• 제목/요약/키워드: High Line

검색결과 8,107건 처리시간 0.061초

Fast clip을 적용한 콘크리트궤도용 노스가동 분기기 개발 (Development of Movable nose crossing turnout on concrete track using Fast Clip)

  • 황광하;류기대;박춘복;박광련;윤병현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.287-296
    • /
    • 2011
  • Turnout is a mechanical installation enabling railway trains to be guided from one track to another at a railway junction. A movable nose crossing frog is a device used at a railway turnout to eliminate the gap at the common crossing (High manganese, block, assembly crossing)which can cause impact damage, noise and vibration. Our government has a plan speed up of conventional line to 250km/h semi-high speed. We had already developed flexible turnout with fixed crossing(High manganese) and SFC fastening system can cover in the semi-high speed line In this study is about development of the movable nose crossing turnout available Semi-high speed line on concrete track. This paper describes about geometry, attack angle, bending stress at the nose, switching force, safety of continuous welded long rails. This movable nose crossing turnout is expected greatly increases passing speed of turnout in national railway.

  • PDF

수직축 인-라인 고속 원심펌프용 종속기 개발에 관한 연구 (A Study on the Development of Increasing Gear Box for the High Speed Veritical In-Line Centrifugal Pump)

  • 김병옥;이동환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.393-398
    • /
    • 2002
  • In this study, the increasing gear boxes for the high speed vertical in-line centrifugal pump are developed through rotor dynamic analysis. The developed increasing gear boxes are two kinds for 18000rpm and 25000rpm at the output shaft. The gear sets suitable for high speed and high load are manufactured by investigating AGMA bending strength and AGMA surface strength severely. The rotor dynamic analysis on gear sets and bearings is performed in order to avoid the critical speeds and other troubles. As a result of study, the two increasing gear boxes for the high speed vertical in-line centrifugal pump are designed and manufactured.

  • PDF

경부고속철도 시험선 구간에서 G7 고속전철 차량의 동특성 검토 (Review on the Dynamic Behavior of G7 High Speed Train(KHST) in the KTX Test Line)

  • 박찬경;김영국;배대성;박태원
    • 한국철도학회논문집
    • /
    • 제4권4호
    • /
    • pp.131-137
    • /
    • 2001
  • The dynamic behavior of high speed train is very important because of its safety and passengers' ride comfort. The railway vehicle is composed of many suspension components, such as 1st springs, 1st dampers, 2nd springs and 2nd dampers, that have an influence on the dynamic characteristics of high speed train. Also, the wheel/rail shapes and the track geometry affect the dynamic behavior of high speed train. This paper reviews the dynamic behavior of KHST in the KTX test line. The VAMPIRE program is used for this simulation. The simulation results are within the limits of safety criteria. Thus the KHST can operate safely at 350 km/h in the KTX test line.

  • PDF

전자파 검출에 의한 전력기기 On-Line 열화 측정시스템 개발 (Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment)

  • 강창원;최길수;이영상;김창욱;강대수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1664-1666
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

광학 선형 패터네이터를 이용한 고압 환경 하에서의 분무 측정 (Spray Measurement Using Optical Line Patternator at High Ambient Pressure)

  • 고현석;신상희;윤영빈
    • 한국가시화정보학회지
    • /
    • 제3권1호
    • /
    • pp.63-70
    • /
    • 2005
  • Optical Line Patternator(OLP) has been applied to get a distribution of the spray at high ambient pressure. OLP is a combined technique of extinction measurement and image processing. The attenuated intensity of laser beam after traversing spray region was measured by using a photo-detector, and the line image of Mie-scattering was captured simultaneously in the path of each laser beam by using a CCD camera. The distribution of extinction coefficient in the spray is obtained by processing these data with the algebraic reconstruction technique. From the distribution of extinction coefficient, the surface distribution of spray can be reconstructed. OLP does not use laser sheet but use laser beam so that the noise effect of multiple scattering, caused by increasing number density of droplet in high pressure environment, is reduced drastically. OLP is expected as a suitable method which can investigate the characteristics of relatively large spray under the high pressure environment such as liquid rocket engine.

  • PDF

수직축 인-라인 고속 원심펌프용 증속기 개발에 관한 연구 (A Study on the Development of Increasing Gear Box for the High Speed Vertical In-Line Centrifugal Pump)

  • Kim Byung Ok;Lee Dong Hwan
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.343.1-343
    • /
    • 2002
  • In this study, the increasing gear boxes for the high speed vertical in-line centrifugal pump are developed through rotor dynamic analysis. The developed increasing gear boxes are two kinds fur 18000rpm and 25000rpm at the output shaft. The gear sets suitable for high speed and high load are manufactured by investigating AGMA bending strength and AGMA surface strength severely. The rotor dynamic analysis on gear sets and bearings is performed in order to avoid the critical speeds and other troubles. As a result of study, the two increasing gear boxes for the high speed vertical in-line centrifugal pump are designed and maunfactured.

  • PDF

경부선 고속열차 증속을 고려한 철도인프라 보강 방안 (Suggestion to Improve the Railway Infra for Speed Increase of High-speed Train in Gyeongbu Line)

  • 김정훈;박대근;원용환;김만철;강영종
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1249-1253
    • /
    • 2009
  • Enhancements of transport capacity in Gyeongbu line are continuous with the operating cost reduction and Korean economic development. Besides, requirements of a people about speed-up and customer service after the opening of high-speed railway(KTX) are being increased nowadays. Therefore, development and effort for speed increase of high-speed railway(KTX) have to be encouraged and supported by the government. In this study, market and technology trends for speed increase of high-speed train in Korea and abroad were investigated. As a result, we suggested to improve the railway infra for speed increase of high-speed train in Gyeongbu line.

  • PDF

고압 회전기 고정자 권선의 절연진단을 위한 중앙 집중 감시 시스템 개발 (Development of Central Monitoring System for Insulation Diagnosis of High-Voltage Generator/Motor Stator Windings)

  • 신병철;윤대회;황돈하;김용주;주영호;김정우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1906-1908
    • /
    • 2000
  • The central monitoring system with on-line diagnosis of high-voltage generator/motor stator insulation is developed. The system is capable of remote diagnosis and monitoring partial discharges of high-voltage generator/motor stator insulation. GOMS(Generator On-line Monitoring System) with maximum of 9 input channels can measure and analyze the status of high-voltage motor stator insulation by on-line. The measured and analysis data are brought to the central monitoring system via modem to build database. The central monitoring system can diagnose and monitor the insulation status of several high-voltage generator/motor at any time. The insulation status of those machines can be enhanced by the database on partial discharges.

  • PDF

Characteristics of Waesungri Maize (Zea mays L.) Inbred with Multi Tillers and Ears for Crude Forage Use

  • Lee, Hee-Bong
    • Plant Resources
    • /
    • 제4권1호
    • /
    • pp.31-35
    • /
    • 2001
  • Major characteristics of new Waesungri maize inbred line has multi-tiller and ears: five to six tillers and seven to eight ears per plant and flowering date of Waesungri was delayed about 18 and 24 days compared to Mo17 U.S line and IK$_4$ Korean local lines, respectively. Number of ears, fresh and dry weight per plant were significantly different among all tested hybrids including Waesungri/Sinkihong hybrid under different planting times and densities. Especially, both fresh and dry weight of IK$_1$/FR140//Waesungri F$_1$hybrid were significantly higher at high planting density. In kernel weight per unit area, Wnesungri/Sinkihong hybrid was high at high density and IK$_1$/FR140//Waesungri hybrid was high at low planting density. As results of analysis of variance, flowering date was shown a significantly different both planting times and varieties, while other characters including stem height were shown very variable in interactions with enviromental factors.

  • PDF

전원외란 시뮬레이터를 이용한 고속전철 이선현상 모의 실험 (The Simulation Implementation on contact loss of high speed electric railway using a Power Line Disturbance simulator)

  • 김재문;김양수;장진영;안정준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2152_2153
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

  • PDF