• Title/Summary/Keyword: HgI2

Search Result 391, Processing Time 0.034 seconds

Fundamental studies on thermosolutal convection in mercurous bromide(Hg2Br2) physical vapor transport processes (브로민화 수은(I)(Hg2Br2) 물리적 증착공정에서 온도농도대류의 기초연구)

  • Geug Tae Kim;Moo Hyun Kwon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.110-115
    • /
    • 2023
  • During the Hg2Br2 physical vapor transport process, with increasing the partial pressure of component B, PB from 40 Torr to 200 Torr, a unicellular convective flow structures move from the crystal growth region to the center region in the vapor phase. The boundary layer flow is dominant for PB = 40 Torr, and the core region flow is dominant for PB = 200 Torr. The flow in the vapor phase shows a three-dimensional convective flow structure with a single cell (unicellular) for PB = 40 Torr and 200 Torr, exhibits an asymmetrical flow with respect to the x, y central axis under the horizontally oriented configuration with an aspect ratio (length-to-width) of 3 and linear conducting walls. The critical temperature difference between the source and crystal region is about 30 K. The total molar flux of Hg2Br2 increases with the temperature difference until the total molar flux reaches the critical value. At the critical total molar flux, the total molar flux abruptly decreases.

Inhibitory Effect of Enalapril in Combination with Ginkgo biloba Extract (EGb 761) on the Monocrotaline-induced Pulmonary Hypertension Rats (Monocrotaline에 의해 유발된 폐고혈압 흰쥐에 있어 Enalapril 및 Ginkgo biloba Extract(EGb 761)의 병용 투여시 억제효과)

  • 이영미;안형수;임세진;안령미
    • YAKHAK HOEJI
    • /
    • v.43 no.4
    • /
    • pp.487-493
    • /
    • 1999
  • Effects of Ginkgo biloba extract (EGb 761) on the anti-pulmonary hypertensive action of enalapril were evaluated in rats. Pulmonary hypertension was induced by monocrotaline treatment (60mg/kg, i.p.) in normotensive rats. In the systolic pulmonary artery pressure, the control group was 33$\pm$2 mmHg, comparing to the normal group of 19$\pm$1 mmHg. That of enalapril group(20mg/kg/day, p.o.) was 26$\pm$2 mmHg. In the isolated lung preparation, acetylcholine, which was endothelium dependent vasodilator, induced the decrease of pulmonary artery perfusion pressure(-2.0$\pm$0.7 mmHg) in normal group, but the increase of that of 3.4$\pm$0.6 and 3.0$\pm$0.9 mmHg in control and enalapril group, respectively. And that of the combined group was -0.5$\pm$0.2 mmHg. In the isolated pulmonary artery, acetylcholine(10-5M) induced the relaxation of 65$\pm$6% in normal group, but 15 and 8% in control and enalapril group, respectively. And that of the combined group was resulted 55$\pm$2%. These results suggested that co-administration of Ginkgo biloba extract(EGb 761) potentiated the anti-pulmonary hypertensive effects of enalapril through the increase of pulmonary vasodilation due to the protection of endothelial cell by antioxidant action of Ginkgo biloba extract (EGb 761).

  • PDF

Comparison of the Low Potassium Dextran Solution and ET-Kyoto Solution in Rabbit Lung (토끼 폐장 분리관류 모형을 이용한 LPD 폐보존액과 ET-Kyoto 폐보존액의 비교)

  • Lim, Cheong;Kim, Kyung-Hwan;Kim, Young-Tae;Sung, Sook-Whan;Kim, Joo-Hyun
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1159-1166
    • /
    • 1997
  • For Improvement of lung preservation, many tripes of preservation solution were developed and tested. The aim of this study was to compare the effect of the most frequently used extracellular type pieservation solution (Low Potassium Dextran, LPD) with a newly developed trehalose containing extracellular type preservation solution(ET-Kyoto, ETK) on postischemic lung function. Twelve New-Zealand white rabbit lungs were harvested and studied on an isolated, blood-perfused model of lung function after 4 hours of cold ischemia at $10^{\circ}C$ In group I (n=6), lungs were preserved with 100 mL/kg of LPD solution; in group II(n=6), lungs were preserved with 100 mL/kg of ETK solution. A few minutes before flushing with preservation solutions, 20$\mu\textrm{g}$ of PGEI were injected into main pulmonary artery. Functions of the preserved lung were compared with PO2, PA pressure, t acheal air pressure, and drylwet ratio. The pulmonary efferent blood oxygen tension at the end of the 60-minute reperfusion period was higher in group II compacted with group I(486.5 $\pm$ 80.3 mmHg versus $432.5\pm82.9$ mmHg at FiO2 1.0, p-value = NS). The mean pulmonary arterial pressure was similar in both $groups.(33.7\pm2.2$ mmHg versus $35.5\pm2.0$ mmHg, p-value : NS). The peak inspiratory airway pressure was significantly lower in group 11(8.010.6 mmHg versus 11.8 $\pm$ 1.4 mmHg, p-value=0.02) The water content of the lung was lower in group II $(70.2\pm6.9%$ versus 78.5 $\pm6.1%),$ but not significant. These data demonstrate that a newly-developed trehalose-containing ET-Kyoto solution yield equal or slightly superior lung function after reperfusion compared with LPD solution.

  • PDF

양산에 적합한 구조의 X-ray 검출기 공정에 대한 연구

  • Gwon, Jun-Hwan;O, Gyeong-Min;Song, Yong-Geun;Kim, Ji-Na;No, Seong-Jin;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.265-266
    • /
    • 2012
  • 의료용 X-ray의 발전에 따라, 영상의 Digital화가 필요하게 되었다. Digital 영상 구현을 위해 다양한 형태의 영상 검출기가 개발되었다. 진단 영상의 조건으로는 구현 시간이 빠르고 해상도가 높아야 한다. 조건에 부합하는 Flat panel 형태의 직접방식과 간접방식 검출기의 개발이 주로 이루어졌으며, X-ray 검출 효율이 높고 공간 분해능이 높은 직접 방식의 검출기에 대한 연구가 활발히 진행되고 있다. 기존 직접방식의 X-ray 검출물질로는 A-Se이 이용되었다. 하지만 A-Se의 경우 낮은 원자번호로 인해 X-ray에 대한효율이 낮으며, 제조 공정과 수율의 문제로 인해 대체 물질의 개발과 공정의 개선이 필요하다. 선행 연구를 통해 X-ray 검출물질의 전기적 특성을 파악을 통해 대체 물질로서 가능성을 알아보았다. 본 연구에서는 기존에 제작된 X-ray 검출물질의 상부전극 증착 물질과 증착법 선정에 대한 연구이다. 선행 연구를 통해 선정된 X-ray 검출물질은 HgI2이다. 상, 하부 전극 선택에 있어 HgI2의 일함수 값(4.15eV)을 고려하여 그와 비슷한 일함수 값을 가진 물질로 전기적 장벽을 제거하여야 한다. 따라서, ITO (일함수 4.45eV)와 Au (일함수 5.1eV)을 선택하였다. ITO의 증착으로 이용된 방법으로는 on-axis 형태의 magnetron plasma sputtering을 이용하였으며, Au의 증착으로 이용된 방법은 Thermal evaporation deposition을 이용하였다. plasma sputtering에 이용된 타겟은 In2O3;SnO2 (조성비:90:10wt%)를 사용하였으며, Chamber의 크기는 넓이 456 ${\phi}cm^2$ 높이 25 cm이며, 로 target과 기판과의 거리는 15cm이다. plasma발생에 필요한 가스로는 Ar과 O2를 이용하였다. 고 진공 환경 조성에 이용된 장비로는 Rotary pump와 Turbo molecular pump이다. plasma 발생 전 진공도는 $3.2{\times}10^{-5}$ Torr, 발생 후 진공도는 $5.1{\times}10^{-5}$ Torr이다. plasma 환경이 조성된 후 증착 시간은 1분 30초이다. Au는 순도 99.999%를 이용하였으며, 이용된 금은 1회 증착에 0.3 g을 이용하였다. Chamber의 넓이 1,444 ${\phi}cm^2$이며, 높이 40 cm, boat와 기판과의 거리는 25 cm이다. 고 진공 환경 조성에 이용된 장비로는 Rotary pump와 diffusion pump를 이용하였다. Au의 승화 전 진공도는 $2.4{\times}10^{-5}$ Torr 증착 시 진공도는 $4.2{\times}10^{-5}$ Torr이며, Boat에 가해준 전압, 전류는 0.97 V, 47 A이며, 증착 시간은 1분 30초이다. 광도전체 층에 각각 증착된 전극의 저항을 통해 증착상태를 판단하였다. DMM (Digital Multimeter)로 1 cm 간격으로 측정된 표면의 저항은 ITO 약 $8{\Omega}$, Au 약 $3{\Omega}$으로 전극으로서 이용이 가능한 상태이다. Au와 ITO가 증착된 HgI2 시편의 전기적 특성은 기존에 이용된 X-ray 변환물질의 성능보다 우수하였다. 하지만 Au와 ITO가 각각 증착된 시편의 전기적 특성은 큰 차이를 보이지 않았다. ITO의 경우 진공 상태에서 이용되는 Gas가 이용되며, Plasma 환경 조성 유지가 어려운 점이 있다. Au전극은 증착 환경 조성이 쉽지만, 전극 물질 이용효율이 떨어지는 단점이 있다. 본 연구를 통해 X-ray 변환물질인 HgI2의 전극물질로 Au와 ITO의 이용가능성을 알아보았다. 두 전극으로 제작된 검출기의 성능은 큰 차이 없이 우수하였고, 전기적 장벽 상태가 낮아 높은 검출 효율을 보였다. 상대적으로 Au 전극의 공정이 간단하고 수율이 높다. 하지만 Au Source의 이용 효율이 떨어지는 단점이 있다. 본 연구의 결과를 통해 공정상의 유리함과 Source의 이용효율을 고려한 분석에 대한 연구가 필요할 것으로 사료된다.

  • PDF

Surgical treatment of Supravalvular Aortic Stenosis (판막상부 대동맥협착증의 외과적 요법)

  • 장우익;오삼세;이정렬;김용진;노준량;서경필
    • Journal of Chest Surgery
    • /
    • v.31 no.8
    • /
    • pp.763-769
    • /
    • 1998
  • Background: Supravalvular aortic stenosis is a rare form of congenital cardiac anomaly involving ascending aorta distal to coronary orifice. Materials and methods: We operated 12 cases of supravalvular aortic stenosis between July 1986 and March 1997. Age ranged from 4 to 17(mean 10.2) years and 11 of them were male. Nine patients had clinical features of Williams syndrome. We experienced two types of supravalvular aortic stenosis, including 10 hour glass type and 2 diffuse type. Results: Preoperative transaortic pressure gradient ranged from 40 to 180(mean 92) mmHg by cardiac catheterization. Pulmonary stenosis was associated in 5 and 2 of them required angioplasty. Operative techniques included 6 standard aortoplasty with elliptical patch, 4 extended aortoplasty with inverted Y shaped patch, and 2 modified Brom's repair. There were no operative deaths. Postoperative echocardiographic evaluation was done at a mean interval of 12 months. Grade I or II aortic regurgitation was found in 3 cases. Postoperative cardiac catheterization revealed a mean transaortic pressure gradient of 26 (range 0 to 75) mmHg. A mean pressure drop was 78(range 30 to 114) mmHg. All patients were followed up for a mean of 40(range 1 to 67) months with uneventful clinical course. Conclusions: Our data proved the low mortality and excellent hemodynamic improvement after surgical relief of supravalvular aortic stenosis in children.

  • PDF

The Effect of Smilacis glabrae Rhizoma aqua-acupuncture on injured kidneys Induced by $HgCl_2$ Intoxication in Rats (토복령약침자극(土茯笭藥鍼刺戟)이 $HgCl_2$중독(中毒) 흰쥐의 손상신(損傷腎)에 미치는 영향(影響))

  • Jung Hye-Yoon;Kang Sung-Keel;Kim Yong-Suk;Park Young-Bae;Koh Hyung-Kyun;Kim Chang-Hwan
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.331-348
    • /
    • 1998
  • Purpose: In order to study the therapeutic effect of TBR(Smilacis glabrae Rhizoma) aqua-acupuncture on the $HgCI_2$(mercury bichloride) intoxicated kidneys of rats. Methods: 10% TBR extract solution was aqua-punctured into the bilateral loci of Shin-su(BL23), every other day for 18 days, and the amount of leucocytes, erythrocytes, thrombocytes, hematocrit, hemoglobin, serum BUN and creatinine levels were measured and renal mercury level and histopathological findings were studied as well. The experimental groups were into nonmaI group, control group, sample I group, sample II group and sample III group. Results: 1. There were not any significant changes of leucocytes, erythrocytes and serum creatinine level in the TBR aqua-acupuncture group, saline aqua-acupuncture group and TBR aqua-acupuncture group respectively as compared with control group. 2. It showed a significant increase of hematocrit and hemoglobin level in the TBR aqua-acupuncture group on the 8th experimental day as compared with the control group. 3. It showed a significant increase of platelet in the TBR aqua-acupuncture group on the 8th experimental day, whereas significant decreases on the 18th experimental day as compared with the control group. 4. It showed a significant decrease of serum BUN level in the TBR aqua-acupuncture group on the 8th and 18th experimental day as compared with the control group. 5. It showed a significant decrease of renal mercury level in the TBR aqua-acupuncture group on compared with the control group. 6. In the histopathological findings, TBR aqua-acupuncture group showed slight atrophy of the renal tubules, mitosis and regeneration of tubular lining cells with visible nuclei, whereas the control group showed acute tubular necrosis, especially severe necrosis of tubular epithelial cells. Conclusions: Smilacis glabrae Rhizoma aqua-acupuncture on injured kidneys Induced by HgCl2 Intoxication in Rats increases hematocrit, hemoglobin and platelet level, and decreases BUN, renal mercury level. This suggests that Smilacis glabrae Rhizoma aqua-acupuncture helps to recover kidney from HgCl2 intoxication.

  • PDF

Study on the effect of DSSC(Dye Sensitizer Solar Cell) Material on the electrical properties of Mercuric Iodide (염료감응형태양열 물질이 요오드화수은의 전기적 특성에 미치는 영향에 관한 연구)

  • Cho, Gyu-Seok;Park, Ji-koon;Heo, Seung-Wook;Song, Yong-keun;Han, Moo-Jae;Kim, Kum-Bae;Choi, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.525-529
    • /
    • 2017
  • As a photoconductive material with a high X-ray sensitivity, many researches about mercury iodide has been carried out to substitute for amorphous selenium. However, it has many limitations in commercialization because of the high leakage current. In this study, we fabricated $HgI_2$ unit-cells with mixed silicon oxide($SiO_2$) and titanium oxide($TiO_2$) to reduce a high leakage current and we evaluated an electrical properties of the fabricated unit-cells. As a result, we confirmed that both mixtures were effective in reduing the leakage current of the $HgI_2$ and x-ray sensitivity were significantly increased in fabricated $HgI_2-TiO_2$ unit-cell.

Association between prehospital i-gel insertion and PCO2 in patients with out-of-hospital cardiac arrest

  • Cho, Eunsom;Cho, Eun-Hye;Kim, Hyuk-Hoon;Choi, Sang-Cheon;Min, Young-Gi;Kang, So Young;Chae, Minjung Kathy
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.578-584
    • /
    • 2018
  • Objective: This study examined the initial partial pressure of carbon dioxide ($PCO_2$) as a possible indicator of prehospital ventilation and its association with prehospital i-gel in out-of-hospital cardiac arrest (OHCA) patients. Methods: The demographics and arrest parameters, including i-gel insertion and initial arterial blood gas analysis, of OHCA patients who visited the emergency department were analyzed retrospectively. Linear regression analysis was performed to examine the association between i-gel insertion and the initial $PCO_2$. Results: A total of 106 patients were investigated. Fifty-six patients had prehospital i-gel insertion and 50 patients did not have a prehospital advanced airway. The initial $PCO_2$ was higher in the i-gel group than the no advanced airway group (105.2 mmHg [77.5-134.9] vs. 87.5 mmHg [56.8-115.3], P=0.03). Prehospital i-gel insertion was associated with a higher initial $PCO_2$ level (${\beta}$ coefficient, 20.3; 95% confidence interval, 2.6-37.9; P=0.03). Conclusion: Prehospital insertion of i-gel was associated with higher initial $PCO_2$ values in OHCA patients compared to no advanced airway.

Antioxidant Responses in Brackish Water Flea Diaphanosoma celebensis - Exposed to Mercury (수은 노출에 대한 기수산 물벼룩 Diaphnosoma celebensis의 항산화 반응)

  • Bae, Chulhee;Lee, Young-Mi
    • Journal of Marine Life Science
    • /
    • v.3 no.2
    • /
    • pp.74-80
    • /
    • 2018
  • Mercury (Hg) poses a threat to marine ecosystem due to continuous inflow from various industries and bioaccumulation to higher trophic level via food web. Mercury can adversely affect growth, development, reproduction and metabolism to aquatic organisms. In the present study, acute toxicity and oxidative stress markers (total glutathione content, and activities of GST, GR and GPx) were investigated in brackish water flea Disphanosoma celebensis exposed to HgCl2 for 24 h. As results, Hg showed negative effect in survival of D. celebensis. 24 h-LC50 value was determined as 0.589 mg/l (95% C.I. 0.521~0.655 mg/l). After exposure to Hg (0.08 and 0.4 mg/l) for 24 h, total glutathione content was significantly decreased, whereas GST, GPx and GR activities were enhanced. These findings indicate that Hg induced oxidative stress in D. celebensis, and oxidative stress markers may be involved in cellular defense against Hg - mediated toxicity. This study provides a better understanding of molecular mode of action of Hg toxicity in this specie and potent of molecular markers for heavy metal monitoring in marine ecosystem.

High Performance of SWIR HgCdTe Photovoltaic Detector Passivated by ZnS

  • Lanh, Ngoc-Tu;An, Se-Young;Suh, Sang-Hee;Kim, Jin-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.128-132
    • /
    • 2004
  • Short wave infrared (SWIR) photovoltaic devices have been fabricated from metal organic vapour phase epitaxy (MOVPE) grown n- on p- HgCdTe films on GaAs substrates. The MOVPE grown films were processed into mesa type discrete devices with wet chemical etching employed for meas delineation and ZnS surface passivatlon. ZnS was thermally evaporated from effusion cell in an ultra high vacuum (UHV) chamber. The main features of the ZnS deposited from effusion cell in UHV chamber are low fixed surface charge density, and small hysteresis. It was found that a negative flat band voltage with -0.6 V has been obtained for Metal Insulator Semiconductor (MIS) capacitor which was evaporated at $910^{\circ}C$ for 90 min. Current-Voltage (I-V) and temperature dependence of the I-V characteristics were measured in the temperature range 80 - 300 K. The Zero bias dynamic resistance-area product ($R_{0}A$) was about $7500{\Omega}-cm^{2}$ at room temperature. The physical mechanisms that dominate dark current properties in the HgCdTe photodiodes are examined by the dependence of the $R_{0}A$ product upon reciprocal temperature. From theoretical considerations and known current expressions for thermal and tunnelling process, the device is shown to be diffusion limited up to 180 K and g-r limited at temperature below this.