• Title/Summary/Keyword: HgI2

Search Result 387, Processing Time 0.024 seconds

Study on electrical properties of photoconductors for radiation detector application based on liquid crystal (액정 기반 방사선 검출기 적용을 위한 광도전체의 전기적 특성 연구)

  • Kang, Sang-Sik;Choi, Young-Zoon;Lee, Mi-Hyun;Kim, Hyun-Hee;No, Si-Chul;Cho, Kyu-Suck;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.27-30
    • /
    • 2010
  • A X-ray optical modulator measures x-ray dose using optical transmissivity ratio change of the liquid crystal cell. To apply in this optical modulator, we made photoconductor films and compared electrical properties of this films in this study. Photoconductors are deposited on ITO glass with $200{\mu}m$ using the percipitation method and print method. I-V test was conducted to alalyze electrical properties of this films and measured darkcurrent and SNR was acquired using the measured dark current and sensitivity. As a result of this measurements, $HgI_2$ film made by precipitation method is lower(about 40%) darkcurrent than $HgI_2$ films made by precipitation method and sensitivity is two times greater than print method. And we knew that $HgI_2$ films were also 10~25 times greater SNR at $1v/{\mu}m$ than $PbI_2$, PbO, CdTe film made by precipitation method. This results suggest that $HgI_2$ films made by precipitation method has improved characteristics of x-ray dose meter by applying in x-ray optical modulator.

Study on the Applicability of Semiconductor Compounds for Dose Measurement in Electron Beam Treatment (전자선 치료 분야의 선량 측정을 위한 반도체 화합물의 적용가능성 연구)

  • Yang, Seungwoo;Han, Moojae;Shin, Yohan;Jung, Jaehoon;Choi, Yunseon;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • In this study, it was intended to replace the existing plane parallel ionization chamber, which requires cross-calibration in electron beam treatment. The semiconductor compounds HgI2 was fabricated as detector, and the characteristics of HgI2 detector for the 6, 9 and 12 MeV electron beam was analyzed in the linear accelerator. It was also intended to evaluate the possibility of substitution with existing detectors and their applicability as electron beam dosimetry and to use them as a basic study of the development of electronic beam dosimeter. As a result of reproducibility, RSD was 0.4246%, 0.5054%, and 0.8640% at 6, 9, and 12 MeV energy, respectively, indicating that the output signal was stable. As a result of the linearity, the R2 was 0.9999 at 6 MeV, 0.9996 at 9 MeV, and 0.9997 at 12 MeV showed that the output signal is proportional to HgI2 as the dose is increased. The HgI2 detector of this study is highly applicable to electron beam measurement, and it may be used as a basic research on electron beam detection.

Methylmercury Toxicity Is Induced by Elevation of Intracellular $Ca^{2+}$ through Activation of Phosphatidylcholine-Specific Phospholipase C

  • Chin, Mi-Reyoung;Kang, Mi-Sun;Jeong, Ju-Yeon;Jung, Sung-Yun;Seo, Ji-Heui;Kim, Dae-Kyong
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.10a
    • /
    • pp.13-13
    • /
    • 2003
  • Methylmercury (MeHg) is a ubiquitous environmental toxicant that can be exposed to humans by ingestion of contaminated food including fish and bread. MeHg has been suggested to exert its toxicity through its high reactivity to thiols, generation of arachidonic acid and reactive oxygen species (ROS), and elevation of intracellular $Ca^{2+}$ levels ([$Ca^{2+}$$_{i}$). However, the precise mechanism has not been fully defined. Here we show that phosphatidylcholine-specific phospholipase C (PC-PLC) is a critical pathway for MeHg-induced toxicity. MeHg activated the acidic form of sphingomyelinase (A-SMase) and group IV cytosolic phospholipase $A_2$ ($cPLA_2$) downstream of PC-PLC, but these enzymes as well as protein kinase C were not linked to MeHg's toxicity. Furthermore, MeHg produced ROS, which did not cause the toxicity. However, D6O9, an inhibitor of PC-PLC, significantly reversed the toxicity in a time- and dose-dependent manner in MDCK and SH-5YSY cells. Addition of EGTA to culture media resulted in partial decrease of [$Ca^{2+}$$_{i}$ and partially blocked cell death. In contrast, D609 completely prevented cell death with parallel decreases in diacylglycerol and [$Ca^{2+}$$_{i}$. Together, our findings indicated that MeHg-induced toxicity was caused by elevation of [$Ca^{2+}$]$_{i}$ through activation of PC-PLC. The toxicity was not attributable to the signaling pathways such as $cPLA_2$, A-SMase, and PKC, or to the generation of ROS.

  • PDF

Chlorophyll a Fluorescence Response to Mercury Stress in the Freshwater Microalga Chlorella Vulgaris (담수산 클로렐라(Chlorella vulgaris)의 수은 스트레스에 대한 엽록소형광 반응)

  • Oh, Soonja;Koh, Seok Chan
    • Journal of Environmental Science International
    • /
    • v.22 no.6
    • /
    • pp.705-715
    • /
    • 2013
  • The response of the freshwater microalga Chlorella vulgaris to mercuric ion ($Hg^{2+}$) stress was examined using chlorophyll a fluorescence image analysis and O-J-I-P analysis as a way to monitor the toxic effects of mercury on water ecosystems. The levels of photosynthetic pigments, such as chlorophyll a and b and carotenoids, decreased with increasing $Hg^{2+}$ concentration. The maximum photochemical efficiency of photosystem II(Fv/Fm) changed remarkably with increasing $Hg^{2+}$ concentration and treatment time. In particular, above $200{\mu}M\;Hg^{2+}$, considerable mercury toxicity was seen within 2 h. The chlorophyll a fluorescence transient O-J-I-P was also remarkably affected by $Hg^{2+}$; the fluorescence emission decreased considerably in steps J, I, and P with an increase in $Hg^{2+}$ concentration when treated for 4 h. Subsequently, the JIP-test parameters (Fm, Fv/Fo, RC/CS, TRo/CS, ETo/CS, ${\Phi}_{PO}$, ${\Psi}_O$ and ${\Phi}_{EO}$) decreased with increasing $Hg^{2+}$ concentration, while N, Sm, ABS/RC, DIo/RC and DIo/CS increased. Therefore, a useful biomarker for investigating mercury stress in water ecosystems, and the parameters Fm, ${\Phi}_{PO}$, ${\Psi}_O$, and RC/CS can be used to monitor the environmental stress in water ecosystems quantitatively.

Potentiometric Measurement of Standard Potential of Mercury and Ion-pair Formation Constants of Mercuric Halides in Anhydrous Ethylenediamine (에틸렌디아민 非水溶液中에서의 水銀電極의 標準電位 및 水銀鹽化鹽의 Ion-Pair 恒數測定)

  • Kim, Joon-Yong
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.13-18
    • /
    • 1970
  • 非水溶液 Ethylenediamine 中에서 水銀電極의 標準電位 및 水銀鹽化物, $HgCl_2,\;HgBr_2,\;HgI_2$의 Ion-Pair 形成恒數를, Hg電極/$HgX_2$ 또는 $HgX_2$+NaX//亞鉛아마르감 參照電極과 같은 Cell의 構成으로서 電位差法에 依하여 測定하였다.

  • PDF

The Evaluation and Fabrication of Photoconductor Sensor for Quality Assurance of Radiation Therapy Devices (방사선치료기기 정도관리를 위한 광도전체 센서 제작 및 평가)

  • Kang, Sang Sik;Noh, Sung Jin;Jung, Bong Jae;Noh, Ci Chul;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.565-569
    • /
    • 2016
  • Recently, a use of linear accelerator with a multi-leaf collimator(MLC) for radiation therapy is increasing. The importance of quality assurance (QA) for the linear accelerator is emphasized as the side effects of the inaccurate delivery of the radiation beam has been increased according to the high dose irradiation technique. In this study, The $HgI_2$ and $PbI_2$ photoconductor layer samples of $400{\mu}m$ thickness were fabricated using sedimentation method among particle-in-binder technology. From the fabricated samples, the electrical properties(dark current, output current, response properties and linearity) were investigated. From the experimental results, $HgI_2$ has good charge signal generation and linearity. Finally, from the signal response results about various thickness of $HgI_2$ sensor, the signal creation efficiency of $400{\mu}m$ thickness of $HgI_2$ sensor has the highest value and the excellent reproducibility below ${\pm}2.5%$.

Polarographic Behaviors of Copper and Cadmium Complexes with 2,2'-Bipyridine and Ethylenediamine in Acetonitrile (아세토니트릴에서 구리와 카드뮴의 2,2'-Bipyridine과 Ethylenediamine 착물에 대한 폴라로그래프적 연구)

  • Park, Du Won;Lee Heung Lark;Bae Zun Ung
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.3
    • /
    • pp.202-209
    • /
    • 1974
  • Polarographic behaviors of copper and cadmium complexes with 2,2'-bipyridine and ethylenediamine in acetonitrile have been investigated by the DC and AC polarography. The reduction processes are estimated as follows; $Cu(II)-bipy. \;complex\;{\longrightarrow^{e^-}_{E_{1/2}\risingdotseq+0.1V}}\;Cu(I)-bipy.\;complex\;{\longrightarrow^{e^-}_{E_{1/2}=-0.43V}}\;Cu(Hg)$$Cu(II)-en.\;complex\;{\longrightarrow^{e^-}}\;Cu(I)-en.\;complex\;{times}\;{\longrightarrow^{e^-}_{E_{1/2}=-0.56V}}\;Cu(Hg)$$Cu(II)-bipy. \;complex\;{\longrightarrow^{e^-}_{E_{1/2}=-0.57V}}\;Cu(I)-bipy.\;complex\;{\longrightarrow^{2e^-}_{E_{1/2}=-0.97V}}\;Cd(I)-bipy\;complex$$Cu(II)-en.\;complex\;{\longrightarrow^{e^-}_{E_{1/2}=+0.05V}\;Cu(I)-en.\;complex{\longrightarrow^{e^-}_{E_{1/2}=-0.92V}}\;Cu(Hg)$ The limiting currents of all steps are controlled by diffusion. The number of ligand and the dissociation constant for Cu(Ⅰ)-bipy. complex were found to be n = 2 and $K_d=(1.5{\pm}0.1){\times}10^{-7}$, respectively.

  • PDF

Optical properties of $HgGa_2S_4$ single crystal ($HgGa_2S_4$ 단결정의 광학적 특성)

  • Kim, H.G.;Kim, N.O.;Kim, B.C.;Choi, Y.I.;Kim, D.T.;Hyun, S.C.;Bang, T.H.;Lee, K.S.;Gu, H.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05c
    • /
    • pp.47-52
    • /
    • 2004
  • $HgGa_2S_4$ single crystals were grown by the chemical transport reaction method. The $HgGa_2S_4$ single crystal crystallized into a defect chalcopyrite structure $(I\bar{4})$. The lattice constants of the single crystal were found to be a=5.635 ${\AA}$ and c=10.473 ${\AA}$. The direct and indirect optical energy gaps were found to be 2.84 eV and 2.78 eV, respectively. Photoluminescence peaks of $HgGa_2S_4$ single crystal were observed at 2.37 eV, 2.18 eV, and 1.81 eV. In the single crystal, the donor level of 0.25 eV, the acceptor levels of 0.97 eV and 0.41 eV were obtained by TSC, PICTS, and absorption measurements. The photoluminescence peaks were analyzed to relate to the indirect conduction band, the donor level, and the acceptor levels.

  • PDF

Characterization studies of digital x-ray detector based on mercuric iodide (Mercuric iodide 기반의 디지털 X-선 검출기의 특성 연구)

  • Cho, Sung-Ho;Park, Ji-Koon;Choi, Jang-Yong;Suck, Dae-Woo;Cha, Byung-Yul;Nam, Sang-Hee;Lee, Byum-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.392-395
    • /
    • 2003
  • For the purpose of digital x-ray imaging, many materials such as $PbI_2$, $HgI_2$, TlBr, CdTe and CdZnTe have been under development for servaral years as direct converter layer. $Hgl_2$ film detector have recently been shown as one of the most promising semiconductor materials to be used as direct converters in x-ray digital radiography. This paper, the $HgI_2$ films are deposited on conductive-coated glass by screen printing, in which $HgI_2$ powder is embedded in a binder and solvent, and the slurry is used to coat the conductive-coated glass. We investigated electrical characteristic of the fabricated $HgI_2$ films. The x-ray response to radiological x-ray generator of 70Kvp using the current integration mode will be reported for screen printing films. These results indicate that $HgI_2$ detectors have high potential as new digital x-ray imaging devices for radiography.

  • PDF

Characteristic Evaluation of Mercury lodide Film for Fluoroscopy Application (Fluoroscopy 적용을 위한 Mercuric lodide film 특성 평가)

  • Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Hoo;Yoon, Kyoung-Jun;Kang, Hyun-Gyu;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.494-497
    • /
    • 2004
  • 본 연구는 방사선 영상센서 적용을 위한 $HgI_2$ 필름의 특성 평가에 관한 것으로서 X-선 조사조건별 인가전압에 따른 검출신호 특성을 조사하였다. 기존의 $HgI_2$ 검출기의 경우 신호량이 크다는 장점이 있으나 노이즈의 양이 크다. 이에 대한 해결책으로 보호층을 삽입하나 이 경우 X-선 조사에 따른 시간 응답 특성이 있어서 전하트랩현상(tailing effect)에 의한 영향이 크게 존재하였다. 따라서 본 논문에서는 이러한 문제점을 해결하고자 보호층으로써 a-Se 을 삽입하여 기존의 $HgI_2$ 검출기에서 사용되어지는 parlyene이 삽입된 검출기와 전기적 특성을 측정, 비교해보고자 한다. 제작방식으로는 대면적 제작이 용이한 스크린 프린팅 방식을 이용하여 두께 $140\;{\mu}m$$3\;cm\;{\times}\;2\;cm$ 면적으로 제조하였다. 측정결과, a-Se을 보호층으로 사용한 $HgI_2$ 필름이 민감도는 거의 비슷하나 누설전류가 안정화 되는데 걸리는 감소시간(decay time)이 parlyene을 사용한 구조에 비해 훨씬 낮았다. 또한 X선에 대한 민감도는 기존의 a-Se에 비해 월등히 높아 적은 방사선 조사량(radiation dose)에서도 신호검출이 가능하여 저선량이 요구되는 방사선 투시촬영(digital fluoroscopy) 적용에 유용할 것으로 기대된다.

  • PDF