• 제목/요약/키워드: Hi-Value

검색결과 354건 처리시간 0.026초

Effects of vacuum and high-oxygen modified atmosphere packaging on physico-chemical and microbiological properties of minced water buffalo meat

  • Jaberi, Rahimeh;Kaban, Guzin;Kaya, Mukerrem
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제32권3호
    • /
    • pp.421-429
    • /
    • 2019
  • Objective: In this study, the effects of vacuum (VP) and high-oxygen modified atmosphere ($80%\;O_2+20%\;CO_2$) packaging (HiOx-MAP) on physico-chemical and microbiological properties of minced water buffalo meat were investigated. Methods: After minced meat preparation, samples were packaged under VP and HiOx-MAP and stored at $2^{\circ}C{\pm}0.5^{\circ}C$ for 14 days. Samples taken on certain days were subjected to total aerobic mesophilic bacteria, total aerobic psychrotrophic bacteria, lactic acid bacteria, Pseudomonas, Enterobacteriaceae and yeast-mold counts as well as pH, color ($L^*$, $a^*$, and $b^*$) and thiobarbituric acid reactive substances (TBARS) analyses. Results: In minced water buffalo meat packaged under HiOx-MAP, TBARS value exceeded 1 mg malondialdehyde/kg on the 4th day of the storage. In VP samples, TBARS value remained close to initial TBARS value during storage. According to the findings, $a^*$ value was determined to be high in the HiOx-MAP samples within initial days of the storage. However, no significant changes in $a^*$ value were observed in VP samples during storage. In contrast, the mean value of $L^*$ was detected as higher in HiOx-MAP sample than VP samples. The count of psychrotrophic bacteria increased more than that of mesophilic bacteria during storage. The growth of Enterobacteriaceae and Pseudomonas was delayed in both the packaging methods. However, lactic acid bacteria exhibited more growth in VP samples compared to MAP samples. Conclusion: The lipid oxidation proceeded faster than expected in minced water buffalo meat packed with HiOx-MAP method. This situation adversely affected the $a^*$ value. On the other hand, similar microbiological results were obtained in both packing methods.

여러 스테인레스 스틸 호선의 물성 및 표면의 비교 (PHYSICAL PROPERTIES AND SURFACE TOPOGRAPHY OF ORTHODONTIC STAINLESS STEEL WIRES : COMPARING A NEW KOREAN PRODUCT WITH OTHERS FROM FOREIGN COMPANIES)

  • 이성호;김태우;장영일
    • 대한치과교정학회지
    • /
    • 제31권1호
    • /
    • pp.149-157
    • /
    • 2001
  • 본 연구의 목적은 새로이 생산된 국산 스테인레스 스틸호선의 특성을 평가하기 위하여, 현재까지 사용하고 있는 다른 스테인레스 스틸호선과 비교하여, 국산 스테인레스 스틸호선의 특성과 장단점을 분석하고 평가하여 임상적 사용시에 도움을 주고자 하는 것이다. 이를 위해 Unitek의 Standard, Resilient, Hi-T 3종류의 스테인레스 스틸호선과 Ormco 의 Stainless Steel, 진성기업의 Stainless Steel등 5종(0.016x0.022과 0.019x0.025)을 가지고 성분, 치수비교, 인장물성, 만곡피로도물성, 비틀림물성, 경도 및 표면등을 관찰하여 비교하여 다음과 같은 결론을 얻었다. 1. 인장물성을 보면, 최대강도는 0.016x0.025의 경우 Unitek Hi-T, Unitek Resilient, Jinsung Stainless Steel, Ormco Stainless Steel, Unitek Standard 순이고, 0.019x0.025의 경우 Unitek Hi-T, Jinsung, Ormco, Unitek Resilient, Unitek Standard 의 순이었다. 2. 연신율은 0.016x0.022의 경우는 Unitek Standard, Ormco Stainless Steel, Unitek Hi-T, Unitek Resilient, Jinsung Stainless Steel의 순이었고, 0.019x0.025의 경우는 Unitek Hi-T, Unitek Standard, Ormco Stainless Steel, Jinsung Stainless Steel, Unitek Resilient의 순이었다. 3. 탄성계수는 0.016x0.022의 경우 Jinsung Stainless Steel, Unitek Hi-T, Unitek Resilient, Ormco Stainless Steel, Unitek Standard의 순이었고, 0.019x0.025의 경우 Unitek Resilient, Jinsung Stainless Steel, Ormco Stainless Steel, Unitek Hi-T, Unitek Standard의 순이었다. 4. 만곡피로도실험은 0.016x0.022의 경우 Jinsung Stainless Steel이 8.4회로 구부림에 대한 가장 파절저항도가 컸으며, Unitek Hi-T, Unitek Standard, Unitek Resilient, Ormco Stainless Steel의 순이고 0.019x0.025의 경우는 Unitek Hi-T가 10.4회 견디고, Jinsung Stainless Steel, Unitek Resilient, Unitek Standard, Ormco Stainless Steel의 순이었다. 5. 비틀림실험은 0.016x0.022의 경우 Unitek Resilient가 가장 비틀림에 대한 저항이 큰데, 64.8회의 회전후 파절한다. 그 다음으로 Jinsung Stainless Steel, Unitek Hi-T, Ormco Stainless Steel, Unitek Standard(50.6회) 순이었다. 0.019x0.025의 경우 Jinsung Stainless Steel이 가장 커서 83.2회의 회전에 저항하고, Unitek Resilient, Unitek Standard의 순이고 Ormco와 Unitek Hi-T가 가장 저항력이 작았다. 6. 주사전자현미경으로 본 표면은 모든 제품에서 생산과정 중에 보이는 압흔과 pitting이 관찰되는데, 진성기업의 Stainless Steel은 가늘고 긴 압흔이 있으며 비교적 매끄러운 표면을 보이고, Unitek사의 경우 압흔과 함께 pitting 이 관찰되며, Ormco Stainless Steel의 경우 불규칙한 pitting이 다수 존재했다.

  • PDF

효율적 고속도로 설계VE 수행을 위한 Hi-Value 프로세스 정립 (A Hi-Value Process Establishment for Efficient Implement of Design Value Engineering in Highway)

  • 허인;이용구;정병천;양재경
    • 건설관리
    • /
    • 제12권6호
    • /
    • pp.36-48
    • /
    • 2011
  • 도로건설프로젝트에서의 VE는 도로시설물의 기능을 향상시키고 비용을 절감하기 위한 방법으로 지금까지 널리 활용되고 있다. 그러나, 실제 건설VE 실무에서는 VE Job Plan 중 일부 단계가 생략되거나 형식적으로 수행되는 문제점이 발생되어 VE 수행결과에 대한 신뢰성에 의문이 제기되고 있다. 이는 제조업과 달리 대규모이며 복합공종을 갖는 건설프로젝트의 특성을 반영하지 못하고 있기 때문이다. 건설프로젝트는 대규모 복합공종으로 구성되어 복잡하고 다양한 기능 및 요구성능이 있으며, 시설물이 갖는 기능(Function)과 요구성능(Required Performance)의 일부는 반복적으로 발생하는 특징을 가지고 있다. 이에 본 연구에서는 VE Process의 실효성을 높이기 위하여 품질모델(Quality Model)과 기능분석(Function Analysis)단계에서 이러한 특징을 반영한 개선방향을 제시하고, 수차례 실무 검증을 통하여 적용성 및 효율성을 확인하였다. 이와 더불어 고속도로 VE Job Plan은 고속도로 설계 업무절차에 부합하도록 개선하여 VE 수행효과가 극대화 되도록 제안하였으며, 또한 한국도로공사에서 시행하는 고속도로 대한 VE절차를 "Hi-Value"라 명명하고 실무활용성, 효율성을 확대하고 지속적으로 발전시켜 나아갈 계획이다.

건설기계 디젤엔진용 실시간 시뮬레이터 개발 (Development of Real-Time Simulator for a Heavy Duty Diesel Engine)

  • 노영창;박경민;오병걸;고민석;김낙인
    • 대한기계학회논문집A
    • /
    • 제39권2호
    • /
    • pp.203-209
    • /
    • 2015
  • 건설기계 산업에서 배기 및 연비 규제를 만족하기 위하여 엔진 시스템이 점차 전자제어화 되고 있으며, 이를 제어하기 위한 EMS(Engine Management System)의 복잡도 또한 증가하고 있다. 본 연구에서는 EMS function 개발 시, 비용 및 개발기간의 단축을 위한 HiLS(Hardware in the Loop Simulation) 시스템을 개발하였다. HiLS 에 내장된 엔진 모델은 크게 Air, Fuel, Torque 및 동력계 모델로 구성되어있고 실시간 엔진 모사를 위하여 Mean value modeling 방법을 적용하였다. 이 연구를 통하여 개발한 HiLS 시스템은 EGR(Exhaust Gas Recirculation) 시스템과 Turbocharger 가 장착된 건설기계용 디젤엔진을 이용하여 정확성을 검증하였고, 테스트 결과 실 엔진 대비 90% 이상의 정확도를 얻었다.

도축 육계에서 뉴캣슬형 바이러스에 대한 혈중항체가 조사 (A survey of newcastle disease virus antibody titers on slaughtered broiler chicks)

  • 이정원;허철호;이종환;권정택;송희종
    • 한국동물위생학회지
    • /
    • 제24권3호
    • /
    • pp.217-222
    • /
    • 2001
  • Hemagglutination inhibition(HI) titers of Newcastle disease(ND) were measured to investigate the vaccination times on three different species of broiler chicks in Chonbuk province. Each 330 of Cobb, Ross and White-semi broiler chicks were selected from 11 broiler farms. The primary vaccine were sprayed in hatchery at one day old chicks. Secondary and tertiary vaccine were used by drinking water at 7 to 24 days old chicks. The ND antibody titer were measured by HI from each different species of broiler chicks at the marketing date. Total average HI titers of Cobbs vaccinated with primary ones, secondary and tertiary ones were recorded 1.86, 1.52 and 2.76, respectively. The antibody titers were shown to 2.22, 2.13, 3.07 in terms of vaccination of Ross broiler chicks. They were also 2.56, 2.65 and 2.78 in terms of vaccination of White-semi broiler chicks. The value HI titer were not statistically different of all treatments. The results of this experiment suggested that HI titer of sera is scored less than defensive value of ND antibody titer at more than two times of vaccination.

  • PDF

$T_{b}$-$N_{HI}$ CORRELATION IN THE GALACTIC PLANE

  • Kim, Yong-Gi
    • Journal of Astronomy and Space Sciences
    • /
    • 제17권1호
    • /
    • pp.33-38
    • /
    • 2000
  • Synchrotron emission at 408 MHz and HI column density have been used to find an evidence for the relationship between the Galactic magnetic field and the gas density. The observational data of the brightness temperature and HI column density, $T_b(408)\;and \;N_{HI}$, near the galactic plane between galactic longitudes $l=62^{circ}\;and\;l=250^{\circ}$ show a clear linear correlation of $T_b(408)=A(l,b)+B\;N_{HI}$, where A(l, b)is a background and forground radiation at the galactic coordinate. We found $(1.4{pm}0.3)10^{-21}$ for the slope B, which describes the strength of the syncrotron radiation from the HI cloud, and agrees with the value for the MIlky Way obtained by Beuermann et al. (1985). We conclude therefore that a well defined nonthermal corelates with the HI column density originating from this HI cloud.

  • PDF

Effects of Supercritical CO2 Treatment on Color, Lipid Oxidation, Heme Iron, Non-Heme Iron and Metmyoglobin Contents in Ground Pork

  • Shirong Huang;Min Tang;Fenfen Chen;Shengnan Zhao;Dongfang Chen
    • 한국축산식품학회지
    • /
    • 제44권2호
    • /
    • pp.408-429
    • /
    • 2024
  • The color, lipid oxidation, heme iron (HI) and non-heme iron (NHI) contents, metmyoglobin content and Soret band of myoglobin of ground pork subjected to supercritical CO2 treatment under different conditions, or to heat treatment (40℃, 2 h) and subsequent storage at 4℃ were evaluated during 9-day period. Supercritical CO2 treatment significantly increased CIE L* and CIE b* values of ground pork during subsequent storage, while the HI content was slightly affected. In general, CIE a* value and metmyoglobin content were decreased. Supercritical CO2 treatment for 2 h could increase the thiobarbituric acid-reactive substances (TBARS) value, while treatment for 1 h or less had no effect. The NHI content could be increased only after treatment at above 40℃ or 17.2 MPa for 2 h. The Soret band of myoglobin was shifted to longer wavelength. Increasing treatment temperature from 35℃ to 45℃ could increase CIE L*, CIE a*, CIE b* and TBARS values, HI and NHI contents of the ground pork, while decreasing metmyoglobin content. As the treatment pressure increased from 13.8 MPa to 20.7 MPa, CIE b* and TBARS values were decreased, while the NHI and metmyoglobin contents were increased. However, the other parameters were unchanged. Extending exposure time from 0.5 h to 2 h could increase CIE L*, CIE b* and TBARS values, HI contents, while decreasing CIE a* value and metmyoglobin content. Correlation analysis showed that the TBARS value was significantly and negatively correlated with the HI content or metmyoglobin content in samples treated at 40℃ or above for 2 h.

Kinetic Properties of Wild-type and C117D Mutant UDP-N-Acetylglucosamine Enolpyruvyl Transferase (MurA) from Haemophilus influenzae

  • Han, Seong-Gu;Jin, Bong-Suk;Lee, Won-Kyu;Yu, Yeon-Gyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2549-2552
    • /
    • 2011
  • In this study, the kinetic properties of wild-type and C117D mutant H. influenzae MurA (Hi MurA), which catalyzes the first reaction in the biosynthetic pathway of the cell wall, were characterized. Purified recombinant Hi MurA was active at pH values ranging from pH 5.5 to pH 10, and its $K_m$ (UNAG), $K_m$ (PEP), and $k_{cat}$ values were measured to be 31 ${\mu}M$, 24 ${\mu}M$, and 210 $min^{-1}$, respectively. Hi MurA activity was effectively inhibited by fosfomycin with an $IC_{50}$ value of 60 ${\mu}M$. Hi MurA contains a cysteine residue (C117) at the loop region near the PEP binding, whereas MurA from fosfomycin resistant Mycobaterium tuberculosis or Chlamydia trachomatis contain an aspartate residue instead of the cysteine at the corresponding site. Aspartate substitution of Cys117 in Hi MurA shifted its optimum pH from 7.8 to 6.0. In addition, the $K_m$ values for UNAG and PEP were increased to 160 ${\mu}M$ and 150 ${\mu}M$, respectively, and the $k_{cat}$ value was significantly reduced to 41 $min^{-1}$. Furthermore, the C117D mutant form of Hi MurA was not inhibited by 1 mM fosfomycin. These results indicate that the Cys117 of Hi MurA is the binding site of fosfomycin and plays an important role in the fast turnover of the catalytic reaction.

A 235U mass measurement method for UO2 rod assembly based on the n/γ joint measurement system

  • Yang, Jianqing;Zhang, Quanhu;Su, Xianghua;Li, Sufen;Zhuang, Lin;Hou, Suxia;Huo, Yonggang;Zhou, Hao;Liu, Guorong
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.1036-1042
    • /
    • 2020
  • Fast-Neutron Multiplicity Counter based on Liquid Scintillator Detector can directly measure the fast neutron multiplicity emitted by UO2 rod. HPGe gamma spectrometer; which has superior energy resolution; is routinely used for the gamma energy spectrum measurement. Combing Fast-Neutron Multiplicity Counter and HPGe γ-spectrometer, the n/γ joint measurement system is developed. The fast neutron multiplicity and gamma energy spectrum of UO2 rod assemblies under different conditions are measured by the n/γ joint measurement system. The induced fission rate and the 235U abundance, thereby the 235U mass; can be obtained for UO2 rod assemblies. The 235U mass deviation of the measured value from the reference value is less than 5%. The results show that the n/γ joint measurement system is effective and applicable in the measurement of the 235U mass in samples.

Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study

  • Dalili, Zahra;Taramsari, Mehran;Mehr, Seyed Zoheir Mousavi;Salamat, Fatemeh
    • Imaging Science in Dentistry
    • /
    • 제42권1호
    • /
    • pp.19-24
    • /
    • 2012
  • Purpose : Field of view and voxel resolution of cone beam computed tomography (CBCT) might affect the diagnostic capability. This study was performed to compare between the standard and HiRes zoom modes in the diagnosis of external root resorption (ERR) using CBCT. Materials and Methods : Sixty three small cavities (0.25 mm depth and 0.5 mm diameter) were simulated on the buccal, lingual, and proximal surfaces at three different levels of 16 roots of teeth. After covering the root with nail varnish, the roots were inserted in the sockets and the model was placed in a water-containing lacuna. CBCT scans were taken in both standard and HiRes zoom modes using NewTom VG (QR srl Company, Verona, Italy). Then, an observer assessed the images to determine the presence or absence of the cavities. This process was repeated by increasing the size and depth of cavities to 0.5 mm depth and 1 mm diameter. Data were analyzed by McNemar test. The sensitivity, specificity, positive predictive value, negative predictive value, and likelihood ratio in evaluation of the simulated cavities were calculated. Results : There was a significant difference between the two imaging modes in diagnosing the shallow cavities (p=0.02).The sensitivity of the standard zoom in detecting the shallow cavities was lower than that of the HiRes zoom. The likelihood ratio of the HiRes zoom was higher in the diagnosis of both cavity types. Conclusion : This study suggested that a smaller voxel size in the HiRes zoom mode of CBCT is preferred for diagnosis of ERR.