 hours), the results of analysis with parameters show that the load capacity exposing at fire is affected.

화재 상황 인식 모델을 적용한 종합 상황 판단 시스템 (Synthetic Circumstantial Judgement System Applied Recognition of Fire Levels Model)

  • 송재원;이세희;안태기;신정렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1275-1281
    • /
    • 2011
  • This paper presents synthetic circumstantial judgement system that detects and predicts a fire in subway station. Unlike conventional fire surveillance systems that judge the fire or not through smoke, CO, temperature or variation of temperature, a proposed system discovers a fire more easily or gives the alarm high possibility of fire to operator through recognition of fire levels based on Fuzzy Inference System using by FCM and information of objects from video data.

  • PDF

화재시 철근 콘크리트 보 내부 온도의 해석적 추정 (Analytical Estimation of Internal Temperature of RC Beam under Fire)

  • 이은주;신미경;강지연;신영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.548-551
    • /
    • 2004
  • The main purpose of this study is to estimate the internal temperature of RC beam under fire. For this purpose, the finite difference method was used. In the previous studies, the structural behavior of fire damaged RC beams was investigated through experiments. The result was concluded that The high temperature affects the properties of concrete such as the elastic modulus, the compressive strength. The internal temperature Estimation of the concrete is helpful for understanding the structural behavior of fire damaged RC beams. Especially, high strength concrete has more spalling than normal strength one. So, this study is performed analysis of internal temperature of RC beam considering spalling.

  • PDF

건축구조물에 적용하기위한 신개발 시멘트계 내화재료의 내화성능에 관한 연구 (Study of fire protection performance of newly developed cementitious fire protection material for application to architectural building)

  • 김장호;박해균;이명섭;원종필;임윤묵;이경민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.633-636
    • /
    • 2006
  • High-rise and large size buildings require high strength concrete and steel structure as a necessity. However, high strength concrete and steel structure are strong material but have a weakness to high temperature. Therefore, fire protection is a matter that must be considered very importantly in design for structure of high strength concrete and steel. Fire proof board that is existing method for fire proof has relatively low performance in fire protection emphasizes the need of new fire protection material due to the using of in numerable inflammables like plastics. The objective of this study is to understand the fire-resisting performance of newly developed fire protection material for building. This paper describes the results of fire tests using ISO curve that is fire protection regulation for buildings of the newly developed cementitious fire protection coating material applied concrete tunnel lining specimens.

  • PDF

고강도 콘크리트의 내화 특성에 관한 기존연구 고찰 및 실험적 연구 (State-of-the-Art Research and Experimental Assessment on Fire-Resistance Properties of High Strength Concrete)

  • 김우석;강현구;김화중
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.28-39
    • /
    • 2014
  • 본 연구에서는 우선 화재에 노출된 고강도 콘크리트의 내화특성과 폭렬 메커니즘을 규명한 기존 국내외 연구자들의 연구문헌들을 심도 깊게 고찰하였다. 그 후 고온을 받은 고강도 콘크리트에 대한 국내외 연구자들의 주요 실험 변수를 분석하여 가장 최적의 변수를 설정하였으며 이를 토대로 하여 100MPa급 고강도 콘크리트의 내화 특성을 규명하기 위한 내화실험을 계획하였다. 또한 기존 연구의 실험결과를 분석한 결과 폭렬방지에 효과가 있는 것으로 알려져 있는 PP섬유와 친수성 재료로서 시멘트 입자와 부착성능이 우수하고 워커빌리티를 개선할 수 있는 NY섬유를 혼합한 신재료 HB섬유를 섬유혼입률 0.05%로 정해 배합설계에 반영하였다. 이러한 배합설계로 타설한 총 48개의 공시체를 28일 양생기간 후 온도변화 ($100^{\circ}C{\sim}700^{\circ}C$)에 따른 고강도 콘크리트의 역학적 특성을 분석하기 위해 화재를 받은 후 냉간상태에서의 내화실험을 수행하였으며 이를 통해 고강도 콘크리트의 내화 특성을 분석하였다.

제조 방식에 따른 건축용 내화강재의 고온 시 기계적 특성 평가 (Evaluation on the Mechanical Properties of Fire Resistant Steels at High Temperature Conditions with Manufacturing Processes)

  • 권인규
    • 한국강구조학회 논문집
    • /
    • 제19권2호
    • /
    • pp.181-190
    • /
    • 2007
  • 건축용 내화강재는 화재와 같은 고열환경에 노출되었을 때 일반 구조용 강재에 비해서 내력유지 성능이 우수하도록 개발된 고성능 강재이다. 이와 같은 건축용 내화강재를 적용한 구조체가 화재에 노출되었을 때 구조적 거동을 정확하게 평가하기 위해서는 고온에서의 항복강도, 탄성계수 변화 등의 기계적 특성치가 요구된다. 따라서 본 연구에서는 압연과 TMC방식에 의한 두 가지 두께를 대상으로 건축용 내화강재의 기계적 특성 도출을 위하여 고온인장시험을 수행하였으며, 그 결과 제조방식에 따른 고온에서의 큰 기계적 특성 차이는 없는 것으로 판단되었다.

고강도 용접구조용 강재 적용 장스팬 보부재의 해석적 내화성능 비교 연구 (Comparative Study for Long Span Beams built up with Sub-marine High Strength Structural Steels at High Temperature using Analytical Method)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.120-121
    • /
    • 2016
  • Recently, the building has been changed into high-rise and long span and this yields a development of high performance structural steels in construction market. According to this effect, the SM 520 and the SM 570 were developed and utilized into steel building industry. However, the study for fire resistance of them were not done actively. In this study, to know and comparative the fire resistance performance of long span beams built up with high strength structural steels an analytical method is going to applied using mechanical and thermal properties at high temperature.

  • PDF

TMCP 내화강재의 고온 내력 평가 연구 (Evaluation of Structural Stability of Fire Resistant Steel Produced by Thermo-Mechanical Control Process at High Temperature)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.21-25
    • /
    • 2013
  • 대형화, 초고층 및 고스팬에 부응하기 위한 강재 기술개발의 노력으로 용접성능과 내진성능 그리고 내화성능이 부여된 새로운 강재인 Thermo-mechanical control process (TMCP) 내화강재가 개발되었다. TMCP 내화강재는 기존의 내화강재 생산과정 시 압연과 동시에 정밀한 열처리를 병행함으로 인장력과 용접성을 향상시킬 수 있는 새로운 기술인 TMCP 방법으로 개발되었으며, 화재와 같은 고온에서의 구조적 안전성에 관한 내력평가가 요구되었다. 따라서 본 연구에서는 고온 시 TMCP 내화강재의 내력평가를 목적으로 고온 시 항복강도, 탄성계수를 평가하고 각각에 대한 온도영역별 실험식을 제시하였으며, 이를 일반 내화강재의 고온 특성과 비교, 분석하였다. 또한 각각의 소재로 설정된 H형강 기둥부재를 대상으로 고온 시의 내력을 계산하여 그 안전성을 확인한 결과, TMCP 내화강재의 고온 시 내력특성은 일반강 내화강재의 고온 내력저하 특성보다 열위인 것으로 나타났다.

실내 내장 벽지의 고온산소지수에 대한 연구 (A Study on the Oxygen Index of Interior Wallpapers at Elevated Temperature)

  • 오규형;이성은;김황진
    • 한국화재소방학회논문지
    • /
    • 제22권2호
    • /
    • pp.57-62
    • /
    • 2008
  • 한국의 실내장식재로는 대부분 벽지를 사용하고 있다. 이러한 주거공간에 화재발생시 화재 확대요인중의 하나는 벽지의 연소를 통해 이루어진다. 그동안 산소지수 관련연구들이 많이 이루어져 왔지만 상온에서의 연구가 많았다. 본 연구에서는 실내화재에서 화재의 확대요인이 될 수 있는 벽지의 산소지수가 상온과 고온에서 얼마나 차이가 발생하며 이러한 차이가 화재확대에 미치는 영향을 고찰하고자 하였다. 실험을 통해 LOI 및 TOI 측정한 결과 벽지의 상온과 고온에서의 산소지수는 $5{\sim}8%$정도의 차이가 나타났다. 실험에서 산소지수 0.1%의 차이로도 연소 길이에 현저한 차이가 나타나기 때문에 고온에서의 산소지수 감소가 화재확대에 큰 영향을 미치는 요인임을 알 수 있었다.