• Title/Summary/Keyword: High Line

Search Result 8,107, Processing Time 0.042 seconds

Branch line directional coupler with coupled lines (결합 선로를 이용한 브랜치 선로 방향성 결합기)

  • Han, Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.286-291
    • /
    • 2011
  • Directional couplers are widely used in RF and microwave applications to distribute or monitor signals. This paper presented a new structure of microstrip branch line directional coupler with coupled lines. The loose couplings of microstrip branch line directional couplers are impractical for the high characteristic impedance values required for the shunt branches. To overcome this limitation, the parallel coupled lines with the shorts were used for the high characteristic impedance. The results of the simulations and measurements were presented for the proposed branch line directional coupler. Measurement of the 10 dB branch line directional coupler shows that the return loss is higher than 30 dB over 10 % bandwidth and the isolation is 35 dB or better over 8 % bandwidth.

Transmission Cost Allocation Considering Reliability Cost (신뢰도 비용을 고려한 송전요금 할당)

  • Park, Yeong-Hyeon;Kim, Dong-Min;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.576-581
    • /
    • 2008
  • Electricity Market in Korea can't provide locational price signal through energy price because energy market is CBP(Cost Based Pool) using uniform price. Generators don't want to locate in a densely populated load area(like the metropolitan area). Because they are paid more fixed cost in metropolitan area. This situation has loss and congestion occurred in power system. However energy market without price signal can't lead generator to the metropolitan. So, market participants should be provided price signal through the transmission price instead of energy price. This paper proposes transmission pricing method considering reliability cost in order to offer price signal. Also, it proposes the method to allocate the transmission cost to each transmission line user through a fair and a reasonable manner. The transmission price is decided by the reliability value of each line. If a transmission line of high reliability value is broke, users using that line will get a loss and a discomfort. So, it is fair that users using a transmission line of high reliability value pay more than the other users. Also, it is reasonable that a transmission line owner get paid more form users using that line.

A Study on Overall Measurement System Development of HEMU-400X Performance Test (차세대고속열차 성능시험을 위한 종합계측시스템 개발 연구)

  • Lee, Young-Yeob;Ryu, Sang-Hyun;Kim, Bong-Rae;Kim, Kyung-Taek
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1118-1123
    • /
    • 2011
  • The introduction of high speed railway(KTX) in Korea after the Korean high speed train through the KTX-II of the development is being run is made. Thus the demand for the railway technology advances and high performance, Korean government promoted the development of the next-generation high speed train system(HEMU-400X). In addition to the production of train system essential element of the train through an on-line test is to evaluate the performance. Through the on-line test of the train in order to evaluate the performance test items should be selected first and need to the test procedures are required. In addition, an Overall Measuring System(OMS) to measure the performance of the train system should be established. In this study for the on-line test of the HEMU-400X test items was selected for detailed measurements and performance evaluation of a comprehensive and efficient trains to test an OMS for the development are discussed.

  • PDF

A Study on Specification of Hardware and Insulator for 400km/h Class High-speed Railway (400km/h급 고속철도용 금구 및 애자사양에 대한 고찰)

  • Cho, Ho-Ryung;Lee, Ki-Won;Kwon, Sam-Young;Cho, Young-Hyeon;Lee, Sang-Sik
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1444-1452
    • /
    • 2011
  • At present, Kyungbu high-speed railway is operated with 300km/h, Honam high-speed railway is being constructed with 350km/h, and the development for the overhead contact line system is to be conducted for the next-generation high-speed railway with the speed of 400km/h. It is necessary to set up the specification and criteria for the key parts such as dropper, termination clamp and tension insulator for the 400km/h railway line. In this paper, the specification and the criteria for dropper, termination clamp and tension insulator has been reviewed and proposed in order to secure long-term reliability and stability under the maximum speed of 400km/h. Also, the specification, criteria and international standards for 300km/h class and 350km/h class railway line system and the international standards related with the insulators have been reviewed, compared and analysed.

  • PDF

Ground vibration predictions based on the combination of measurements and simulations (현장계측 및 시뮬레이션 조합에 의한 철도지반진동예측기법 개발)

  • Yang, Sin Chu;Hwang, Sung Ho;Jang, Seung Yup;Kim, Eun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.366-370
    • /
    • 2014
  • Considering a countermeasure against vibration along the existing line, in many cases, it may be the most efficient method to replace existing fasteners with high resilient fasteners because of the restriction of the construction of a new track type. There are many types of high resilient fasteners which are different in price and performance. Therefore it is important to choose the high resilient fastener which has best vibration-proof performance per price. In this study, a prediction method which can exactly evaluate the performance of a fastener in the reduction the ground borne noise in the existing line is presented, which is constructed based on the combination of the measurement and the simulation. A numerical example using the presented method is introduced to evaluate the vibration-proof performance for the solution of the vibration problem in the existing line.

  • PDF

Analysis on causes of Faults in damaged Bell Crank of High Speed Line Turont (고속 분기기의 벨 크랭크 파손에 따른 장애 원인 분석)

  • Kim, Yong-Kyu;Baek, Jong-Hyun;Kim, Jong-Ki
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1369-1374
    • /
    • 2007
  • We carried out a vibration test to analyze causes of the damage in the plate of Bell Crank of the high speed Line turnout, at the section where the plate of high speed railway turnout get damaged from May 8th to 9th in 2006. In addition, through a test of the material quality, we performed an analysis of the qualities (of the components) composing the plate. The result indicates that the main cause of faults of the high speed line turnout, which is installed in the section of Chil-gok IEC, is the vibration. In this paper, effects on track-side equipments from vibration, and measurements to protect them from it are mainly analyzed and checked.

  • PDF

Boundary Current Mode Operated Bridgeless Boost Converter for Power Factor Correction (역률개선을 위해 경계전류모드로 동작하는 브리지리스 부스트 컨버터)

  • Yu Byung-Gyu;Lee Sung-Se;Han Sang-Kyu;Moon Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.90-94
    • /
    • 2003
  • Recently, many nations have released standard such as IEC 1000-3-2 and IEEE 519 which impose a limit on the harmonic current drawn by equipment connected to AC line in order to prevent the distortion of an AC line. Among the wide variety of active methods for improving power factor and harmonic distortion, the boost converter is very effective because it has a continuous line current , small choke filter and high power factor. In high power application, however, the bridge diode loss in the boost converter has made the efficiency lower and the temperature of the board higher. A new approach without bridge diode to make the same characteristics of the conventional boost converter has also been developed. This paper present the comparisons between the continuous current mode(CCM) operated conventional boost converter and the boundary current mode(BCM) operated the bridgeless boost converter for high efficiency and high power factor.

  • PDF

Development of a Measurement System Development for On-Line Testing of High Speed Railway (고속철도 시운전시험 계측시스템 개발에 관한 연구)

  • 김석원;김영국;한영재;박찬경;김진환;백광선
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.3
    • /
    • pp.158-166
    • /
    • 2002
  • In this paper, we introduce the software and hardware of the measurement system for on-line testing and evaluation of high speed railway. The test items focus on the verification of the performance and acquirement of the technical data of the high speed railway system. The software controls the hardware of the measurement system, perform the analysis and calculation of measurement data and acts as interface between users and the system hardware. For this purpose, three programs a measuring program, a monitoring program and post-processing program are developed. The detailed test scenario is in the process of development to closely follow the process of development and design of the system.

High precision 3-dimensional object measurement using slit type of laser projector (슬리트형 레이저 투광기를 이용한 고정밀 3차원 물체계측)

  • Kim, Tae-Hyo;Park, Young-Seok;Lee, Chuy-Joong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.6
    • /
    • pp.613-618
    • /
    • 1997
  • In this paper, we designed a line CCD camera for a flying image, which is composed of a line CCD sensor(2048 cells) and a rotating mirror, and investigated its optical properties. We also made the 3-D image from the flying image which is made of 2-D image being juxtaposed to 1-D images obtained by the camera, and performed the calibration to acquire high precision 3-D data. As a result, we obtained the 3-D measurement system using the slit type of laser projector is available to measure the high precision shape of objects.

  • PDF

Development of On-Line Partial Discharge Measuring System for Insulation Diagnosis of High-Voltage Motor Stator Windings (고압 전동기 고정자 권선의 절연진단을 위한 운전중 부분방전 측정 시스템 개발)

  • Hwang, Don-Ha;Kang, Dong-Sik;Shin, Byoung-Chol;Lee, Young-Jin;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.481-486
    • /
    • 2006
  • In this paper, a new on-line high-voltage motor monitoring system is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). And this system displays magnitude and phase angle distribution of PD. Sensor, CC (Ceramic Coupler) is used for PD measurement. PD signals are continuously measured and digitized with a A/D converter to build the database of the high-voltage motor's insulation condition. Also, this system can communicate with the central monitoring system via RS-232, 422, and TCP/IP. This helps more efficient operation and maintenance of the high-voltage motor.

  • PDF