• Title/Summary/Keyword: High Dose Rate

Search Result 884, Processing Time 0.027 seconds

Results of Stereotactic Radiosurgerv with Linear Accelerator for Intracranial Arteriovenous Malformation (두개강내 동정맥기형에서 선형가속기를 이용한 방사선수술의 결과)

  • Lee Kang Kyoo;Park Kyung Ran;Lee Jong Young;Lee Yong Ha
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.215-224
    • /
    • 1997
  • Purpose : Stereotactic radiosurgery with external beam irradiation successfully obliterates carefully selected intracranial arteriovenous malformation (AVM) . We Present clinical and radiological long term results after treatment with a single high dose irradiation using a linear accelerator. Materials and Methods : Rrom January 1991 to June 1994, fifteen patients with intracranial AVM were treated in our hospital with the stereotactic radiosurgery using a linear accelerator. The radiation was delivered using a 6 MV linear accelerator. The prescribed doses at the isocenter varied from 1800 to 2500cGy (median : 2000cGy) and were given as a sin91e fraction. The radiation doses at the periphery of the lesion typically corresponded to the 80-90% isodose line. In 14 patients, complete clinical and/or radiological follow-up examination were available. Results : Angiography was available in 13 patients with a follow-up Period from 18 months to 27 months. Of 13 patients, the overall complete obliteration rate was 92.3% (12 patients). This incidence did not correlate with lesion size. Seizure, headache and progressive neurologic deficit were complete recovered. One Patient experienced hemorrhage at 2 months after treatment. One patient developed radiation induced brain edema in the white matter surrounding nidus at 16 months after treatment and showed complete resolution of the edema in MR image obtained at 27 months after treatment. After a follow-up period of up to 6 years, no radiation induced severe late complications occurred. Conclusion : We conclude that stereotactic radiosurgery using a linear accelerator is an effective and safe therapy for symptomatic and surgically inaccessible intracranial AVMs and the results compare favorably to the more expensive and elaborate systems that are currently available for stereotactic radiosurgery.

  • PDF

Diagnosis and Post-Therapeutic Evaluation of Arteriovenous Malformations in Extremities Using Transarterial Lung Perfusion Scintigraphy (경동맥 폐관류 신티그라피를 이용한 상하지 동정맥 혈관기형의 진단과 치료 평가)

  • Chung, Hyun-Woo;Choi, Joon-Young;Kim, Young-Wook;Kim, Dong-Ik;Do, Young-Soo;Lee, Eun-Jeong;Lee, Su-Jin;Cho, Young-Seok;Hyun, Seung-Hyup;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.316-321
    • /
    • 2006
  • Purpose: Differential diagnosis between arteriovenous (AVMs) aud non-arteriovenous malformations (nAVMs) is important in patients with congenital vascular malformations, because AVMs can cause hemodynamic alteration and require immediate treatment. We investigated whether transarterial lung perfusion scintigraphy (TLPS) was useful for the diagnosis and post-therapeutic evaluation of AVMs in extremities. Materials and Methods: Fifty-seven patients (M:F=26:31, $21{\pm}13$ yr, 9 upper and 48 lower extremities) suspected of congenital vascular malformations in extremities underwent TLPS using $^{99m}Tc-MAA$ before embolization/sclerotherapy. Dose-corrected shunt fraction (SF) was calculated from time-activity curve of the lung. Final diagnosis of AVMs was determined by angiography. in patients with AVMs, follow-up TLPS was done for post-therapeutic evaluation. Results: Sixteen patients (8 upper and 8 lower extremities) had AVMs, while the remaining 41 had nAVMs (1 upper and 40 lower extremities). The mean SF of AVMs on TLPS was significantly higher than that of nAVMs ($66.4{\pm}25.8%\;vs.\;2.8{\pm}4.3%$), p=0.003). The sensitivity, specificity, and accuracy of TLPS (cut-off of SF = 20.0%) in diagnosis of AVMs before treatment were 93.8% (15/16), 100% (41/41) and 98.2% (56/57), respectively. The follow-up TLPS and angiography for post-therapeutic evaluation showed concordant results in 13 of 16 patients (81.3%) with AVMs. The mean SF of TLPS was significantly decreased after embolization/sclerotherapy ($69.5{\pm}24.0%\;vs.\;41.0{\pm}34.7%$, p=0.01). Conclusion: TLPS provides hemodynamic information of AVMs in extremities semiquantitatively. Furthermore, the results of TLPS showed a high concordance rate with angiographic findings. Therefore, TLPS is useful for the diagnosis and post-therapeutic evaluation of AVMs in extremities.

Water Treatment Application of a Large Pore Micro-Filtration Membrane and Its Problems (대기공 정밀여과막의 수처리 응용 및 문제점)

  • Yun, Chang-Han;Kim, Jeong-Hak;Lee, Kang Won;Park, Sung Ho
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.194-200
    • /
    • 2014
  • The purpose of this study was to evaluate the performance of newly developed Large Pore Micro-Filtration (LPMF) membrane in Lab size for the application of water treatment, and to find its problems with solutions. The out-to-inside filtration hollow fiber LPMF membrane of which average pore size was $5{\mu}m$ was used at this study and its material was the PET braid reinforced PVDF. Filtration tests were done through gravity with 30 cm water head difference or pressure below 1.5 bar, and the backwash was done instantaneously with the filtrate after pressurizing it to about 4 bar. The water flux of the LPMF membrane with 0.2 bar TMP (Trans Membrane Pressure) was 2 times higher than $0.4{\mu}m$ MF membrane with $0.05{\mu}m$ UF filtrate of the tap water and it was measured also with 20~30 cm water head difference which showed over 800 LMH at 30 cm water head difference. And Time-To-Filter (TTF) was performed by using $5{\mu}m$ filter paper to optimize coagulants and dosage which enhanced filtrate's turbidity and stabilized filtration flux. When the LPMF was operated with 30 cm gravity with very high dose of inorganic coagulants, the flux was maintained over 80 LMH with 93.5~99.5% turbidity removal. Especially, the filtration was maintained stably in the flux and about 97% of the recovery rate by instantaneous pressurized backwash with about 4 bar of the filtrate when the packing density was about 19%. But there was instability in filtration, since the TMP was continuously going up by inefficient backwash when the packing density was 43%.

Short-term Results of Endobronchial Brachytherapy for Malignant Airway Obstructions (악성 기도 폐쇄에 대한 기관내 근접 조사 방사선치료의 단기 임상 경험)

  • Ahn Yong Chan;Lim Do Hoon;Choi Dong Rak;Kim Moon Kyung;Kim Dae Yong;Huh Seung Jae;Kim Ho Joong;Chung Man Pyo;Kwon O Jung;Rhee Chong Heon
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.299-306
    • /
    • 1996
  • Purpose : Respiratory symptoms related with malignant airway disease have been the main causes of lowered qualify of life and also sometimes may be life-threatening if not properly managed. The authors report the short-term experiences of endobronchial brachytherapy for symptomatic malignant airway obstruction using high dose rate after-loading brachytherapy unit. Materials and Methdos : Twenty-five Patients with symptomatic malignant airway obstruction were treated with endobronchial brachytherapy between the period of December 1994 and March 1996 at Department of Radiation Oncology of Samsung Medical Center Twenty-one ($84\%$) were patients with non-small cell lung cancer, three with tracheal malignancies, and one with recurrence of esophageal cancer. Twenty Patients were given elective external beam radiation therapy, while six were given endobronchial laser evaporation therapy on emergency bases in addition to endobronchial brachytherapy. Three procedures for each patient were planned and total of 70 procedures were completed. Results : Improvement rates of major respiratory symptoms after endobronchial brachytherapy procedures were $88\%$(22/25). $96\%$(22/23), $100\%$ (15/15), and $100\%$(9/9) for cough, dyspnea, hemoptysis and obstructive pneumonia, respectively. ECOG performance scores were improved in $56\%$ of total patients group, while there was no case with worsened ECOG score. Fifteen patients died and the median interval from the start of treatment to death was 4 months (range: $1\~17$ months), while that of ten survivors was 9 months (range $5\~19$ months). There were five patients with controlled intrathoracic disease, who have survived over one rear. All deaths were associated with uncontrolled local and/or distant disease. Four Patients died of massive fatal hemoptysis, three of who received emergency endobronchial laser evaporation therapy before the start of endobronchial brachytherapy. Conclusion : Endobronchial brachytherapy has been confirmed as an excellent palliative treatment modality improving respiratory symptoms as well as patients' general performance status. Based on the current observations, use of endobronchial brachytherapy in curative setting as a boost technique may be warranted.

  • PDF

Evaluation of Toxicological Data on Food Additives and Guideline for ADI establishment - Polydimethylsiloxane as emulsifier - (식품첨가물의 독성자료 고찰과 ADI 평가지침 - 소포제 Polydimethylsiloxane를 사례로 -)

  • Choi, Chan-Woong;Jeong, Ji-Yoon;Park, Hyoung-Su;Moon, Jin-Hyun;Lee, Kwang-Ho;Lee, Hyo-Min
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.4
    • /
    • pp.352-356
    • /
    • 2009
  • The purpose of this study was to introduce the toxicological study review to evaluate the safety of PDMS on the 69th JECFA meeting. Polydimethylsiloxane is a polymer and its ADI was established at 23rd JECFA meeting in 1979. The ADI was maintained although the specification was expanded at its 26th, 29 th, 37 th meetings. Recently, it was reported that PDMS with low molecular weight and viscosity has high absorption rate and different toxicity, so it was submitted at 69th meeting. Toxicological studies of PDMS were submitted from the sponsor and additional information is collected from a document searching. The toxicological studies were reviewed in accordance with the 'Guidelines for the preparation of toxicological working papers for the Joint FAO/WHO Expert Committee on Food Additives'. In the available acute, sub-chronic and chronic toxicity studies on PDMS, dose-related increases in incidence and severity of ocular lesions(corneal crystal, inflammation of the corneal epithelium etc.) were consistently observed after oral dosing. It seems to be a local irritant effect, but the mechanism by which the ocular lesions arose is unclear, although the lack of absorption of PDMS indicates that it is unlikely to be a direct systemic effect. Consequently, the relevance of the ocular lesions for food use of PDMS could not be determined. The ADI of PDMS was re-established from 0-1.5 mg/kg bw/day to 0-0.8 mg/kg bw/day by applying additional safety factor 2 based on its ocular toxicity. The result of 0-0.8 mg/kg bw/day is a temporary ADI until further data are provided to 2010.

Activation Analysis of Dual-purpose Metal Cask After the End of Design Lifetime for Decommission (설계수명 이후 해체를 위한 금속 겸용용기의 방사화 특성 평가)

  • Kim, Tae-Man;Ku, Ji-Young;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.343-356
    • /
    • 2016
  • The Korea Radioactive Waste Agency (KORAD) has developed a dual-purpose metal cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. The metal cask was designed in compliance with international and domestic technology standards, and safety was the most important consideration in developing the design. It was designed to maintain its integrity for 50 years in terms of major safety factors. The metal cask ensures the minimization of waste generated by maintenance activities during the storage period as well as the safe management of the waste. An activation evaluation of the main body, which includes internal and external components of metal casks whose design lifetime has expired, provides quantitative data on their radioactive inventory. The radioactive inventory of the main body and the components of the metal cask were calculated by applying the MCNP5 ORIGEN-2 evaluation system and by considering each component's chemical composition, neutron flux distribution, and reaction rate, as well as the duration of neutron irradiation during the storage period. The evaluation results revealed that 10 years after the end of the cask's design life, $^{60}Co$ had greater radioactivity than other nuclides among the metal materials. In the case of the neutron shield, nuclides that emit high-energy gamma rays such as $^{28}Al$ and $^{24}Na$ had greater radioactivity immediately after the design lifetime. However, their radioactivity level became negligible after six months due to their short half-life. The surface exposure dose rates of the canister and the main body of the metal cask from which the spent nuclear fuel had been removed with expiration of the design lifetime were determined to be at very low levels, and the radiation exposure doses to which radiation workers were subjected during the decommissioning process appeared to be at insignificant levels. The evaluations of this study strongly suggest that the nuclide inventory of a spent nuclear fuel metal cask can be utilized as basic data when decommissioning of a metal cask is planned, for example, for the development of a decommissioning plan, the determination of a decommissioning method, the estimation of radiation exposure to workers engaged in decommissioning operations, the management/reuse of radioactive wastes, etc.

Presence of Leukemia-maintaining Cells in Differentiation-resistant Fraction of K562 Chronic Myelogenous Leukemia (만성 골수성 백혈병 K562세포의 분화 내성 분획에서 백혈병 유지 세포의 동정)

  • Lee, Hong-Rae;Kim, Mi-Ju;Ha, Gahee;Kim, So-Jung;Kim, Sun-Hee;Kang, Chi-Dug
    • Journal of Life Science
    • /
    • v.23 no.2
    • /
    • pp.197-206
    • /
    • 2013
  • The present study investigated whether leukemia-maintaining cells reside in a differentiation-resistant fraction using a megakaryocytic differentiation model of K562 cells. Treatment with phorbol-12-myristate-13-acetate (PMA) significantly inhibited the colony-forming efficiency of the K562 cells. At a PMA concentration of 1 nM or higher, colony was not formed, but approximately 40% of K562 cells still survived in soft agar. Approximately 70% of colony-forming cells that were isolated following the removal of PMA after exposure to the agent were differentiated after treatment with 10 nM PMA for 3 days. The differentiation rate of the colony-forming cells was gradually increased and reached about 90% 6 weeks after colony isolation, which was comparable to the level of a PMA-treated K562 control. Meanwhile, imatinib-resistant variants from the K562 cells, including K562/R1, K562/R2, and K562/R3 cells, did not show any colony-forming activity, and most imatinib-resistant variants were CD44 positive. After 4 months of culture in drug-free medium, the surface level of CD44 was decreased in comparison with primary imatinib-resistant variants, and a few colonies were formed from K562/R3 cells. In these cells, Bcr-Abl, which was lost in the imatinib-resistant variants, was re-expressed, and the original phenotypes of the K562 cells were partially recovered. These results suggest that leukemia-maintaining cells might reside in a differentiation-resistant population. Differentiation therapy to eliminate leukemia-maintaining cells could be a successful treatment for leukemia if the leukemia-maintaining cells were exposed to a differentiation inducer for a long time and at a high dose.

Ultrasound-Guided Axillary Brachial Plexus Block, Performed by Orthopedic Surgeons (정형외과 의사가 시행한 초음파 유도 액와 상완 신경총 차단술)

  • Kim, Cheol-U;Lee, Chul-Hyung;Yoon, Ja-Yeong;Rhee, Seung-Koo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.513-521
    • /
    • 2018
  • Purpose: The purpose of this study was to assess the effectiveness and complications of an ultrasound-guided axillary brachial plexus block performed by orthopedic surgeons. Materials and Methods: From March to May 2017, an ultrasound-guided axillary brachial plexus block was performed on a total of 103 cases of surgery. A VF13-5 transducer from Siemens Acuson X300 was used. The surgical site was included in the range of the anatomic sensory distribution of the blocked nerve, except for the case where an operation time of more than 2 hours was expected due to multiple injuries and the operation of the upper arm. The procedure was performed by 2 orthopedic surgeons in the same method using 50 ml of solution (20 ml of lidocaine HCl in 2%, 20 ml of ropivacaine in 0.75%, 10 ml of normal saline in 0.9%). The success rate of anesthesia induction during surgery, anesthetic induction time, anatomical range of operation, duration of postoperative analgesia and complications were investigated. Results: The results from the 2 practices were similar. The anesthesia was successful in 100 out of 103 patients (97.1%). In these patients, the average needling time was 5.5 minutes (2.5-13.2 minutes), the average induction time to complete anesthesia was 18.4 minutes (5-40 minutes), and the average duration of postoperative analgesia was 402.8 minutes (141-540 minutes). The post-anesthesia immediate complications were dizziness in 1 case, nausea and vomiting in 4 cases, and peri-oral numbness in 2 cases, but surgery was performed without problems. All these 7 cases with complications recovered on the same day. A total of 3 cases failed with anesthesia, and they were treated by an injection with local anesthesia in the operation room in 2 cases and switched to general anesthesia in 1 case. Conclusion: An ultrasound-guided axillary brachial plexus block, which was performed by orthopedic surgeons allows anesthesia in a brief period and the high success rates of anesthesia for certain surgeries of the elbow and surgeries on forearm, wrist and hand. Therefore, it can reduce the waiting time to the operating room. This technique is a relatively safe procedure and dose selective anesthesia is possible.

Application of Environmental Friendly Bio-adsorbent based on a Plant Root for Copper Recovery Compared to the Synthetic Resin (구리 회수를 위한 식물뿌리 기반 친환경 바이오 흡착제의 적용 - 합성수지와의 비교)

  • Bawkar, Shilpa K.;Jha, Manis K.;Choubey, Pankaj K.;Parween, Rukshana;Panda, Rekha;Singh, Pramod K.;Lee, Jae-chun
    • Resources Recycling
    • /
    • v.31 no.4
    • /
    • pp.56-65
    • /
    • 2022
  • Copper is one of the non-ferrous metals used in the electrical/electronic manufacturing industries due to its superior properties particularly the high conductivity and less resistivity. The effluent generated from the surface finishing process of these industries contains higher copper content which gets discharged in to water bodies directly or indirectly. This causes severe environmental pollution and also results in loss of an important valuable metal. To overcome this issue, continuous R & D activities are going on across the globe in adsorption area with the purpose of finding an efficient, low cost and ecofriendly adsorbent. In view of the above, present investigation was made to compare the performance of a plant root (Datura root powder) as a bio-adsorbent to that of the synthetic one (Tulsion T-42) for copper adsorption from such effluent. Experiments were carried out in batch studies to optimize parameters such as adsorbent dose, contact time, pH, feed concentration, etc. Results of the batch experiments indicate that 0.2 g of Datura root powder and 0.1 g of Tulsion T-42 showed 95% copper adsorption from an initial feed/solution of 100 ppm Cu at pH 4 in contact time of 15 and 30 min, respectively. Adsorption data for both the adsorbents were fitted well to the Freundlich isotherm. Experimental results were also validated with the kinetic model, which showed that the adsorption of copper followed pseudo-second order rate expression for the both adsorbents. Overall result demonstrates that the bio-adsorbent tested has a potential applicability for metal recovery from the waste solutions/effluents of metal finishing units. In view of the requirements of commercial viability and minimal environmental damage there from, Datura root powder being an effective material for metal uptake, may prove to be a feasible adsorbent for copper recovery after the necessary scale-up studies.

Effects for Growth and Chlorophyll in Old-barley and New-barley Seed exposed by X-ray (X-선이 묵은보리 씨앗과 햇보리 씨앗의 생장과 클로로필 농도에 미치는 영향)

  • Sang-Bok, Jeong;Sun-Cheol, Jeong;Mo-Kwon, Lee;Yun-Ho, Choi;Kang-Un, Byun;Su-Ah, Yu;Sang-Eun, Han;Jun-Beom, Heo;Wan-Sik, Shin;Won-Jeong, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.149-156
    • /
    • 2023
  • The purpose of this study is to compare of growth and chlorophyl between old-barley seed (OBS, 2019) and New-barley seed (NBS, 2020) exposed by X-ray. After germination the OBS and NBS, experimental group was exposed by 30 Gy X-ray using linear accelerator (Clinac IS, VERIAN, USA), by 6 MV X-ray, SSD 100 cm, 18 × 10 cm2, 600 MU/min. Length was measured every day until 9th day, and chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) after measuring weight in 9th day. Data analysis was performed the Independent T-test using SPSS ver 26.0(Chicago, IL, USA). NBS grow more faster than OBS in control group, but OBS grow more faster than NBS in experimental group. Length of control group was longer significantly every day than that of experimental group in OBS. NBS weighted more than OBS in control group, but OBS weighted more than NBS in experimental group. In comparing chlorophyl density, NBS high more than OBS in control group as well as experimental group. Growth and weight of OBS was effected more those than NBS by X-ray, but NBS in chlorophyl by X-ray. It is expected to be used as basic data for future X-ray research in barley seed.