• Title/Summary/Keyword: Hexadentates Schiff's base

Search Result 2, Processing Time 0.016 seconds

Novel Copper(Ⅱ)-Selective Senor Based on a New Hexadentates Schiff's Base

  • Ganjali, Mohammad Reza;Emami, Mehdi;Salavati Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.10
    • /
    • pp.1394-1398
    • /
    • 2002
  • A novel copper(II) membrane electrode based on diphenylisocyanate bis(acetylacetone) ethylenediimine (DIBAE), as a new hexadentates Schiff's base was prepared. The electrode exhibited a Nernstian response for Cu$^{2+}$ ions over a wide concentration range (1.0 ${\times}$ 10$^{-1}$ to 1.0 ${\times}$ l0$^{-6}$ M) with a limit of detection of 6.0 ${\times}$ 10$^{-7}$ M (39 ppb). The sensor shows a fast response time (15s) and the membrane can be used for more than 4 months without observing any major deviation. The electrode revealed very good selectivity with respect to many cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor could be used in a pH range of 3.0-7.5. It was applied to the direct potentiometric determination of copper in black tea, and in wastewater of copper electroplating samples. The electrode was also used in potentiometric titration of the copper(II) ion with EDTA.

Determination of Copper in Black, Red Pepper and the Waste Water Samples by a Highly Selective Sensitive Cu(II) Microelectrode Based on a New Hexadentates Schiff's Base

  • Norouzi, Parviz;Ganjali, Mohammad Reza;Faridbod, Farnoush;Salavati-Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1439-1444
    • /
    • 2006
  • A $Cu^{2+}$ ion-selective membrane microelectrode has been fabricated from poly vinyl chloride (PVC) matrix membrane containing a new symmetrical hexadentate Schiff,s base 2-{1-(E)-2-((Z)-2-{(E)-2-[(Z)-1-(2-hydroxyphenyl)ethylidene]hydrazono}-1-methylpropylidene)hydrazono]ethyl}phenol (HDNOS) as a neutral carrier, Potassium tetrakis(4-chlorophenyl) borate (KTpClPB) as an anionic excluder and o-nitrophenyloctyl ether (NPOE) as a plasticizing solvent mediator. The microelectrode displays linear potential response in the concentration range of $1.0\;{\times}\;10^{-5}-1.0\;{\times}\;10^{-11}$ M of $Cu^{2+}$. The microelectrode exhibits a nice Nernstian slope of 25.9 ${\pm}$ 0.3 mV $decade^{-1}$ in the pH range of 3.1-8.1. The sensor has a relatively short response time in whole concentration ranges ($\sim$5 s). The detection limit of proposed sensor is $5.0\;{\times}\;10^{-12}$ M (320 pg/L), and it can be used over a period of eight weeks. The practical utility of the sensor has been demonstrated by using it as an indicator electrode in the potentiometric titration of $Cu^{2+}$ with EDTA. The proposed membrane electrode was used for the direct determining of $Cu^{2+}$ content in black and red pepper, and in waste water samples.