• Title/Summary/Keyword: High Refractive

Search Result 478, Processing Time 0.024 seconds

Polymerization and Optical Properties of Polymers with High Tensile Strength Added Isocyanate Group

  • Sung, A-Young;Ye, Ki-Hun
    • Journal of Integrative Natural Science
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Polyurethane resin containing isocyanate is marked by excellent tensile and mechanical strengths and this test aims to gauge its applicability as a medical high polymer. Tris [2-(acryloyloxy)ethyl]isocyanurate and hexamethylenediisocyanate were added to a basic mixing ratio of HEMA (2-hydroxyethyl methacrylate), MMA (methyl methacrylate), NVP (n-vinyl-2-pyrrolidone) and crosslink agent, EGDMA (ethylene glycol dimethacrylate) with increasing proportions and copolymerized respectively. Also, the basic physical properties of the polymerized high polymers including refraction rate, tensile strength, light transmission and water content were measured to confirm that they are appropriate as hydrogelcontact lenses. After measuring the physical properties of high performance polymers produced by adding tris [2-(acryloyloxy) ethyl]isocyanurate, it was found that the average tensile strengths of sample TRIS1 to TRIS10 were between 0.285 and 0.612 kgf, while the average values of refractive index were ranged from 1.441 to 1.449 with water content from 30.00 to 37.35%.The measurement of physical properties of the copolymers generated by adding hexamethylenediisocyanate showed that the average tensile strength of sample HEXA1 to HEXA10 ranged from 0.267 to 1.742 kgf, the refractive index ranged from 1.443 to 1.475 and water contents were in the range of 21.22 to 35.58%. In all combinations the transmission rates satisfied the transmittance of general hydrogel contact lenses. From theresults, it is possible to conclude that the produced copolymers can be used as contact lens materials with excellent tensile strength.

Fabrication of Hydrophobic Anti-Reflection Coating Film by Using Sol-gel Method (Sol-gel 법을 이용한 내오염 반사방지 코팅막 제조)

  • Kim, Jung-Yup;Lee, Ji-Sun;Hwang, Jonghee;Lim, Tae-Young;Lee, Mi-Jai;Hyun, Soong-Keun;Kim, Jin-Ho
    • Korean Journal of Materials Research
    • /
    • v.24 no.12
    • /
    • pp.689-693
    • /
    • 2014
  • Anti-reflection coating films have used to increase the transmittance of displays and enhance the efficiency of solar cells. Hydrophobic anti-reflection coating films were fabricated on a glass substrate by sol-gel method. To fabricate an anti-reflection film with a high transmittance, poly ethylene glycol (PEG) was added to tetraethyl orthosilicate (TEOS) solution. The content of PEG was changed from 1 to 4 wt% in order to control the morphology, thickness, and refractive index of the $SiO_2$ thin films. The reflectance and transmittance of both sides of the coated thin film fabricated with PEG 4 wt% solution were 0.3% and 99.4% at 500 nm wavelength. The refractive index and thickness of the thin film were n = 1.29 and d = 105 nm. Fluoro alkyl silane (FAS) was used for hydrophobic treatment on the surface of the anti-reflection thin film. The contact angle was increased from $13.2^{\circ}$ to $113.7^{\circ}$ after hydrophobic treatment.

A Survey of the Visual Impairment and the Refractive Errors in Urban School Children in Korea (도시 초·중·고교 학생 시력저하 및 굴절이상에 관한 보건조사)

  • Koo, Bon Sool;Kim, Jae Chan;Yang, Han Nam
    • Journal of the Korean Society of School Health
    • /
    • v.1 no.1
    • /
    • pp.103-113
    • /
    • 1988
  • The analysis of the visual impairment and refractive errors among 4,004 school children in Seoul in 1986 with ancilliary questionnaire on various socio-environmental and visual factors was conducted. The number of the student with subnormal vision (0.7 or less) was 1,552 (38,8 %), and the rate of subnormal vision was increased with the higher grading of the school classes. Rate of myopes among the 1,552 students vision 0.7 or less consists of 52 % in primary school, 83.5 % in middle school, and 94 % in high school, and they were increased with the higher grading of the school class. The acutest increase of rates were observed at the stages of 2nd year class of male, and 1st year class of female at the middle school. Among the glasses-wearer of myopic students of vision 0.5 or less, the rate of adequately corrected cases was 42.5 %, whereas the overcorrected in 6.8 %, and undercorrected in 49.3 %. The main reasons of glasses negligence among the non-possessor of glasses with the vision of 0.5 or less were indicated in prominence of numbers of' "no complaints without glasses" (42 %). "unawareness of visual disturbance" (20%), "annoyance with wearing glasses" (13.4%), and "no permission from parents" (11.5 %) rather than the "economical reasons". The amblyopic components were estimated 126 cases (3.2%) in combination of refractive errors. According to the analysis of ancilliary questionnaire, the-conclusion with the statistical significance was that the myopization of the children's eyes appeared susceptible with a number of socio-environmental factors including the eating habits, length of T.V. watching period and distance, reading distance and type of illumination during near work, and school achievement. The possibility of prevention in some extents of progress of the myopia following the improvement of the relevant environmental factors in younger stage of children would be considered as deducible one.

  • PDF

$SiN_x$ Film Deposited by Hot Wire Chemical Vapor Deposition Method for Crystalline Silicon Solar Cells (결정질 실리콘 태양전지 적용을 위한 HWCVD $SiN_x$ 막 연구)

  • Kim, Ha-Young;Park, Min-Kyeong;Kim, Min-Young;Choi, Jeong-Ho;Roh, Si-Cheol;Seo, Hwa-Il
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.3
    • /
    • pp.27-33
    • /
    • 2014
  • To develop high efficiency crystalline solar cells, the $SiN_x$ film for surface passivation and anti-reflection coating is very important and it is generally deposited by PECVD. In this paper, the $SiN_x$ film deposited by Hot-Wire chemical vapor deposition(HWCVD) that has no plasma damage was studied. First, to optimize the $SiN_x$ film deposition process, $SiH_4$ gas rate and substrate temperature were varied and then refractive index and thickness were measured. When $SiH_4$ gas rate was 22sccm and substrate temperature was $100^{\circ}C$, refractive index was 1.94 and higher than that of other process conditions. Second, the lifetime was measured by varying the annealing temperature and time. The annealing process was made from 5 to 30 minutes at $300{\sim}500^{\circ}C$. When the annealing temperature was $100^{\circ}C$ and time was 10minute, the lifetime was the highest. The lifetime of annealed samples was also measured after the firing process at $975^{\circ}C$. Although the lifetime of all samples was decreased by firing process, the lifetime of annealed samples before the firing process was higher than that of fired samples only. Finally, the characteristics of solar cells with HWCVD $SiN_x$ film were measured.

Design of Miniaturized Wilkinson Power Divider Using Substrate Integrated Artificial Dielectric (기판적층형 가유전체를 이용한 소형화된 윌킨슨 전력분배기 설계)

  • Koo, Ja-Kyung;Lim, Jong-Sik;Ahn, Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1542-1548
    • /
    • 2009
  • This paper describes a size-reduced Wilkinson power divider using substrate integrated artificial dielectric(SIAD). SIAD transmission lines have increased effective refractive index, so the line width and length are reduced from those of standard transmission lines. Therefore the "size-reduction effect" is achieved if SIAD lines are applied to high frequency circuits. An efficient simulation method is proposed for SIAD lines which have an enormous number of via-holes. A 2GHz Wilkinson power divider is designed and measured using SIAD transmission line as an example of application. The size of the fabricated divider is reduced by 32% due to the increased effective refractive index of SIAD, while the performances are maintained similarly.

Study on SiN and SiCN film production using PE-ALD process with high-density multi-ICP source at low temperature

  • Song, Hohyun;Seo, Sanghun;Chang, Hongyoung
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1436-1440
    • /
    • 2018
  • SiN and SiCN film production using plasma-enhanced atomic layer deposition (PE-ALD) is investigated in this study. A developed high-power and high-density multiple inductively coupled plasma (multi-ICP) source is used for a low temperature PE-ALD process. High plasma density and good uniformity are obtained by high power $N_2$ plasma discharge. Silicon nitride films are deposited on a 300-mm wafer using the PE-ALD method at low temperature. To analyze the quality of the SiN and SiCN films, the wet etch rate, refractive index, and growth rate of the thin films are measured. Experiments are performed by changing the applied power and the process temperature ($300-500^{\circ}C$).

A Study on the Change of Corneal Refractive Power before and after Wearing RGP Contact Lenses by Flat Fitting and Alingment Fitting with Diagnostic Method (RGP 콘택트렌즈의 진단적 피팅법에 의한 플랫한 피팅과 얼라인먼트 피팅 착용 전·후 각막 굴절력의 변화에 관한 연구)

  • Lee, Dae-Won;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Purpose: This study is for compared the change of corneal refractive power before and after wearing of rigid gas permeable contact lense with diagnostic method which is 1 D flatter than alignment fitting on right eye and alignment fitting on left eye for 2 months and investigate the preference. Methods: Twenty middle school and high school students (40 eyes) who had never worn a contact lense before for no corneal topographical change, no ocular disease, no experience of ophthalmic surgery and have normal tear amount were selected for this study and corneal refractive power were examined before wearing rigid gas permeable contact lense and adaptation status and corneal examination were performed after 10 days of wearing and after cheking up the continuation of wearing, all candidate wear contact lens 8 hours per day for 2 month and corneal refractive power were compared. Results: After 2 months of wearing with 1 D flatter than the alignment fitting on right eyes, there was significant difference in the central corneal refractive power was $43.84{\pm}1.33D$, flat K power was $43.05{\pm}1.29D$, and steep K power was $44.61{\pm}1.42D$ decreased than before wearing (p<0.001, 0.001, 0.047). The e-value of the principal meridians also shows statistically significant difference (p=0.037, 0.015). After 2 months of wearing with alignment fitting on left eyes, the central corneal refractive power was $44.40{\pm}1.26D$, flat K power was $43.57{\pm}1.23D$. and flat K e-value was $0.58{\pm}0.05$ which showed no statistically significant difference (p = 0.769, 0.614, 0.181). But steep K power was $45.25{\pm}1.36$, and steep K e-value was $0.45{\pm}0.18$ which shows statistically significant difference (p=0.018, 0.027). Conclusions: Consider the comfort, clear vision, dryness for preference fitting investment, 6 students (30%) prefer right eye which is 1 D flatter fitting, 14 students (70%) prefer left eye which is alignment fitting. For rigid gas permeable fitting needed for accurate examination and should prescribe the alignment fitting which is suitable for each cornea.

Reliability of Autorefractometry after Corneal Refractive Surgery (레이저 굴절교정수술 후 자동굴절검사법의 신뢰성)

  • Lee, Ki-Seok
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.443-451
    • /
    • 2018
  • Purpose : To find out the reliability of autorefractometer after laser refractive surgery Methods : We measured and compared spherical and cylinder powers of those undergone LASEK surgery with 1.0 of naked vision after at least 3 months of the surgery with an autorefractometer(CANON Full Auto Ref-Keratometer RK-F1, Japan) and a retinoscope(Streak Retinoscope 18200, WelchAllyn, USA), and also applied spherical equivalent powers. The refractive status before surgery was divided into high, medium, and low myopia according to the results measured using an autorefractometer, and then analyzed again the reliability of the autorefractometer after surgery according to the preoperative refractive status. The agreement of two methods was identified using Bland-Altman(Bland-Altman limits of agreement(LoA)). Results : After the surgery, when comparing spherical, cylinder and equivalent powers in the whole data measured by autorefractometry and retinoscopy significant differences were found(p<0.01). According to the degree of refractive errors, all sort of refractive errors was shown significantly different(p<0.01) except for cylinder power of the medium myopia. In general, the refractive errors especially spherical and spherical equivalent powers by autorefractometry were shown a myopic trend from -0.38 D to -0.53 D. On the other hand, it was shown a hyperopic trend of approximately +0.30 D using retinoscopy. In comparison of two objective refractions, it was shown a myopic trend as $-0.51{\pm}0.45D$(LoA +0.36 D ~ -1.39 D) and compatible. Conclusion : Even though it would be positive in terms of compatibility of the methods, it is necessary that the glasses should be prescribed by subjective refraction since autorefractometry is shown myopic in those undergone the surgery and suffering from myopic regression.

Relationship on the Refractive Status of the High School 3rd Grade Students with Subnormal Visual Acuity in Gwangju Metropolitan City (광주지역 고등학교 3학년생의 비정시안의 굴절상태에 대한 고찰)

  • Yoon, Young;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • To investigate the ametropia and refractive error of 222 ametropic eyes of the 111 high school students in Gwangju Metropolitan City, the visual acuity test was performed by the object and subject method. 85% of the eye types were positive for myopia, 14% for emmetropia, and 1% for hyperopia, respectively. 38% of the abnormal refraction eyes were positive for simple myopia, 4% for myopia simple astigmatism, 56% for myopia compound astigmatism, and 0% for simple hyperopia, 0% for hyperopia simple astigmatism, 2% for hyperopia compound astigmatism, 0% for mixed astigmatism, respectively. 92% of the axes fo astigmatism were for astigmatism with-the-rule, 6% for astigmatism against-the rule, 2% for astigmatism oblique, respectively. As for the astigmatic power, 0.50 < cylinder < 1.00D was 68%, 1.00 < cylinder < 2.00D was 25%, and anything over the 2.00 cylinder D was 7%. As for the equivalent spheric power of myopic abnormal refraction eyes, -0.50 < spheric equivalent < -2.00D was 26%, -2.00D < spheric equivalent < -6.00D was 55% and anything over the -6.00D was 19%. The rate of wearing glasses was 74%. It increases compared to 20 years ago. 91% of the eye test place was the optical shop, 9% the eye doctor hospital. 80% of the students need to change their optical lenses because spherical equivalent power was over 0.50D.

  • PDF

Comparison of the Refracting Power and Aberration according to the Measurement Change in Illumination and Area of the Pupils (조도와 동공 영역의 측정 변화에 따른 굴절력과 수차의 비교)

  • Kim, Bong-Hwan;Han, Seon-Hee;Park, Byeong-Gyu;Hwang, Hyeon-Ju;Bae, Ye-Sol;Seo, Jeong-Bin;Yeo, Ye-Eun;Yoon, Min-Jeong;Kim, Hak-Jun
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.2
    • /
    • pp.550-555
    • /
    • 2016
  • Purpose. We compared with the refracting power and aberration according to the measurement change in illumination and the pupils area by using the auto refraction instruments. Methods. In this study it were examined 64 eyes without eye disease, 21.4 (${\pm}2.54$) age, 32 (male 10, female 22) patients. Experiments in general illumination using the auto refraction instruments (HRK-8000A, Huvitz, Korea) was measured in both eyes 3 times and after scotopic for 30 minutes in a dark room blocked the light was measured in the same way. Aberration were measured coma, spherical aberration, high and low order aberrations in a general illumination (3500 lux) and low illumination (5 lux) of the pupil area 3.96 mm and 5.96 mm. Results. In the general illumination for measuring of the pupil area, the refractive power, coma, spherical aberration and low order aberration was no significant difference. In the low illumination, spherical aberration of the pupil area was $0.005({\pm}0.015){\mu}m$ in a 3.96mm, $0.014({\pm}0.020){\mu}m$ in a 5.96 mm and appeared a significant difference(p = 0.003). In general and low illumination on the results of comparing the measured values of the refractive power and aberration at the pupil area 3.96 mm, high order aberrations was $0.205({\pm}0.145){\mu}m$ in general illumination, $0.132({\pm}0.075){\mu}m$ in low illumination and appeared a significant differences(p = 0.001). High order aberrations at the pupil area 5.96 mm was $0.278({\pm}0.244){\mu}m$ in general illumination, $0.150({\pm}0.092){\mu}m$ in low illumination and appeared a significant differences(p = 0.000). Conclusions. When the eye refractive power measured by the automatic refraction does not depend on the illumination conditions and size of the observation pupil area, it was found that aberrations are affected by the illumination and the observation pupil area. It was found that the eye examination chamber illumination to obtain accurate measurement produces better results to decrease than to increase.