• 제목/요약/키워드: High Frequency

검색결과 18,923건 처리시간 0.049초

DFT 기반 페이저 연산 시 새로운 저역통과필터를 이용한 고주파 노이즈 경감 방법 (High Frequency Noise Reduction Method Using a Newly Designed Low-pass Filter in DFT-Based Phasor Estimation)

  • 백민우;강상희
    • 전기학회논문지
    • /
    • 제66권6호
    • /
    • pp.898-904
    • /
    • 2017
  • DFT(Discrete Fourier Transform) is one of the most widely used method to estimate the phasor of a relaying signal. The harmonics are eliminated by the DFT. However, high frequency components, except for harmonics, are not removed and cause an error in DFT-based phasor estimation process. This paper suggests high frequency noise reduction method by using a newly designed low-pass filter to estimate a signal phasor. When selecting a stop-band cut-off frequency of the low-pass filter, high frequency components generated by faults are considered. To reduce the phasor estimation delay caused by a low-pass filter, this paper proposes a low-pass filter whose settling time is reduced. An adverse effect of high frequency noise on DFT-based phasor estimation is reduced. To evaluate the performance of the proposed method, signals which are collected under a fault condition at a 345[kV] transmission system modeled by EMTP-RV are used.

Evaluation of MCC seismic response according to the frequency contents through the shake table test

  • Chang, Sung-Jin;Jeong, Young-Soo;Eem, Seung-Hyun;Choi, In-Kil;Park, Dong-Uk
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1345-1356
    • /
    • 2021
  • Damage to nuclear power plants causes human casualties and environmental disasters. There are electrical facilities that control safety-related devices in nuclear power plants, and seismic performance is required for them. The 2016 Gyeongju earthquake had many high-frequency components. Therefore, there is a high possibility that an earthquake involving many high frequency components will occur in South Korea. As such, it is necessary to examine the safety of nuclear power plants against an earthquake with many high-frequency components. In this study, the shaking table test of electrical facilities was conducted against the design earthquake for nuclear power plants with a large low-frequency components and an earthquake with a large high-frequency components. The response characteristics of the earthquake with a large high-frequency components were identified by deriving the amplification factors of the response through the shaking table test. In addition, safety of electrical facility against the two aforementioned types of earthquakes with different seismic characteristics was confirmed through limit-state seismic tests. The electrical facility that was performed to the shaking table test in this study was a motor control center (MCC).

해계(解谿)(ST41) 유침 및 전침의 전.후처치가 loperamide로 억제된 흰쥐의 장운동에 미치는 영향 (The Effect of Acupuncture and Electro-acupuncture at ST41 on Experimentally-induced Intestinal Hypo-motility in Rats: Comparison between Pre-treatment and Post-treatment)

  • 김경민;이현;임윤경
    • 대한한의학회지
    • /
    • 제33권3호
    • /
    • pp.20-32
    • /
    • 2012
  • Objectives: The purpose of this study was to investigate the effect of acupuncture and electro-acupuncture (EA) of low and high frequencies at Haegye (ST41) in rats. Methods: The intestinal motility of rats was experimentally suppressed with loperamide. Acupuncture, low frequency EA and high frequency EA were carried out before the loperamide administration in the pre-treatment group, and after the loperamide administration in the post-treatment group. The rats were fed charcoal and the travel rate of charcoal in the gastrointestinal track was measured to analyze the effect of acupuncture, low frequency EA and high frequency EA on the intestinal hypo-motility. Results: 1. None of acupuncture, low frequency EA or high frequency EA at ST41 showed significant influences on intestinal motility of rats in normal status. 2. Pre-treatment with acupuncture at ST41 showed no significant effect on the intestinal hypo-motility induced by loperamide in rats. 3. Pre-treatment with low frequency EA and high frequency EA at ST41 significantly reduced the suppression of intestinal motility by loperamide in rats. 4. Post-treatment of acupuncture, low frequency EA and high frequency EA at ST41 had no significant influences on the intestinal hypo-motility induced by loperamide in rats. Conclusions: These results suggest that low and high frequency EA at ST41 may be effective to prevent gastric disorders such as intestinal hypo-motility.

고압방전램프의 음향공명감소를 위한 주파수변조에 관한 연구 (A Study on Frequency-Modulated Methods for Reducing Acoustic Resonance in HID Lamp)

  • 김기중
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권12호
    • /
    • pp.622-626
    • /
    • 2001
  • HID(high intensity discharge)lamps are high pressure mercury lamp, high pressure sodium lamp and metalhalide lamp. metalhalide lamp among these lamps has considered to be one of the most effective artificial light sources and this lamp has good efficiency, good color rendition and good focusing capability, But the shortcorning of metalhalide lamp is known as acoustic resonance phenomena in the discharge tube when lighted by electronic ballast and then acoustic resonance cause various problems such as the arc instability, light output fluctuations. In this paper, to reduce the acoustic resonence phenomena, the electronic ballast was designed by three methods for high frequency operation wish frequency-modulated sinusodial waves in acoustic resonance frequency band. These frequency-modulated methods are resonance frequency and resonance frequency, resonance frequency and non-resonance frequency non-resonance frequency and non-resonance frequency Experiment results could't show the Presence of acoustic resonance visually and it proved that the resonance-generating conditions can be avoided by continuously changing the two operating frequencies in acoustic resonance band (20.59kHz∼94.2kHz).

  • PDF

체형분류 방법에 따른 체형 유형 간 비교 - 18~24세 여성을 대상으로 - (Comparison of somatotypes from various classification methods - Between 18 and 24 years old Korean Women -)

  • 이정임;남윤자
    • 한국의류산업학회지
    • /
    • 제6권2호
    • /
    • pp.221-228
    • /
    • 2004
  • The purpose of this study was to compare somatotypes from various classification methods, to analyze the interrelation among each somatotype or each high frequency type, and to suggest the basis to interpret body size and shape more accurately. As a sample, the subjects were 97 Korean females between 18 and 24 years old. They were measured both anthropometric and photographic measuring in November, 1999. Their somatotypes were classified by three kinds of classification methods. The first method was based on the lateral view of body, the second involved Factor and Cluster analysis with the photographic measurements of anterior and lateral body, and the third involved Factor and Cluster analysis with the anthropometric measurements of whole body. The upper body was classified into three types, and the lower body was classified into 6 types from the lateral view of body. The bend-forward/q-2 was found to be the 'High-frequency type from the lateral view of body', and the Straight/n-1 was found to be the 'Straight type from the lateral view of body'. From the classification by the analysis of photographic measurements, the anterior body was classified into three types, the lateral was classified into 4 types. The X/${\varepsilon}$ type was found to be the 'High-frequency type from the analysis of photographic measurements of anterior and lateral body'. From the classification by the analysis of anthropometric measurements, the whole body was classified into three types. The i type was found to be the 'High-frequency type from the analysis of anthropometric measurements of whole body'. The significant interrelation was certified among some somatotypes or some High-frequency types. We found that both the view of body and the statistical analysis would make the clear definition of each somatotype possible. In order to certify the representativeness of High-frequency type, further analysis would be required of subjects who were in the High-frequency type and their body parts were in the High-frequency range.

합곡(合谷)(LI4)의 고주파 온침 자극이 흰쥐의 족과(足踝) 관절염(關節炎)에 미치는 효과 (Effects of High Frequency Warm Needling of LI4 Acupoint on the Carrageenan-induced Arthritis in Rats)

  • 박상연;권오상;최원종;김재효;김경식;손인철;안성훈
    • Korean Journal of Acupuncture
    • /
    • 제26권2호
    • /
    • pp.61-74
    • /
    • 2009
  • Objectives: The warm needling technique is a method which combines the effects of acupuncture with those of moxibustion. The purpose of this study was to find the stimulus effects of a high frequency warm needling device when stimulating acupoint $LI_4$ on the carrageenan-induced arthritis. Methods: This study was to observe the effects to edema reaction, WBF(weight bearing force), NO concentration, nNOS expression after the electro high frequency stimulus of high frequency warm needling device on LI4 with insulated acupuncture needle. Results: The effect of the high frequency warm needling device is to rise up the temperature in proportion to the current intensity. After stimulating on the acupoint $LI_4$ of the carrageenan-induced arthritis in rats with the high frequency warm needling device, it significantly reduced edema in the rat's foot. In addition, WBF, NO concentration of spinal cord (nmol/mg), and nNOS relative expression were reduced. Conclusions: The above results support the idea that stimulus by the high frequency warm needling device on $LI_4$ produces a potent analgesic effect in the arthritis pain model of the rat. Moreover, stimulus by the high frequency warm needling device modulates endogenous NO through the suppression of nNOS protein expression.

  • PDF

권선 방식에 의한 공통 모드 초크의 특성해석에 관한 연구 (A Study on Characteristics Analysis of Winding Method for Common-Mode Choke)

  • 원재선;김희승;김종해
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.8-14
    • /
    • 2014
  • This paper presents the intra capacitance modeling according to the winding method and section bobbin for CM choke capable of the EMI attenuation of broad bands from lower frequency bands to higher frequency bands and high frequency type common-mode choke capable of the EMI attenuation of high frequency band used in the EMI Block of LED-TV SMPS. In case of high frequency type CM choke, it can be explained the parasitic capacitance of A type and section bobbin type winding methods among them is much smaller than the other. The first resonant frequency of the proposed CM choke tends to increase as the parasitic capacitance becomes small and its impedance characteristics also show improved performance as the first resonant frequency increases. In the future, the CM chokes of high frequency type show it can be practically used in not only LED/LCD-TV SMPS but also several applications such as LED Lighting, Adapter and so on.

HVC-고주파변압기 내장형 펄스전원장치를 이용한 Microwave Oven의 효율 향상 (Efficiency Improvement of Microwave Oven Using a Pulse Power Supply Embedded HVC-High Frequency Transformer)

  • 정병환;조준석;강병희;목형수;최규하
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권3호
    • /
    • pp.180-187
    • /
    • 2004
  • A conventional power supply of a microwave oven has a 60Hz transformer and high voltage capacitor(HVC). Though it is very simple and has low cost, it has several problems such as large size, heavy weight and low efficiency To improve these problems, various high frequency inverter type power supply have been investigated and developed in recent years. But these cost is higher than the conventional one due to additional control circuit, fast switching devces. In this paper, a novel pulse power supply for microwave oven using high frequency transformer embedded HVC(High Voltage Capacitor) is proposed for down-sizing, cost reduction and efficient improvement. To verify the effectiveness of the proposed transformer, an equivalent circuit of transformer embedded HVC is derived and it's characteristic is described. And the validity of the proposed pulse power supply embedded HVC-high frequency transformer is shown by simulations and experiments accroding to various operating conditions.

차체 구조 차이에 따른 충돌 고주파 신호 전달성 연구 (A Study on the Signal Transmissibility of High Frequency Crash Pulse according to the Car Structure Difference)

  • 박동규
    • 한국자동차공학회논문집
    • /
    • 제21권6호
    • /
    • pp.8-15
    • /
    • 2013
  • Wide range frequency pulses occur in a car crash test. Until now, low frequency under 400Hz has been used to determine an airbag deployment criteria. Also, FIS (Front Impact Sensor) has been used to detect the crash pulse in early stage. Nowadays, technology to determine an airbag delpoyment criteria by using a high frequency crash pulse without FIS is being focused on. In this paper, the signal transmissibility of high frequency pulse for two different cars was studied. Also, signal transfer test of high frequency pulse was done by using a high speed ball impact. Signal runtime of the frontal impact is compared with that of the side impact. The signal transmissibility difference due to the car structure difference was discussed and structure change for improving the signal transmissibility was proposed.

SMPS용 고주파 트랜스의 고장의 분석 및 재현시험법에 관한 연구 (A Study on the Failure Analysis and Representation Test Method of High Frequency Transformer for SMPS)

  • 임홍우;이영주;한지훈
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.766-770
    • /
    • 2011
  • In this paper, we describe the failure analysis and representation test method that applied high frequency transformer for SMPS through analysing insulation resistance, frequency characteristic, CT analysis, Q-factor atc. And we study the judgement method that a high frequency transformer affects to other beside parts in different condition or environment. According to this method, we devise a plan for the field failure prevent and propose the securing product reliability of high frequency transformer.