• 제목/요약/키워드: Hierarchical Logic Based Expert System

검색결과 3건 처리시간 0.029초

계층 논리 기반 전문가 시스템의 전력계통 고장진단에의 적용 (Application of Hierarchical Logic Based Expert System to the Power System Fault Diagnosis)

  • 박영문;김광원;이광호;정재길
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.863-871
    • /
    • 1999
  • While Logic Based Expert System (LBES) has a merit of rapid and complete inference, it also has a defect of huge knowledge base. Hierarchical LBES (HLBES) replaces the assertion time inference of LBES with the multi-level logic minimization procedure, and it guarantees smaller knowledge base comparing with LBES. This paper has two contributions. The one is proposing so-called fact-minimization procedure which reduces not only the number of facts or measured events but also the size of knowledge base dramatically. The other contribution is application of HLBES and the proposed fact-minimization to the fault diagnosis of power system. The application is successfully performed in the example with the transmission system which takes 72 goals and 352 facts.

  • PDF

RVEGA 최적 퍼지 제어기를 이용한 비선형 시스템의 안정화 제어에 관한 연구 (Stabilization Control of the Nonlinear System using A RVEGA ~. based Optimal Fuzzy Controller)

  • 이준탁;정동일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.393-403
    • /
    • 1997
  • In this paper, we proposed an optimal identification method of identifying the membership func¬tions and the fuzzy rules for the stabilization controller of the nonlinear system by RVEGA( Real Variable Elitist Genetic Algo rithm l. Although fuzzy logic controllers have been successfully applied to industrial plants, most of them have been relied heavily on expert's empirical knowl¬edge. So it is very difficult to determine the linguistic state space partitions and parameters of the membership functions and to extract the control rules. Most of conventional approaches have the drastic defects of trapping to a local minima. However, the proposed RVEGA which is similiar to the processes of natural evolution can optimize simulta¬neously the fuzzy rules and the parameters of membership functions. The validity of the RVEGA - based fuzzy controller was proved through applications to the stabi¬lization problems of an inverted pendulum system with highly nonlinear dynamics. The proposed RVEGA - based fuzzy controller has a swing -. up control mode(swing - up controller) and a stabi¬lization one(stabilization controller), moves a pendulum in an initial stable equilibrium point and a cart in an arbitrary position, to an unstable equilibrium point and a center of the rail. The stabi¬lization controller is composed of a hierarchical fuzzy inference structure; that is, the lower level inference for the virtual equilibrium point and the higher level one for position control of the cart according to the firstly inferred virtual equilibrium point. The experimental apparatus was imple¬mented by a DT -- 2801 board with AID, D/A converters and a PC - 586 microprocessor.

  • PDF

PCR 과정의 오류 관리를 위한 Fault Tree Analysis 적용에 관한 시범적 연구 (Feasibility Study on the Fault Tree Analysis Approach for the Management of the Faults in Running PCR Analysis)

  • 임지수;박애리;이승주;홍광원
    • Applied Biological Chemistry
    • /
    • 제50권4호
    • /
    • pp.245-252
    • /
    • 2007
  • FTA(fault tree analysis)는 system 오류 관리를 위한 정성적/정량적 기법으로 적용되고 있다. FTA를 적용한 PCR의 오류 관리 system의 구축을 위한 시범적 단계로서 PCR 실행의 여러 단계 중 가장 간단한 단계인 '반응액의 제조 및 PCR 기기 사용 단계'를 모델로 하여 분석하였다. PCR 실행시 발생할 수 있는 오류를 연역적 논리 방식에 의해 fault tree의 형태로 규명하였다. Fault tree는 오류 관리의 최상위 요소인 top event를 중심으로 중간 계층을 이루는 intermediate events와 최하위의 요소인 basic events로 세분하여 구성하였다. Top event는 '반응액의 제조 및 PCR 기기 사용 단계에서의 오류'; 중간계층 events는 '기기 유래 오류', '실험행위 유래 오류'; basic events는 '정전상황', 'PCR 기기 선정', '기기 사용 관리', '기기 내구성', '조작의 오류', '시료 구분의 오류'로 분석되었다. 이로부터 top event의 원인 분석 및 중요 관리점을 도출하기 위하여 정성적/정량적 분석을 실시하였다. 정성적 기법으로 minimal cut sets, structural importance, common cause vulnerability를 분석하였고, 정량적 기법으로 simulation, cut set importance, item importance, sensitivity를 분석하였다. 정성적 분석과 정량적 분석의 결과에서 '시료 구분의 오류'와 '기기 조작의 오류'가 제 1중요관리점; '기기 관리의 오류'와 '내구성에 의한 오류'는 제 2중요관리점으로 일치되게 나타났다. 그러나 '정전상황'과 '기기 선정의 오류'는 정성적 분석에서만 중요관리점으로 분석되었다. 특히 sensitivity 분석에서 '기기 관리의 오류'는 사용 시간이 경과함에 따라 가장 중요한 관리점으로 부각되었다. 결론적으로 FTA는 PCR 모델 case에 대한 오류의 원인 분석 및 그 방지를 위한 중요관리점을 제시함에 따라, 궁극적으로 미래에 PCR의 오류 관리 system을 완성할 수 있는 효과적인 방법으로 사료된다.