• 제목/요약/키워드: High Pulse pressure

Search Result 313, Processing Time 0.039 seconds

Elevation of heart-femoral pulse wave velocity by short-term low sodium diet followed by high sodium diet in hypertensive patients with sodium sensitivity

  • Rhee, Moo-Yong;Kim, Ji-Hyun;Na, Sang-Hoon;Chung, Jin-Wook;Bae, Jun-Ho;Nah, Deuk-Young;Gu, Namyi;Kim, Hae-Young
    • Nutrition Research and Practice
    • /
    • v.10 no.3
    • /
    • pp.288-293
    • /
    • 2016
  • BACKGROUND/OBJECTIVES: We compared changes in heart-femoral pulse wave velocity (hfPWV) in response to low sodium and high sodium diet between individuals with sodium sensitivity (SS) and resistance (SR) to evaluate the influence of sodium intake on arterial stiffness. SUBJECTS/METHODS: Thirty-one hypertensive and 70 normotensive individuals were given 7 days of low sodium dietary approach to stop hypertension (DASH) diet (LSD, 100 mmol NaCl/day) followed by 7 days of high sodium DASH diet (HSD, 300 mmol NaCl/day) during 2 weeks of hospitalization. The hfPWV was measured and compared after the LSD and HSD. RESULTS: The hfPWV was significantly elevated from LSD to HSD in individuals with SS (P = 0.001) independently of changes in mean arterial pressure (P = 0.037). Conversely, there was no significant elevation of hfPWV from LSD to HSD in individuals with SR. The percent change in hfPWV from the LSD to the HSD in individuals with SS was higher than that in individuals with SR. Subgroup analysis revealed that individuals with both SS and hypertension showed significant elevation of hfPWV from LSD to HSD upon adjusted analysis using changes of the means arterial pressure (P = 0.040). However, there was no significant elevation of hfPWV in individuals with SS and normotension. CONCLUSION: High sodium intake elevated hfPWV in hypertensive individuals with SS, suggesting that high sodium intake increases aortic stiffness, and may contribute to enhanced cardiovascular risk in hypertensive individuals with SS.

Rupture Prediction of the Rupture Disk Using Elasto-Plastic Analysis (탄소성해석을 이용한 파열판의 파열예측)

  • Han, Houk-Seop;Lee, Won-Bok;Koo, Song-Hoe;Lee, Bang-Eop
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.3
    • /
    • pp.49-56
    • /
    • 2012
  • Rupture disks are a kind of safety device in high pressure equipment and they are used to control rupture pressure in the solid rocket motor. In this paper, a series of rupture experiments was performed using rupture disks made of AISI 316L and rupture pressure of rupture disks was calculated through various assumptions in relation between elasto-plastic material properties and true stress-strain curve. Experiment and FEA indicated rupture pressure is determined by size of rupture disks. As a result of elasto-plastic analysis, only multi-linear stress-strain curve was able to calculate meaningful estimations. Experimental results also showed rupture location are decided by the size of rupture disks. Experimental and FEA results will be applied to control rupture pressure of disks.

A Non-Invasive Ultrasonic Urinary Bladder Internal Pressure Monitoring Technique: Its Theoretical Foundation and Feasibility Test (비침습적 초음파 방광 내압 측정 기술: 이론적 기초 및 실현 가능성 평가)

  • Choi, Min Joo;Kang, Gwan Suk;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.526-539
    • /
    • 2012
  • A new approach was proposed in this article, named, a non-invasive ultrasonic method to monitor the urinary bladder internal pressure which can resolve the shortcomings of the existing methods. The proposed method makes use of acoustic cavitation. It is based on a physical phenomenon that an extracorporeal high intensity focused ultrasonic pulse generates bubbles inside the urinary bladder and the dynamic properties of the bubbles are related to the urinary bladder internal pressure. The article presents the theoretical foundation for the proposed technique and verifies its feasibility with preliminary experimental data. The suggested ultrasonic urinary bladder internal pressure monitoring method is non-invasive and can be used any time regardless of sex and age, so that it will be of a great benefit to the diagnosis and therapy of urination related diseases.

Design of U-healthcare System for Real-time Blood Pressure Monitoring (실시간 혈압 모니터링 u-헬스케어 시스템의 설계)

  • Cho, Byung-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.161-168
    • /
    • 2018
  • High blood pressure is main today's adult disease and existing blood pressure gauge is not possible for real-time blood pressure measurement and remote monitoring. But real-time blood pressure monitoring u-healthcare system makes effect health management. In my paper, for monitoring real-time blood pressure, an architecture of real-time blood pressure monitoring system which consisted of wrist type-blood pressure measurement, smart-phone and u-healthcare server is presented. And the analog circuit architecture which is major core function for pulse wave detection and digital hardware architecture for wrist type-blood pressure measurement is presented. Also for software development to operate this hardware system, UML analysis method and flowcharts and screen design for this software design are showed. Therefore such design method in my paper is expected to be useful for real-time blood pressure monitoring u-healthcare system implementation.

Verification of lavender(Lavandula angustifolia cv.Hidcote) and lawn(Zoysia japonica Steud.)'s Curative Effect, as a Green Space Composition Factor (녹지구성 인자로써 라벤더(Lavandula angustifolia cv.Hidcote)와 잔디(Zoysia japonica Steud.)의 치유적 효과)

  • Yutaka, Iwasaki;Kim, Yu-Yeong;Cho, Tae-Dong
    • Journal of Environmental Science International
    • /
    • v.21 no.12
    • /
    • pp.1487-1494
    • /
    • 2012
  • This study has been carried out to verify curative effect of lavender and lawn, a green space composition factor. Thus, the physiological index value of blood pressure, heart rate and salivary amylase were measured with object of 16 women in their 20~30s for stress relaxation effect at lavender garden and lawn square, and impression assessment upon SD method as for psychological value was performed in this study. And a survey was conducted on necessity and reason of urban green space with object of 345 men and women urban workers. As a result of variance analysis between groups and multi test of Turkey upon object place, the blood pressure was lowered the same at lavender garden and lawn square, and especially, high blood pressure was greatly lowered to 30 mmHG at lavender garden. On the other hand, low blood pressure group showed the tendency of a little increasing at the same places. And for the pulse, there was difference between high blood pressure group and normal group at the same places. To conclude, at lavender garden and lawn square the blood pressure was made to be lowered when it's high, and when it's low, the effect of returning to sound status, the function of increasing, was verified. In case of impression assessment upon SD method, the lawn square was assessed as resting place and lavender garden diversional place. And over 90% of urban workers responded to the green space's necessity and curative effect, diversion and resting place were adopted for the reason in high-ranking items. As above the green space pattern that urban workers require and curative effect of lavender garden and lawn square were verified. Therefore, the functional green space plan is required, which curative effect, diversion and resting place are considered, for the future green space plan design.

Adaptive Pressure Sensor with High Sensitivity and Large Bandwidth Based on Gallium Microdroplet-elastomer Composite (갈륨 미세입자 탄성 복합체 기반 고민감도와 광대역폭을 갖는 가변 강성 압력센서)

  • Simok, Lee;Sang-Hyuk, Byun;Steve, Park;Joo Yong, Sim;Jae-Woong, Jeong
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.423-427
    • /
    • 2022
  • A pressure sensor that mimics the sensing ability of human skin has emerged as high-profile technology because it shows remarkable applications in numerous fields such as robotics, human health monitoring, and artificial prosthetics. Whereas recent pressure sensors have achieved high sensitivity similar to that of human skin, they still show limited detection bandwidth. Moreover, once these e-skin are fabricated, their sensitivity and stiffness are fixed; therefore, they can be used for only limited applications. Our study proposes a new adaptive pressure sensor built with uniform gallium microdroplet-elastomer composite. Based on the phase transition of gallium microdroplets, the proposed sensor undergoes mode transformation, enabling it to have a higher sensitivity and wider detection bandwidth compared with those of human skin. In addition, we succeeded in extending a single adaptive pressure sensor to sensor arrays based on its high uniformity, reproducibility, and large-scale manufacturability. Finally, we designed an adaptive e-skin with the sensor array and demonstrated its applications on health monitoring tasks including blood pulse and body weight measurements.

Characteristic Radial Pulse Properties of Elderly Females according to Sasang Constitution-based Health Level (고령자 여성의 체질건강수준에 따른 맥파 특성 연구)

  • Kim, Jae Uk;Bae, Jang Han;Ku, Bon Cho;Jeon, Young Ju;Kim, Keun Ho;Kim, Jong Yeol;Kim, Young Min
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.6
    • /
    • pp.970-975
    • /
    • 2012
  • In Sasang constitutional medicine, doctors diagnose and treat patients according to their Sasang consitutition (SC) type. In this work, by a clinical test with a radial pulse tonometer, we investigated radial pulse properties which were significant in distinguishing unhealthy subjects from healthy subjects for each SC type. We measured radial pulse properties on left and right Gwan locations with a pulse tonometer for 299 elderly female subjects of age of 50 years old or above. We used a newly developed SCAT system to determine subjects' SC types. Subjects' health levels of either healthy or unhealthy were determined independently by two Korean medical doctors. To investigate the statistical differences, we used either of Student's t-test or Mann-Whitney U test depending on the normality of distribution of test statistic. For TE type, unhealthy subjects were characterized with significant increases in heart rate, systolic to diastolic period, pulse depth, while they showed significant decreases in width of pulse in normal direction, pulse area in diastolic period, and high harmonic components (6th, 7th) of power spectral density. For SE type, unhealthy subjects were characterized with significant increases in pulse pressure and pulse depth, while no significant differences were found for SY type. We investigated the characteristic differences in radial pulse properties due to change in health levels on each SC type for elderly females. Pulse variables which were significantly different between healthy subjects and unhealthy subjects were found to vary between SC types. For TE type subjects, many variables were found significant at the left Gwan location, which is in support of the theory of hyperactive liver functioning for TE type. Irrespective of the constitution, the related changes in the pulse properties due to worsened health level were in support of elevated blood flow amount in compensation with weakened blood circulatory function.

Analysis of Research Trends in Physiological Variables in Complementary and Alterative Therapy(CAT) in Korean Nursing (보완대체요법 논문에서 생리적 변수를 다룬 연구에 대한 분석)

  • Byeon, Young-Soon;Oak, Ji-Won
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.13 no.2
    • /
    • pp.275-284
    • /
    • 2006
  • Purpose: The purpose of this study was to analyze tile trends in physiological variables in CAT research in nursing in Korea. Method: Of studies published in Korea between January, 2000 and December, 2005, 227 studies were analyzed according to the criteria of type, theme, and patterns in physiological variables related to CAT. Results: There were 72 articles on CAT research in which physiological variables were examined. The most frequently researched type of CAT was massage and in particular, foot massage. The most frequently used physiological variables in CAT research were blood pressure, pulse, and body temperature. Patients with high blood pressure were the most frequent subjects for CAT research. As to the effect of physiological variable by CAT type, foot massage showed a decline in blood pressure in all six research studies involving patients with high blood pressure. Conclusion: There is a need to describe accurately the mechanism by which CAT affects physiological variables. There is also a need for repetitive analysis to verify the effect, and meta-analysis for the effect on physiological variables according to type of CAT.

  • PDF

Studies on the Physical Fitness of the Middle and High School Boys (성장기 한국인 남녀 기초체력 향상에 관한 연구 (남자 중.고등학생을 대상으로 하여))

  • Chae, E-Up;Kim, Kyu-Soo;Choo, Young-Eun;Kim, Chong-Suck;Woo, Won-Hyung;Chung, Pock-Tuck
    • The Korean Journal of Physiology
    • /
    • v.4 no.2
    • /
    • pp.5-17
    • /
    • 1970
  • The effects of Physical exercise, gymnastics and sports on the cardiopulmonary function were studied in the middle and high school toys. The subjects were divided into 4 groups; non-training group and training group in both middle school and high school boys. In the above groups, pulmonary function studies were performed, and blood pressure and the heart rate were also checked to evaluate physical fitness during and immediately after running exercise on the tread-mill, with the speed of 5 MPH and elevation of 9% and 11.25%. The types of sports in the training group were base ball, body building, Taekwondo (Korean style boxing) and hand ball. The results obtained were as followings: 1) In the training group, cardiopulmonary function showed some tendency of the increase comparing to the non-training group. 2) The increase in cardiopulmonary function was observed according to the age became older, but the clear changes on cardiopulmonary function was not observed as the difference of the group between the training and the non-training. 3) The expiratory volume was decreased as the increase of age except 17 years of age for the value of the per kg body weight. 4) In the non-training group, the mean value of oxygen consumption under maximum work load was increased, while those in the training group was decreased. But it may be noted that oxygen consumption for the expiratory volume was increased in the training group, and that the oxygen cost in the training group was .higher than that of the non-training group. 5) The pulse pressure of the high school group during and immediately after running exercise was observed in the higher value comparing with that of the middle school group It was suggested that the changes of the pulse pressure was owing to the method of determination and that to the decrease of diastolic pressure caused by the decrease of peripheral vascular resistance up to critical closing pressure. 6) Any differences of the changes in the heart rate between the training group and non-training group was not observed during and immediately after running exercise. 7) The relative value of the expiratory volume to the heart rate was decreased in the elder age group.

  • PDF

Discharge characteristics of a Flat Fluorescent Lamp(FFL) contanining Penning gases

  • Lee, Sang-Mok;Cho, Yong;Jung, Sang-Kooun;Jeong, Byoung-Hyun;Jeong, Yun-Cheol;Kwak, Min-Gi;Sohn, Sang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.675-678
    • /
    • 2006
  • We developed a Flat Fluorescent Lamp(FFL) with a high luminance by using the same discharge mode as PDP. Our FFL has the simple and unique structure where the glass substrates are used as dielectric layers. The panel has a striped line shape of 7 inch diagonal size. The Xe-Ne-He mixture gas was used to generate the plasma, and the gas discharge characteristics under both total gas pressure and partial gas pressure were investigated. The panel showed a maximum high luminance $7,270cd/m^2$ under bias of 20KHz pulse of 3KV.

  • PDF