• Title/Summary/Keyword: High Dose Rate

Search Result 878, Processing Time 0.023 seconds

Quantitative and Qualitative Extrapolation of Carcinogenesis Between Species

  • Gold Lois Swirsky;Manley Neela B.;Ames Bruce N.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02a
    • /
    • pp.431-438
    • /
    • 1994
  • As currently conducted, standard rodent bioassays do not provide sufficient information to assess carcinogenic risk to humans at doses thousands of times below the maximum tolerated dose. Recent analyses indicate that measures of carcinogenic potency from these tests are restricted to a narrow range about the maximum tolerated dose and that information on shape of the dose-response is limited in experiments with only two doses and a control. Extrapolation from high to low doses should be based on an understanding of the mechanisms of carcinogenesis. We have postulated that administration of the maximum tolerated dose can increase mitogenesis which, in turn. increases rates of mutagenesis and, thus, carcinogenesis. The animal data are consistent with this mechanism, because about half of all chemicals tested are indeed rodent carcinogens, and about 40% of the positives are not detectably mutagenic. Thus, at low doses where cell killing does not occur, the hazards to humans of rodent carcinogens may be much lower than commonly assumed. In contrast, for high-dose exposures in the workplace, assessment of hazard requires comparatively little extrapolation. Nevertheless. permitted workplace exposures are sometimes close to the tumorigenic dose-rate in animal tests. Regulatory policy to prevent human cancer has primarily addressed synthetic chemicals, yet similar proportions of natural chemicals and synthetic chemicals test positive in rodent studies as expected from an understanding of toxicological defenses, and the vast proportion of human exposures are to natural chemicals. Thus, human exposures to rodent carcinogens are common. The natural chemicals are the control to evaluate regulatory strategies, and the possible hazards from synthetic chemicals should be compared to the possible hazards from natural chemicals. Qualitative extrapolation of the carcinogenic response between species has been investigated by comparing two closely related species: rats and mice. Overall predictive values provide moderate confidence in interspecies extrapolation; however, knowing that a chemical is positive at any site in one species gives only about a 50% chance that it will be positive at the same site in the other species.

  • PDF

Hormesis as a Confounding Factor in Epidemiological Studies of Radiation Carcinogenesis

  • Sanders Charles L.
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.2
    • /
    • pp.69-89
    • /
    • 2006
  • Biological mechanisms for ionizing radiation effects are different at low doses than at high doses. Radiation hormesis involves low-dose-induced protection and high-dose-induced harm. The protective component is associated with a reduction in the incidence of cancer below the spontaneous frequency, brought about by activation of defensive and repair processes. The Linear No-Threshold (LNT) hypothesis advocated by the International Commission on Radiological Protection (ICRP) and the Biological Effects of ionizing Radiation (BEIR) Report VII for cancer risk estimations Ignores hormesis and the presence of a threshold. Cancer incidences significantly less than expected have been found in a large number of epidemiological studies including, airline flight personnel, inhabitants of high radiation backgrounds, shipyard workers, nuclear site workers in scores of locations throughout the world, nuclear power utility workers, plutonium workers, military nuclear test site Participants, Japanese A-bomb survivors, residents contaminated by major nuclear accidents, residents of Taiwan living in $^{60}Co$ contaminated buildings, fluoroscopy and mammography patients, radium dial painters, and those exposed to indoor radon. Significantly increased cancer was not found at doses <200 $mSv^*$. Evidence for radiation hormesis was seen in both sexes for acute or chronic exposures, low or high LET radiations, external whole- or partial body exposures, and for internal radionuclides. The ubiquitous nature of the Healthy Worker Effect (HWE)-like responses in cellular, animal and epidemiological studies negates the HWE as an explanation for radiation hormesis. The LNT hypothesis is wrong and does not represent the true nature of the dose-response relationship, since low doses or dose-rates commonly result in thresholds and reduce cancer incidences below the spontaneous rate. Radiation protection organizations should seriously consider the cost and health implications of radiation hormesis.

Epidemiological Investigation of a Measles Outbreak in a Preschool in Incheon, Korea, 2006 (2006년 인천의 한 유치원에서 발생한 홍역 유행 역학조사)

  • So, Jae-Sung;Go, Un-Yeong;Lee, Dong-Han;Park, Koang-Suk;Lee, Jong-Koo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.41 no.3
    • /
    • pp.153-158
    • /
    • 2008
  • Objectives : This study describes a plan that was designed to prevent a measles outbreak that showed a changed outbreak pattern. This study is based on the epidemiological investigation of a measles outbreak in a preschool in Incheon, Korea, 2006. Methods : The subjects were 152 students at a preschool where a measles outbreak occurred. A questionnaire survey was conducted and serological testing for measles-specific IgM was preformed. Results : Of the fifteen confirmed, identified cases, eleven patients had been vaccinated with one dose, one patient had received two doses and three patients were unvaccinated. The three unvaccinated cases consisted of one 5-year-old child, one 3-year-old child and one 16-month-old infant. For the cases with one dose of the vaccination, there were 11 cases, which consisted of six 5-year-old children, two 4-year-old children, two 3-year-old children and one 2-year-old child. The case with two doses of the vaccination was one 4-year-old child. The attack rate of measles was 100% in the 0-dose group, 11.2% in the 1-dose group and 2.0% in the 2-dose group. The vaccine's efficacy was 88.8% in the 1-dose group and 98.0% in the 2-dose group. The vaccine effectiveness for the 2-dose group was higher than that of the 1-dose group. Conclusions : High coverage with a 2-dose vaccination should be maintained, and the vaccination should be given at the suitable time to prevent a measles outbreak with a changed outbreak pattern.

Important Radionuclides and Their Sensitivity for Ground water Pathway of a Hypothetical Near-Surface Disposal Facility

  • Park, J. W.;K. Chang;Kim, C. L.
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.156-165
    • /
    • 2001
  • A radiological safety assessment was performed for a hypothetical near-surface radioactive waste repository as a simple screening calculation to identify important nuclides and to provide insights on the data needs for a successful demonstration of compliance. Individual effective doses were calculated for a conservative ground water pathway scenario considering well drilling near the site boundary. Sensitivity of resulting ingestion dose to input parameter values was also analyzed using Monte Carlo sampling. Considering peak dose rate and assessment time scale, C-14 and T-129 were identified as important nuclides and U-235 and U-238 as potentially important nuclides. For C-14, the dose was most sensitive to Darcy velocity in aquifer The distribution coefficient showed high degree of sensitivity for I-129 release.

  • PDF

Saccharomyces cerevisiae의 물질대사에 미치는 중성자의 영향

  • 이민재
    • Journal of Plant Biology
    • /
    • v.7 no.4
    • /
    • pp.9-14
    • /
    • 1964
  • According to the results measured the respiratory quotient of Saccharomyces cerevisiae with neutron radiation by manometric direct method, the respiratory quotient of them was stimulated at the dose(7$\times$106N/$\textrm{cm}^2$/sec) of neutron radiation for 60 seconds, and was inhibited in each group irradiated at the high dose (7$\times$108N/$\textrm{cm}^2$/sec) of neutron. Its physiological effects influenced on neutron had relations with respiratory quotient, reproductive rate and fermentation in the curve of normal logarithmic phase. The multiple reactions which appeared in yeast, indicated that a great deal of physiological function were closely correlated with the irradiated dosage of neutron. The kinds of free amino acid in yeast irradiated with neutron were different from those of unirradiated yeast. The activityof dehydrogenase system accelerated the metabolic function of yeast irradiated at some low dose of neutron. By this results, it may demonstrate that the fact which the phenomena obtained in the stimulation of neutron possess its character for several generation, is dependent on the theory of mutation. Subsequently, it seemed reasonable certain dominant type of microorganisms.

  • PDF

Antihypertensive Action of Clonidine Patch (Clonidine Patch제의 효능시험 : 혈압강하작용)

  • 정재훈;신찬영;류재련;박우일;고광호
    • Biomolecules & Therapeutics
    • /
    • v.4 no.2
    • /
    • pp.205-207
    • /
    • 1996
  • Clonidine, an antihypertensive drug, stimulates postsynaptic alpha-2 adrenergic receptors in the central nervous system and lowers arterial pressure through the effects on both cardiac output and peripheral resistance. However, many patients experience that sedation and xerostomia occur upon oral administration of clonidine. These side effects are due to high plasma peak concentration and can be avoided when clonidine is given transdermally. In this study, we tested the antihypertensive effects of trandermal administration of clonidine patch on spontaneously hypertensive rat (SHR) which is a model animal for human essential hypertension. Forty eight SHR (male) were divided into six groups according to the dose levels, respectively. After transdermal administration of clonidine patch of each dose, systolic blood pressure and heart rate were measured. Clonidine patch produced maximal antihypertensive and bradycardiac effects 48 hrs after administration and antihypertensive effects showed dose-dependency. We suggest that antihypertensive effects of clonidine patch are similar to those of orally given clonidine and clonidine patch can be used instead of clonidine tablet.

  • PDF

The Clinical Usefulness Evaluation of Normal Saline Injection in Coronary Artery Computed Tomography Angiography(Coronary CTA) (관상동맥 전산화단층촬영 조영검사에서 생리식염수 투여를 통한 임상 유용성 평가)

  • Jung, Kang-Kyo;Lee, Mi-Hwa;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.307-313
    • /
    • 2014
  • The purpose of this study is that in coronary artery angiography computed tomography (coronary CTA), to gain high quality of image and to use low dose radiation by administrating normal saline and converting the mode of scanning heart rate (HR) characteristics before infusing contrast media. All patients data (total specimens: 200, male: 108, female: 92) were measured by using appropriate mode of scanning the heart rate (HR) after injection of saline. in addition we measured radiation dose (CTDIvol, effective dose) in all examinations. CT number and noise, and blurring of coronary artery (proximal RCA, middle RCA, proximal LCA) were measured and compared. The result of this study after injection of saline, mean heart rate was decreased about $4.8{\pm}0.3bpm$ (beats per minute). 33 patients (13%) got converting scan mode due to reducing heart rate (HR). In prospective gating mode, radiation dose were measured less $6.0{\pm}1.0mSv$ (54.1%) than retrospective gating mode. Also showed a significant difference in heart rate decrease in image evaluation.

Reduced Effect of kV-CBCT Dose by Use of Shielding Materials in Radiation Therapy (방사선 치료 시 차폐물질 사용에 따른 kV-CBCT 선량감소 효과)

  • Jo, Hyeonjong;Park, Euntae;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.467-474
    • /
    • 2018
  • CBCT is useful for improving the accuracy of the treatment site, but Repeated use increases the exposure dose. In this study, we aimed to provide basic data for dose reduction in CBCT implementation by dataization the simulating and dose reduction effect using shielding substance. Material in this study, Analyzation the photon beam by simulate the CBCT Through MCNPX and then calculate the absorption dose of body organ at shooting moment of thoracic abdominal position as target UF-Revise simulated body. At this time. Dose reduction effects at this time were evaluated according to the texture of materials and presence of shielding materials( lead, antimony, barium, sulfate, tungsten, bismuth). When CBCT was taken without shielding, the dose was calculated to be high in the breast and spine, and the dose in the esophagus and lung was calculated to be low. The doses according to the shield material were calculated as barium sulfate, antimony, bismuth, lead, and tungsten. The shielding rate was the highest in the thymus (73.6%) and the breast (59.9%) compared with the dose reduction according to presence or absence of the shield. However, it showed the lowest shielding rate in lung (2.1%) and spine (12.6%).

Studies on the Cardiovascular Effects of Ambrein Pretreatment in Rats

  • Raza, M.;Taha, S.A.;El-Khawad, I.E.
    • Natural Product Sciences
    • /
    • v.5 no.1
    • /
    • pp.25-32
    • /
    • 1999
  • The pharmacological actions of ambrein were investigated alone or in combination as a pretreatment with agonists (adrenaline, noradrenaline, acetylcholine, histamine, nicotine), antagonists (atropine, atenolol) and calcium channel blocker (verapamil) in vivo in anaesthetized SWR rats using blood pressure, heart rate and myocardial contractility as parameters. Ambrein in the dose range of 50-200 mg/kg to the normotensive anaesthetized rats demonstrated negative chronotropic effect and increased the myocardial contractility significantly. At the mid dose (100 mg/kg) this increase in contractile force was 36% and 44% above the normal at 30 min and 60 min intervals post-treatment, respectively. Both of the lower and high doses (50 mg/kg and 200 mg/kg) had similar effects. Furthermore, this contractile response was dose related. Also, this compound produced a considerable increase in myocardial contractility when used as a pretreatment with some agonists and antagonists. The results on blood pressure did not show a considerable change when ambrein was used alone. However, ambrein pretreatment at the dose of 100 mg/kg did not block the effects of adrenaline, noradrenaline, isoprenaline and acetylcholine on heart rate and blood pressure. On the other hand, this pretreatment attenuated the sympathoadrenal effects of nicotine significantly. Chronotropic and blood pressure changes produced by histamine were also inhibited by ambrein pretreatment. This pretreatment significantly reversed the effects of atenolol but failed to demonstrate any change in the negative chronotropic, inotropic and hypotensive responses induced by verapamil. It is concluded that ambrein induced nonselective dose dependent antagonism of the effects of some agonists and antagonists require contribution of some neuromediators. However, the positive isotropic effects of ambrein possibly involve the enhancement of slow Ca channels and/or activation of ${\beta}-adrenergic$ receptors in the heart. At this moment it is difficult to explain the exact mode of action of ambrein and the studies dealing with Ca channel blocker and adrenergic blocker followed by ambrein may help to define the factors which contribute to its positive inotropic effects.

  • PDF

Evaluation of the Utility of a Volumetric Modulated Arc Therapy Specific Patient Quality Assurance using Software-based Quality Assurance System (소프트웨어 기반 정도관리 시스템을 이용한 부피세기조절회전치료 환자 별 정도관리의 유용성 평가)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Kwon, Kyung-Tae
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.39-45
    • /
    • 2018
  • The purpose of this study is to evaluate the usefulness of a software-based quality assurance system based on Volumetric Modulated Arc Therapy treatment plan. Evaluate treatment plan through the D VH analysis, PTV mean dose ($D_{mean}$) and PTV 95% dose($D_{95}$) compare the MFX based on original treatment plan, Average error rate was $0.9{\pm}0.6%$, $1.0{\pm}0.8%$, respectively. Measuring point dose using phantom and ion chamber, the average error rate between the ionization chamber and MFX was $0.9{\pm}0.7%$, $1.1{\pm}0.7%$ (high dose region), $1.1{\pm}0.9%$, $1.2{\pm}0.7%$ (low dose region). The average gamma though of MFX and $Delta^{4PT}$ is $98.7{\pm}1.2%$, $98.4{\pm}.3%$, respectively. Through this study, A software based QA system that simplifies hardware based QA procedures that involve a lot of time and effort. It can be used as a simple and useful tool in clinical practice.