• Title/Summary/Keyword: High Numerical Aperture

Search Result 75, Processing Time 0.024 seconds

Aspherical Lens Manufacturing Technology in the Optical Storage Device (광 정보 저장 장치에서의 비구면 렌즈 가공 기술)

  • 이호철;김대식;이철우;김부태;양민양
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.964-967
    • /
    • 2001
  • Aspherical lens with the higher numerical aperture has been needed in the optical storage device to increase the recording density on the disk. However, high numerical aperture means the large slope angle at the clear aperture of the lens. Therefore, the measurement and manufacturing technique including the lens molding process for the slope angle should be developed. In this paper, the evaluation technique was described for the optical performance of the aspherical lens. Aspherical form error brings about the wavefront error and the side lobe of the beam intensity profile. A schematic diagram of the aspherical lens manufacturing was drawn to explain the aspherical form error compensation. Finally, form error of the aspherical lens was defined and plotted using the raw data of the Formtalysurf.

  • PDF

Fabrication and Properties of PbO Contained Multicomponent Glass Fiber (PbO함유 다성분계 Glass Fiber의 제조 및 특성평가)

  • 이회관;오영석;이용수;박만규;강원호
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.89-93
    • /
    • 2002
  • PbO contained multicomponent glass and fibers have been obtained by melting process and double crucible method. PbO containing glass is most promising for fabrication of high-numerical aperture optical fiber. In this study, main composition is $SiO_2$, PbO and glass composition mix component oxide such as $K_2O$, $Na_2O$, $B_2O_3$, $A1_2O_3$. Also, the optical, mechanical and structural properties of manufactured fibers by double crucible method are investigated.

  • PDF

3D Measurement of TSVs Using Low Numerical Aperture White-Light Scanning Interferometry

  • Jo, Taeyong;Kim, Seongryong;Pahk, Heuijae
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.317-322
    • /
    • 2013
  • We have proposed and demonstrated a low numerical aperture technique to measure the depth of through silicon vias (TSVs) using white-light scanning interferometry. The high aspect ratio hole like TSV's was considered to be impossible to measure using conventional optical methods due to low visibility at the bottom of the hole. We assumed that the limitation of the measurement was caused by reflection attenuation in TSVs. A novel interference theory which takes the structural reflection attenuation into consideration was proposed and simulated. As a result, we figured out that the low visibility in the interference signal was caused by the unbalanced light intensity between the object and the reference mirror. Unbalanced light can be balanced using an aperture at the illumination optics. As a result of simulation and experiment, we figured out that the interference signal can be enhanced using the proposed technique. With the proposed optics, the depth of TSVs having an aspect ratio of 11.2 was measured in 5 seconds. The proposed method is expected to be an alternative method for 3-D inspection of TSVs.

Theoretical and Numerical Lens Design Using Near Field Theory for High Density Storage Device (근접장 이론을 이용한 고밀도 저장 장치용 렌즈의 이론적 설계와 수치적 설계)

  • 이문도;박재혁;박노철;박영필
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.9
    • /
    • pp.173-179
    • /
    • 2003
  • In optical storage device system, there are several research topics to increase its recording density. The main idea is reducing wave length of laser diode and magnifying the number of numerical aperture (NA). In conventional optical system NA cannot be over the unity in the air because of its diffraction limit. But it is possible to overcome its limitation of unity in near field using Solid Immersion Lens. In this work, the mathematical Solid Immersion Lens (SIL) design process was illustrated by using near field theory. Also, numerical SIL design parameters were calculated by means of CODE V. Through the work, we propose the new type of SIL for high density optical recording systems.

A STUDY OF HYDRAULIC PROPERTIES IN A SINGLE FRACTURE WITH IN-PLANE HETEROGENEITY: AN EVALUATION USING OPTICAL MEASUREMENTS OF A TRANSPARENT REPLICA

  • Sawada, Atsushi;Sato, Hisashi
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • Experimental examinations for evaluating fracutres were conducted by using transparent replicas of a single fracture in order to obtain the fracture data to contribute to the methodlogy on how to improve the definitaion of representative parameter values used for a parallel plate fracture model. Quantitative aperture distribution and quantitative tracer concentration data at each point in time were obtained by measuring the attenuation of transmitted light through the fracture in high spatial resolution. the representative aperture values evaluated from the multiple different measurement methods, such as arithmetic mean of aperture distribution measured by the optical method, transport aperture evaluated from the tracer test, and average aperture evaluated from the fracture void volume measurement converged to a unique value that indicates the accuracy of this experimental study. The aperture data was employed for verifying the numerical simulation under the assuption of Local Cubic Law and showed that the calculated flow rate through the fracture is 10%-100% larger than hydraulic test results. The quantitative tracer concentration data is also very valuable for validating existing numerical code for advection dispersion transport in-plane heterogeneous fractures.

Ultra-precision High Numerical Aperture Plastic Objective Lens for Blu-ray Disc Pick-up (블루레이 디스크 픽업용 초정밀 고개구율 플라스틱 대물렌즈)

  • Kim, Boo-Tae;Hyun, Dong-Hoon;Yoo, Kyung-Sun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.6
    • /
    • pp.811-816
    • /
    • 2011
  • We develop a plastic object lens for blu-ray disc playing pick-up module as morethan 0.85 numerical aperture in this research. We design plastic object lens for blu-ray disc playing pick-up module's each factor's in balanced and made our designed lens by injection molding. Furthermore, by correction designing in mold-core, we optimization our lens efficiency as world grade; wave front aberration $0.028{\lambda}$. RMS, light axis differential 0.3967arcmin. We can manufacture localized blu-ray disc's pick-up lens's component and by this fact we obtain international competitiveness. The result of this research will be very helpful to develop a single objective lens for 3 different wavelength of laser diodes in playing and recording pick-up module.

Experimental Study on Spin Coated Thin Cover Layer for High Numerical Aperture Optical Disc

  • Dohoon Chang;Myongdo Ro;Duseop Yoon;Park, Insik;Dongho Shin;Kim, Jinhwan
    • Macromolecular Research
    • /
    • v.9 no.6
    • /
    • pp.313-318
    • /
    • 2001
  • The present study relates to a method of manufacturing 100$\mu\textrm{m}$ thick cover layer for the high density digital versatile disc system (HD-DVD), which uses a high numerical aperture of 0.85 at 405 nm wavelength. Spin coating technique was investigated as means for manufacturing the cover layer within sufficient margins of thickness variation and with good mechanical properties including small radial and tangential tilts. The influence of processing variables such as spinning speed, spinning time, and dispensing position was investigated. The effect of viscosity of UV-curable resin was also investigated.

  • PDF

Study on Manufacturing Aspheric Lens Array with High NA using Reflow Phenomenon (리플로우 현상을 이용한 고 개구수를 갖는 비구면 렌즈 어레이의 제작에 관한 연구)

  • 김완진;이명복;손진승;박노철;박영필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.644-647
    • /
    • 2003
  • Resulting from reproducibility and possibility of mass production. many researches to fabricate micro lens array using lithography have been developed. However, it still remains the level of fabricating compensation lens. Therefore, to realize the fabrication of lens having high numerical aperture can be the key technology of ultra slim optical system. Reflow phenomenon have been researched to make lens having high refractive power. And through those researches, the possibility to fabrication of high refractive power lens has been investigated. In this paper, we analyze the effect of many parameters in reflow process to get an aspheric shape with high repeatability. And we make possible to estimate shape error, through we give direct information about decrease in volume of photoresist.

  • PDF

Optical Design of a High-numerical-aperture Objective with a Reflective Focal Reducer (반사형 Focal Reducer를 가지는 높은 개구수의 대물렌즈 설계)

  • Jong Ung Lee
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.6
    • /
    • pp.248-260
    • /
    • 2023
  • A 0.5-numerical-aperture (NA) refractive-reflective objective, composed of a low-NA refractive and a reflective focal reducer, is designed. A 0.25-NA Lister objective is used for the refractive. A two-spherical-mirror system, corrected for spherical aberration, coma, and astigmatism is used for the reflective focal reducer. In spite of high NA, the refractive-reflective objective has an 18-mm working distance and improved imaging performance, compared to the 0.25-NA Lister objective.